E-Series – General Specifications Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire or a pressure plate connector for stranded wire. Power selector device available, consult factory. The E-Series is UL Listed and CSA Certified for Branch Circuit protection which does not require a fuse backup. It is also UL Recognized and CSA Certified as a Supplementary Protector and as a Manual Motor Controller. 1-6 poles, .1 - 100 amps, up to 600 VAC or 125 VDC, with choice of time delays and actuator colors. Agency Certifications UL Recognized UL Standard 1077 UL Standard 508 UL Standard 1500 UL Listed UL Standard 489 Component Recognition Program as Protectors, Supplementary (Guide QVNU2, File E75596) Component Recognition Program as Manual Motor Controls (Guide NLRV2, File E135367) Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ2, File E75596) Ignition Protection Circuit Breakers, Molded Case (Guide DIVQ, File E129899) CSA Accepted Component Supplementary Protector (Class 3215 30, File 047848 0 000) CSA Standard C22.2 No. 235 CSA Certified Circuit Breaker Molded Case (Class 1432 01, File 093910), CSA Standard C22.2 No. 5.1 - M TUV Certified EN60934 under License No. R72031056 VDE Certified EN60934, VDE 0642 under File No. 10537 Electrical Table A: Lists UL Listed (489) & CSA Certified (C22.2 No. 5) configurations & performance capabilities as a Molded Case Circuit Breaker. 102 www.carlingtech.com E-Series – General Specifications Electrical Table B: Lists UL Recognized & CSA Accepted configurations & performance capabilities as a Component Supplementary Protector. Notes for Table B: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amp rating and not to exceed 225 amps Table C: Lists UL Recognized, CSA Accepted and VDE Certified configurations and performance capabilities as a Component Supplementary Protector. Notes for Table C: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amp rating and not to exceed 225 amps. Table D: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors. www.carlingtech.com 103 E-Series – General Specifications Electrical Maximum Voltage Current Ratings Auxiliary Switch Rating Insulation Resistance Dielectric Strength Resistance, Impedance Mechanical 600VAC 50/60 Hz, 125VDC (See Table A) Standard current coils: 0.100, 0.250, 0.500, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 50.0, 60.0, 70.0 & 100 Amp. SPDT; 10.1A 250VAC, 1.0A 65VDC; 0.5A 80VDC, 0.1A 125VAC (with gold contacts). Minimum of 100 Megohms at 500 VDC. UL, CSA: 2200 V 50/60 Hz for one minute between all electrically isolated terminals. E-Series Circuit Breakers comply with the 8mm spacing and 3750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN 60950 and VDE 0805. Values from Line to Load Terminal based on Series Trip Circuit Breaker. Endurance Trip Free Trip Indication 10,000 ON-OFF operations @ 6 per minute; with rated Current and Voltage. All E-Series Circuit Breakers will trip on overload, even when Handle is forcibly held in the ON position. The operating Handle moves positively to the OFF position when an overload causes the breaker to trip. Physical Number of Poles Mounting Connectors, Box Type Internal Circuit Configuration Weight Standard Colors 1-6 A 3" minimum spacing must be provided between the circuit breaker arc venting area on back connected E-Series circuit breakers and grounded obstructions. ESeries circuit breakers must be mounted on a vertical