ORI-140 Vector Magnetic Level Indicator

TM
MAGNETIC LEVEL INDICATOR
Vector™ is a rugged, reliable and costeffective Magnetic Level Indicator (MLI).
Suitable for a variety of installations, Vector
has many basic features and is precisionengineered and manufactured to ensure a
long service life.
MLIs are widely used to replace highmaintenance
sight
and
gauge
glass
indicators and are increasingly used in
new applications. Optional switches and
transmitters are available to provide various
output signals for level control.
TM
•
Feedwater
heaters
•
Blowdown flash tanks
•
Hot wells
•
Oil/water
separators
•
Vacuum tower bottoms
•
Flash drums
•
Alkylation units
•
Surge tanks
•
Propane vessels
•
Gas chillers
•
Storage tanks
•
Deaerators
...and many others
2
Principle of Operation
A float travels up and down in a chamber that is mounted to a liquidcontaining vessel. The float contains a magnetic assembly that
interacts with an externally-mounted visual indicator. As the float
follows the liquid surface or liquid-liquid interface, the magnetic field
causes highly contrasting flags in the visual indicator to rotate. The
result is a clearly defined representation of the liquid level in the vessel.
Features
•
Rugged, industrial-grade construction
•
Field adjustable visual indicator for convenient viewing
•
Continuous measuring range up to 216 in. (549 cm)
•
Compatible with electronic point switches and continuous level transmitters
•
Media specific gravity as low as 0.54
•
Shatter-resistant viewing window
•
Single magnet per flag to enhance float coupling effect and self-alignment
The Vector™ float contains high-strength alloy magnets that facilitate a strong
coupling with the externally-mounted visual indication, as well as any switches
or transmitters.
Every float is manufactured specifically for each application. Process pressure,
temperature, and media specific gravity are all factored into the custom design.
The Vector™ high-visibility visual indicator is constructed with
quality materials and engineered for reliable performance.
Each flag contains an alloy magnet that maximizes coupling with
the float. The flags are mechanically limited to a half-rotation,
which eliminates the possibility of over-rotation common with
other magnetic level indicators.
3
1
2
1
3
4
5
6
7
8
9
10
11
Unit of Measure for Center-to-Center
3
Mounting Configuration & Chamber Construction
6
7
8
Connection Orientation
Chamber Top
Chamber Bottom
A
Side / Side
Welded Flat Cap
Threaded Plug (NPT)
B
Side / Side
Threaded Plug (NPT)
Welded Flat Cap
1
Side / Side
Welded Flat Cap
Flange
2
Side / Side
Flange
Welded Flat Cap
16
17
19
20
21
22
23
A
150#
B
300#
Material of Construction
A
316/316L Stainless Steel Chamber
B
316/316L Stainless Steel Chamber with Carbon Steel Fittings & Flanges
C
304/304L Stainless Steel Chamber
D
304/304L Stainless Steel Chamber with Carbon Steel Fittings & Flanges
1
PVC plastic
2
CPVC plastic
Option A
Option B
Option 1
Option 2
Construction Grade
1
Industrial Grade
Chamber Flange Type
N
No Chamber Flange (required if model code 3 is either A or B)
A
Raised Face Slip-On Flange (required if model code 3 is either 1 or 2)
P
Full Face Socket Flange (for PVC and CPVC material only)
9
Process Connection Type
A
Process Connection Size
A
1/2”
M Male Threaded (NPT)
B
3/4”
R
C
1”
D
1-1/2”
E
2”
Raised Face Flange, Slip-On Style
Butt Weld
Van Stone Flange (PVC / CPVC only)
Gasket Style for Chamber Flange (if applicable)
N
None (required if model code 3 is either A or B)
A
Flexible Graphite Ring (required if model code 3 is either 1 or 2)
P
EPDM Rubber (required if model code 5 is either 1 or 2)
8
Process Connection Type
Consult factory.
Chamber Bolting Material
N
None (required if model code 3 is either A or B)
Q
Alloy Steel with Cadmium Plating (required if model code 3 is either 1 or 2)
24
25
Mounting Configuration & Chamber Construction
RFSO Flange
Option A
4
18
Required Flange Rating
 Other gasket options available.
11
15
E English (inches)
M Metric (centimeters)
1
10
14
3
Vector™ Magnetic Level Indicator
2
5
13
Product Name
4
4
12
Threaded NPT
Option M
Buttweld
Option R
1
2
19
3
4
5
6
7
8
9
10
11
12
13
12‒13
Measuring Scale
14
15
16
17
18
19
20
21
22
23
24
25
Vent Size & Type
NN None
11 1/2” NPT with Hex Plug
21 3/4” NPT with Hex Plug
14‒15
Drain Size & Type
NN None
11 1/2” NPT with Hex Plug
21 3/4” NPT with Hex Plug
16
INSTRUMENTS
INSTRUMENTS
Option N
Option 1
INSTRUMENTS
Option 2
Other Considerations for Chamber Construction ‚
N
None
1
Jupiter Transmitter (Top Mount)
2
Jupiter or OCT Transmitter (Top Mount Offset & Top Mount High Temperature)
3
Jupiter or OCT Transmitter (Bottom Mount, Bottom Mount High Temperature)
‚ Vector can be combined with various externally-mounted accessories,
INSTRUMENTS
including switches and transmitters. Transmitter, however, requires the MLI
chamber to be lengthened slightly to accommodate the probe.
Option 3
Refer to pages 6 & 7 for additional information regarding accessories.
23‒25
Center-to-Center & VIL
17
Insulation Options
N
None
T
Transmitter Pad: Required for Jupiter or OCT between 165°F to 375°F (74°C to 191°C)
V
Indicator & Jupiter Pad: Required between 376°F to 850°F (192°C to 454°C)
W Indicator & OCT Pad: Required between 376°F to 425°F (192°C to 218°C)
18
19
orionxpress
Y
Pad for Indicator Only: Required when temperatures greater than 375°F (191°C)
A
Insulation Blanket for Chamber: Optional up to 500°F (260°C)
Measurement Type & Indication Style
Total level
1 Orange / Black Flags
Interface level
5 Orange / Black Flags
2
Yellow / Black Flags
6
Yellow / Black Flags
3
Red / White Flags
7
Red / White Flags
4
Red / Silver Flags
8
Red / Silver Flags
Measuring Scale
N
None
1
Feet / Inches
2
Meters / Centimeters
3
Running Inches
4
Percent (markings in increments of 5%)
20‒22
Factory Assigned Codes
23‒25
Center-to-Center & Visual Indication Length
X X X These codes are factory assigned based on application data
shipment program
Expedited 3 week lead time at no additional
cost. See back cover for additional details.
some restrictions apply
XXX
Specify in INCHES when model code 2 is E
Specify in CENTIMETERS when model code 2 is M
5


