TG-LTG-Series Datasheet

TG/LTG-Series
Rocker Switches
The TG-Series Mini Tippette rocker switches are single or double pole and feature an
all nylon double-insulated construction. These switches are designed with snap-in
mounting for fast, low cost assembly. The illuminated version (LTG) is available with
either a paddle or rocker actuator. These AC rated switches are also suitable for lowvoltage DC applications assuring compatibility for a wide range of markets including
Appliance, HVAC, Food service, and Transportation.
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062-1177
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: [email protected] • www.carlingtech.com
2 | TG/LTG-Series Rocker Switches
Dielectric Strength
Mechanical Life
UL/CSA:
1000V - live to dead metal parts
100,000 cycles
Operating Temperature
Electrical Life
32°F to 185°F (0°C to 85°C)
50,000 cycles - maintained
25,000 cycles - momentary
LTG G O 50 1
1
Base Part Number
2
Circuit
3
Center
Position
4
Rating
5
Termination
T B
6
Actuator
Style
B
7
Actuator
Color
8
Base Color
6 ACTUATOR STYLE
1 BASE PART NUMBER: SERIES
TG
Double Pole, Non-Lighted
LTG
Double Pole with Indicator Lights
P
Paddle
7 ACTUATOR COLOR2
2 CIRCUIT1
See Circuit Designation Chart.
B
Black
8 BASE COLOR2
3 CENTER POSITION
C
Center OFF, Three position
O
No Center OFF, Two position
B
Black
9 LENS COLOR3
AAmber
4 RATING
40
5A 250VAC, 10A 125VAC, 1/2HP 125-250VAC
41
5A 250VAC, 10A 125VAC
50
10A 250VAC, 15A 125VAC, 3/4HP 125-250VAC
51
10A 250VAC, 15A 125VAC
incandescent
6V
6 volt
12V
12 volt
18V
18 volt
24V
24 volt
28V
28 volt
.156[3.96] DIA
.375[9.52]
.250[6.35]
.210[5.33]
.050[1.27]
1.240[31.50]
Rocker
W
White
W
White
RRed
neon
125N
250N
125 volt neon
250 volt neon
Notes:
Imprinting is available. Consult factory.
Panel Cut-Out Recommendations: For sheet metal panels, switch must enter panel in same
direction as the punch. (Burr on bottom.) Test cut hole in actual material.
1 TG available with circuits A, B, C, D, E, F ; LTG available with circuits
G, H, I, J, M, N, P, Q, R, T, U, V, Y, Z.
2 Custom colors are available. Consult factory.
3 Specify lens color for LTG-Series only.
( ) Indicates momentary function.
.069[1.75] DIA
1.155[29.33]
10
Lamp Voltage
T
CClear
10 LAMP VOLTAGE
5 TERMINATION/FUNCTION
Solder Lug .250 Tab QC .187 Tab QC Wire Leads
On-None-Off
0 1
3
5
(On)-None-Off
AB D F
On-None-(Off)
LM R T
On-None-On
01 3 5
On-None-(On)
AB D F
On-Off-On
01 3 5
.865[21.97]
R / 125
9
Lens Color
.250[6.35]
SOLDER LUG
.250 TAB (Q.C.)
.055[1.40] DIA
6.000[152.40]
.250[6.35]
.187[4.74]
.187 TAB (Q.C.)
TERMINAL TYPE
.500[12.70]
INTEGRATED WIRE LEAD
(no exposed conductors)
1.125[28.57]
.812[20.62]
.520[13.20]
1.000[25.40]
.375[9.52]
.994[25.24]
1.120[28.45]
PADDLE
MOUNTING HOLE
Panel Thickness:
.030[.762] min. to
.250[6.35] max.
*Manufacturer reserves the right to change product specification without prior notice.
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
Circuit Designation Chart | 3
1
1
4
1
2
2
2
5
2
5
2
5
3
3
3
6
3
6
3
6
B
4
2
C
4
5
3
D
4
2
2
3
3
1
E
4
1
2
2
6
4
3
3
6
I
J
1
4
1
4
1
4
1
4
2
5
2
5
2
5
2
5
3
6
3
6
3
6
3
6
1
4
1
5
2
6
3
1
4
1
4
2
5
2
5
3
6
3
6
3
4
1
4
5
3
6
1
4
2
5
3
6
T
1
4
1
2
5
2
5
2
3
6
3
6
3
1
4
5
2
5
2
5
6
3
6
3
6
1
Z
CONTACT TERMINAL
Will make contact with switching lever
CONTACT TERMINAL AND SWITCH LEVER
ISOLATED TERMINAL
BULB
Does not make contact with switching lever
REV_SW_TG/LTG_0912
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com