Carling Technologies, Inc.

V-Series
Switch
Product Highlights:
Maximum sealing protection with dual seals around lamps
and rocker stem certified to IP66 & IP68. Optional panel
seals for additional protection.
ŠŠ Silver plated butt contact mechanism provides 50 to
100 thousand electrical cycles and a variety of different
electrical ratings.
ŠŠ Roller pin mechanism does not require lubricants and
allows the switch to withstand extreme temperatures.
ŠŠ The switch base accommodates up to 10 terminals and a
large variety of switch and lighting circuits.
ŠŠ The multi-step mounting wings provide a secure fit for
panel thicknesses of 0.032” thru 0.250” in an industry
standard 0.830” x 1.450” mounting hole.
ŠŠ The switch connector allows the user to preload FQC
terminals for easy assembly to switch base.
ŠŠ Numerous choices of removable rockers allow for style
change without having to retest or re-qualify the switch
base.
ŠŠ Illumination options are endless with bar, oval, and square
lenses available in choices of incandescent, neon and
a wide variety of LEDs including superbrite, megabrite,
flashing and bicolor lighting.
ŠŠ Available with a variety of complimentary mounting
panels, hole plugs, illuminated indicators and boots to
accommodate most any design need.
ŠŠ
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062-1177
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: [email protected] • www.carlingtech.com
CONTURA II
CONTURA III
CONTURA V
Carling Technologies’ fully sealed V-Series Contura switches
are well known for their cutting edge design, high quality,
maximum performance and unmatched reliability. These
switches are a staple in the marine and transportation
industries and have passed a range of environmental,
corrosion, temperature, vibration, shock and sealing tests
including MIL Std 202F, MIL Std 810C, UL 1500, ISO 8846, IEC
60529 and BS 5490 among others, making them one of the
most rugged and reliable switches ever manufactured.
2 | V-Series Contura Sealed Rocker Switches
V-Series Switch
DESIGN FEATURES
MAXIMUM DESIGN OPTIONS
WITH MINIMUM INVENTORIES
Panel redesign is a snap,
requiring no tooling change, with
our removable interchangeable
actuators. A unique balance
between aesthetics and
functionality.
SEALS OUT WATER, DUST
AND DEBRIS
Dual seal protection locks
out elements. Certified to
IP66/IP68 for front panel
components.
CLEAN CONNECTIONS
Offered in both eight and
ten terminal base options.
AMP & Packard compatible
connectors available.
SILVER PLATED BUTT
Contact mechanism
provides 50 to 100
thousand electrical cycles
and a variety of different
electrical ratings.
OPTIONAL PANEL SEAL
Prevents water/dust egress
behind panel.
MULTIPLE LIGHTING OPTIONS
Incandescent lamps & LED lighting. Our
LED illumination is offered in a wide array
of light intensities, colors, as well as dual
level, tri-color, and flashing options.
WITHSTANDS EXTREME
TEMPERATURES
Roller pin mechanism
eliminates the need for
lubricants. Enables switch
to withstand -40°C to
+85°C temperatures.
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
V-Series Contura Sealed Rocker Switches & Illuminated Plug | 3
V-Series Contura Switches
V-Series switches offer countless unique options including choices for ratings, colors, illuminations and symbols. These switches feature removable
actuators in a choice of actuator styles and colors, and are available in single or double pole configurations. The V-Series switches can be illuminated
with either square, oval and/or bar shaped lenses.
Contura II
Contura X
The Contura II actuators are
constructed of thermoplastic
polycarbonate, & are offered with
either a hard nylon overlay, or a
“soft-touch” elastomer overlay.
The Contura II incorporates an
aesthetic design of two rows
of raised “bumps” on the top &
bottom of the rocker.
The raised bracket/bezel on
the Contura X helps prevent
inadvertent actuation of the
rocker, as well as preventing
debris from being trapped
under the actuator. This curved
rocker style is available with a
variety of lenses and legends.
Contura III
Contura XI
The Contura III actuators are
constructed of thermoplastic
polycarbonate, & are offered
with either a hard nylon or a
“soft-touch” elastomer overlay.
The Contura III incorporates
three rows of bars on the top &
bottom of the rocker.
The raised bracket/bezel on
the Contura XI helps prevent
inadvertent actuation of the
rocker, as well as preventing
debris from being trapped under
the actuator. This convex style
rocker is available with a wide
variety of lenses and legends.
Contura IV
Contura XII
The Contura IV’s “Shape to
create a Shape” actuator
supports the designer, by
working with the curves,
contours & advanced styling of
the latest panel designs, flowing
with these advanced curves &
radii. This actuator style fits on
the Contura flush bracket/bezel.
The Contura XII version features
a paddle style actuator with the
raised bracket/bezel of Contura
X and XI. The contoured handle
design provides intuitive
recognition and ease of
operation and is available with
all Contura X and XI lens and
legend offerings.
Contura V
Illuminated Indicator
The symmetrically curved
Contura V actuator provides
the perfect complement to the
Contura IV’s “Shape to create a
Shape” design concept. With its
flush style mounting bracket,
Contura V can be mounted in
between two Contura IV’s, by
itself, or in groups.
The Illuminated Indicator
is offered with removable/
replaceable lamps and
Contura II, III, V, or X styling.
Illumination alerts the operator
of essential system functions or
malfunctions like: oil pressure,
high temperature, fluid levels,
parking brake, or
general system malfunction.
Contura VI (WAVE)
The Contura VI WAVE sealed
rocker switches, when used
in a row, create an uniquely
appealing “wave” design on your
panel. A variety of colors and
finishes are available for both
rocker and wave insert. Contura
VI features bar and oval lenses.
V–Series
Accessories/Options
Carling Technologies also offers
many V-Series accessories
including connectors, mounting
panels, hole plugs, panel seals,
and actuator removal tools.
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
4 | V–Series Contura Sealed Rocker Switches
Electrical
Contact Rating
4VA @ 28VDC (MAX) resistive
15 amps, 125VAC
10 amps, 250VAC
1/2 HP 125-250VAC
20 amps, 4-14VDC
15 amps, 15-28VDC
10A, 14VT
6A, 125VAC L
Dielectric Strength
1500 Volts RMS
Insulation Resistance 50 Megohms
Initial Contact Resistance 10 milliohms max. @ 4VDC
Life
50,000- 100,000 cycles circuit dependent
Contacts
Silver alloy, silver tin-oxide, fine silver
Terminals Brass or copper/silver plate 1/4” (6.3mm) Quick Connect terminations standard. Solder lug, Wire Lead
Mechanical
Endurance
150,000 cycles minimum
circuit dependent
Physical
Lighted
Incandescent - rated 10,000 hours
Neon - rated 25,000 hours
LED - rated 100,000 hours 1/2 life
(LED is internally ballasted for voltages to 24VDC)
Internal
Optional external gasket panel seal
Polyester blend rated to 125°C with a UL flammability rating of 94V0.
Seals
Base
Contura II, III, IV, V, VI
Actuator
Hard Surface: Basic actuator structure molded of thermoplastic polycarbonate with a hard Nylon 66 thermoplastic surface overlay.
Soft Surface: Basic actuator structure molded of thermoplastic polycarbonate with an elastomer overlay.
Contura X, XI, XII
Actuator, VP
Nylon 66 Reinforced rated to 105°C
Lens Polycarbonate rated at 100°C
Actuator Travel (Angular Displacement)
2 position
3 positions
18°
9° from center
Mounting Specifications
Panel Thickness Range
# of gaskets
Acceptable Panel Thickness
0
.030 to .250 (.76mm to 6.35mm)
1
.030 to .109 & .147 to .157
(.76 to 2.77mm & 3.73 to 3.98mm)
Recommended: No gasket with panel thickness of
.032, .062, .093, .125,.187 or .250
.830[21.08]
1.450[36.83]
TEST CUT
HOLE IN
ACTUAL
MATERIAL
SWITCH
MOUNTING HOLE
Agency Certifications
Environmental
Environmental
Sealed version: IP68, in accordance
with IEC 60529, BS 5490, DIN 400 50
& NFC 20 010. This rating applies to
front panel components of the actual
switch only, and signifies protection
against dust and the prolonged effects
of immersion under pressure. The
standard test for immersion under
pressure requires submersion under
one meter of water for 30 minutes. The
V-Series switch has exceeded these
parameters, having been actuated
and illuminated during submersion.
Corrosion
Flowing Mixed Gas (FMG)
Class III 3 year accelerated exposure
per ASTM B-827, B-845
Silver and gold contacts
Operating Temperature -40°C to + 85°C
Vibration 1
Per Mil-Std 202F, Method 204D Test
Condition A 0.06 DA or 10G’s 10-500
Hz. Tested with VCH connector. Test
criteria - No loss of circuit during
test and pre and post test contact
resistance.
Vibration 2
Resonance search
24-50 Hz 0.40 DA
50-2000 ±10 G’s peak
Results Horizontal Axis 3-5 G’s max.
Random
24 Hz
0.06 PSD-Gsq/Hz
60 Hz
0.50
100 Hz
0.50
.
200 Hz
0.025
2000 Hz
0.025
Shock
No loss of circuit during test; <10µ
seconds chatter.
Per Mil-Std 202F, Method 213B, Test
Condition K @ 30G’s. Tested with VCH
connector. Test criteria - No loss of
Salt Spray
circuit during test, pre and post test
contact resistance.
Per Mil-Std 202F, Method 101D, Test
Dust
Condition A, 48 Hrs. Sealed version
only.
Per Mil-Std 810C, Method 510.2 Air
Thermal Shock Velocity 300 ±200 Feet/Min, Test
Duration 16 Hrs.
Per Mil-Std 202F, Method 107F, Test
Moisture Resistance
Cond. A, -55°C to 85°C. Test criteria pre and post test contact resistance
Per Mil-Std 202F, Method 106F, Test
Ignition Protection
Criteria - pre and post test contact
resistance
All Contura switches with sealed
construction meet the requirements
of UL1500/ISO8846 for ignition
protection, in addition to conformance
with EC directive 94/25/EC for marine
products.