surface. Front connected E-Series circuit breakers are supplied with box type pressure connectors that accept copper or aluminum conductors as follows: 1/0-14 Copper, 1/0-12 Aluminum. Series and Switch Only, (with or without auxiliary switch). Shunt with current coils. Approximately 252 grams/pole (Approximately 9 ounces/pole) Housing-Black; Actuator - See Ordering Scheme. Environmental Pulse Tolerance Curves 104 Designed and tested in accordance with requirements of specification MIL-PRF- 55629 and MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Vibration Withstands 0.060" excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C www.carlingtech.com E-Series Handle UL Recognized – Ordering Scheme E A 2 – B 0 – 24 – 450 – 1 2 A – C B 1 Series 2 Actuator 3 Poles 6 Frequency & Delay 5 Auxiliary Switch 4 Circuit 7 Current Rating 1 SERIES E 3 4 4 CIRCUIT 2 A3 Switch Only (No Coil) B Series Trip (Current) C Series Trip (Voltage) D Shunt Trip (Current) 5 AUXILIARY SWITCH 4 0 without Auxiliary Switch 2 S.P.D.T. 0.110 Q.C. Terminals 3 S.P.D.T. 0.139 Solder Lug 4 S.P.D.T. 0.110 Q.C. Terminals (Gold Contacts) 6 FREQUENCY & DELAY 033 DC 50/60Hz, Switch Only 105 DC Instantaneous 12 DC Short 14 DC Medium 16 DC Long 5 50/60Hz Instantaneous 20 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 30 DC, 50/60Hz Instantaneous 32 DC, 50/60Hz Short Three Four 5 6 Five Six E F G Shunt Trip (Voltage) Relay Trip (Current) Relay Trip (Voltage) 6 7 S.P.D.T. 0.110 Q.C. Terminals S.P.D.T. 0.110 Q.C. Terminals (Gold Contacts) S.P.D.T. 0.187 Q.C. Terminals S.P.D.T. 0.187 Q.C. Terminals 8 9 34 36 62 64 66 72 74 76 926 946 966 J48 48 AC, 40 AC J65 65 AC, 55 AC K20 120 AC, 65 AC L40 240 AC, 130 AC 10 Mounting/ Barriers 11 Maximum Application Rating 12 Agency Approval Marking Color: Dual 1 2 3 4 5 6 7 8 Black White White White White Black Black Black 10 MOUNTING/BARRIERS BACK CONNECTED (FRONT MOUNTED ONLY) Mounting Inserts A 6-32 B ISO M3 FRONT CONNECTED (BACK MOUNTED ONLY) 14 Back Mounting Foot Type Front Mounting Inserts (Optional Use) C Short 6-32 D Short ISO M3 E Long 6-32 F Long ISO M3 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 35.000 640 40.000 650 50.000 660 60.000 670 70.000 680 80.000 690 90.000 810 100.000 811 110.000 812 120.000 9128 125.000 NOTES 1 VDE approval on 1-5 poles only. Standard multi-pole units identical poles except when specifying auxiliary switch - (see Note 4). For mixed ratings, consult factory. 2 Switch Only & Series Trip construction available w/either front or back connected terminals. Shunt construction available w/back connected terminals, (Terminal Codes 1 & 2) only. Circuit Codes B,C & D are VDE approved. 3 Switch Only construction: 30 amps or less select Current Rating Code 630; 31-70 amps, select Current Rating code 670; 71-100 amps, select Current Rating Code 810; 101-125 amps Select Current Rating Code 912. Switch Only is VDE approved only if tied to a protected pole. 4 Auxiliary Switch available on Switch Only and Series Trip units. On multi-pole units, only one auxiliary switch is normally supplied mounted in the extreme right pole. Back mounted units require special mounting provisions when auxiliary switch is specified. VDE approval on Auxilary Switch Codes 0,2,3 & 4 only. www.carlingtech.com 9 ACTUATOR COLOR & LEGEND13 Actuator Color Marking: Color: I-O ON-OFF White A B Black C D Red F G Green H J Blue K L Yellow M N Gray P Q Orange R S DC, 