Measurement of High Capacitance MLCC

0408_R2
www.NICcomp.com
Tech Support: [email protected]
COMPONENT TEST CONDITIONS
PRODUCTS: CERAMIC CAPACITORS
LEADED AND SURFACE MOUNT (MLCC)
INDUSTRY STANDARDS: EIA-198-1F & JIS C 5101
CHARACTERISTIC
TC
CAPACITANCE
CLASS I
DISSIPATION FACTOR
TEST CONDITIONS (@ +25°C)
C ≤1000pF @ 1MHZ, 1.2VRMS MAXIMUM
C >1000pF @ 1KHZ, 1.2VRMS MAXIMUM
1KHZ, 1.0 ±0.2 VRMS (C ≤10uF)
CAPACITANCE
CLASS II
DISSIPATION FACTOR
120Hz, 0.5 ±0.2 VRMS (C >10uF)
Y5V @ 1KHZ, 1.0 ±0.2 VRMS
CAPACITANCE
CLASS III
DISSIPATION FACTOR
ALL OTHERS @ 1KHZ, 0.5 ±0.2 VRMS
INSULATION RESISTANCE
ALL
AFTER 2 MINUTES AT RATED VDC
DIELECTRIC WITHSTAND
VOLTAGE
ALL
125% ~ 400%* RATED VOLTAGE
FOR 5 ±1 SECONDS
SPECIFICATION LIMITS: See NIC specification data sheets
TC: Temperature Coefficients
CLASS I: NPO(COG), N150, SL(N330), N470, N750, N1500 & N3300
CLASS II: X7R, X5R, Y5F, Y5P & Y5R
CLASS III: Y5S, Y5T, Y5V, Z5U & Z5V
* - As specified; see NIC specification data sheets
HIGH- CAPACITANCE MLCCs (C ≥ 1uF X5R, X7R, Y5V) :
•
High-capacitance value MLCCs can present measurement challenges to some test equipment. Common
capacitance value errors are caused by the low impedance of high capacitance MLCCs, often resulting to
greatly reduce the test signal across the device under test (DUT).
•
TEST EQUIPMENT: Agilent HP4284A Precision LCR meter
o
This LCR meter has “ALC” automatic level control feature that compensates for DUT loading
o
If “ALC” function is disabled, the DUT impedance can be seen to greatly reduce the test level
and result in incorrect capacitance measurement
o
EXAMPLE: 10uF MLCCs … NIC P/N: NMC1206Y5V106Z10 or NMC0805X5R106K6.3
o
Test Level set at 1.0Vrms
o
With ALC OFF, test level drops to 0.2Vrms upon DUT insertion and incorrect capacitance
measurement of “7.24uF”
o
With ALC ON , test level is maintained at 1.0Vrms upon DUT insertion and correct capacitance
measurement of “10.08uF”
RECOMMENDATION:
•
Monitor (measure) and adjust test level to achieve correct test level across DUT, see EIA-198-1F test
conditions table above.
•
For guidance, please contact NIC technical support personnel [email protected]
ISO 9001–2000 REGISTERED