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
V–Series Contura II, III, & IV | 5
Dimensional Specifications: in. [mm]
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
6 | V-Series Contura V & VI
Dimensional Specifications: in. [mm]
CONTURA V
CONTURA VI
CONTURA V
SHOWN WITH
BAR LENS
SHOWN WITH OVAL
LENS
SHOWN WITH
LOW PROFILE LOCK
1.950[49.53]
1.922[48.56]
1.922[48.56]
.080[2.03]
1.079[27.40]
1.126
1.479[37.57]
1.550[39.37]
8 TERMINAL BASE
W/BARRIERS
10 TERMINAL BASE
W/BARRIER AND
LAMP TERMINAL
8 TERMINAL BASE
W/O BARRIERS
1.020[25.91]
1.020[25.91]
1.000[25.40]
.505[12.83]
.505[12.83]
.250[6.35]
X
.031[.78]
.250[6.35]
X
.031[.78]
.250[6.35]
X
.031[.78]
.390[9.90]
.960[24.38]
8 TERMINAL BASE
W/O BARRIERS
10 TERMINAL BASE
W/O BARRIERS
7
8
4
1
2
5
2
5
3
6
3
6
8
1
SWITCH SHOWN WITH
VCH CONNECTOR 8
TERMINAL
.960[24.38]
.960[24.38]
8 TERMINAL BASE
W/BARRIERS
2.029[51.53]
.820[20.83]
.820[20.83]
BOTTOM VIEW
TERMINAL
ARRANGEMENT
8 TERMINAL BASE
10
7
4
9
BOTTOM VIEW
TERMINAL
ARRANGEMENT
10 TERMINAL BASE
SWITCH SHOWN WITH
VC1 CONNECTOR 10
TERMINAL
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
V-Series Contura X, XI & XII | 7
Dimensional Specifications: in. [mm]
CONTURA X STYLE
CONTURA XI STYLE
SHOWN WITH RAISED BRACKET
.350[8.89]
.667 [16.94]
1.910[48.51]
CONTURA XII STYLE
SHOWN WITH RAISED
BRACKET AND TWO SQUARE
LENSES
1.910[48.51]
.426[10.82]
.350[8.89]
1.586[40.28]
SHOWN WITH PADDLE
ACTUATOR
1.305[33.15]
1.506[38.25]
1.370[34.79]
1.370[34.79]
8 TERMINAL BASE
W/BARRIERS
1.370[34.79]
10 TERMINAL BASE
W/O BARRIERS
.960[24.38]
8 TERMINAL BASE
W/O BARRIERS
.960[24.38]
.960[24.38]
.780[19.81]
.780[19.81]
.780[19.81]
.250[6.35]
X
.031[.78]
.390[9.90]
.390[9.90]
.820[20.82]
.820[20.82]
10 TERMINAL BASE
W/BARRIERS
8 TERMINAL BASE
W/BARRIERS
SWITCH SHOWN WITH
VCH CONNECTOR
8 TERMINAL
.390[9.90]
.820[20.82]
10 TERMINAL
BASE
W/O BARRIERS
8
1
7
4
8
7
1
4
2
5
2
5
3
6
3
6
BOTTOM VIEW
TERMINAL
ARRANGEMENT
8 TERMINAL BASE
10
9
BOTTOM VIEW
TERMINAL
ARRANGEMENT
10 TERMINAL BASE
SWITCH SHOWN WITH
VC1 CONNECTOR
10 TERMINAL
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
8 | V-Series Contura V & VI
CIRCUIT
CIRCUIT DIAGRAM
CIRCUIT
CIRCUIT DIAGRAM
3
1
3
A
2
3
3
3
3
1
3
4
2
1
6
3
4
6
3
1
4
6
5
3
6
2
5
6
SYMBOL LEGEND
SYM.
2
5
3
4
DEFINITION
DESIGNATES TERMINALS AND CONTACTS
DESIGNATES LAMP LOCATION
DESIGNATES MAINTAINED CIRCUITS
DESIGNATES OTHER POSITION
H
2
3
1
5
3
3
8
5
2
6
G
1
6
S
3
2
1
5
2
7
6
5
2
F
1
4
3
5
2
2
3
R
2
6
6
5
2
E
3
4
M
2
1
3
1
5
D
5
5
2
6
2
3
6
L
2
1
1
5
C
4
4
2
6
2
3
3
K
2
1
1
5
B
3
CIRCUIT DIAGRAM
J
2
2
CIRCUIT
6
DESIGNATES MOMENTARY CIRCUITS
DESIGNATES TWO POSITION CONNECTION
2
5
DESIGNATES EXTERNAL JUMPER PROVIDED
BY CUSTOMER
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
V-Series Contura X, XI & XII | 9
LAMP
CIRCUIT
CIRCUIT DIAGRAM
LAMP
CIRCUIT
+8
+8
A/1
F/6
1
G/7
M/R
2
2
SPECIAL
#3
+1 +3 -4
J/8
2
+3
N/T
1
+8
-6
2
1
+6
1
-7
+6
2
SPECIAL
#4
+3
1
-7
-8
1
2
-7
-7
+1 +3
+6
1
+8
-6
+3
2
-7
+1 +3 -4
P/V
2
-6
1
2
+8
+10
-7
+8
+1 +3
1
K/W
2
U/Y
2
(-)7
CIRCUIT DIAGRAM
CIRCUIT DIAGRAM
11
+6
1
-7
33
1
1
2
5
2
5
3 14
3 14
CIRCUIT
CIRCUIT
17 18
18 10(-)
17
10(-)
J1
J1
11 13
SPECIAL
#1
+3
H/Z
2
11 13
+3
1
+8
C/3
CIRCUIT
L/9
CIRCUIT DIAGRAM
-6
-7
+3
CIRCUIT
+3
LAMP
CIRCUIT
-7
1
-7
E/5
-6
2
+8
1
D/4
CIRCUIT DIAGRAM
-7
+3
B/2
+3
1
-7
LAMP
CIRCUIT
CIRCUIT DIAGRAM
CIRCUIT DIAGRAM
CIRCUIT DIAGRAM
10(-) 1
10(-) 1
J5
J5
8
3
3
2
5
5
1
3
1
3
6 16
6 16
JK
8
8
17 18 10(-)
J4
1
J4
1
2
3 14 15 12
JK
17 18 10(-)
3
2
3 14 15 12
1311
1
5
11 13
3 14
JJ
17 18 10(-)
5
13 11
3 14
JJ
1
1
5
11 13
8
J3
2
NOTE:
J circuits are available for
all non-locking V-Series
styles. Consult factory for
p / n details.
6
8
J3
2
6
5
17 18 10(-)
3
1
33 14
14
8
1
5
CIRCUIT DIAGRAM
8
1
5
-9
JA
17 18 10(-)
J2
-7
JA
2
17 18 10(-)
J2
2
CIRCUIT DIAGRAM
11
13
13 11
17 18
17 18
2
2
8
CIRCUIT
CIRCUIT
1
5
5
SYMBOL LEGEND
SYM.
SYMBOL
LEGENDDEFINITION
SYM.
CIRCUIT
DEFINITION
DESIGNATES TERMINALS AND CONTACTS JA,JJ,JK
DESIGNATES TERMINALS
AND CONTACTS
DESIGNATES LAMP LOCATION
DESIGNATES LAMP LOCATION
J1,J3,J4,J5
J2
CONNECTOR PART #
JC1-01
JC2-01
JC3-01
DESIGNATES TWO POSITION CIRCUIT
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
2
10 | V-Series Contura II & III Sealed Rocker Switches
V 1 D A B T 0 B — A R B 00 — 0 00
1
Series
2
Circuit
4
5
6
Termination Illumination Lamp
3
Rating
7
Lamp
8
Bracket
11
Color
12
Legend
13
14
Legend
Actuator
Orientation Lens Legend
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
2 CIRCUIT
Terminal Connections as viewed
from bottom of switch:
8 terminal
10 terminal
8 - - 7
8- -7
1 - - 4
1- -4
2 - - 5
2- -5
3 - - 6
3- -6
10 - - 9
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
1
2
3
SPDP
2 & 3, 5 & 6 Connected Terminals
1 & 2, 4 & 5
1A
ON
NONE
OFF
2B
(ON)
NONE
OFF
3C
ON
NONE
(OFF)
4D
ON
NONE
ON
5F
ON
NONE
(ON)
6J
ON
OFF
ON
7K
ON
OFF
(ON)
8L
(ON)
OFF
(ON)
SPECIAL CIRCUITS
H*
2&3
2 & 3, 5 & 4
5&4
G*
2 & 3, 5 & 6
2&3
OFF
S
2 & 3, 5 & 6
2&3
1&2
M*
(2 & 3, 5 & 6)
2&3
OFF
R
(2 & 3, 5 & 6)
2&3
1&2
E*
5&6
5&3
5&1
*Jumper between terminals 2 & 5 for circuits H, G, & M are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E
may be used for SP OFF-ON-ON circuit.
3 RATING3
1
B
C
D
E
F
M
N
10
Lens
6,7 LAMP (SAME CODING FOR BOTH SELECTIONS)
1 SERIES
V
Position:
9
Actuator
.4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit 6 only)
.4VA/20A 12V
.4VA/15A 24V
4 TERMINATION / BASE STYLE
8 term
10 term
Termination
1
2
.250 TAB (QC) no barriers
A
B
.250 TAB (QC) with barriers
J
K
.250 TAB (QC) no barriers
3
4
Solder Lug no barriers
C
D
Solder Lug
5
6
Wire Leads no barriers
E
F
Wire Leads
Note: Codes J & K for circuits H, G & M.
5 ILLUMINATION & SWITCH SEALING
0
1 125VAC
4 3V
No lamp
Neon
Incandescent
LED*
2 250VAC
5 6V
6 12V
superbright
Amber
Green
L
F
M
G
N
H
P
J
Red
A
B
C
D
2VDC
6VDC
12VDC
24VDC
7 18V
8 24V
superbright
Red
R
S
T
V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black
B
C
No Seal
One Seal
9 ACTUATOR
No Actuator
Contura II
Contura III
White
W
Y
0
A
B
C
D
3,6
Actuator orientation above terminals:
10 LENS
0 - No Actuator
White
Clear
6
1
7
2
8
3
Gray
G
H
1,4
Z - No Lens
Amber
Green
B
G
C
H
D
J
Red
M
N
P
Blue
T
U
V
E
F
R
S
W
Y
Square lens options available only for Contura II:
9
A
4
5
K
L
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
11 ACTUATOR COLOR1 AND TEXTURE
Jumper
No
No
Yes T2 to 5
No
No
No
No
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Actuator Lens position
Lamp wired to
Sealed
Unsealed Lamps
when Illuminated
Terminals
S
0
NONE
A
1
#1
Independent
8+ 7B
2
#1
Down
3+ 7C
3
#2
Up
3+ 7D
4
#1
Down
3+ 7&# 2
Down
1+ 7E
5
#1
Up
1+ 7&# 2
Up
3+ 7F
6
#1
Independent
8+ 7&# 2
Up
3+ 6G
7
#1
Independent
8+ 7&# 2
Up
3+ 7H
Z
#2
Independent
8+ 7U
Y
#1
Independent
8+ 7&# 2
Independent
10+ 9Selections for Single Pole Switches Only:
J
8
#1
Down
3+ 8&# 2
Independent
6+ 7K
W
#1
Independent
8+ 7&# 2
Independent
6+ 7Selections for Double Pole Switches Only:
L
9
#1
Down
3+ 6M
R
#2
Up
3+ 6N
T
#1
Down
3+ 6&# 2
Down
1+ 4V
#1
Up
1+ 4P
&# 2
Up
3+ 6-
0 - No Actuator
BlackGray Red
White
Soft Surface
BGRW
Hard Surface
CHSY
12 ACTUATOR LENS OR BODY LEGENDS2
11 ON
OFF
12 OFF
ON
13 |
O
14 O
|
15 O O
FN
F
16 O O
FN
F
17 O |
18 | O
For additional legend options & codes, see pages 54-65 of the Carling Transportation catalog
13 LEGEND ORIENTATION
0
1
2
3
4
ARCMC-100
MC
No legend (used with codes 11-18 in selection 12)
Orientation 1
Orientation 2
Orientation 3
ORIENTATION 4
Orientation 4
ORIENTATION OF
ACTUATOR/LENS IN PANEL
ORIENTATION 1
ORIENTATION 2
A9CE3-1E5
A9C45-200
E3
AC
E5
SLEEPER
LIGHTS
45
AZCAC-100
ORIENTATION 3
14 ACTUATOR LENS LEGEND
00
No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must be
specified in selection 12; body legend specified in selection 14.
