Technical Data RDY4, RDY8

RDY4 - RDY8
Differential pressure switch with intrinsic safety
Main Features
„„
Excellent repeatability
„„
Dead band adjustment for regulation
„„
Fix dead band for control and alarm
„„
Intrinsic safety Hazardous area 0, 1, 2
Applications
„„Power generation safety equipment
„„Pressurized chambers control
„„Liquid level control
Technical Data
Pressure range
2 ... 10 mbar to 2.5 ... 30 bar
Case
Black Zamak
Temperature
Pressure range codes 111 to 157
Medium : -15 ... +150°C
Ambient : -25 ... + 55°C
Storage : -40 ... + 70°C
Mounting
Wall mounting braket
Ground connection
Via internal terminal block
Electrical
connection
Electrical function
Terminal block with plastic cable gland for
Ø 7 to 10.5 mm
Adjustment
2 external adjustment screws for set point and
dead band.
When set point adjustment is required it is necessary to know the static pressure, as it has an
influence on the set point.
Type examination certificate
LCIE 03 ATEX 6123X
EN 60079-0: 2012 (internal conformity analysis)
EN 60079-11: 2012
Marking
0081
IM1
Ex ia I Ma
II 1 G
Ex ia IIC T6 or T5 Ga
Electrical data
Umax = 28 Vdc
Imax = 120 mA
Pmax = 0.84 W
CE conformity
Protection rating
Low Voltage Directive LVD 2006/95/EC
Pressure Equipment Directive PED 97/23/EC
ATEX Directive 94/9/EC
IP 66 (EN 60529)
Process connection Stainless steel 1.4404 (316L)
Sensing element
Pressure range codes 111 to 157
Flanges :Stainless steel 1.4404 (316L)
Diaphragm :Viton®
Pressure range codes 211 to 256
Bellow :Stainless steel 1.4404 or
1.4432 (316L)
Scale
Cover
Pressure range codes 257 and 258
Piston :Nickel plated steel
Internal. Accuracy on reading ± 5% FS
Zamak blue painted
Captive stainless steel screws
ATEX
See ordering code details on page 5
Ci = Negligible ; Li = Negligible
Customer specific set point adjustment
Code SETP
Oxygen application
Code 0765
Mounting on 2" pipe
Code 0407
Electrical connection: stainless steel connector (Souriau)
Code 2298
Mobile plug for stainless steel connector (Souriau)
Code 2249
Stainless steel tag plate and wire
Code 9941
Lead seal of the adjustment screws
Code 8990
www.baumer.com
2015-04-23
Options
Design and specifications subject to change without notice
Repeatability
Pressure range codes 211 to 256
Medium : -50 ... +200°C
Ambient : -25 ... + 55°C
Storage : -40 ... + 70°C
± 1% F.S. @ constant pressure cycle
Data sheet A32.21
Page 1 / 5
RDY4 - RDY8
Differential pressure switch with intrinsic safety
Principle
∆P
A flexible sensing element actuates a microswitch by means of a
piston. The set point is adjusted by means of a compressible spring
installed in opposition.
NC
NC
NC
C
C
C
NO
NO
HP < LP
NO
HP > LP
Set point and reset point must be between 10% and 90% of the selected scale.
Standard factory adjustment
Setpoint at 50% of the scale on falling pressure
NC
C
NC
NC
C
C
NO
NO
NO
Customer speciffic factory adjustment (option SETP)
The following specifications have to be given with the order:
• Setpoint value
• Adjustment on falling or raising pressure.
• Static pressure
• Dead band value when using an adjustable dead band switch
Electrical connections
2 SPDT
1 SPDT
NC
Blue
COM
Red
NO
White
NC
Blue
COM
Red
NO
White
NC
Blue
COM
Red
Yellow / green
NO
White
Yellow / green
Certified safety
barrier
NO
C
Non hazardous
area
NO
or NC
NC
+
Rc 1
Supply
–
Screen
For max. ambient temperature refer to technical data on page 1.
The installation must be made in an intrinsically safe circuit whose certified electrical safety parameters do not exceed any of the values Umax,
Imax and Pmax given in the electrical data on page 1.
2015-04-23
All necessary measures must be taken by the user, to avoid the calorific transfer from the fluid to the apparatus head increasing the head's
temperature to such that it reaches the self-ignition temperature of the gas in which it is used.
Design and specifications subject to change without notice
Hazardous area
Zone 0, 1, 2
www.baumer.com
Data sheet A32.21
Page 2 / 5
RDY4 - RDY8
Differential pressure switch with intrinsic safety
Micro switches characteristics
Switch code
N (T)
M (K)
C (W)
S
Type
Tropicalized
Gold contact
Hermetic
Ultrasensitive
Gold contact
6 Vdc
0.1 ... 0.12 A
10 ... 50 mA
5 ... 120 mA
10 ... 50 mA
12 Vdc
N/A
10 ... 50 mA
5 ... 66 mA
10 ... 50 mA
24 Vdc
N/A
10 ... 33 mA
5 ... 33 mA
10 ... 33 mA
30 Vdc
N/A
N/A
N/A
N/A
48 Vdc
N/A
N/A
N/A
N/A
110 Vdc
N/A
N/A
N/A
N/A
220 Vdc
N/A
N/A
N/A
N/A
115 Vac
N/A
N/A
N/A
N/A
250 Vac
Dielectric rigidity between contacts and ground
N/A
N/A
N/A
N/A
2000 V
2000 V
1500 V
2000 V
Adjustable ranges
Scale
mbar
2 ... 10
Max P
Static
Micro-switch dead band 1)
Adjustable dead band
Code
N (T*)
M (K*)
Fixed dead band
C(W*)
10%
90%
10%
S
90%
10%
90%
mbar
bar
10
0.15
111
1.2 - 10
1.6 - 10
4.5 - 10
4.5 - 10
0.7
1.2
121
1.7 - 30
2.2 - 30
5 - 30
5.5 - 30
0.9
1.4
mbar
2 ... 50
50
0.15
2 ... 100
100
0.15
131
1.7 - 40
2.5 - 40
5.5 - 40
10 - 40
1.2
2
10 ... 200
200
1
156
8 - 80
10.5 - 80
25 - 80
40 - 80
5.8
9.5
400
1
157
15 - 150
20 - 150
30 - 150
45 - 150
10.5
17
0.06
0.09
10 ... 400
Code
bar
0.05... 0.5
0.5
7
211
bar
0.09 - 0.3
0.1 - 0.3
0.15 - 0.4
0.2 - 0.4
0.05... 1
1
7
221
0.09 - 0.3
0.1 - 0.3
0.15 - 0.4
0.22 - 0.4
0.06
0.09
0.15... 0.5
0.5
30
214
0.14 - 0.5
0.18 - 0.5
N/A
N/A
0.12
0.18
0.15... 1
1
30
224
0.2 - 0.6
0.25 - 0.6
N/A
N/A
0.12
0.18
0.15... 4
4
30
234
0.21 - 1.5
0.27 - 1.5
0.65 - 2
0.8 - 2
0.12
0.18
0.8... 4
4
30
235
0.7 - 2.5
1.1 - 2.5
0.75 - 2.5
1.1 - 2.5
0.16
0.28
0.8... 10
10
30
245
0.7 - 2.5
1.1 - 2.5
0.75 - 2.5
1.1 - 2.5
0.16
0.28
1.5... 10
10
65
246
1.2 - 5
2.5 - 5
2.5 - 6
3.5 - 6
0.42
0.68
1.5... 20
20
65
256
1.2 - 5
2.5 - 5
2.5 - 6
3.5 - 6
0.42
0.68
2.5... 20
20
220
257
2.5 - 20
3.5 - 20
6 - 20
7 - 20
1.85
2.8
2.5... 30
30
220
258
3 - 30
4 - 20
6 - 20
7 - 20
1.95
2.8
(*) For version with 2 microswitches lower values of the dead band must be multiplied x 1.5
The value of the dead band is depending on the value of the set point.
This table contains the dead band values for set point adjustment at 10% and 90% of the selected scale. For adjustable dead band the lower value corresponds to the
dead band spring totally released and the higher corresponds to the dead band spring fully tensed . For other set points the dead band value can be calculated by
linear interpolation between the values at 10% and 90%.
2015-04-23
1)
Design and specifications subject to change without notice
Max
ΔP
www.baumer.com
Data sheet A32.21
Page 3 / 5
RDY4 - RDY8
Differential pressure switch with intrinsic safety
Dimensions (mm)
125
76.5
=
144
139
=
58
130
5
64
100
45°
Pressure range codes : 111 - 121 - 131
Weight : 3 kg
Pressure range codes : 156 - 157
Weight : 2.8 kg
76.5
76.5
28.5
28.5
1/2 NPT(M)
LP
80
78
LP
HP
Hex 24
HP
1/2 NPT(M)
46.5
70
Pressure range codes : 211 - 221
Weight : 3 kg
130
76.5
76.5
144
144
130
Pressure range codes : 214 - 224 - 234 - 235 - 245 - 246 - 256 - 257 - 258
Weight : 3 kg
28.5
124
28.5
60
124
LP
136
89
HP
60
HP
LP
70
Ø 65
27
70
G 1/2(M)
2015-04-23
G 1/2(M)
Design and specifications subject to change without notice
Hex 24
www.baumer.com
Data sheet A32.21
Page 4 / 5
RDY4 - RDY8
Differential pressure switch with intrinsic safety
Ordering details RDY4 - RDY8
RD
Model
Differential pressure switch
Approvals
ATEX intrinsic safety
Y
.
–
xxx
/
RD
Y
Sensing element
Diaphragm (Viton®, range 111 to 157)
Bellow (stainless steel, range 211 to 256) or Piston (nickel plated steel, range 257 and 258)
Type of micro switches
Deadband
1 SPDT hermetically changeover switch
Adjustable
2 SPDT hermetically changeover switch
Adjustable
1 SPDT gold contact changeover switch
Adjustable
2 SPDT gold contact changeover switch
Adjustable
1 SPDT tropicalized changeover switch
Adjustable
2 SPDT tropicalized changeover switch
Adjustable
1 SPDT ultrasensitive gold contact changeover switch
Fix
Process connection
G 1/2 male (standard)
1/2 NPT male
1/4 NPT female
–
4
8
C
W
M
K
N
T
S
3
6
8
Pressure range (mbar)
Pressure range (kPa)
2
...
10
0.2 ...
1
2
...
50
0.2 ...
5
2
...
100
0.2 ...
10
10
...
200
1
...
20
10
...
400
1
...
40
Pressure range (bar)
Pressure range (kPa)
0.05 ...
0.5
5 ...
50
0.05 ...
1
5 ...
100
0.15 ...
0.5
15 ...
50
0.15 ...
1
15 ...
100
0.15 ...
4
15 ...
400
0.8 ...
4
80 ...
400
0.8 ...
10
80 ... 1000
1.5 ...
10
150 ... 1000
1.5 ...
20
150 ... 2000
2.5 ...
20
250 ... 2000
2.5 ...
30
250 ... 3000
Options to be added behind the / (see example below)
.
111
121
131
156
157
211
221
214
224
234
235
245
246
256
257
258
/
Ordering example with options
RD
Y
–
4
C
3
.
111
/
0407
_
9941
Differential pressure switch
With ATEX approval intrinsic safety
Design and specifications subject to change without notice
Diaphragm Viton®
1 SPDT hermetically changeover switch
Process connection G 1/2 male
Pressure range 2 ... 10 mbar
Option : Mounting on 2" pipe
2015-04-23
Option : Stainless steel tag plate and wire
www.baumer.com
Data sheet A32.21
Page 5 / 5