RPHN Industrial pressure switch with high overpressure resistance Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm High over pressure resistant Applications Power generation safety equipment Pressurized chambers control Liquid level control Technical Data Pressure range -50 mbar ... 0 to 0 ... 2500 mbar Temperature Process : Ambient : Storage : -15 ... +150°C -25 ... +70°C -40 ... +70°C Repeatability ± 1% F.S. @ constant pressure cycle CE conformity Low Voltage Directive LVD 2006/95/EC Pressure Equipment Directive PED 97/23/EC IP 66 (EN 60529) Protection rating Electrical connection Terminal block with plastic cable gland for Ø 7 to 10.5 mm Electrical function See ordering code details on page 5 Adjustment 2 external adjustment screws on top of the case for set point and dead band Process Connection Stainless steel 1.4404 (316L) Sensing element Scale Cover Flanges : Stainless steel 1.4404 (316L) Diaphragm : Viton® Internal. Accuracy on reading ± 5% FS Case Zamak blue painted Captive stainless steel screws Black Zamak Mounting Wall mounting braket Ground connection Via internal terminal block Customer specific set point adjustment Code SETP Oxygen application Code 0765 Mounting on 2" pipe Code 0407 Design and specifications subject to change without notice Options Electrical connection : stainless steel connector (Souriau) Code 2298 Code 2249 Stainless steel tag plate and wire Code 9941 Lead seal of the adjustment screws Code 8990 2015-04-23 Mobile plug for stainless steel connector (Souriau) www.baumer.com Data sheet A32.07 Page 1 / 5 RPHN Industrial pressure switch with high overpressure resistance Principle A flexible sensing element actuates a microswitch by means of a lever. The set point is adjusted by means of a compressible spring installed in opposition. NC NC NC C C C NO NO NO Set point and reset point must be between 10% and 90% of the selected scale. Standard factory adjustment Setpoint at 50% of the scale on falling pressure Customer specific factory adjustment (option SETP) The following specifications have to be given with the order: • Setpoint value • Adjustment on falling or raising pressure • Dead band value when using an adjustable dead band switch NC C NC NC C C NO NO NO Electrical connections 2 SPDT 1 SPDT NC Blue COM Red NO White NC Blue COM Red NO Yellow / green NC COM NO White Blue Red White 2015-04-23 Design and specifications subject to change without notice Yellow / green www.baumer.com Data sheet A32.07 Page 2 / 5 RPHN Industrial pressure switch with high overpressure resistance Micro switches characteristics Switch code N (T) A (B) M (K) C (W) E (F) H D (V) J Type Tropicalized Standard Gold contact Hermetic Ultra sensitive Manual reset Ultra sensitive Hermetic Manual reset 6 Vdc 0.1 ... 8 A 0.4 ... 10 A 10 ... 50 mA 5 mA ... 4 A 0.4 ... 1 A N/A 0.4 ... 4 A N/A 12 Vdc 0.1 ... 8 A 0.4 ... 10 A 10 ... 50 mA 5 mA ... 4 A 0.4 ... 1 A N/A 0.4 ... 4 A N/A 24 Vdc 0.1 ... 8 A 0.4 ... 6 A 10 ... 50 mA 5 mA ... 4 A 0.4 ... 1 A 0.1 ... 8 A 0.4 ... 4 A 0.1 ... 8 A 30 Vdc 0.1 ... 8 A 0.4 ... 6 A 10 ... 10 mA 5 mA ... 3 A 0.4 ... 1 A 0.1 ... 8 A 0.4 ... 2 A 0.1 ... 8 A 48 Vdc 0.1 ... 8 A 0.4 ... 6 A 10 ... 50 mA 5 mA ... 3 A N/A 0.1 ... 8 A N/A 0.1 ... 8 A 110 Vdc N/A 0.1 ... 0.5 A 10 ... 50 mA 5 mA ... 1 A N/A N/A N/A N/A 220 Vdc N/A 0.1 ... 0.25 A 10 ... 50 mA 5 mA ... 0.5 A N/A N/A N/A N/A 115 Vac 0.1 ... 10 A 0.4 ... 10 A 10 ... 50 mA 50 mA ... 3 A 0.4 ... 10 A 0.1 ... 10 A N/A 0.1 ... 10 A 250 Vac 0.1 ... 5 A 0.2 ... 10 A 10 ... 100 mA 50 mA ... 2.5 A 0.2 ... 10 A 0.1 ... 5 A N/A 0.1 ... 5 A 2000 V 2000 V 2000 V 1500 V 2000 V 2000 V 1000 V 2000 V Dielectric rigidity between contacts and ground Adjustable ranges Micro-switch dead band 1) P. Max accidental Adjustable dead band Code mbar -50 ... 10% bar 0 10 N (T*) A (B*) M (K*) 90% Fixed dead band C (W*) 10% E (F*) 90% H D (V*) J 10% 90% 10% 90% 0.6 0.6 2.5 3 mbar 101 2 - 25 2.5 - 25 6.5 - 25 7.5 - 25 -2 ... 10 10 102 1 - 10 1 - 10 N/A N/A 0.4 0.4 1.5 1.5 -5 ... 50 10 103 1 - 20 2 - 20 4.5 - 20 5 - 20 0.4 0.4 1.5 2.5 -8 ... 100 10 104 1.5 - 25 2.5 - 25 5 - 25 10 - 25 0.5 0.5 2 3 0 50 151 12 - 80 20 - 80 25 - 80 40 - 80 3 4 14.5 25 0 ... 200 50 152 15 - 80 25 - 80 30 - 80 45 - 80 3.5 4 18 30 0 ... 400 50 153 17 - 150 30 - 150 35 - 150 50 - 150 4 5.5 20.5 35 0 ... 1000 50 154 22 - 150 35 - 150 45 - 150 60 - 150 6 7 26.5 45 0 ... 700 100 171** 20 - 350 40 - 350 40 - 350 70 - 350 7 9 24 50 0 ... 1500 100 172** 20 - 350 60 - 350 40 - 350 100 - 350 7 9 24 75 100 173** 25 - 350 90 - 350 50 - 350 160 - 150 9 11 30 110 -200... 0 ... 2500 (*) When using 2 microswitches dead band lower values should be x1.5 (**) G1/4 female only The value of the dead band is depending on the value of the set point. This table contains the dead band values for set point adjustment at 10% and 90% of the selected scale. For adjustable dead band the lower value corresponds to the dead band spring totally released and the higher corresponds to the dead band spring fully tensed . For other set points the dead band value can be calculated by linear interpolation between the values at 10% and 90%. 2015-04-23 1) Design and specifications subject to change without notice Scale www.baumer.com Data sheet A32.07 Page 3 / 5 RPHN Industrial pressure switch with high overpressure resistance Dimensions (mm) 125 76.5 = 144 139 = 58 130 5 64 100 45° Pressure range codes : 151 - 152 - 153 - 154 Weight : 6.4 kg 61 Ø 145 64 56 Hex 24 Ø 120 2015-04-23 Design and specifications subject to change without notice G 1/2(M) G 1/4 12 Ø 245 Hex 24 Hex 24 Hex 24 Hex 24 G 1/2(M) Pressure range codes : 171 - 172 - 173 Weight : 7 kg 84 Pressure range codes : 101 - 102 - 103 - 104 Weight : 10 kg www.baumer.com Data sheet A32.07 Page 4 / 5 RPHN Industrial pressure switch with high overpressure resistance Ordering details RPHN RP Model Industrial pressure switch with high overpressure resistance Approvals Standard version without ATEX approval Type of micro switches 1 SPDT standard changeover switch 2 SPDT standard changeover switch 1 SPDT hermetically changeover switch 2 SPDT hermetically changeover switch 1 SPDT ultra sensitive changeover switch 2 SPDT ultra sensitive changeover switch 1 SPDT hermetically, ultra sensitive changeover switch 2 SPDT hermetically, ultra sensitive changeover switch 1 SPDT gold contact changeover switch 2 SPDT gold contact changeover switch 1 SPDT tropicalized changeover switch 2 SPDT tropicalized changeover switch 1 SPDT changeover switch, manual reset, opening on raising pressure 1 SPDT changeover switch, manual reset, opening on falling pressure Pneumatic changeover contact, NO Pneumatic changeover contact, NC Type Standard Process connection G 1/4 female (only pressure ranges 171, 172, 173) G 1/2 male (standard) 1/2 NPT male 1/4 NPT female Pressure range (mbar) Pressure range (kPa) -50 ... 0 -5 ... 0 -2 ... 10 -0.2 ... 1 -5 ... 50 -0.5 ... 5 -8 ... 100 -0.8 ... 10 -200... 0 -20 ... 0 0 ... 200 0 ... 20 0 ... 400 0 ... 40 0 ... 1000 0 ... 100 0 ... 700 0 ... 70 0 ... 1500 0 ... 150 0 ... 2500 0 ... 250 Options to be added behind the / (see example below) HN A – . xxx / RP HN – Deadband Adjustable Adjustable Adjustable Adjustable Fix Fix Fix Fix Adjustable Adjustable Adjustable Adjustable Fix Fix A B C W E F D V M K N T H J Z Y A H 3 6 8 . 101 102 103 104 151 152 153 154 171 172 173 Process connection G1/4 female Process connection G1/4 female Process connection G1/4 female / Ordering example with options RP HN – A A 3 . 101 / 0407 _ 9941 Design and specifications subject to change without notice Industrial pressure switch Without ATEX approval 1 SPDT standard changeover switch Standard type Process connection G 1/2 male Pressure range -50 ... 0 mbar Option : Mounting on 2" pipe 2015-04-23 Option : Stainless steel tag plate and wire www.baumer.com Data sheet A32.07 Page 5 / 5