For legend options & codes, see pages 54-65 of the Carling Transportation catalog
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1
Custom colors are available. Consult factory.
2
Body legends not available on Soft surface actuators; White imprinting is standard on
black actuators; Black imprinting is standard on white, red and gray actuators; Custom
colors are available, consult factory.
3
Additional ratings available. See page 19.
4
Contura II available with two square lenses. Consult factory for details.
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
V-Series Contura II & III Locking Sealed Rocker Switches | 11
V 1 D A S W 0 B — A Z E 00 — 0
1
Series
2
Circuit
4
5
6
Termination Illumination Lock
3
Rating
7
Lamp
8
Bracket
11
Function
12
Legend
13
Legend
Orientation
Lamp above terminals 3 & 6 end of switch
2 CIRCUIT
Terminal Connections as viewed
from bottom of switch:
8 terminal
10 terminal
8 - - 7
8- -7
1 - - 4
1- -4
2 - - 5
2- -5
3 - - 6
3- -6
10 - - 9
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
1
2
3
SPDP
2 & 3, 5 & 6 Connected Terminals
1 & 2, 4 & 5
1A
ON
NONE
OFF
2B
(ON)
NONE
OFF
3C
ON
NONE
(OFF)
4D
ON
NONE
ON
5F
ON
NONE
(ON)
6J
ON
OFF
ON
7K
ON
OFF
(ON)
8L
(ON)
OFF
(ON)
SPECIAL CIRCUITS
H*
2&3
2 & 3, 5 & 4
5&4
G*
2 & 3, 5 & 6
2&3
OFF
S
2 & 3, 5 & 6
2&3
1&2
M*
(2 & 3, 5 & 6)
2&3
OFF
R
(2 & 3, 5 & 6)
2&3
1&2
E*
5&6
5&3
5&1
*Jumper between terminals 2 & 5 for circuits H, G, & M are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E
may be used for SP OFF-ON-ON circuit.
3 RATING14
1
B
C
D
E
F
M
N
10
Lens
7 LAMP
1 SERIES
V
Position:
9
Actuator
Note: Codes J & K for circuits H, G & M.
2 250VAC
5 6V
6 12V
superbright
Amber
Green
L
F
M
G
N
H
P
J
Red
A
B
C
D
2VDC
6VDC
12VDC
24VDC
7 18V
8 24V
superbright
Red
R
S
T
V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black
B
C
No Seal
One Seal
White
W
Y
Gray
G
H
9 HARD SURFACE ACTUATOR1
Contura II
Black
A
Grey
B
Red
G
White
H
Contura III
C
D
E
F
3,6
Actuator orientation above terminals:
10 LENS
Z - No Lens
White
Clear
8
3
Amber
D
Green
J
Red
P
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
.4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit 6 only)
.4VA/20A 12V
.4VA/15A 24V
4 TERMINATION / BASE STYLE
8 term
10 term
Termination
1
2
.250 TAB (QC) no barriers
A
B
.250 TAB (QC) with barriers
J
K
.250 TAB (QC) no barriers
3
4
Solder Lug no barriers
C
D
Solder Lug
5
6
Wire Leads no barriers
E
F
Wire Leads
0
1 125VAC
4 3V
No lamp
Neon
Incandescent
LED*
1,4
Blue
V
11 ACTUATOR LOCK FUNCTION AND COLOR1
Jumper
No
No
Yes T2 to 5
No
No
No
No
5 ILLUMINATION & SWITCH SEALING
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Actuator Lens position
Lamp wired to
Sealed
Unsealed Lamps
when Illuminated
Terminals
S
0
NONE
C
3
#2
Up
3+ 7H
Z
#2
Independent
8+ 7Selections for Double Pole Switches Only:
R
#2
Up
3+ 6M
Lock Color Match Actuator
Black White Red
Safety Orange
12 ACTUATOR LENS OR BODY LEGEND2
00 - No Legend
21
22
OFF ON
25 O
F
F
Lock above terminals 1 & 4 end of switch.
Wlock
23
26 O
N
O
27 O
24
I
28 I
For additional legend options & codes, see pages 54-65 of the Carling Transportation catalog
ORIENTATION OF
ACTUATOR/LENS IN PANEL
13 LEGEND ORIENTATION
0
1
2
3
4
45
6 LOCK
Up
Down
Up & Down Center3
A
HR1
BJ S2
CKT 3
DL V4
E M W5
No legend (used with codes 21-28 in selection 12)
Orientation 1
Orientation 2
Orientation 3
Orientation 4
ORIENTATION 1
ORIENTATION 4
AZC45-1
ORIENTATION 2
AZC45-2
45
ORIENTATION 3
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1
Custom colors are available. Consult factory.
2
White imprinting is standard on black actuators; Black imprinting is standard on
white, red and gray actuators; Custom colors are available, consult factory.
3
Only available with 3 position circuits. Center OFF and special circuits only available
with center position lock function.
4
Additional ratings available. See page 19.
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
12 | V-Series Contura IV Sealed Rocker Switches
V 1 D A B T 0 B — E R C 00 — 0 00
1
Series
2
Circuit
4
5
6
Termination Illumination Lamp
3
Rating
7
Lamp
8
Bracket
10
Lens
11
Color
12
Legend
13
14
Legend
Actuator
Orientation Lens Legend
6,7 LAMP (same coding for both selections)
1 SERIES
V
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
2 CIRCUIT
Terminal Connections as viewed
from bottom of switch:
8 terminal
10 terminal
8 - - 7
8- -7
1 - - 4
1- -4
2 - - 5
2- -5
3 - - 6
3- -6
10 - - 9
Position:
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
1
2
3
SPDP
2 & 3, 5 & 6 Connected Terminals
1 & 2, 4 & 5
1A
ON
NONE
OFF
2B
(ON)
NONE
OFF
3C
ON
NONE
(OFF)
4D
ON
NONE
ON
5F
ON
NONE
(ON)
6J
ON
OFF
ON
7K
ON
OFF
(ON)
8L
(ON)
OFF
(ON)
SPECIAL CIRCUITS
H*
2&3
2 & 3, 5 & 4
5&4
G*
2 & 3, 5 & 6
2&3
OFF
S
2 & 3, 5 & 6
2&3
1&2
M*
(2 & 3, 5 & 6)
2&3
OFF
R
(2 & 3, 5 & 6)
2&3
1&2
E*
5&6
5&3
5&1
*Jumper between terminals 2 & 5 for circuits H, G, & M are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E
may be used for SP OFF-ON-ON circuit.
3 RATING
4
1
B
C
D
E
F
M
N
9
Actuator
.4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit 6 only)
.4VA/20A 12V
.4VA/15A 24V
4 TERMINATION / BASE STYLE
8 term
10 term
Termination
1
2
.250 TAB (QC) no barriers
A
B
.250 TAB (QC) with barriers
J
K
.250 TAB (QC) no barriers
3
4
Solder Lug no barriers
C
D
Solder Lug
5
6
Wire Leads no barriers
E
F
Wire Leads
Note: Codes J & K for circuits H, G & M.
5 ILLUMINATION & SWITCH SEALING
0
1 125VAC
4 3V
No lamp
Neon
Incandescent
LED*
2 250VAC
5 6V
6 12V
superbright
Amber
Green
L
F
M
G
N
H
P
J
Red
A
B
C
D
2VDC
6VDC
12VDC
24VDC
7 18V
8 24V
superbright
Red
R
S
T
V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black
B
C
No Seal
One Seal
White
W
Y
Gray
G
H
9 ACTUATOR
No Actuator
Contura IV, left orientation
Contura IV, left orientation, laser etched
Contura IV, right orientation
Contura IV, right orientation, laser etched
Actuator orientation above terminals:
10 LENS
0 - No Actuator
Clear
White
1
6
2
7
3
8
4
9
5
A
Z - No Lens
Amber
Green
B
G
C
H
D
J
E
K
F
L
1,4
0
E
T
F
R
3,6
Red
M
N
P
R
S
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
11 ACTUATOR COLOR1,5,6
Jumper
No
No
Yes T2 to 5
No
No
No
No
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Actuator Lens position
Lamp wired to
Sealed
Unsealed Lamps
when Illuminated
Terminals
S
0
NONE
A
1
#1
Independent
8+ 7B
2
#1
Down
3+ 7C
3
#2
Up
3+ 7D
4
#1
Down
3+ 7&# 2
Down
1+ 7E
5
#1
Up
1+ 7&# 2
Up
3+ 7F
6
#1
Independent
8+ 7&# 2
Up
3+ 6G
7
#1
Independent
8+ 7&# 2
Up
3+ 7H
Z
#2
Independent
8+ 7U
Y
#1
Independent
8+ 7&# 2
Independent
10+ 9Selections for Single Pole Switches Only:
J
8
#1
Down
3+ 8&# 2
Independent
6+ 7K
W
#1
Independent
8+ 7&# 2
Independent
6+ 7Selections for Double Pole Switches Only:
L
9
#1
Down
3+ 6M
R
#2
Up
3+ 6N
T
#1
Down
3+ 6&# 2
Down
1+ 4V
#1
Up
1+ 4P
&# 2
Up
3+ 6-
No Actuator 0
Black C
Gray H
Red S
White Y
Blue
T
U
V
W
Y
E
Nickel D
F
Pewter E
12 ACTUATOR LENS OR BODY LEGENDS2
11 ON
OFF
12 OFF
ON
13 |
O
14 O
|
15 O O
FN
F
16 O O
FN
F
17 O |
18 | O
For additional legend options & codes, see pages 54-65 of the Carling Transportation catalog
ORIENTATION OF
ACTUATOR/LENS IN PANEL
13 LEGEND ORIENTATION
0
1
2
3
4
E8C45-100
No legend (used with codes 11-18 in selection 12)
Orientation 1
Orientation 2
Orientation 3
Orientation 4
E3C70-200
F8C45-100
F3C70-200
ORIENTATION 1
ORIENTATION 2
ORIENTATION 4
E8C45-300
F8C45-300
ORIENTATION 3
14 ACTUATOR LENS LEGEND
00
No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must be
specified in selection 12; body legend specified in selection 14.