50/60Hz Medium DC, 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC, Short,Hi-Inrush DC,Medium, Hi-Inrush DC, Long, Hi-Inrush DC, 50/60Hz Short, Hi-Inrush DC, 50/60Hz Medium, Hi-Inrush DC, 50/60Hz Long, Hi-Inrush 7 CURRENT RATING (AMPERES) 7 020 0.020 235 0.350 430 3.000 025 0.025 240 0.400 435 3.500 030 0.030 245 0.450 440 4.000 035 0.035 250 0.500 445 4.500 040 0.040 255 0.550 450 5.000 045 0.045 260 0.600 455 5.500 050 0.050 265 0.650 460 6.000 055 0.055 270 0.700 465 6.500 7.000 060 0.060 275 0.750 470 475 7.500 065 0.065 280 0.800 480 8.000 070 0.070 285 0.850 485 8.500 075 0.075 290 0.900 490 9.000 080 0.080 295 0.950 495 9.500 085 0.085 410 1.000 610 10.000 090 0.090 512 1.250 710 10.500 090 0.095 415 1.500 611 11.000 210 0.100 517 1.750 711 11.500 215 0.150 420 2.000 612 12.000 220 0.200 522 2.250 712 12.500 225 0.250 425 2.500 613 13.000 230 0.300 527 2.750 OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS)5 A06 6 DC, 5 DC A65 65 DC, 55 DC A12 12 DC, 10 DC B25 125 DC, 100 DC A18 18 DC, 15 DC J06 6 AC, 5 AC A24 24 DC, 20 DC J12 12 AC, 10 AC A32 32 DC, 25 DC J18 18 AC, 15 AC A48 48 DC, 40 DC J24 24 AC, 20 AC 9 Actuator Color 8 TERMINAL12 BACK CONNECTED (FRONT MOUNTED ONLY) MAX. RATING 10-32 Stud (All Terminals) 50 A 19 9 2 1/4-20 Stud (All Terminals) 100 A 9 M5 Stud (Line & Load) 50 A A M6 Stud (Line & Load) 100 A B9 FRONT CONNECTED (BACK MOUNTED ONLY) MAX. RATING Box Wire Connector (Line & Load) 100 A 310 11 Box Wire Connector w/ Pressure Plate (Line & Load) 100 A C 4 10-32 Screw (Line & Load) 50 A D M5 Screw (Line & Load) 50 A 5 10-32 “Bus-Type” Screw (Line), 10-32 Screw (Load) 50 A E M5 “Bus-Type” Screw (Line), 10-32 Screw (Load) 50 A 10 10-32 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A 6 11 10-32 “Bus-Type” Screw (Line), Box Wire Connector F w/ Pressure Plate (Load) 100 A 7 1/4-20 Screw (Line & Load) 100 A G M6 Screw (Line & Load) 100 A 8 1/4-20 “Bus-Type” Screw (Line), 1/4-20 Screw (Load) 100 A H M6 “Bus-Type” Screw (Line), M6 Screw (Load) 100 A 10 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A 9 11 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector J w/ Pressure Plate (Load) 100 A 2 ACTUATOR Handle A Handle, one per pole 3 POLES 1 1 One 2 Two 8 Terminal 11 MAXIMUM APPLICATION RATING15 A 65 VDC, 120 A B 125 VDC, 120 A C 120/240 VAC, 100 A D 240 VAC, 100 A 16 277/480 VAC, 100 A E F 277 VAC, 100 A G16 H16 J16 L16 T W16 600 VAC, 100 A 480 VAC, 100 A 415 VAC, 100 A 160 VDC, 100 A 125 VDC/240 VAC, 100 A 125 VDC/415 VAC, 100 A 12 AGENCY APPROVAL B UL 1077 / UL508 Recognized & CSA Accepted D UL 1077 Recognized, CSA Accepted, & VDE Certified 5 6 7 8 9 10 11 12 13 14 15 16 Voltage Trip Coils are not rated for continuous duty. Available only with Frequency & Delay Codes 10 & 20. Series Trip construction with a voltage coil s VDE approved only if tied to a protected pole. Frequency & Delay Codes 92,94 & 96 are not VDE Certified. Current Coil Ratings 0.100 - 100 ams are VDE Certified. 125 A rating (Code 912) available as a Switch Only (Circuit Code A), rated 125 VDC (Code B). An Anti-Flash Over Barrier is supplied between poles on multi-pole units with 10-32 (Terminal Code 1). 1/4-20 (Code 2), M5 (Code A), and M6 (Code B) terminals per UL requirement. Box Wire Connector will accept #14 through 0 AWG. copper wire or #12 through 0 AWG. aluminum wire. Box Wire Connector with Pressure Plate for stranded wire, consult factory for details. