A-Series – General Specifications

A-Series – General Specifications
Compact size and well known for its proven reliability, the A-Series
utilizes the hydraulic magnetic principle which provides precise
operation and performance even when exposed to extremely hot
and/or cold application environments. When aesthetics demand a
clean contemporary and functional design, the visi-rocker two-color
actuator can be specified. A rockerguard and push-to-reset bezel
help prevent inadvertent actuation. A specially constructed version
is now available for applications requiring CE markings. The
A-Series is used in many telecommunications and marine applications. In addition, these breakers meet CSA Standard 22.2 No.
100 for the Generator & Welder markets.
1-6 poles (handle), 1-3 poles (rocker). 0.02 - 50 amps, up to 277
VAC or 80 VDC, with a choice of time delays, terminals and actuator colors.
Agency Certifications
UL Recognized
UL Standard 1077
Component Recognition Program
as Protectors Supplementary
(Guide CCN/QVNU2, File E75596)
UL Standard 508
Switches, Industrial Control
(Guide CCN/NRNT2, File E148683)
UL Standard 1500
Protectors, Supplementary for
Marine Electrical & Fuel Systems
(Guide PEQZ2, File E75596)
Ignition Protection
34
UL Listed
UL Standard 489A
Communications Equipment (Guide
CCN/DITT, File E189195)
CSA Accepted
Component Supplementary
Protector under Class 3215 30,
File 047848 0 000 CSA
Standard C22.2 No. 235
TUV Certified
EN60934, under License No.
R72040875
VDE Certified
EN60934, VDE 0642 under File No.
10537
www.carlingtech.com
A-Series – General Specifications
Electrical
Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary Protector.
Notes for Table A:
1
Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector.
2
Same as note 1, except that backup fuse is limited to 80 A maximum.
3
2 pole protector required (with one pole per power line) for: 250/125 VAC, 125/250 VAC and 208Y/120 VAC Power Systems. 1 pole protector required for : 125 VAC,
1Ø Power System.
4
Meets the requirements of CSA 22.2 No. 100-04 - Motors and Generators.
www.carlingtech.com
35
A-Series – General Specifications
Electrical
Table B: Lists UL Recognized, CSA Accepted, VDE & TUV Certified configurations & performance capabilities as a Component
Supplementary Protector.
Notes for Table B:
1
General Purpose Ratings for UL/CSA Only.
2
Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector.
3
Same as note 2, except that backup fuse is limited to 80 A maximum.
4
Meets the requirements of CSA 22.2 No. 100-04 - Motors and Generators.
Table C: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for
Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft
Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors.
A-SERIES TABLE C: UL1500 (Marine Ignition Protected)
CIRCUIT
CONFIGURATION
SERIES
MAX.
RATING
VOLTAGE
CURRENT
RATING
SHORT CIRCUIT
CAPACITY
(AMPS)
WITHOUT
BACKUP FUSE
APPLICATION CODES
FREQUENCY
PHASE
FULL LOAD
AMPS
14 1
DC
---
0.02 - 50
5000
TC1,2,OL1,U1 TC1,2,OL1,U1
32 1
DC
---
0.02 - 50
5000
TC1,2,OL1,U2 TC1,2,OL1,U2
65
DC
---
0.02 - 50
3000
TC1,2,OL1,U1 TC1,2,OL1,U1
125 / 250
50 / 60
12
0.02 - 50
1500
TC1,2,OL1,U1 TC1,2,OL1,U1
250
50 / 60
1
0.02 - 30
1000
TC1,2,OL1,U1 TC1,2,OL1,U1
UL
CSA
Notes for Table C:
1
Available with special catalog number only (consult factory).
2
2 pole protector required (with one pole per power line) for: 250/125 VAC, 125/250 VAC and 208Y/120 VAC Power Systems. 1 pole protector required for : 125 VAC, 1Ø Power System.
Table D: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment
(Guide DITT, File E189195), under UL489A.
Notes for Table C:
1
Parallel Pole Construction
36
www.carlingtech.com
A-Series – General Specifications
Electrical
Maximum Voltage
Current Ratings
Standard Voltage Coils
Auxiliary Switch Rating
Insulation Resistance
Dielectric Strength
Resistance, Impedance
Mechanical
277VAC 50/60 Hz, 80VDC
Standard current coils: 0.100, 0.250,
0.500, 0.750, 1.00, 2.50, 5.00, 7.50,
10.0, 15.0, 20.0, 25.0, 30.0, 35.0,
40.0, 50.0. Other ratings available consult ordering scheme.
DC-6V, 12V; AC-120V, Other ratings
available, consult ordering scheme.
SPDT; 10.1 A - 250VAC,
1.0 A-65VDC/0.5 A - 80 VDC,
0.1A - 125VAC (with gold contacts).
Minimum: 100 Megohms at 500 VDC
UL, CSA - 1500V 60 Hz for one
minute between all electrically isolated terminals. A-Series rocker circuit
breakers comply with the 8mm spacing & 3750V dielectric requirements
from hazardous voltage to operator
accessible surfaces per EN 60950
and VDE 0805.
Values from Line to Load Terminal based on Series Trip Circuit Breaker.
Endurance
Trip Free
Trip Indication
10,000 ON-OFF operations @ 6 per
minute; with rated Current & Voltage.
All A-Series Circuit Breakers will trip
on overload, even when the actuator
is forcibly held in the ON position.
The operating actuator moves positively to the OFF position when an
overload causes the circuit breaker
to trip. When mid-trip handle is specified, the handle moves to the mid
position on electrical trip of the circuit breaker. When mid-trip handle
with alarm switch is specified, the
handle moves to the mid position &
the alarm switch actuates when the
circuit breaker is electrically tripped.
Physical
Number of Poles
1 - 6 Poles (handle) and 1-3 poles
(rocker) at 30 Amps or less. 1 and 2
poles at 31 Amps thru 50 Amps.
Internal Circuit Configurations Series, (with or without auxiliary
switch), Shunt and Relay with current or voltage trip coils, Dual Coil,
Switch Only with or without auxiliary
switch.
Weight
Approximately 65 grams/pole.
(Approximately 2.32 ounces/pole)
Standard Colors
Housing - Black; Actuator- See
Ordering Scheme.
Environmental
Pulse Tolerance Curves
www.carlingtech.com
Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows:
Shock
Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Test Condition “I”.
Instantaneous and ultra-short curves
tested @ 90% of rated current.
Vibration
Withstands 0.060" excursion from
10-55 Hz, and 10 Gs 55-500 Hz, at
rated current per Method 204C, Test
Condition A. Instantaneous and
ultrashort curves tested at 90% of
rated current.
Moisture Resistance
Method 106D; ten 24-hour cycles @
+ 25°C to +65°C, 80-98% RH.56
days @ +85°C, 85% RH.
Salt Spray
Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Thermal Shock
Method 107D, Condition A (Five
cycles @ -55°C to +25°C to +85°C
to +25°C).
Operating Temperature
-40° C to +85° C
37
A-Series Handle UL Recognized – Ordering Scheme
A A 3 – B 0 – 10 – 450 – 1 B 1 – C
1
Series
2
Actuator
3
Poles
4
Circuit
5
Aux/Alarm
Switch
6
Frequency
& Delay
1 SERIES
A
2 ACTUATOR 1
A
Handle, one per pole
B
Handle, one per multipole unit
S
Mid-Trip Handle, one per pole
T
Mid-Trip Handle, one per pole & Alarm Switch
3 POLES
1
One
2
Two
3
4
Three
Four
4 CIRCUIT
A2
Switch Only (No Coil)
B
Series Trip (Current)
C
Series Trip (Voltage)
3
D
Shunt Trip (Current)
E3
Shunt Trip (Voltage)
F3
G3
H3,4
5 AUXILIARY/ALARM SWITCH 5
0
w/o Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
2
S.P.D.T., 0.110 Q.C. Term.
3
S.P.D.T., 0.139 Solder Lug
4
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
5
6 FREQUENCY & DELAY
03
DC 50/60Hz, Switch Only
106 DC Instantaneous
11
DC Ultra Short
12
DC Short
14
DC Medium
16
DC Long
6
50/60Hz Instantaneous
20
21
50/60Hz Ultra Short
22
50/60Hz Short0
24
50/60Hz Medium
26
50/60Hz Long
K3,4
5
6
Five
Six
Relay Trip (Current)
Relay Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
Dual Coil with Relay Trip
Voltage Coil
8
9
S.P.S.T., 0.093 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.110 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
30
31
32
34
36
427
447
467
527
547
567
DC, 50/60Hz Instantaneous
DC, 50/60Hz Ultra Short
DC, 50/60Hz Short
DC, 50/60Hz Medium
DC, 50/60Hz Long
50/60Hz Short, Hi-Inrush
50/60Hz Medium, Hi-Inrush
50/60Hz Long, Hi-Inrush
DC, Short,Hi-Inrush
DC,Medium, Hi-Inrush
DC, Long, Hi-Inrush
6
7
Notes:
1
Actuator Code:
A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.
B: Handle location as viewed from front of breaker:
2 pole - left pole
3 pole - center pole
4 pole - two handles at center poles 5 pole - three handles at center poles
6 pole - four handles at center poles
S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, F, G, H and K.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the
breaker. Available with circuit codes B & C.
2
Switch Only circuits, rated up to 50 amps and 6 poles, and only available with VDE
Certification when tied to a protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps,
select Current Code 630. For 35 - 50 amps, select Current Code 650.
3
Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
4
Consult factory for available Dual Coil options, as special catalog number is required. With
Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require
30VA minimum power to trip and are rated for intermittent duty only.
5
Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A - supplied with
standard half shells. 35-50A - supplied with extended boat (B-Style) half shells.
On multi-pole breakers, one auxilary switch is supplied, mounted in the extreme right pole.
6
Separate pole type voltage coils not rated for continuous duty. Available only with delay
codes 10 and 20.
7
Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA
Accepted & TUV Certified to 50 amps.
8
VDE Certification available with single pole breakers with DC Delay only. UL Recognition
and CSA Accepted available in one and two pole breakers.
9
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30
amps are only available with Terminal Codes 5, 9, G, H, M and Q..
10
Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA
Certification up to 30 amps, but not recommended over 20 amps.
11
Terminal Codes 3, 5, E and H (Bus Type) with VDE, are supplied with Lock Washers, and
Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers.
These breakers are only VDE Certified when the washers are used.
12
Terminal Code L: VDE Certified available up to 12A. UL Recognized & CSA Accepted available up to 30A.
13
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30
amps with VDE Certification and 50 amps with UL Recognition and CSA Accepted, with
Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board)
are available up to 40 amps with UL Recognition and CSA Accepted with Circuit Codes A,
B and C.
14
Terminal Code Q not available with VDE certification.
15
Single pole only.
38
7
Current Rating
8
Terminal
9
Actuator
Color
7 CURRENT RATING (AMPERES)
020
0.020
225
0.250
025
0.025
230
0.300
030
0.030
235
0.350
035
0.035
240
0.400
040
0.040
245
0.450
045
0.045
250
0.500
050
0.050
255
0.550
055
0.055
260
0.600
060
0.060
265
0.650
065
0.065
270
0.700
070
0.070
275
0.750
075
0.075
280
0.800
080
0.080
285
0.850
085
0.085
290
0.900
090
0.090
295
0.950
095
0.095
410
1.000
210
0.100
512
1.250
215
0.150
415
1.500
220
0.200
517
1.750
420
522
527
430
435
440
445
450
455
460
465
470
475
480
485
490
495
610
710
2.000
2.250
2.750
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
10.500
OR VOLTAGE COIL (NOMINAL RATED VOLTAGE)6
A06
6 DC
A32 32 DC
J12
12 AC
A12 12 DC
A48 48 DC
J18
18 AC
A18 18 DC
A65 65 DC
J24
24 AC
A24 24 DC
J06
6 AC
J48
48 AC
8 TERMINAL9
110
Push-On 0.250 Tab (Q.C.)
2
Screw 8-32 w/upturned lugs
11
Screw 8-32 (Bus Type)
3
4
Screw 10-32 w/upturned lugs
11
Screw 10-32 (Bus Type)
5
6
Screw 8-32 w/upturned lugs
and 30° bend
7
Screw 8-32 (Bus Type) and
30° bend
8
Screw 10-32 w/upturned lugs
and 30° bend
9
Screw 10-32 (Bus Type) and
30° bend
B
Screw M5 w/upturned lugs
C
Screw M4 w/upturned lugs
9 ACTUATOR COLOR & LEGEND
Actuator Color
I-O
ON-OFF
White
A
B
Black
C
D
Red
F
G
Green
H
J
Blue
K
L
Yellow
M
N
Gray
P
Q
Orange
R
S
U
Black (short handle)15 T
11
Agency
Approval
10
Mounting/
Barriers
611
711
612
712
613
614
615
616
617
618
620
622
624
625
630
6358
6408
6458
6508
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
35.000
40.000
45.000
50.000
J65
65 AC
K20 120 AC
L40 240 AC
Screw M4 (Bus Type)
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
Screw M5 (Bus Type)
0.250 Q.C./ Solder Lug
M6 Threaded Stud
Push-In Stud
Screw M4 w/upturned lugs
and 30° bend
Screw M4 (Bus Type)
and 30° bend
Printed Circuit Board
Terminals
Push-On 0.110 Tab (Q.C.)
E11
F
G
H11
L12
M11
Q14
R
T11
P13
S13
Dual
1
2
3
4
5
6
7
8
9
Legend Color
Black
White
White
White
White
Black
Black
Black
White
10 MOUNTING/BARRIERS
MOUNTING STYLE
Threaded Inserts, 2 per pole
1
6-32 x 0.195 inches
A
6-32 X 0.195 inches
2
ISO M3 x 5mm
B
ISO M3 x 5mm (multipole only)
Front panel Snap-In, 0.75” wide bezel
5
without Handleguard
6
without Handleguard (multipole only)
Front panel Snap-In, 0.96” wide bezel
7
without Handleguard, 1-pole 0.96" wide;
multipole units have .105" bezel overhang on all sides
8
without Handleguard, 1-pole 0.96" wide;
(multipole only) .105" bezel overhang on all sides
BARRIERS
no
yes
no
yes
no
yes
no
yes
11 AGENCY APPROVAL
C
UL Recognized & CSA Accepted
D
VDE Certified, UL Recognized & CSA Accepted
E
TUV Certified, UL Recognized & CSA Accepted
I
UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted
www.carlingtech.com
A-Series Handle UL489A – Ordering Scheme
A A 1 – B 0 – 14 – 450 – 1 B 1 – M T
1
Series
2
Actuator
3
Poles
5
Aux/Alarm
Switch
4
Circuit
6
Frequency
& Delay
1 SERIES
A
2 ACTUATOR1
A
Handle, one per pole
S
Mid-Trip Handle, one per pole
T
Mid-Trip Handle, one per pole & Alarm Switch
3 POLES2
1 One
2 Two
3 Three
4 Four
4 CIRCUIT
B
Series Trip (Current)
5 AUXILIARY/ALARM SWITCH2
0
w/o Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
2
S.P.D.T., 0.110 Q.C. Term.
3
S.P.D.T., 0.139 Solder Lug
6 FREQUENCY & DELAY
11
DC Ultra Short
12
DC Short
14
DC Medium
16
DC Long
7
8
9
S.P.S.T., 0.110 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
523
543
563
DC, Short,Hi-Inrush
DC, Medium, Hi-Inrush
DC, Long, Hi-Inrush
7 CURRENT RATING (AMPERES)
210
215
220
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
410
512
0.100
0.150
0.200
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
0.850
0.900
0.950
1.000
1.250
415
517
420
522
527
430
435
440
445
450
455
460
465
470
475
480
485
490
495
610
1.500
1.750
2.000
2.250
2.750
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
710
611
711
612
712
613
614
615
616
617
618
620
622
624
625
630
6354
6404
6454
6504
10.500
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
35.000
40.000
45.000
50.000
7
Current Rating
8
Terminal
9
Actuator
Color
8 TERMINAL5
16
Push-On 0.250 Tab (Q.C.)
2
Screw 8-32 w/upturned lugs
37
Screw 8-32 (Bus Type)
4
Screw 10-32 w/upturned lugs
57
Screw 10-32 (Bus Type)
6
Screw 8-32 w/upturned lugs
and 30° bend
7
Screw 8-32 (Bus Type) and
30° bend
8
Screw 10-32 w/upturned lugs
and 30° bend
9 ACTUATOR COLOR
LEGEND
ON-OFF
White
B
Black
D
Red
G
Green
J
Blue
L
Yellow
N
Gray
Q
Orange
S
10
Black (short handle) U
Dual
1
2
3
4
5
6
7
8
9
10
Mounting/
Barriers
9
B
F
G
H
M7
P8
Q9
11
Max. Appl.
Rating
12
Agency
Approval
Screw 10-32 (Bus Type) and
30° bend
Screw M5 w/upturned lugs
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
Screw M5 (Bus Type)
M6 Threaded Stud
Printed Circuit Board
Terminals
Push-In Stud
Legend Color
Black
White
White
White
White
Black
Black
Black
White
10 MOUNTING/BARRIERS
MOUNTING STYLE
Threaded Insert, 2 per pole
1
6-32 x 0.195 inches
A
6-32 X 0.195 inches
2
ISO M3 x 5mm
B
ISO M3 x 5mm (multipole only)
Front panel Snap-In, 0.75” wide bezel
5
without Handleguard
6
without Handleguard (multipole only)
Front panel Snap-In, 0.96” wide bezel
7
without Handleguard, 1-pole 0.96" wide;
multipole units have .105" bezel overhang on all sides
8
without Handleguard, 1-pole 0.96" wide;
(multipole only) .105" bezel overhang on all sides
BARRIERS
no
yes
no
yes
no
yes
no
yes
11 MAXIMUM APPLICATION RATING
M
80 DC
12 AGENCY APPROVAL
T
UL489A LISTED
K
UL489A LISTED, VDE CERTIFIED
J
UL489A LISTED, TUV CERTIFIED
Notes:
1
Actuator Code:
A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.
S: Handle moves to mid-position only upon electrical trip of the breaker.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the
breaker.
2
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right
pole.
3
VDE Certified to 30 amps. UL489A Listed to 50 amps.
4
VDE Certification available with single pole breakers only. UL489A Listing available with
one and two pole breakers.
5
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30
amps are only available with Terminal Codes 5, 9 G, H, M and Q.
6
Terminal Code 1 (Push-On) available up to 25 amps with VDE Certification and 30 amps
with UL489A Listing, but is not recommended over 20 amps.
7
Terminal Codes 3, 5 and H (Bus Type) with VDE, are supplied with Lock Washers, and
Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers.
These breakers are only VDE Certified when the washers are used.
8
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30
amps with VDE Certification and 50 amps with UL489A Listing.
9
Terminal Code Q not available with VDE certification.
10
Single pole only.
www.carlingtech.com
39
A-Series Handle WORLD – Ordering Scheme
A A 3 – B 0 – 14 – 450 – 1 A 1 – P
1
Series
2
Actuator
3
Poles
5
Aux/Alarm
Switch
4
Circuit
6
Frequency
& Delay
1 SERIES
A
2 ACTUATOR 1
A
Handle, one per pole
S
Mid-Trip Handle, one per pole
T
Mid-Trip Handle, one per pole & Alarm Switch
3 POLES
1
One
2
Two
3
4
Three
Four
4 CIRCUIT
A2
Switch Only (No Coil)
B
Series Trip (Current)
C
Series Trip (Voltage)
5 AUXILIARY/ALARM SWITCH
0
w/o Aux Switch
2
S.P.D.T., 0.110 Q.C. Term.
3
S.P.D.T., 0.139 Solder Lug
6 FREQUENCY & DELAY
03
DC 50/60Hz, Switch Only
106 DC Instantaneous
11
DC Ultra Short
12
DC Short
14
DC Medium
16
DC Long
206 50/60Hz Instantaneous
21
50/60Hz Ultra Short
22
50/60Hz Short0
24
50/60Hz Medium
26
50/60Hz Long
D3
E3
H3,4
5
6
Five
Six
Shunt Trip (Current)
Shunt Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
5
4
30
31
32
34
36
427
447
467
527
547
567
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
DC, 50/60Hz Instantaneous
DC, 50/60Hz Ultra Short
DC, 50/60Hz Short
DC, 50/60Hz Medium
DC, 50/60Hz Long
50/60Hz Short, Hi-Inrush
50/60Hz Medium, Hi-Inrush
50/60Hz Long, Hi-Inrush
DC, Short,Hi-Inrush
DC,Medium, Hi-Inrush
DC, Long, Hi-Inrush
7
Current Rating
8
Terminal
7 CURRENT RATING (AMPERES)
210
0.100
285
0.850
215
0.150
290
0.900
220
0.200
295
0.950
225
0.250
410
1.000
230
0.300
512
1.250
235
0.350
415
1.500
240
0.400
517
1.750
245
0.450
420
2.000
250
0.500
522
2.250
255
0.550
527
2.750
260
0.600
430
3.000
265
0.650
435
3.500
270
0.700
440
4.000
275
0.750
445
4.500
280
0.800
450
5.000
40
455
460
465
470
475
480
485
490
495
610
710
611
711
612
712
8 TERMINAL9
110
Push-On 0.250 Tab (Q.C.)
2
Screw 8-32 w/upturned lugs
11
Screw 8-32 (Bus Type)
3
4
Screw 10-32 w/upturned lugs
11
Screw 10-32 (Bus Type)
5
6
Screw 8-32 w/upturned lugs
and 30° bend
7
Screw 8-32 (Bus Type) and
30° bend
8
Screw 10-32 w/upturned lugs
and 30° bend
9
Screw 10-32 (Bus Type) and
30° bend
B
C
E11
F
G
H11
R
T11
11
Agency
Approval
10
Mounting/
Barriers
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
10.500
11.000
11.500
12.000
12.500
OR VOLTAGE COIL (NOMINAL RATED VOLTAGE)6
A06
6 DC
A32 32 DC
J12
12 AC
A12 12 DC
A48 48 DC
J18
18 AC
A18 18 DC
A65 65 DC
J24
24 AC
A24 24 DC
J06
6 AC
J48
48 AC
9 ACTUATOR COLOR & LEGEND
Actuator Color
I-O
Dual
White
A
1
Black
C
2
Red
F
3
Green
H
4
Blue
K
5
Yellow
M
6
Gray
P
7
Orange
R
8
Notes:
1
Actuator Code:
A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.
S: Handle moves to mid-position only upon electrical trip of the breaker. Available with
circuit codes B, C, D, E, and H.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of
the breaker. Available with circuit codes B & C.
2
Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to a
protected pole (Circuit Code B, C, D or H.), For .01 to 30 amps, select Current Code
630. For 35 - 50 amps, select Current Code 650.
3
Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
4
Consult factory for available Dual Coil options, as special catalog number is required.
With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils
require 30VA minimum power to trip and are rated for intermittent duty only.
5
On multi-pole breakers, one auxilary switch is supplied, mounted in the extreme right pole.
6
Separate pole type voltage coils not rated for continuous duty. Available only with delay
codes 10, 20 & 30.
7
Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized,
CSA Accepted & TUV Certified to 50 amps.
8
Available up to two poles with AC or DC delays.
9
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30
amps are only available with Terminal Codes 5, 9, G and H.
10
Terminal Code 1: TUV Certification up to 30 amps, but not recommended over 20 amps.
11
Terminal Codes 3, 5 , 7, 9, E, G and H (Bus Type) are supplied with Lock Washers.
These breakers are ONLY TUV Certified when the washers are used.
9
Actuator
Color
613
614
615
616
617
618
620
622
624
625
630
6358
6408
6458
6508
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
35.000
40.000
45.000
50.000
J65
65 AC
K20 120 AC
L40 240 AC
Screw M5 w/upturned lugs
Screw M4 w/upturned lugs
Screw M4 (Bus Type)
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
Screw M5 (Bus Type)
Screw M4 w/upturned lugs
and 30° bend
Screw M4 (Bus Type)
and 30° bend
Legend Color
Black
White
White
White
White
Black
Black
Black
10 MOUNTING/BARRIERS
MOUNTING STYLE
Threaded Inserts, 2 per pole
1
6-32 x 0.195 inches
A
6-32 X 0.195 inches
2
ISO M3 x 5mm
B
ISO M3 x 5mm (multipole only)
Front panel Snap-In, 0.75” wide bezel
5
without Handleguard
6
without Handleguard (multipole only)
Front panel Snap-In, 0.96” wide bezel
7
without Handleguard, 1-pole 0.96" wide;
multipole units have .105" bezel overhang on all sides
8
without Handleguard, 1-pole 0.96" wide;
(multipole only) .105" bezel overhang on all sides
BARRIERS
no
yes
no
yes
no
yes
no
yes
11 AGENCY APPROVAL
P
TUV Certified, UL Recognized & CSA Accepted
Q
UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted
www.carlingtech.com
A-Series Sealed Toggle UL Recognized – Ordering Scheme
A M 1 – B 0 – 10 – 450 – 1 0 1 – C
1
Series
2
Actuator
3
Poles
4
Circuit
5
Aux/Alarm
Switch
6
Frequency
& Delay
1 SERIES
A
2 ACTUATOR 1
M
Sealed Toggle, one per unit
3 POLES
1
One
2
Two
3
Three
4 CIRCUIT
A2
Switch Only (No Coil)
B
Series Trip (Current)
C
Series Trip (Voltage)
D3
Shunt Trip (Current)
E3
Shunt Trip (Voltage)
F3
G3
H3,4
5 AUXILIARY/ALARM SWITCH 5
0
w/o Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
2
S.P.D.T., 0.110 Q.C. Term.
3
S.P.D.T., 0.139 Solder Lug
4
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
5
6 FREQUENCY & DELAY
03
DC 50/60Hz, Switch Only
106 DC Instantaneous
11
DC Ultra Short
12
DC Short
14
DC Medium
16
DC Long
206 50/60Hz Instantaneous
21
50/60Hz Ultra Short
22
50/60Hz Short0
24
50/60Hz Medium
26
50/60Hz Long
K3,4
Relay Trip (Current)
Relay Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
Dual Coil with Relay Trip
Voltage Coil
8
9
S.P.S.T., 0.093 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.110 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
30
31
32
34
36
427
447
467
527
547
567
DC, 50/60Hz Instantaneous
DC, 50/60Hz Ultra Short
DC, 50/60Hz Short
DC, 50/60Hz Medium
DC, 50/60Hz Long
50/60Hz Short, Hi-Inrush
50/60Hz Medium, Hi-Inrush
50/60Hz Long, Hi-Inrush
DC, Short,Hi-Inrush
DC,Medium, Hi-Inrush
DC, Long, Hi-Inrush
6
7
Notes:
1
Actuator Code M: Handle location as viewed from front of panel:
2 pole - right pole
3 pole - center pole
2
Switch Only circuits, rated up to 50 amps and 3 poles. For .02 to 30 amps, select
Current Code 630. For 35 - 50 amps, select Current Code 650.
3
Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
4
Consult factory for available Dual Coil options, as special catalog number is required.
With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils
require 30VA minimum power to trip and are rated for intermittent duty only.
5
Auxiliary Switch available on Series Trip & Switch Only circuits, limited to 30 amps.
On multi-pole breakers, one auxilary switch is supplied, mounted in the extreme right
pole.
6
Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20.
7
Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized,
CSA Accepted & TUV Certified to 50 amps.
8
UL Recognition and CSA Certification available on one and two pole breakers.
9
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30
amps are only available with Terminal Codes 5, 9, G, H, M and Q..
10
Terminal Code 1: UL Recognition and CSA Certification up to 30 amps, but not recommended over 20 amps.
11
Terminal Code L : available up to 30A.
12
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 50
amps, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed
Circuit Board) are available up to 40 amps with Circuit Codes A, B and C.
www.carlingtech.com
7
Current Rating
8
Terminal
7 CURRENT RATING (AMPERES)
020
0.020
225
0.250
025
0.025
230
0.300
030
0.030
235
0.350
035
0.035
240
0.400
040
0.040
245
0.450
045
0.045
250
0.500
050
0.050
255
0.550
055
0.055
260
0.600
060
0.060
265
0.650
065
0.065
270
0.700
070
0.070
275
0.750
075
0.075
280
0.800
080
0.080
285
0.850
085
0.085
290
0.900
090
0.090
295
0.950
095
0.095
410
1.000
210
0.100
512
1.250
215
0.150
415
1.500
220
0.200
517
1.750
9
Legend
Plate
420
522
527
430
435
440
445
450
455
460
465
470
475
480
485
490
495
610
710
10
Mounting/
Barriers
2.000
2.250
2.750
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
10.500
OR VOLTAGE COIL (NOMINAL RATED VOLTAGE)6
A06
6 DC
A32 32 DC
J12
12 AC
A12 12 DC
A48 48 DC
J18
18 AC
A18 18 DC
A65 65 DC
J24
24 AC
A24 24 DC
J06
6 AC
J48
48 AC
8 TERMINAL9
110
Push-On 0.250 Tab (Q.C.)
2
Screw 8-32 w/upturned lugs
3
Screw 8-32 (Bus Type)
4
Screw 10-32 w/upturned lugs
5
Screw 10-32 (Bus Type)
6
Screw 8-32 w/upturned lugs
and 30° bend
7
Screw 8-32 (Bus Type) and
30° bend
8
Screw 10-32 w/upturned lugs
and 30° bend
9
Screw 10-32 (Bus Type) and
30° bend
B
Screw M5 w/upturned lugs
C
Screw M4 w/upturned lugs
E
F
G
H
L11
M
Q
R
T
P12
S12
11
Agency
Approval
611
711
612
712
613
614
615
616
617
618
620
622
624
625
630
6358
6408
6458
6508
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
35.000
40.000
45.000
50.000
J65
65 AC
K20 120 AC
L40 240 AC
Screw M4 (Bus Type)
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
Screw M5 (Bus Type)
0.250 Q.C./ Solder Lug
M6 Threaded Stud
Push-In Stud
Screw M4 w/upturned lugs
and 30° bend
Screw M4 (Bus Type)
and 30° bend
Printed Circuit Board
Terminals
Push-On 0.110 Tab (Q.C.)
9 LEGEND PLATE
0
No legend plate
10 MOUNTING/BARRIERS
MOUNTING STYLE
1
Standard Hex Nut
A
Standard Hex Nut (multipole only)
BARRIERS
no
yes
11 AGENCY APPROVAL
C
UL Recognized & CSA Accepted
41
A-Series Rocker UL Recognized – Ordering Scheme
A F 1 – B 0 – 24 – 630 – 2 3 1 – D
1
Series
2
Actuator
3
Poles
4
Circuit
5
Aux/Alarm
Switch
6
Frequency
& Delay
1 SERIES
A
2 ACTUATOR
Two Color Visi-Rocker
C
Indicate ON, vertical legend
D
Indicate ON, horizontal legend
E
Indicate ON, no legend
F
Indicate OFF, vertical legend
G
Indicate OFF, horizontal legend
H
Indicate OFF, no legend
Push-To-Reset, Visi-Rocker
N
Indicate OFF,
vertical legend
O
Indicate OFF,
horizontal legend
P
Indicate OFF,
no legend
Single color
J
Vertical legend
K
Horizontal legend
L
No legend
1
3 POLES 2
1
One
2
Push-To-Reset , Single color
R
Vertical legend
U
Horizontal legend
V
No legend
Two
3
4 CIRCUIT
A3
Switch Only (No Coil)
B
Series Trip (Current)
C
Series Trip (Voltage)
D4
Shunt Trip (Current)
E4
Shunt Trip (Voltage)
F4
G4
H 4, 5
5 AUXILIARY/ALARM SWITCH 6, 7
0
w/o Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
2
S.P.D.T., 0.110 Q.C. Term.
3
S.P.D.T., 0.139 Solder Lug
4
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
5
6 FREQUENCY & DELAY
03
DC 50/60Hz, Switch Only
10 8 DC Instantaneous
11
DC Ultra Short
12
DC Short
14
DC Medium
16
DC Long
8
50/60Hz Instantaneous
20
21
50/60Hz Ultra Short
22
50/60Hz Short
24
50/60Hz Medium
26
50/60Hz Long
K
4, 5
Relay Trip (Current)
Relay Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
Dual Coil with Relay Trip
Voltage Coil
S.P.S.T., 0.093 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.110 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
6
7
8
9
30
31
32
34
36
42
44
46
52
54
56
Three
9
9
9
9
9
DC, 50/60Hz Instantaneous
DC, 50/60Hz Ultra Short
DC, 50/60Hz Short
DC, 50/60Hz Medium
DC, 50/60Hz Long
50/60Hz Short, Hi-Inrush
50/60Hz Medium, Hi-Inrush
50/60Hz Long, Hi-Inrush
DC, Short,Hi-Inrush
DC,Medium, Hi-Inrush
DC, Long, Hi-Inrush
Notes:
1
Push-To-Reset actuators have OFF portion of rocker shrouded.
2
Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker
per breaker.
3
Switch Only circuits, rated up to 50 amps & 3 poles, are available with VDE Certification when tied to a protected pole (Circuit
Code B, C, D or H.), For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650.
4
Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
5
Consult factory for Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip
instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only.
6
Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with standard half shells. 30-50A are
supplied with extended boat (B-Style) half shells.
7
On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole.
8
Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 and 20.
9
Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted & TUV Certified to 50
amps.
10
Series Trip current ratings: VDE Certification available with single pole breakers with DC Delay only. UL Recognition & CSA
Accepted available in one and two pole breakers.
11
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal
Codes 5, 9, G, H, M and Q.
12
Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA Accepted up to 30 amps, but not recommended over 20 amps.
13
Terminal Codes 3, 5 E & H (Bus Type) with VDE, are supplied with Lock Washers; Terminal Code M (M6 Threaded Stud)
with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used.
14
VDE Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps.
15
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50
amps with UL Recognition and CSA Accepted, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P
(Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Certification with Circuit Codes A, B and C.
16
Terminal Code Q not available with VDE.
17
Terminal Code S used on voltage coil circuit constructions only.
18
Color shown is visi and legend with remainder of rocker black.
19
Dual = ON-OFF/I-O legend with actuator. None = no legend on actuator
20
Legend on Push-to-reset bezel/shroud is white with single color actuator codes R, & U. Legend on Push-to-reset
bezel/shroud matches Visi-color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through L.
42
7
Current Rating
8
Terminal
9
Actuator
Color
10
Mounting/
Barriers
7 CURRENT RATING (AMPERES)
420
2.000
225
0.250
020
0.020
522
2.250
230
0.300
025
0.025
527
2.750
235
0.350
030
0.030
430
3.000
240
0.400
035
0.035
435
3.500
245
0.450
040
0.040
440
4.000
250
0.500
045
0.045
445
4.500
255
0.550
050
0.050
450
5.000
260
0.600
055
0.055
455
5.500
265
0.650
060
0.060
460
6.000
270
0.700
065
0.065
465
6.500
275
0.750
070
0.070
470
7.000
280
0.800
075
0.075
475
285
0.850
080
0.080
7.500
290
0.900
085
0.085
480
8.000
295
0.950
090
0.090
485
8.500
410
1.000
095
0.095
490
9.000
512
1.250
210
0.100
495
9.500
415
1.500
215
0.150
610 10.000
517
1.750
220
0.200
710 10.500
OR VOLTAGE COIL (NOMINAL RATED VOLTAGE)
J12
12 AC
A32 32 DC
A06
6 DC
J18
18 AC
A48 48 DC
A12 12 DC
J24
24 AC
A65 65 DC
A18 18 DC
J48
48 AC
J06
6 AC
A24 24 DC
8 TERMINAL 11
112
Push-On 0.250 Tab (Q.C.)
2
Screw 8-32 w/upturned lugs
Screw 8-32 (Bus Type)
313
4
Screw 10-32 w/upturned lugs
Screw 10-32 (Bus Type)
513
6
Screw 8-32 w/upturned lugs
and 30° bend
7
Screw 8-32 (Bus Type) and
30° bend
8
Screw 10-32 w/upturned lugs
and 30° bend
9
Screw 10-32 (Bus Type) and
30° bend
B
Screw M5 w/upturned lugs
C
Screw M4 w/upturned lugs
9 ACTUATOR COLOR & LEGEND
Actuator or _______Marking: _______
Visi-Color 12 I-O ON-OFF Dual12
White
A
B
1
Black
C
D
2
Red
F
G
3
Green
H
J
4
Blue
K
L
5
Yellow
M
N
6
Gray
P
Q
7
Orange
R
S
8
E13
F
G
H13
L14
M13
P15
Q16
R
S17
T
11
Agency
Approval
611
711
612
712
613
614
615
616
617
618
620
622
624
625
630
635 10
640 10
645 10
650 10
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
35.000
40.000
45.000
50.000
J65
65 AC
K20 120 AC
L40 240 AC
Screw M4 (Bus Type)
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
Screw M5 (Bus Type)
0.250 Q.C./ Solder Lug
M6 Threaded Studs
Printed Circuit Board
Terminals
Push-In Stud
Screw M4 w/upturned lugs
and 30° bend
Push-On 0.110 Tab (Q.C.)