For legend options & codes, see pages 54-65 of the Carling Transportation catalog
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1
Custom colors are available. Consult factory.
2
White imprinting is standard on black actuators; Black imprinting is standard on white,
red and gray actuators; Custom colors are available, consult factory.
3
Gloss brow is on left side of E actuator and right side of F actuator.
4
Additional ratings available. See page 19.
5
Laser etched rocker only available with lens code Z & actuator colors black, nickel or pewter.
6
Pewter and nickel colors only available with laser etched actuator.
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
V-Series Contura V Sealed Rocker Switches | 13
V 1 D A B T 0 B — G R C 00 — 0 00
1
Series
2
Circuit
4
5
6
Termination Illumination Lamp
3
Rating
7
Lamp
8
Bracket
10
Lens
11
Color
12
Legend
13
14
Legend
Actuator
Orientation Lens Legend
6,7 LAMP (same coding for both selections)
1 SERIES
V
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
2 CIRCUIT
Terminal Connections as viewed
from bottom of switch:
8 terminal
10 terminal
8 - - 7
8- -7
1 - - 4
1- -4
2 - - 5
2- -5
3 - - 6
3- -6
10 - - 9
Position:
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
1
2
3
SPDP
2 & 3, 5 & 6 Connected Terminals
1 & 2, 4 & 5
1A
ON
NONE
OFF
2B
(ON)
NONE
OFF
3C
ON
NONE
(OFF)
4D
ON
NONE
ON
5F
ON
NONE
(ON)
6J
ON
OFF
ON
7K
ON
OFF
(ON)
8L
(ON)
OFF
(ON)
SPECIAL CIRCUITS
H*
2&3
2 & 3, 5 & 4
5&4
G*
2 & 3, 5 & 6
2&3
OFF
S
2 & 3, 5 & 6
2&3
1&2
M*
(2 & 3, 5 & 6)
2&3
OFF
R
(2 & 3, 5 & 6)
2&3
1&2
E*
5&6
5&3
5&1
*Jumper between terminals 2 & 5 for circuits H, G, & M are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E
may be used for SP OFF-ON-ON circuit.
3 RATING
14
1
B
C
D
E
F
M
N
9
Actuator
.4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit 6 only)
.4VA/20A 12V
.4VA/15A 24V
4 TERMINATION / BASE STYLE
8 term
10 term
Termination
1
2
.250 TAB (QC) no barriers
A
B
.250 TAB (QC) with barriers
J
K
.250 TAB (QC) no barriers
3
4
Solder Lug no barriers
C
D
Solder Lug
5
6
Wire Leads no barriers
E
F
Wire Leads
Note: Codes J & K for circuits H, G & M.
5 ILLUMINATION & SWITCH SEALING
0
1 125VAC
4 3V
No lamp
Neon
Incandescent
LED*
2 250VAC
5 6V
6 12V
superbright
Amber
Green
L
F
M
G
N
H
P
J
Red
A
B
C
D
2VDC
6VDC
12VDC
24VDC
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black
B
C
No Seal
One Seal
White
W
Y
No Actuator
Contura V
Contura V, laser etched
0
G
P
10 LENS
Lens style &
location:
#1/ #2
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
0 - No Actuator
White
Clear
6
1
7
2
8
3
9
4
A
5
No Actuator 0
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Actuator Lens position
Lamp wired to
Sealed
Unsealed Lamps
when Illuminated
Terminals
S
0
NONE
A
1
#1
Independent
8+ 7B
2
#1
Down
3+ 7C
3
#2
Up
3+ 7D
4
#1
Down
3+ 7&# 2
Down
1+ 7E
5
#1
Up
1+ 7&# 2
Up
3+ 7F
6
#1
Independent
8+ 7&# 2
Up
3+ 6G
7
#1
Independent
8+ 7&# 2
Up
3+ 7H
Z
#2
Independent
8+ 7U
Y
#1
Independent
8+ 7&# 2
Independent
10+ 9Selections for Single Pole Switches Only:
J
8
#1
Down
3+ 8&# 2
Independent
6+ 7K
W
#1
Independent
8+ 7&# 2
Independent
6+ 7Selections for Double Pole Switches Only:
L
9
#1
Down
3+ 6M
R
#2
Up
3+ 6N
T
#1
Down
3+ 6&# 2
Down
1+ 4V
#1
Up
1+ 4P
&# 2
Up
3+ 6-
Gray
G
H
9 ACTUATOR
Z - No Lens
Amber
Green
B
G
C
H
D
J
E
K
F
L
11 ACTUATOR COLOR1,3,3
Jumper
No
No
Yes T2 to 5
No
No
No
No
7 18V
8 24V
superbright
Red
R
S
T
V
Black C
Gray H
Red S
Red
M
N
P
R
S
Blue
T
U
V
W
Y
White Y
Nickel D
bar
bar/bar
oval
oval/bar
oval/oval
Pewter E
12 ACTUATOR LENS OR BODY LEGENDS2,6
11 ON
OFF
12 OFF
ON
13 |
O
14 O
|
15 O O
FN
F
16 O O
FN
F
17 O |
18 | O
For additional legend options & codes, see pages 54-65 of the Carling Transportation catalog
13 LEGEND ORIENTATION
0
1
2
3
4
No legend (used with codes 11-18 in selection 12)
Orientation 1
Orientation 2
Orientation 3
Orientation 4
ORIENTATION OF
ACTUATOR/LENS IN PANEL
ORIENTATION 1
4G13L
4G
MC
MA
4G
MC
MA
MA3MC
ORIENTATION 4
ORIENTATION 2
3L
4G200
MA1MC
ORIENTATION 3
14 ACTUATOR LENS LEGEND
00
No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must be
specified in selection 12; body legend specified in selection 14.
For legend options & codes, see pages 54-65 of the Carling Transportation catalog
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1
Custom colors are available. Consult factory.
2
White imprinting is standard on black actuators; Black imprinting is standard on white,
red and gray actuators; Custom colors are available, consult factory.
3
Laser Etched rocker only available with lens code Z & actuator colors black, nickel or pewter.
4
Additional ratings available. See page 19.
5
Nickel and Pewter colors only available with laser etched actuator.
6
Consult factory for laser etched lens callout.
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
14 | V-Series Contura IV & V Locking Sealed Rocker Switches
V 1 D A S W 0 B — J Z E 00 — 0
2
Circuit
4
5
6
Termination Illumination Lock
3
Rating
7
Lamp
8
Bracket
11
Function
12
Legend
13
Legend
Orientation
Lamp above terminals 3 & 6 end of switch
Position:
SPDP
1A
4D
6J
7K
8L
9N
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7& 8 for lamp circuit only.
Terminals 9 & 10 are not used with locking style
switches.
1
2 & 3, 5 & 6
ON
ON
ON
ON
(ON)
OFF
2
Connected Terminals
NONE
NONE
OFF
OFF
OFF
NONE
3
1 & 2, 4 & 5
OFF
ON
ON
(ON)
(ON)
ON
3 RATING4
.4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit 6 only)
.4VA/20A 12V
.4VA/15A 24V
4 TERMINATION / BASE STYLE
8 term
10 term
Termination
1
2
.250 TAB (QC) no barriers
A
B
.250 TAB (QC) with barriers
J
K
.250 TAB (QC) no barriers
3
4
Solder Lug no barriers
C
D
Solder Lug
5
6
Wire Leads no barriers
E
F
Wire Leads
Note: Codes J & K for circuits H, G & M.
Jumper
No
No
Yes T2 to 5
No
No
No
No
5 ILLUMINATION & SWITCH SEALING
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Actuator Lens position
Lamp wired to
Sealed
Unsealed Lamps
when Illuminated
Terminals
S
0
NONE
C
3
#2
Up
3+ 7H
Z
#2
Independent
8+ 7Selections for Double Pole Switches Only:
R
#2
Up
3+ 6M
6 LOCK
Lock above terminals 1 & 4 end of switch.
W
low profile lock
Y6
high profile lock
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1
Custom colors are available. Consult factory.
2
White imprinting is standard on black actuators; Black imprinting is standard on
white, red and gray actuators; Custom colors are available, consult factory.
3
Only available with 3 position circuits. Center OFF and special circuits only available
with center position lock function.
4
Additional ratings available. See page 19.
5
Located at T3-6 end of switch.
6
Contura V style only.
0
1 125VAC
4 3V
No lamp
Neon
Incandescent
LED*
2 250VAC
5 6V
6 12V
superbright
Amber
Green
L
F
M
G
N
H
P
J
Red
A
B
C
D
2VDC
6VDC
12VDC
24VDC
7 18V
8 24V
superbright
Red
R
S
T
V
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black
B
C
No Seal
One Seal
White
W
Y
Gray
G
H
9 HARD SURFACE ACTUATOR
CONTURA IV:
Orientation
Left
Black
J
Grey
K
Red
L
Right
N
P
R
CONTURA V:
Black
U
Grey
V
Red
W
10 LENS5
Z - No Lens
White
Clear
B
A
H
G
Amber
C
J
White
M
S
Actuator orientation above terminals: 3,6
1,4
Actuator orientation above terminals: 3,6
1,4
White
Y
Green
D
K
Red
E
L
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
Blue
bar lens
F
oval lens
M
11 ACTUATOR LOCK FUNCTION AND COLOR1
Lock Color Match Actuator
Black White Red
Safety Orange
Gray
Up
Down
Up & Down Center3
A
HR1
BJ S2
CKT 3
DL V4
E M W5
F GN6
12 ACTUATOR LENS OR BODY LEGEND2
00 - No Legend
21
22
OFF ON
25 O
F
F
26 O
N
23
O
27 O
24
I
28 I
For additional legend options & codes, see pages 54-65 of the Carling Transportation catalog
ORIENTATION OF
ACTUATOR/LENS IN PANEL
13 LEGEND ORIENTATION
0
1
2
3
4
ORIENTATION 1
No legend
Orientation 1
Orientation 2
Orientation 3
Orientation 4
JHAY3-100
JHAY3-200
JHAY3-300
ORIENTATION 2
3
Terminal Connections as viewed
from bottom of switch:
8 terminal
10 terminal
8 - - 7
8- -7
1 - - 4
1- -4
2 - - 5
2- -5
3 - - 6
3- -6
10 - - 9
1
B
C
D
E
F
M
N
10
Lens
7 LAMP
1 SERIES
V
2 CIRCUIT
9
Actuator
ORIENTATION 4
1
Series
P
P
P
P
P
P
NHAY3-100
NHAY3-200
NHAY3-300
ORIENTATION 3
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
V-Series Contura VI WAVE Sealed Rocker Switches | 15
V 1 D B G N T B – H A 7 C B AC – 1 00
2
Circuit
3
Rating
4
5
6
Termination Illumination Lamp
7
Lamp
8
Bracket
11
Lens
12
Color
13
Insert
Color
14
Actuator
Lens
15
16
Legend
Actuator
Orientation Lens Legend
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
2 CIRCUIT
Terminal Connections as viewed
from bottom of switch:
8 terminal
10 terminal
8 - - 7
8- -7
1 - - 4
1- -4
2 - - 5
2- -5
3 - - 6
3- -6
10 - - 9
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
1
2
3
SPDP
2 & 3, 5 & 6 Connected Terminals
1 & 2, 4 & 5
1A
ON
NONE
OFF
2B
(ON)
NONE
OFF
3C
ON
NONE
(OFF)
4D
ON
NONE
ON
5F
ON
NONE
(ON)
6J
ON
OFF
ON
7K
ON
OFF
(ON)
8L
(ON)
OFF
(ON)
SPECIAL CIRCUITS
H*
2&3
2 & 3, 5 & 4
5&4
G*
2 & 3, 5 & 6
2&3
OFF
S
2 & 3, 5 & 6
2&3
1&2
M*
(2 & 3, 5 & 6)
2&3
OFF
R
(2 & 3, 5 & 6)
2&3
1&2
E*
5&6
5&3
5&1
*Jumper between terminals 2 & 5 for circuits H, G, & M are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E
may be used for SP OFF-ON-ON circuit.