‚
Configuration A
‚
Configuration B


‚
Configuration 1
Notes: 
‚
Configuration 2
Upper chamber dimension will vary if a Jupiter or OCT level transmitter is specified.
‚ Lower chamber dimension varies to accommodate extended floats. Lower specific gravities normally result in longer floats to
achieve required amount of buoyancy force.
6
SPECIFICATIONS | VECTOR™ MAGNETIC LEVEL INDICATOR
Product Name
Vector™
Materials of Construction – MLI
316/316L stainless steel 304/304L stainless steel
Carbon Steel process connections and fittings available
Chamber material must be non-ferromagnetic
Materials of Construction – Float
Stainless steel and titanium - varies depending on process conditions
Construction Grade
Industrial
Certified material test report (CMTR)
Available upon request
Pressure Class Ratings
ANSI 150# & 300#
Process Connection Sizes
1/2”
Process Connection Types
Raised face slip-on style flange, threaded nipple, buttweld nipple
Measuring Range
12 to 216 in (30 to 549 cm)
Temperature Range
-40° to +500° F (-40° to +260° C)
Pressure Range
Full vacuum to 740 psig (51.02 bar)
3/4”
1”
1-1/2”
2”
All chambers are hydrostatically tested at 1.5x design pressure
Specific Gravity Range
≥ 0.54
Visual Indicators
Magnetically actuated flag assembly in contrasting orange/black, yellow/black,
red/white, or red/silver colors
Maximum Viewing Distance
Approximately 100 feet (31 meters)
Measuring Scale
Feet/Inches, Meters/Centimeters, Running Inches
Switch Options
Model OES electric cam operated snap action (refer to Orion bulletin: OES-100)
Model ORS electric reed type (refer to Orion bulletin: ORS-300)
Transmitter Options
Model 2xx Jupiter Magnetostrictive (refer to Orion bulletin: ORI-148)
Model OCT analog reed chain (refer to Orion bulletin: OCT-400)
High Temperature Insulation
Fiberglass material with weather-resistant silicone jacket
ACCESSORIES
Electronic Point Level Switches
Model: OES
10.1 Amp DPDT Snap Action Switch
refer to bulletin: OES-100
Model: ORS
1 Amp SPDT Reed Switch
refer to bulletin: ORS-300
Continuous Level Transmitters
Model: OCT
Reed Chain Transmitter
refer to bulletin: OCT-400
Model: Jupiter
Magnetostrictive Transmitter
refer to bulletin: ORI-148
Magnetic Particle Trap
Ideal for process media containing ferrous particles. These
particles can enter the MLI chamber and coat the magnetic float
rendering it inoperable. The trap will collect these particles so
that they can be periodically removed.
7
Magnetic Level Indicator (MLI)
orionxpress
shipment program
MLI with Integral
Guided Wave Radar
Dual-Chamber MLI
Magnetostrictive Tansmitter
Orion Instruments is dedicated to reducing product lead times through ongoing efficiency
initiatives and strategic inventory management. OrionXpress is available for select product
configurations and will allow your product to ship within 3 weeks of placing the order.
Look for the blue shaded options throughout the model number:
E
Example
2105 Oak Villa Boulevard • Baton Rouge, Louisiana 70815 • 225-906-2343 • Toll Free 866-55-ORION (866-556-7466) • Fax 225-906-2344 • www.orioninstruments.com
Copyright © 2014 Orion Instruments, LLC. All rights reserved. Printed in the USA.
Performance specifications are effective with date of issue and are subject to change without notice.
Orion, Orion logotype, Magnetrol, Magnetrol logotype, Aurora, and Eclipse are registered trademarks of Magnetrol International.
Atlas, Gemini, Vector, Jupiter, and InstaSeal are trademarks of Magnetrol International.
REGISTERED TO ISO 9001:2008
BULLETIN: ORI-140.1
EFFECTIVE: JUNE 2014