Screw M4 (Bus Type)
and 30° bend
____Marking Color:
Single Color Visi-Rocker
Black
White
White
n/a
White
Red
White
Green
White
Blue
Black
Yellow
Black
Gray
Black
Orange
10 MOUNTING/BARRIERS20
BARRIERS
STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole
1 6-32 x 0.195 inches
no
A 6-32 X 0.195 inches (multi-pole units only)
yes
2 ISO M3 x 5mm
no
B ISO M3 x 5mm (multi-pole units only)
yes
ROCKERGUARD & PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole
3 6-32 x 0.195 inches
no
C 6-32 x 0.195 inches (multi-pole units only)
yes
4 ISO M3 x 5mm
no
D ISO M3 x 5mm (multi-pole units only)
yes
FRONT PANEL SNAP-IN BRACKET, 0.744” wide bezel
8 without Rockerguard (single pole units only)
no
H with Rockerguard (single pole units only)
no
FRONT PANEL SNAP-IN BRACKET, 0.96” wide bezel
9 without Rockerguard (single pole units only)
no
J with Rockerguard (single pole units only)
no
11 AGENCY APPROVAL
C
UL Recognized & CSA Accepted
D
VDE Certified, UL Recognized & CSA Accepted
E
TUV Certified, UL Recognized & CSA Accepted
I
UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted
www.carlingtech.com
A-Series Rocker UL489A – Ordering Scheme
A F 1 – B 0 – 14 – 450 – 1 3 1 – M T
1
Series
2
Actuator
3
Poles
5
Aux/Alarm
Switch
4
Circuit
6
Frequency
& Delay
1 SERIES
A
2 ACTUATOR 1
Two Color Visi-Rocker
C
Indicate ON, vertical legend
D
Indicate ON, horizontal legend
F
Indicate OFF, vertical legend
G
Indicate OFF, horizontal legend
Push-To-Reset, Visi-Rocker
N
Indicate OFF,
vertical legend
O
Indicate OFF,
horizontal legend
Single color
J
Vertical legend
K
Horizontal legend
Push-To-Reset , Single color
R
Vertical legend
U
Horizontal legend
3 POLES2
1 One
2 Two
3 Three
6 FREQUENCY & DELAY
11
DC Ultra Short
12
DC Short
14
DC Medium
16
DC Long
7
8
9
S.P.S.T., 0.110 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
52
54
56
DC, Short,Hi-Inrush
DC, Medium, Hi-Inrush
DC, Long, Hi-Inrush
7 CURRENT RATING (AMPERES)
210
215
220
225
230
235
240
245
250
255
260
265
270
275
280
285
290
295
410
512
0.100
0.150
0.200
0.250
0.300
0.350
0.400
0.450
0.500
0.550
0.600
0.650
0.700
0.750
0.800
0.850
0.900
0.950
1.000
1.250
www.carlingtech.com
415
517
420
522
527
430
435
440
445
450
455
460
465
470
475
480
485
490
495
610
1.500
1.750
2.000
2.250
2.750
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
710
611
711
612
712
613
614
615
616
617
618
620
622
624
625
630
6355
6405
6455
6505
8
Terminal
9
Actuator
Color
8 TERMINAL5
16
Push-On 0.250 Tab (Q.C.)
2
Screw 8-32 w/upturned lugs
37
Screw 8-32 (Bus Type)
4
Screw 10-32 w/upturned lugs
57
Screw 10-32 (Bus Type)
6
Screw 8-32 w/upturned lugs
and 30° bend
7
Screw 8-32 (Bus Type) and
30° bend
8
Screw 10-32 w/upturned lugs
and 30° bend
9 ACTUATOR COLOR & LEGEND
Actuator or
Marking
Visi-Color 10
ON-OFF
Dual 10
White
B
1
Black
D
2
Red
G
3
Green
J
4
Blue
L
5
Yellow
N
6
Gray
Q
7
Orange
S
8
4 CIRCUIT
B
Series Trip (Current)
5 AUXILIARY/ALARM SWITCH3
0
w/o Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
2
S.P.D.T., 0.110 Q.C. Term.
3
S.P.D.T., 0.139 Solder Lug
7
Current Rating
10.500
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
35.000
40.000
45.000
50.000
10
Mounting/
Barriers
9
B
F
G
H
M7
P8
Q9
11
Max. Appl.
Rating
12
Agency
Approval
Screw 10-32 (Bus Type) and
30° bend
Screw M5 w/upturned lugs
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
Screw M5 (Bus Type)
M6 Threaded Stud
Printed Circuit Board
Terminals
Push-In Stud
Marking Color:
Single Color
Visi-Rocker
Black
White
White
n/a
White
Red
White
Green
White
Blue
Black
Yellow
Black
Gray
Black
Orange
10 MOUNTING/BARRIERS 11
STANDARD ROCKER BEZEL
BARRIERS
Threaded Insert, 2 per pole
1
6-32 x 0.195 inches
no
A
6-32 X 0.195 inches (multi-pole units only)
yes
2
ISO M3 x 5mm
no
B
ISO M3 x 5mm (multi-pole units only)
yes
ROCKERGUARD & PUSH-TO-RESET BEZEL
Threaded Insert, 2 per pole
3
6-32 x 0.195 inches
no
C
6-32 x 0.195 inches (multi-pole units only)
yes
4
ISO M3 x 5mm
no
D
ISO M3 x 5mm (multi-pole units only)
yes
FRONT PANEL SNAP-IN BRACKET, 0.744” [18.90mm] wide bezel
8
without Rockerguard (single pole units only)
no
H
with Rockerguard (single pole units only)
no
FRONT PANEL SNAP-IN BRACKET, 0.96” [24.48mm] wide bezel
9
without Rockerguard (single pole units only)
no
J
with Rockerguard (single pole units only)
no
11 MAXIMUM APPLICATION RATING
M
80 DC
12 AGENCY APPROVAL
T
UL489A Listed
K
UL489A Listed, VDE Certified
J
UL489A Listed, TUV Certified
Notes:
1
Push-To-Reset actuators have OFF portion of rocker shrouded.
2
Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or
mixed poles, and have one rocker per breaker.
3
Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with standard half
shells. 30-50A are supplied with extended boat (B-Style) half shells.
4
VDE Certification available with single pole breakers only. UL489A Listing available with one
and two pole breakers.
5
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps
are only available with Terminal Codes 5, 9, G, H, M and Q.
6
Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30
amps with UL489A Listing, but is not recommended over 20 amps.
7
Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers,
and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers.
These breakers are only TUV or VDE Certified when the washers are used.
8
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps
with VDE Certification and 50 amps with UL489A Listing.
9
Terminal Code Q not available with VDE certification.
10
Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend.
11
Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U.
Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes N
& O. Rockerguard available with actuator codes C through K.
43
A-Series Flat Rocker UL Recognized – Ordering Scheme
A 1 1 – B 0 – 24 – 630 – 2 3 1 – E
1
Series
2
Actuator
3
Poles
4
Circuit
5
Aux/Alarm
Switch
6
Frequency
& Delay
1 SERIES
A
2 ACTUATOR
Two Color Visi-Rocker
1
Indicate OFF, vertical legend
2
Indicate OFF, horizontal legend
Single color
3
Vertical legend
4
Horizontal legend
Push-To-Reset, Visi-Rocker
5
Indicate OFF, vertical legend
6
Indicate OFF, horizontal legend
Push-To-Reset , Single color
7
Vertical legend
8
Horizontal legend
1
3 POLES 2
1
One
2
Two
3
4 CIRCUIT
A3
Switch Only (No Coil)
B
Series Trip (Current)
C
Series Trip (Voltage)
D4
Shunt Trip (Current)
E4
Shunt Trip (Voltage)
F4
G4
H 4, 5
5 AUXILIARY/ALARM SWITCH 6, 7
0
w/o Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
2
S.P.D.T., 0.110 Q.C. Term.
3
S.P.D.T., 0.139 Solder Lug
4
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
5
6 FREQUENCY & DELAY
03
DC 50/60Hz, Switch Only
10 8 DC Instantaneous
11
DC Ultra Short
12
DC Short
14
DC Medium
16
DC Long
8
50/60Hz Instantaneous
20
21
50/60Hz Ultra Short
22
50/60Hz Short
24
50/60Hz Medium
26
50/60Hz Long
K 4, 5
Three
Relay Trip (Current)
Relay Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
Dual Coil with Relay Trip
Voltage Coil
8
9
S.P.S.T., 0.093 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.110 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
30
31
32
34
36
42
44
46
52
54
56
DC, 50/60Hz Instantaneous
DC, 50/60Hz Ultra Short
DC, 50/60Hz Short
DC, 50/60Hz Medium
DC, 50/60Hz Long
50/60Hz Short, Hi-Inrush
50/60Hz Medium, Hi-Inrush
50/60Hz Long, Hi-Inrush
DC, Short,Hi-Inrush
DC,Medium, Hi-Inrush
DC, Long, Hi-Inrush
6
7
9
9
9
9
9
Notes:
1
Push-To-Reset actuators have OFF portion of rocker shrouded.
2
Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles,
and have one rocker per breaker.
3
Switch Only circuits, rated up to 50 amps & 3 poles. For .02 to 30 amps, select Current Code 630. For
35 - 50 amps, select Current Code 650.
4
Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
5
Consult factory for Dual Coil options, as special catalog number is required. With Shunt construction,
Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and
are rated for intermittent duty only.
6
Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with standard half
shells. 30-50A are supplied with extended boat (B-Style) half shells.
7
On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole.
8
Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 & 20.
9
Available with Circuit Codes B & D only. UL Recognized, CSA Accepted & TUV Certified to 50 amps.
10
UL Recognition, CSA Acceptance & TUV Certification available in one and two pole breakers.
11
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only
available with Terminal Codes 5, 9, G, H, M and Q.
12
Terminal Code 1: Available up to 30 amps, but not recommended over 20 amps.
13
Terminal Codes 3, 5 E & H (Bus Type) with TUV, are supplied with Lock Washers; Terminal Code M
(M6 Threaded Stud) with TUV is supplied with Lock and Flat Washers. These breakers are only TUV
Certified when the washers are used.
14
TUV Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps.
15
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 50 amps with UL
Recognition, CSA Accepted & TUV Certification, with Circuit Codes A, B and C. Two pole breakers with
Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA
Accepted with Circuit Codes A, B and C.
16
Terminal Code S used on voltage coil circuit constructions only.
17
Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O legend.
18
Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. Legend on
Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes 5 & 6.
19
Recessed “off-side” available with actuator codes 1, 2, 3 & 4. Legends on rocker are available in ink
stamping only.
44
7
Current Rating
8
Terminal
9
Actuator
Color
10
Mounting/
Barriers
7 CURRENT RATING (AMPERES)
420
2.000
225
0.250
020
0.020
522
2.250
230
0.300
025
0.025
527
2.750
235
0.350
030
0.030
430
3.000
240
0.400
035
0.035
435
3.500
245
0.450
040
0.040
440
4.000
250
0.500
045
0.045
445
4.500
255
0.550
050
0.050
450
5.000
260
0.600
055
0.055
455
5.500
265
0.650
060
0.060
460
6.000
270
0.700
065
0.065
465
6.500
275
0.750
070
0.070
470
7.000
280
0.800
075
0.075
475
285
0.850
080
0.080
7.500
290
0.900
085
0.085
480
8.000
295
0.950
090
0.090
485
8.500
410
1.000
095
0.095
490
9.000
512
1.250
210
0.100
495
9.500
415
1.500
215
0.150
610 10.000
517
1.750
220
0.200
710 10.500
OR VOLTAGE COIL (NOMINAL RATED VOLTAGE)
J12
12 AC
A32 32 DC
A06
6 DC
J18
18 AC
A48 48 DC
A12 12 DC
J24
24 AC
A65 65 DC
A18 18 DC
J48
48 AC
J06
6 AC
A24 24 DC
8 TERMINAL 11
112
Push-On 0.250 Tab (Q.C.)
2
Screw 8-32 w/upturned lugs
13
Screw 8-32 (Bus Type)
3
4
Screw 10-32 w/upturned lugs
13
Screw 10-32 (Bus Type)
5
6
Screw 8-32 w/upturned lugs
and 30° bend
7
Screw 8-32 (Bus Type) and
30° bend
8
Screw 10-32 w/upturned lugs
and 30° bend
9
Screw 10-32 (Bus Type) and
30° bend
B
Screw M5 w/upturned lugs
C
Screw M4 w/upturned lugs
9 ACTUATOR COLOR & LEGEND
Actuator or _______Marking: _______
Visi-Color 17 I-O ON-OFF Dual17
White
A
B
1
Black
C
D
2
Red
F
G
3
Green
H
J
4
Blue
K
L
5
Yellow
M
N
6
Gray
P
Q
7
Orange
R
S
8
E13
F
G
H13
L14
M13
P15
Q
R
S16
T
11
Agency
Approval
611
711
612
712
613
614
615
616
617
618
620
622
624
625
630
635 10
640 10
645 10
650 10
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
35.000
40.000
45.000
50.000
J65
65 AC
K20 120 AC
L40 240 AC
Screw M4 (Bus Type)
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
Screw M5 (Bus Type)
0.250 Q.C./ Solder Lug
M6 Threaded Studs
Printed Circuit Board
Terminals
Push-In Stud
Screw M4 w/upturned lugs
and 30° bend
Push-On 0.110 Tab (Q.C.)
Screw M4 (Bus Type)
and 30° bend
____Marking Color:
Single Color Visi-Rocker
Black
White
White
n/a
White
Red
White
Green
White
Blue
Black
Yellow
Black
Gray
Black
Orange
10 MOUNTING/BARRIERS18
BARRIERS
STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole
FLAT ROCKER ACTUATOR
1 6-32 x 0.195 inches
no
A 6-32 X 0.195 inches (multi-pole units only)
yes
2 ISO M3 x 5mm
no
B ISO M3 x 5mm (multi-pole units only)
yes
RECESSED OFF SIDE ROCKER ACTUATOR 19
5 6-32 x 0.195 inches
no
E 6-32 x 0.195 inches (multi-pole units only)
yes
6 ISO M3 x 5mm
no
F ISO M3 x 5mm (multi-pole units only)
yes
PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole
3 6-32 x 0.195 inches
no
C 6-32 x 0.195 inches (multi-pole units only)
yes
4 ISO M3 x 5mm
no
D ISO M3 x 5mm (multi-pole units only)
yes
11 AGENCY APPROVAL
C
UL Recognized & CSA Accepted
E
TUV Certified, UL Recognized & CSA Accepted
I
UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted
www.carlingtech.com
A-Series Flat Rocker UL 489A – Ordering Scheme
A 1 1 – B 0 – 14 – 630 – 2 3 1 – M T
1
Series
2
Actuator
3
Poles
5
Aux/Alarm
Switch
4
Circuit
6
Frequency
& Delay
2 ACTUATOR 1
Two Color Visi-Rocker
1
Indicate OFF, vertical legend
2
Indicate OFF, horizontal legend
Single color
3
Vertical legend
4
Horizontal legend
Push-To-Reset, Visi-Rocker
5
Indicate OFF, vertical legend
6
Indicate OFF, horizontal legend
Push-To-Reset , Single color
7
Vertical legend
8
Horizontal legend
2
Two
3
Three
4 CIRCUIT
B
Series Trip (Current)
5 AUXILIARY/ALARM SWITCH 3,4
0
w/o Aux Switch
1
S.P.D.T., 0.093 Q.C. Term.
2
S.P.D.T., 0.110 Q.C. Term.
3
S.P.D.T., 0.139 Solder Lug
6 FREQUENCY & DELAY
11
DC Ultra Short
12
DC Short
14
DC Medium
16
DC Long
7
8
9
S.P.S.T., 0.110 Q.C.
Term.(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
52
54
56
DC, Short,Hi-Inrush
DC,Medium, Hi-Inrush
DC, Long, Hi-Inrush
Notes:
1
Push-To-Reset actuators have OFF portion of rocker shrouded.
2
Multi-pole breakers have all breakers identical except when specifying Aux. switch
and/or mixed poles, and have one rocker per breaker.
3
Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with standard half
shells. 30-50 amps are supplied with extended boat (B-Style) half shells.
4
On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole.
5
VDE Certification available with single pole breakers only. UL489A Listing available with
one and two pole breakers.
6
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30
amps are only available with Terminal Codes 5, 9 G, H, M and Q.
7
Terminal Code 1 (Push-On) available up to 25 amps with VDE Certification and 30 amps
with UL489A Listing, but is not recommended over 20 amps.
8
Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock
Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and
Flat Washers. These breakers are only TUV or VDE Certified when the washers are
used.
9
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30
amps with VDE Certification and 50 amps with UL489A Listing.
10
Terminal Code Q not available with VDE certification.
11
Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O legend.
12
Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8.
Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator
codes 5 & 6.
13
Recessed “off-side” available with actuator codes 1, 2, 3 & 4. Legends on rocker are
available in ink stamping only.
www.carlingtech.com
8
Terminal
9
Actuator
Color
7 CURRENT RATING (AMPERES)
285
0.850
210
0.100
290
0.900
215
0.150
295
0.950
220
0.200
410
1.000
225
0.250
512
1.250
230
0.300
415
1.500
235
0.350
517
1.750
240
0.400
420
2.000
245
0.450
522
2.250
250
0.500
527
2.750
255
0.550
430
3.000
260
0.600
435
3.500
265
0.650
440
4.000
270
0.700
445
4.500
275
0.750
450
5.000
280
0.800
1 SERIES
A
3 POLES 2
1
One
7
Current Rating
8 TERMINAL 6
17
Push-On 0.250 Tab (Q.C.)
2
Screw 8-32 w/upturned lugs
8
Screw 8-32 (Bus Type)
3
4
Screw 10-32 w/upturned lugs
8
Screw 10-32 (Bus Type)
5
6
Screw 8-32 w/upturned lugs
and 30° bend
7
Screw 8-32 (Bus Type) and
30° bend
8
Screw 10-32 w/upturned lugs
and 30° bend
9
Screw 10-32 (Bus Type) and
30° bend
9 ACTUATOR COLOR & LEGEND
Actuator or
Visi-Color 11
Marking
ON-OFF
Dual11
White
B
1
Black
D
2
Red
G
3
Green
J
4
Blue
L
5
Yellow
N
6
Gray
Q
7
Orange
S
8
10
Mounting/
Barriers
12
11
Max. Appl. Agency
Approval
Rating
613
614
615
616
617
618
620
622
624
625
630
635 5
640 5
645 5
650 5
13.000
14.000
15.000
16.000
17.000
18.000
20.000
22.000
24.000
25.000
30.000
35.000
40.000
45.000
50.000
455
460
465
470
475
480
485
490
495
610
710
611
711
612
712
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
10.500
11.000
11.500
12.000
12.500
B
C
F
Screw M5 w/upturned lugs
Screw M4 w/upturned lugs
Screw M5 w/upturned lugs
and 30° bend
Screw M5 (Bus Type)
and 30° bend
Screw M5 (Bus Type)
M6 Threaded Studs
Printed Circuit Board
Terminals
Push-In Stud
G
H8
M8
P9
Q10
Marking Color:
Single Color
Visi-Rocker
Black
White
White
n/a
White
Red
White
Green
White
Blue
Black
Yellow
Black
Gray
Black
Orange
10 MOUNTING/BARRIERS12
BARRIERS
STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole
FLAT ROCKER ACTUATOR
1 6-32 x 0.195 inches
no
A 6-32 X 0.195 inches (multi-pole units only)
yes
2 ISO M3 x 5mm
no
B ISO M3 x 5mm (multi-pole units only)
yes
13
RECESSED OFF SIDE ROCKER ACTUATOR
5 6-32 x 0.195 inches
no
E 6-32 x 0.195 inches (multi-pole units only)
yes
6 ISO M3 x 5mm
no
F ISO M3 x 5mm (multi-pole units only)
yes
PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole
3 6-32 x 0.195 inches
no
C 6-32 x 0.195 inches (multi-pole units only)
yes
4 ISO M3 x 5mm
no
D ISO M3 x 5mm (multi-pole units only)
yes
11 MAXIMUM APPLICATION RATING
M
80 DC
12 AGENCY APPROVAL
T
UL489A Listed
J
UL489A Listed, TUV Certified
45
A-Series Handle – Circuit & Terminal Diagrams
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.020 [.51] unless otherwise specified.
3
Alarm Switch available with .110 x .020 Q.C. & Solder Lug Terminals Only.
46
www.carlingtech.com
A-Series Handle – Circuit & Terminal Diagrams
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.020 [.51] unless otherwise specified.
3
Alarm Switch available with .110 x .020 QC & solder lug terminals only.
www.carlingtech.com
47
A-Series Handle – Form & Fit Drawings
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ± 0.20 [.51] unless otherwise specified.
3
For agency code P = .150 [3.81].
48
www.carlingtech.com
A-Series Handle – Front Panel Snap-In Mounting Style 5
Notes:
1
All dimensions are in inches [millimeters].
2
Recommended panel thickness: .040 [1.02] to .100 [2.54].
3
Tolerance ±.020 [.51] unless otherwise specified.
www.carlingtech.com
49
A-Series Handle – Front Panel Snap-In Mounting Style 7
Notes:
1
All dimensions are in inches [millimeters].
2
Recommended panel thickness: .040 [1.02] to .100 [2.54].
3
Tolerance ±.020 [.51] unless otherwise specified.
50
www.carlingtech.com
A-Series Sealed Toggle – Form & Fit Drawings
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.020 [.51] unless otherwise specified.
www.carlingtech.com
51
A-Series Rocker – Circuit & Terminal Diagrams
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.020 [.51] unless otherwise specified.
3
Schematic shown represents current trip circuit.
4.
Circuits shown for >30 amps / VDE.
52
www.carlingtech.com
A-Series Rocker – Form & Fit Drawings
Notes:
1
Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal
orientation on indicate OFF is opposite of indicate ON.
2
For pole orientation with horizontal legend, rotate front view clockwise 90°.
3
All dimensions are in inches [millimeters].
4
Tolerance ± 0.20 [.51] unless otherwise specified.
www.carlingtech.com
53
A-Series Rocker Snap-In Bracket – Form & Fit Drawings
Notes:
1
Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal
2
For pole orientation with horizontal legend, rotate front view clockwise 90°. Orientation
on indicate "OFF" is opposite of indicate "ON"
3
Recommended panel thickness: .04 0 [1.02] to .100 [2.54]
4
All dimensions are in Inches [millimeters].
5
Tolerance ±.020 [.51] unless otherwise specified.
54
www.carlingtech.com
A-Series Flat Rocker – Form & Fit Drawings
Notes:
1
All dimensions are in inches [millimeters].
2
For pole orientation with horizontal legend, rotate front view clockwise 90°.
3
Tolerance ± 0.20 [.51] unless otherwise specified.
www.carlingtech.com
55
A-Series PC Terminal Diagrams
Notes:
1
Drawing illustrates A-Series with VDE certification.
2
All dimensions are in inches [millimeters].
3
Tolerance ± 0.20 [.51] unless otherwise specified.
56
www.carlingtech.com