3 RATING3
1
B
C
D
E
F
M
N
10
Lens
6,7 LAMP (same coding for both selections)
1 SERIES
V
Position:
9
Actuator
.4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit 6 only)
.4VA/20A 12V
.4VA/15A 24V
4 TERMINATION / BASE STYLE
8 term
10 term
Termination
1
2
.250 TAB (QC) no barriers
A
B
.250 TAB (QC) with barriers
J
K
.250 TAB (QC) no barriers
3
4
Solder Lug no barriers
C
D
Solder Lug
5
6
Wire Leads no barriers
E
F
Wire Leads
5 ILLUMINATION & SWITCH SEALING
0
1 125VAC
4 3V
No lamp
Neon
Incandescent
LED*
2 250VAC
5 6V
6 12V
superbright
Amber
Green
L
F
M
G
N
H
P
J
Red
A
B
C
D
2VDC
6VDC
12VDC
24VDC
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black
B
C
No Seal
One Seal
White
W
Y
9 ACTUATOR
0
Gray
G
H
H High Insert
No Actuator
Low Insert
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
0 - No Actuator
White
Clear
7
–
–
3
–
4
A
–
C
Z - No Lens
Amber
Green
C
H
D
J
E
K
F
L
H
Black
S
Gray
Red
13 INSERT COLOR
B
C
D
Red
N
P
R
S
Y
Blue
U
V
W
Y
Bar Lens Translucent
Bar Lens Transparent
Oval Lens Transparent
Oval Lens Translucent
White
N Bright Nickel Plated
S Satin Chrome Plated
T Satin Nickel Plated
W White
Black
Bright Chrome Plated
Satin Chrome Painted
14 ACTUATOR LENS OR BODY LEGENDS2
00 - No Legend this location/No actuator
11 ON
OFF
12 OFF
ON
13 |
O
14 O
|
15 O O
FN
F
16 O O
FN
F
17 O |
18 | O
For additional legend options & codes, see pages 54-65 of the Carling Transportation catalog
Orientation
1
15 LEGEND ORIENTATION
0
1
2
3
4
VTHAACN-MC1MC
No legend (used with codes 11-18 in selection 12)
Orientation 1
Orientation 2
Orientation 3
Orientation 4
VTHA7CN-3M100
VTHWZCB-45146
VTLSZSC-70100
VTLLFHC-A813H
VTLDECC-001MG
16 ACTUATOR LENS LEGEND
Orientation
2
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Actuator Lens position
Lamp wired to
Sealed
Unsealed Lamps
when Illuminated
Terminals
S
0
NONE
A
1
#1
Independent
8+ 7B
2
#1
Down
3+ 7C
3
#2
Up
3+ 7D
4
#1
Down
3+ 7&# 2
Down
1+ 7E
5
#1
Up
1+ 7&# 2
Up
3+ 7F
6
#1
Independent
8+ 7&# 2
Up
3+ 6G
7
#1
Independent
8+ 7&# 2
Up
3+ 7H
Z
#2
Independent
8+ 7U
Y
#1
Independent
8+ 7&# 2
Independent
10+ 9Selections for Single Pole Switches Only:
J
8
#1
Down
3+ 8&# 2
Independent
6+ 7K
W
#1
Independent
8+ 7&# 2
Independent
6+ 7Selections for Double Pole Switches Only:
L
9
#1
Down
3+ 6M
R
#2
Up
3+ 6N
T
#1
Down
3+ 6&# 2
Down
1+ 4V
#1
Up
1+ 4P
&# 2
Up
3+ 6-
L
10,11 LENS4
12 ACTUATOR COLOR
Jumper
No
No
Yes T2 to 5
No
No
No
No
7 18V
8 24V
superbright
Red
R
S
T
V
Orientation
4
1
Series
Orientation
3
3
1
00
No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must be
2
4
specified in selection 12; body legend specified in selection
14.
For legend options & codes, see pages 54-65 of the Carling Transportation catalog
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1
Custom colors are available. Consult factory.
2
White imprinting is standard on black actuators; Black imprinting
is standard on white,
3
red and gray actuators; Custom colors are available, consult factory.
3
Additional ratings available. See page 19.
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
16 | V-Series Contura X, XI & XII Sealed Rocker Switches
V 1 D A B 6 0 1 — 6 P Z 00 — 0 00
2
Circuit
4
5
6
Termination Illumination Lamp
3
Rating
7
Lamp
8
Bracket
Terminal Connections as viewed
from bottom of switch:
8 terminal
10 terminal
8 - - 7
8- -7
1 - - 4
1- -4
2 - - 5
2- -5
3 - - 6
3- -6
10 - - 9
Position:
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
1
2
3
SPDP
2 & 3, 5 & 6 Connected Terminals
1 & 2, 4 & 5
1A
ON
NONE
OFF
2B
(ON)
NONE
OFF
3C
ON
NONE
(OFF)
4D
ON
NONE
ON
5F
ON
NONE
(ON)
6J
ON
OFF
ON
7K
ON
OFF
(ON)
8L
(ON)
OFF
(ON)
SPECIAL CIRCUITS
H*
2&3
2 & 3, 5 & 4
5&4
G*
2 & 3, 5 & 6
2&3
OFF
S
2 & 3, 5 & 6
2&3
1&2
M*
(2 & 3, 5 & 6)
2&3
OFF
R
(2 & 3, 5 & 6)
2&3
1&2
E*
5&6
5&3
5&1
*Jumper between terminals 2 & 5 for circuits H, G, & M are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E
may be used for SP OFF-ON-ON circuit.
3 RATING4
.4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit 6 only)
.4VA/20A 12V
.4VA/15A 24V
4 TERMINATION / BASE STYLE
8 term
10 term
Termination
1
2
.250 TAB (QC) no barriers
A
B
.250 TAB (QC) with barriers
J
K
.250 TAB (QC) no barriers
3
4
Solder Lug no barriers
C
D
Solder Lug
5
6
Wire Leads no barriers
E
F
Wire Leads
Note: Codes J & K for circuits H, G & M.
Jumper
No
No
Yes T2 to 5
No
No
No
No
5 ILLUMINATION & SWITCH SEALING
8
W
L
M
N
9
R
T
P
V
12
Legend
13
14
Legend
Actuator
Orientation Lens Legend
#1
&# 2
#1
&# 2
Down
Independent
Independent
Independent
3+
6+
8+
6+
8777-
#1
#2
#1
&# 2
#1
&# 2
Down
Up
Down
Down
Up
Up
3+
3+
3+
1+
1+
3+
666446-
No lamp
Neon5
Incandescent
LED*
2VDC
6VDC
12VDC
24VDC
0
1 125VAC
4 3V
Red
A
B
C
D
2 250VAC
5 6V
6 12V
superbright
Amber
Green
L
F
M
G
N
H
P
J
7 18V
8 24V
superbright
Red
R
S
T
V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
8 BRACKET COLOR1, PANEL SEAL (EXTERNAL FOAM GASKET)
X & XI w/Flush Bracket
0
1
2
B
C
D
W
Y
Z
G
H
J
# of gaskets
Black
White
Gray
9 ACTUATOR
No Actuator
Contura X
Contura XI
Contura XII
0
Black
1
6
J
Actuator orientation above terminals:
Gray
2
7
K
X, XI, XII w/Raised Bracket
0
1
1
4
2
5
3
6
White
3
8
N
Red
4
9
M
3,6
1,4
10 LENS - ABOVE LAMP #1 TERMINALS 1,4
11 LENS - ABOVE LAMP #2 TERMINALS 3,6
0 - No Actuator
Z - No Lens
Clear White Amber Green Red
Blue
3
8
D
J
P
V
4
9
E
K
R
W
5
A
F
L
S
Y
Lens Style
Bar
One piece Square
Two piece Square*
2
7
C
H
N
U
Two piece Square*
1
6
B
G
M
T
(w/ clear top protective lens)
(w/ smoke top protective lens)
Two piece Square*
(w/ white top protective lens)
* All bottom lenses are molded of opaque material. Consult factory for other lens colors.
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
12 ACTUATOR LENS OR BODY LEGEND2
00 - No Legend this location/No actuator
11 ON 12 OFF
13 I
14 O
OFF ON
O
I
15 O O 16 O O 17 O I 18 I O
F N
N F
F
F
21
22
23
24
OFF ON
O
I
25 O
F
F
26 O
N
27 O
28 I
For additional legend options & codes, see pages 54-65 of the Carling Transportation catalog
ORIENTATION OF
ACTUATOR/LENS IN PANEL
13 LEGEND ORIENTATION3
0
1
2
3
4
No legend (used with codes 11-18 in selection 12)
Orientation 1
Orientation 2
Orientation 3
Orientation 4
6ZZ3G-100
6FFMA-4MC
MA
3G
ORIENTATION 1
ORIENTATION 2
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Actuator Lens position
`
Sealed
Unsealed Lamps
when Illuminated
Terminals
S
0
NONE
A
1
#1
Independent
8+ 7B
2
#1
Down
3+ 7C
3
#2
Up
3+ 7D
4
#1
Down
3+ 7&# 2
Down
1+ 7E
5
#1
Up
1+ 7&# 2
Up
3+ 7F
6
#1
Independent
8+ 7&# 2
Up
3+ 6G
7
#1
Independent
8+ 7&# 2
Up
3+ 7H
Z
#2
Independent
8+ 7U
Y
#1
Independent
8+ 7&# 2
Independent
10+ 9K
11
Lens
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
2 CIRCUIT
J
10
Lens
6,7 LAMP (same coding for both selections)
1 SERIES
V
1
B
C
D
E
F
M
N
9
Actuator
ORIENTATION 4
1
Series
70
G3
A7
MC
6ZZ3G-1A7
MA
6FFMA-3MC
MC
6FZ70-100
ORIENTATION 3
14 ACTUATOR LENS LEGEND
00
No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must be
specified in selection 12; body legend specified in selection 14.
For legend options & codes, see pages 54-65 of the Carling Transportation catalog
Notes: Consult factory to verify horsepower rating for your particular circuit choice.
1
Custom colors are available. Consult factory.
2
White imprinting is standard on black actuators; Black imprinting is standard on white, red & gray actuators; Custom colors are available, consult factory.
3
With 2 square lenses, use sel. 12 for lens above lamp 1, & selection 14 for lens above lamp 2.
4
Additional ratings available. See page 19.
5
Not available with Contura XI rockers.
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
V-Series Contura X Locking Sealed Rocker Switches | 17
V 1 D A S W 0 1 — 1 P B 00 — 0
1
Series
2
Circuit
4
5
6
Termination Illumination Lock
3
Rating
7
Lamp
8
Bracket
11
Function
12
Legend
13
Legend
Orientation
Lamp above terminals 3 & 6 end of switch
2 CIRCUIT
Terminal Connections as viewed
from bottom of switch:
8 terminal
10 terminal
8 - - 7
8- -7
1 - - 4
1- -4
2 - - 5
2- -5
3 - - 6
3- -6
10 - - 9
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
1
2
3
SPDP
2 & 3, 5 & 6 Connected Terminals
1 & 2, 4 & 5
1A
ON
NONE
OFF
4D
ON
NONE
ON
6J
ON
OFF
ON
9N
OFF
NONE
ON
SPECIAL CIRCUITS
H*
2&3
2 & 3, 5 & 4
5&4
G*
2 & 3, 5 & 6
2&3
OFF
S
2 & 3, 5 & 6
2&3
1&2
E*
5&6
5&3
5&1
*Jumper between terminals 2 & 5 for circuits H, G, & M are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit E
may be used for SP OFF-ON-ON circuit.
3 RATING4
1
B
C
D
E
F
M
N
10
Lens
7 LAMP
1 SERIES
V
Position:
9
Actuator
.4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit 6 only)
.4VA/20A 12V
.4VA/15A 24V
4 TERMINATION / BASE STYLE
8 term
10 term
Termination
1
2
.250 TAB (QC) no barriers
A
B
.250 TAB (QC) with barriers
J
K
.250 TAB (QC) no barriers
3
4
Solder Lug no barriers
C
D
Solder Lug
5
6
Wire Leads no barriers
E
F
Wire Leads
Note: Codes J & K for circuits H, G & M.
Jumper
No
No
Yes T2 to 5
No
No
No
No
5 ILLUMINATION & SWITCH SEALING
Lamp above terminals 3 & 6 end of switch.
Positive (+) and negative (-) symbols apply to LED lamps only
Actuator Lens position
Sealed
Unsealed Lamps
when Illuminated
S
0
NONE
C
3
#2
Up
H
Z
#2
Independent
Selections for Double Pole Switches Only:
R
#2
Up
M
Lamp wired to
Terminals
3+
8+
77-
3+
6-
6 LOCK
Lock above terminals 1 & 4 end of switch.
Wlock
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1
Custom colors are available. Consult factory.
2
White imprinting is standard on black actuators; Black imprinting is standard on
white, red and gray actuators; Custom colors are available, consult factory.
3
Located over T1-4 end of switch.
4
Additional ratings available. See page 19.
No lamp
Neon
Incandescent
LED*
2VDC
6VDC
12VDC
24VDC
0
1 125VAC
4 3V
Red
A
B
C
D
2 250VAC
5 6V
6 12V
superbright
Amber
Green
L
F
M
G
N
H
P
J
7 18V
8 24V
superbright
Red
R
S
T
V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
8 RAISED BRACKET COLOR1, PANEL SEAL (EXTERNAL FOAM GASKET)
Black
1
4
No Gasket
One Gasket
White
2
5
Gray
3
6
9 HARD SURFACE ACTUATOR
Black
1
Contura X
Grey
2
Red
3
White
4
Actuator orientation above terminals: 3,6
1,4
10 LENS - ABOVE LAMP #2 TERMINALS 3,6
Z - No Lens
Clear White Amber Green Red
Blue
3
8
D
J
P
V
4
9
E
K
R
W
5
A
F
L
S
Y
Lens Style
Bar
One piece Square
Two piece Square*
2
7
C
H
N
U
Two piece Square*
1
6
B
G
M
T
(w/ clear top protective lens)
(w/ smoke top protective lens)
Two piece Square*
(w/ white top protective lens)
* All bottom lenses are molded of opaque material. Consult factory for other lens colors.
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
11 ACTUATOR LOCK FUNCTION AND COLOR3
Lock Color Match Actuator
Black White Red
Gray
Safety Orange
Up
Down
Up & Down
A
HR
BJ S
CKT
DL V
E MW
F NY
12 ACTUATOR LENS OR BODY LEGEND2
00 - No Legend
21
22
OFF ON
25 O
F
F
26 O
N
23
24
O
27 O
I
28 I
For additional legend options & codes, see pages 54-65 of the Carling Transportation catalog
Orientation 1
13 LEGEND ORIENTATION3
0
1
2
3
4
No legend (used with codes 11-18 in selection 12)
Orientation 1
Orientation 2
Orientation 3
Orientation
Orientation 4
Orientation
2
4
1PM4F-1
45
4F
MC
13DMC-1
18K45-2
Orientation 3
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
18 | V-Series Contura Sealed Rocker Switch Actuators Separately
Reduce inventory levels and cost by stocking actuators and base switches separately.
Contura II, III, IV, V, X, XI, XII Base switches separately: specify V with code selections 2-8 in the ordering schemes.
Contura II, III, IV, V Actuator only: VV with code A or C for selection 9, & with selections 10-14 in the ordering schemes.
Panel Seal: VPS
Contura II, III, IV, V Actuator only: VV with code A, C, E, G or P for selection 9 & with selections 10-14 in the ordering schemes.
Contura X, XI, XII actuators with lenses separately: VV with code selections 9-14 in the ordering schemes.
Contura X & XI actuators without lenses separately:
VVR 6 1 00 1
1
Actuator Separately
4
Actuator
Legend
2
3
Actuator
Lens
Style/Color Opening
5
Legend
Orientation
Black
1
6
Contura X
Contura XI
Gray
2
7
3 LENS OPENING FOR1
1
2
3
4
15 O O 16 O O
F N
N F
F
F
17 O I
J Black
Z No lens
square lens on top/
bar lens on bottom
(Contura X only)
1 Bar lens
21
OFF
22
25 O
F
F
26 O
N
ORIENTATION OF
ACTUATOR/LENS IN PANEL
5 LEGEND ORIENTATION1
ORIENTATION 4
I
28 I
1 TOP OF LENS SEPARATELY
VVT
1 Clear
2 Smoke
top lens
bottom lens
}
ORIENTATION 2
2
Lens
Style
4
Legend
3
Lens
Color
2 LENS STYLE3
1 Bar lens
3 White
two piece
lens assembly
1 piece lens/bar lens are positioned the same as bottom lens for assembly, minus the top lens.
Lenses snap in from bottom.
Notes:
1 If actuator lens opening for 2 bar or 2 square lenses, legend orientation 0,1, or 2 must be chosen.
2 Center of actuator marking not available for Contura XII.
3 Legend is not available for bar style lens.
4 Not recommended with neon lamps.
5 Must also order top piece of 2 piece square lens separately.
2 One Piece Square lens
5
Legend
Orientation
3 Bottom of Two-Piece Square lens5
3 TRANSLUCENT LENS COLOR
1 Clear
2 COLOR
ORIENTATION OF
ACTUATOR/LENS IN PANEL
ORIENTATION 1
1 CONTURA X, XI & XII LENS SEPARATELY
VVL
Contura X, XI & XII actuator lens assembly:
posts mount toward actuator stem
27 O
24
VVL 2 1 00 0
ORIENTATION 2
Contura X, XI & XII top piece of 2-piece lens separately:
actuator stem
O
Contura X, XI & XII actuator lens assembly separately:
ORIENTATION 1
ORIENTATION 3
2
Color
23
ON
6 LEGEND ORIENTATION3
0 No legend
1 Orientation 1
2 Orientation 2
1
Lens Separately
1
Lens Separately
2 Square lens
00 - No Legend
M Red
For additional legend options & codes, see pages 54-65 of the Carling Transportation catalog
18 I O
VVT 1
6
7
Legend
Legend
Orientation
5
Legend
N White
5, 7 LENS OR BODY LEGEND2
14 O
I
No legend
Orientation 1
Orientation 2
Orientation 3
Orientation 4
K Gray
3,4 LENS OPENING FOR
For additional legend options & codes, see pages 54-65 of the Carling Transportation catalog
0
1
2
3
4
4
Lens
Opening
3
Lens
Opening
2 ACTUATOR STYLE & COLOR
Red
4
9
4 ACTUATOR LENS OR BODY LEGEND
00 - No Legend this location
11 ON 12 OFF
13 I
OFF ON
O
2
Style &
Color
1 CONTURA XII ACTUATOR SEPARATELY
VVP
White
3
8
5
One bar lens
One bar lenses
One square lens
two square lens
VVP J 1 Z 21 1 00
1
Actuator
1 CONTURA X & XI ACTUATOR SEPARATELY
VVP
2 ACTUATOR STYLE & COLOR
Contura XII actuators without lenses separately:
2 White
3 Amber
4 Green4
4 LENS OR BODY LEGEND2
00 - No Legend
21
OFF
22
25 O
F
F
26 O
N
ON
23
5 Red
O
27 O
24
6 Blue4
I
28 I
For additional legend options & codes, see pages 54-65 of the Carling Transportation catalog
ORIENTATION OF
ACTUATOR/LENS IN PANEL
5 LEGEND ORIENTATION3
0
1
2
3
4
No legend
Orientation 1
Orientation 2
Orientation 3
Orientation 4
ORIENTATION 1
ORIENTATION 4
ORIENTATION 2
ORIENTATION 3
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
V-Series Contura Sealed Rocker Switch Accessories | 19
Easily integrate Contura products into your system, with Contura Accessories
Q.C. SELECTION GUIDE
Contura ConnectorsPART NO
COMPANY
SERIES
WIRE
RANGE
Q.C.
SELECTION
TIN GUIDE
PLAIN
COMPANY
SERIES
ORIENTATION
MM 2
AWG
WIRE
RANGE
PLATED
BRASS
BRASS
PART NO
(REF)
12
3.0
ORIENTIN
PLAIN
TATION
12010601
(2)16-14
02965471
AWG
MM 2(2)1.0-2.0
PLATED
Q.C.
SELECTION
Q.C.
GUIDE
SELECTION
Q.C.
SELECTION
GUIDE
GUIDE
PACKARD BRASS
BRASS
02965470
16-14 (REF) 1.0-2.0
02965580
B
58 SERIES
WIRE
WIRE
WIRE
PART
NO
PART
NO RANGE
NO RANGE
02965580
12PART 20-18
3.0
02965469
06288318
.5-.8 RANGE
COMPANY
COMPANY
ORIENORIEN02965471
12010601
(2)16-14
(2)1.0-2.0
TIN
TIN
TIN
10
5.0
2
2
PLAIN
SERIES
SERIES
PLAIN 12084590
PLAIN MMAWG
TATIONMM
TATION
AWG
AWG
MM 2
PLATED
PLATED
Q.C.BRASS
SELECTION
GUIDE
BRASS
BRASS
02965470 PLATED
16-14
1.0-2.0
B
12052224
3.0
(REF)
(REF)
BRASS
BRASS (REF)12
BRASS
WIRE
02965469
06288318
20-18
.5-.8
02965580
02965580
12 029655803.0 16-14
12
3.0
12
3.0
PART
NO 12015870
1.0-2.0
COMPANY
SERIES
PACKARD
58 SERIES
RANGE
PACKARD
12010601
12010601
12010601
02965471
(2)16-14
(2)16-14
(2)16-14
02965471
02965471
COMPANY
ORIEN10(2)1.0-2.0
5.0 (2)1.0-2.0
12084590
Q.C. SELECTION
GUIDE
12020035
(2)22-18
(2).5-.8
METRI-PACK
TIN
PACKARD
PACKARD PLAINPACKARD
2 B 1.0-2.0
SERIES
TATION
02965470
02965470
16-14 02965470
16-14
AWG
MM3.0
PLATED
12 1.0-2.016-14
12052224
630 SERIES
58 SERIES
58 SERIESBRASS
58
SERIES
WIRE
12015869
20-18
.5-.8
12015832
(REF)
BRASS
PART
NO20-18
02965469
06288318
02965469
06288318
02965469.5-.8 RANGE
20-18
06288318
.5-.8
20-18
ORIENTATION
(2)1.0-2.0
A
B1.0-2.0
.5-.8
TANG
TANG
B
16-14
1.0-2.0
12015870
12 5.0 20-22
PACKARD
COMPANY 02965580
ORIEN12052222
.35-.5
10
10 3.0
5.0
10
5.0
12084590
12084590
12084590
TIN
TANG SYMBOL
=
SHOWS ORIENTATION OF TANG IN SLOT
PLAIN
SERIES 02965471
TATIONA
12020035
METRI-PACK
(2)22-18
(2).5-.8
12010601
(2)16-14
(2)1.0-2.0
TANG
TANG
TANG
AWG
MM 2 3.0
12052224
12052224
1212052224
3.0 16-12
12
12
3.0
PLATED
1.3-3
BRASS
630 SERIES PACKARD
(REF)
SYMBOL
B
16-14
1.0-2.0
BRASS
60253-2
60253-1
1201583202965470
20-18
.5-.8
12015869
58 SERIES
12015870
12015870
12015870
16-14
1.0-2.016-14
1.0-2.0
16-14
1.0-2.0
AMP
PACKARD
PACKARD02965469
PACKARD
(2) 1.3
20-18 12 (2) 16
.5-.8 3.0
02965580 06288318
250 SERIES
(2)22-18
(2)22-18
A(2).5-.8B
A
12020035
12020035
METRI-PACK
METRI-PACK 12020035
METRI-PACK
12052222(2)22-18
20-22(2).5-.8
.35-.5A (2).5-.8
TANG SYMBOL =
SHOWS ORIENTATION OF TANG IN SLOT
12010601
(2)1.0-2.0
02965471
10 (2)16-14
5.0
12084590
630
SERIES
630 SERIES
630
SERIES
42100-2
.8-2
FASTIN-FASTON
42100-1
12015869
12015869
12015869
20-18
.5-.818-14
20-18
.5-.8
20-18
.5-.8 TANG
12015832
12015832
12015832
PACKARD
16-12
1.3-3
12 16-14
3.0 1.0-2.0
B
02965470 12052224
SYMBOL
58
SERIES
60253-1
60253-2
20-22
20-22
.35-.5
20-22
12052222
12052222 .35-.522-18
12052222
60295-2
.3-.9 TANG .35-.5
60295-1
AMP
SYMBOL
=
TANG
SYMBOL
=
TANG
SYMBOL
= IN SLOT
SHOWS
ORIENTATION
SHOWS
OF TANG
ORIENTATION
SHOWS
OFORIENTATION
TANG IN SLOT
OF TANG IN SLOT
12015870
16-14
1.0-2.0
02965469
06288318
20-18
.5-.8
(2)
16
(2)
1.3
PACKARD
250 SERIESMETRI-PACK
16-12 (2)22-18
1.3-3 16-12
16-12
B 1.3-3
(2).5-.85.0 1.3-3
A
12020035
SYMBOL
SYMBOL
SYMBOL
10 part60253-2
60253-2
60253-2
60253-1
60253-1
AMP Consult
AMP Packard
AMP 12084590
42100-2
FASTIN-FASTON
42100-1
18-14
.8-2 (2)and
NOTE:
Delphi
and/or
Amp
on60253-1
actual
numbers
availability.
630 SERIES
(2)
16
(2)
1.3
(2)
16
1.3
(2)
16
(2)
1.3
TANG
12015869
20-18
.5-.8
12015832
12052224
12
3.0 B
250 SERIES
SERIES trademark
250 SERIESof
B
B
AMP is 250
a 60295-1
registered
AMP Inc.
Harrisburg,
PA
60295-2
22-18
.3-.9
18-14
.8-2 18-14
.8-218-14
.8-2
42100-2
42100-2
FASTIN-FASTON FASTIN-FASTON
42100-1
FASTIN-FASTON
42100-1
42100-1
20-22
.35-.5
12052222
12015870
1.0-2.0 Electrical
Delphi PACKARD
Packard
is a42100-2
registered
trademark
of 16-14
Delphi-Packard
Systems
Warren,
TANG SYMBOL
= Ohio
SHOWS ORIENTATION OF TANG IN SLOT
22-18
.3-.9 22-18
22-18A
.3-.9
60295-2
60295-2
60295-2
60295-1
60295-1 12020035
60295-1
16-12
1.3-3(2).5-.8 .3-.9
(2)22-18
METRI-PACK
SYMBOL
60253-2
60253-1
NOTE: Consult Delphi
Amp on actual part numbers and availability.
AMP
630Packard
SERIES and/or
12015869 (2) 1620-18 (2) 1.3 .5-.8
12015832
.820[20.83]
250
SERIES
NOTE:
Consult
NOTE:
Packard
Consult
and/or
Delphi
NOTE:
Amp
Packard
onConsult
actualand/or
part
Delphi
numbers
Amp
Packard
on actual
and
and/or
availability.
partAmp
numbers
on actual
and part
availability.
AMP
is aDelphi
registered
trademark
of
AMP
Inc.
Harrisburg,
PA
B numbers and availability.
42100-2
FASTIN-FASTON
.35-.5
AMP isPackard
a registered
trademark
is a42100-1
registered
of AMP
AMP
Inc.
trademark
Harrisburg,
is 12052222
a registered
AMP
PA18-14
trademark
Inc.20-22
Harrisburg,
of .8-2
AMP
PAInc. Harrisburg,
Delphi
is AMP
a.820[20.83]
registered
trademark
of ofDelphi-Packard
Electrical
SystemsPA
Warren, TANG
Ohio SYMBOL =
SHOWS ORIENTATION OF TANG IN SLOT
Delphi Packard is a registered
Delphi Packard
trademark
is Delphi
a registered
of
Delphi-Packard
Packard
trademark
is a22-18
registered
Electrical
of
Delphi-Packard
trademark
Systems
of
Electrical
Delphi-Packard
Ohio
SystemsElectrical
Warren, Ohio
Systems Warren, Ohio
.3-.91.3-3Warren,
60295-2
60295-1
16-12
SYMBOL
60253-2
60253-1
AMP
(2) 16 and availability.
(2) 1.3
NOTE: Consult
Delphi Packard and/or Amp on actual part numbers
250 SERIES
.820[20.83] .820[20.83]
.820[20.83]
B
.820[20.83]
.820[20.83]
.820[20.83]
.820[20.83]
AMP is a registered trademark
Inc.
Harrisburg,
PA
18-14
.8-2
42100-2
FASTIN-FASTON
42100-1 of AMP
Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio
22-18
.3-.9
60295-2
60295-1
.820[20.83]
NOTE: Consult.820[20.83]
Delphi Packard and/or Amp on actual part numbers and availability.
AMP is a registered trademark of AMP Inc. Harrisburg, PA
Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio
.920[23.37]
.920[23.37]
PACKARD 630
PACKARD 630
VC1
B
A B
.920[23.37]
.920[23.37]
A
A
.820[20.83]
A
VC1 .920[23.37]
PACKARD 630
A
.920[23.37]
VC1
B
B
A
A
PACKARD
630
PACKARD 630 PACKARD 630
VC1
PACKARD 630
B
VC1
VC1
VC1
B
A
A
A
AMP,58PACKARD 58 AMP, PACKARD 58 AMP, PACKARD
58
AMP, PACKARD
AMP,
58 PACKARD
58 PACKARD
AMP, PACKARD
58
PACKARD
630 AMP,
PACKARD
630
PACKARD 630 VC1
PACKARD 630
VC1
VC1
VC1
.920[23.37]
B
B
B B
.920[23.37]
A
VC2
PACKARD 630
B
A
VC1
.820[20.83]
.770[19.56]
.770[19.56]
.920[23.37]
.920[23.37]
AMP
VC2
VC2
AMP
AMP, PACKARD 58
AMP, PACKARD 58
AMP
VC2
AMP
AMP
AMP
1.170[29.72]
A
VC2
VC2
AMP
5
AMPB
VC2
PACKARD 630
A
VC2
1.170[29.72]
A
A
1.170[29.72]
PACKARD
630
.770[19.56]
.950[24.13]
A
AMP
PACKARD 630
58
VC2
AMP, PACKARD
679
43
B
A
PACKARDB 630
AMP, PACKARD 58
B
B
.950[24.13]
B
10 3
2 1 8
7 4
5
69
10 3
2 VC21 8
7 4
5
69
A
A
A
.950[24.13]
.950[24.13]
PACKARD 630
A
B
B
PACKARD
630
AMP,
58AMP, PACKARD 58
AMP, PACKARD
AMP, PACKARD
58 PACKARD
58
.950[24.13]
1 87 4
4 3 5 23 6 1 2 8
AMP, PACKARD
AMP
AMP 1.466[37.24]
AMP, 1.466[37.24]
PACKARD 58
AMP, PACKARD
58
1.250[31.75]
1.250[31.75]
1.266[32.16]
1.466[37.24]
1.266[32.16]
1.266[32.16]
1.466[37.24]
1.266[32.16]
1.466[37.24]
10 3A 2 1.266[32.16]
1 8
7 458 1.466[37.24]
5 61.466[37.24]
9
10 3 2 1 81.266[32.16]
7 4 5 69
AMP, PACKARD
A
A4
3 A2
1 8
7 58
5 6
1.266[32.16]
1.266[32.16]
1.466[37.24]
AMP, PACKARD 58
1.170[29.72]
1.170[29.72]
1.170[29.72]
PACKARD 630
A
PACKARD
PACKARD
630
630
72 451 5
6 9 .950[24.13]
86 9
3 1.170[29.72]
2
1 8
7
B
AMP
.770[19.56]
.770[19.56]
A
VC2
10 3 10
2 31 82 10
5 36 972 417845 56 96 10
9 37 4
2 15 8 6 9 10 10
3 .920[23.37]
35 62 9 1 VC28 7 4
1 38 2 71 48 10
32 1 2 87 1410 8
AMP, PACKARD 58
.770[19.56]
.770[19.56]
.920[23.37]
.920[23.37]
.920[23.37]VC2
B
.820[20.83]
5
B
PACKARD
630
B
6
B
PACKARD 630
PACKARD 630
AMP, PACKARD 58
7
4
1.250[31.75]AMP, PACKARD
5
6
AMP, PACKARD 58
7
4
5
6
1.250[31.75]
58
630
3 2
1 PACKARD
8
7 4
5 6
PACKARD 630
PACKARD 630
VC1
VC1
VC2
1.250[31.75]
1.266[32.16]
1.466[37.24]
1.466[37.24]
MARKING DETAIL1.266[32.16]
MARKING
MARKING
DETAIL
DETAIL
MARKING BDETAIL
MARKING
MARKING
DETAIL
DETAIL MARKING DETAILMARKING
MARKING
DETAIL
DETAIL MARKING DETAIL
MARKING
MARKING
DETAILDETAIL
MARKING
DETAIL
MARKING
MARKING
DETAIL
DETAIL MARKING DETAIL MARKING DETAIL
.950[24.13]
B MARKING DETAIL
FRONT VIEW
FRONT VIEW
REAR1.466[37.24]
VIEW
FRONT VIEW REAR VIEW FRONT
REAR
VIEW
VIEW
FRONT VIEW
REAR
FRONT
VIEW
VIEW
REAR VIEW FRONTB REAR
VIEW VIEW
FRONT VIEW REAR
FRONT
VIEWVIEW
REAR VIEW
REAR VIEW
B
1.250[31.75]
1.266[32.16]
1.266[32.16]
1.466[37.24]
PACKARD 630
MARKING DETAIL
MARKING
MARKING DETAIL AMP
MARKING
DETAIL
MARKING DETAIL
AMP, PACKARD 58
AMP, PACKARD 58 DETAIL
AMP
AMP, PACKARD 58
AMP, PACKARD 58
MARKING
MARKING
MARKING
MARKING
DETAIL
MARKING
DETAIL
10
3DETAIL
2 1 8
7 REAR
4DETAIL
5 VIEW
69
10 3 DETAIL
2 1 FRONT
8
7 4 DETAIL
5 69
FRONT
VIEW
VIEW MARKING
REAR3 VIEW
FRONT
VIEW
2
1 8
4
5 6
FRONT VIEWVC1
REAR
REAR
FRONT
REAR7 VIEW
VC1
VC1 VIEW
VCHVIEW
VCH
VC2 FRONT VIEW
VC2
VC2 VIEW
VCH
MARKING
DETAIL
MARKING
DETAIL
MARKING
DETAIL
MARKING
DETAIL
MARKING
DETAIL
CONNECTOR HOUSING
CONNECTOR1.466[37.24]
HOUSING
1.250[31.75]
1.266[32.16]
1.466[37.24]CONNECTOR HOUSING
1.266[32.16]
CONNECTOR HOUSING
CONNECTOR
HOUSING
CONNECTOR HOUSING
CONNECTOR HOUSING
CONNECTOR
HOUSING
CONNECTOR HOUSING
VCH
VC2
FRONT VIEW
REAR VIEW
FRONT
VIEW
REAR VIEW
FRONT VIEW
(For AMP terminals
(For
only)
AMP
terminals
(For
only)
AMP terminals only)
VC1VC1
VC2
VCH
CONNECTOR HOUSING
DETAIL
CONNECTOR MARKING
HOUSING
FRONT VIEW
VC1
CONNECTOR HOUSING VC1
CONNECTOR
HOUSING
MARKING
DETAIL
CONNECTOR
(For AMP terminals
only)
FRONT VIEW
MARKING DETAIL
REAR VIEW
MARKING DETAIL
HOUSING
REAR VIEW
(For
AMP terminals only)
VC2
CONNECTOR
HOUSING
VC2
CONNECTOR
HOUSING
(For
AMP terminals
only)
Contura X Boot (P/N VB1-01)
CONNECTOR HOUSING
FRONT VIEW
MARKING DETAIL
CONNECTOR
HOUSING
REAR VIEW
VCH
CONNECTOR HOUSING
Additional V-Series Ratings
VCH
CONNECTOR HOUSING
1 .4VA @ 28VDC Resistive
4 10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, No Agency Listings
1.050[26.67]
1.050[26.67]
1.050[26.67]
1.050[26.67]
5 10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, UL Recognized, CSA Certified
6* 15A 125VAC 1/2 HP, 12(2)A 125 VAC μ T85
VB1-01
VB1-01
VB1-01
7*VB1-01
125VAC
1/2
HP,
12(6)A
2.000[50.80]
2.000[50.80] 1.050[26.67]
2.000[50.80]
X15A
BOOTCONTURA
X BOOT
CONTURA
X BOOT 125 VAC T85
1.050[26.67] CONTURA
CONTURA X BOOT
2.000[50.80]
8*
10A
250VAC,
15A
125VAC,
1/2 HP 125-250VAC, 12(2)A 250 VAC μ T85
1.050[26.67]
9* 10A
250VAC, 15A 125VAC, 1/2 HP 125-250VAC, 12(6)A 250 VAC T85
VB1-01
BCONTURA
15A 24V
2.000[50.80]
X BOOT
VB1-01
.757[19.23]
.757[19.23]
.757[19.23] .757[19.23]
CONTURA X BOOT
2.000[50.80]
C 20A 18V VB1-01
2.000[50.80]
X BOOT
D 20A CONTURA
12V
E 20A 14V, 10A 14VT (circuits 1, 4, A, & D only)
.757[19.23]
F 10A 14V, 6A, 14VT (circuit G only)
G 20A 6V
& V Actuator Removal.757[19.23]
Tool
H 20A 3V
3.99 [101.35]
3.99 [101.35]
3.99 [101.35] .757[19.23]
3.99 [101.35]
L 15A 125 VAC, 10A 250VAC, 1/2 HP 125-250 VAC; 6A 125 VAC L
VRT
M .4VA/20A
12V (combi-contact)
VRT
VRT
ACTUATOR
REMOVAL VRT
TOOL ACTUATOR REMOVAL
.900
[22.86]
ACTUATOR
REMOVAL
ACTUATOR REMOVAL
3.99 [101.35]
(combination
gold/silver
contacts for borderline dry circuit applications)
(For
flush
bracket)
.900 [22.86]
.900 [22.86] TOOL
.900 [22.86]
TOOL
TOOL
(For flush
bracket)
(For flush bracket)
N bracket)
.4VA/15A
24V
(combi-contact)
VRT(For flush
ACTUATOR REMOVAL
(combination
gold/silver contacts for borderline dry circuit applications)
TOOL
.900 [22.86]
TOP
TOP
INSERT POINTS UNDER
ACTUATOR
TOP
Contura II, III, IV
(P/N VRT)
(For AMP terminals only)
CONNECTOR
HOUSING
MARKING
DETAIL
MARKING DETAIL
REAR VIEW
MARKING DETAIL
REAR VIEW
TOP
INSERT POINTS
UNDER
INSERT
POINTS UNDER
INSERT POINTS UNDER
HOLD
FLUSH ON BRACKET
AND PUSH
ACTUATOR IN
ACTUATOR
ACTUATOR
HOLD FLUSH ON BRACKET AND PUSH
HOLD FLUSH ON BRACKET AND HOLD
PUSH FLUSH ON BRACKET AND PUSH
TOP
IN
IN
IN
TOP
TOP
TOP
INSERT POINTS UNDER
ACTUATOR
HOLD FLUSH ON BRACKET AND PUSH
IN
TOP
TOP
(For flush bracket)
3.99 [101.35]
3.99 [101.35]
NOTES
Consult factory to determine availability for individual circuits and their HP rating.
VRT
VRTUL, CSA & VDE certified, require terminations A or B for double pole circuits, & are
* Ratings 6 - 9 are
ACTUATOR REMOVAL
INSERT POINTS UNDER
ACTUATOR
INSERT POINTS ACTUATOR
UNDER
not available
with REMOVAL
illumination
.900 [22.86]
TOOLcircuits 4, 8, D, J, N, & T or with wire lead or solder lug terminations.
.900 [22.86]
ACTUATOR HOLD FLUSH ON BRACKET AND PUSH
TOOL
HOLD FLUSH ON
INBRACKET AND PUSH
(For
bracket)
Circuits 1,
4, flush
A, D,bracket)
H, Mflush
& E are
not available with rating 6 & 8. Rating 7 & 9 only available with circuits
IN
(For
TOP
TOP
1, 4, A & D. Circuits 2, 3, 5, 7, 8, K, L are 1/2 HP 250VAC only with rating 8. Ratings 6 & 7 must
specify lamp code 1 (125VAC neon). Ratings 8 & 9 must specify lamp code 2 (250VAC neon). Rating
L available with circuits 1, 4, A & D only.
TOP
TOP
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
20 | V-Series Contura Sealed Rocker Switch Accessories
Contura Mounting Panels
Dimensional Specifications: in. [mm]
Contura Hole Plug
Dimensional Specifications: in. [mm]
1.450 [36.83]
.830 [21.08]
TEST CUT
HOLE IN
ACTUAL
MATERIAL
VHP
CONTURA II,III HOLE PLUG
1.240 [31.50]
1.820 [46.23]
.430 [10.92]
VHP
CONTURA II,III HOLE PLUG
VH1
STANDARD HOLE PLUG
(No wing serrations)
(With VC1 connector attached)
2.000 [50.80]
VH2
STANDARD HOLE PLUG
(With wing serrations)
1.067 [27.10]
(TYP. FOR VH3 & VH4)
1.928 [48.97]
VH3
CONTURA IV HOLE PLUG
(No wing serrations)
VH4
CONTURA IV HOLE PLUG
(With wing serrations)
DETAIL VIEW
VH1,VH3 & VH5
HOLE PLUGS
(No wing serrations
for ease of removal)
1.020 [25.91]
(TYP. FOR VH5 & VH6)
VH5
CONTURA V HOLE PLUG
(No wing serrations)
VH6
CONTURA V HOLE PLUG
(With wing serrations)
DETAIL VIEW
VH2,VH4 & VH6
HOLE PLUGS
(With wing serrations)
REV_SW_V_0312
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com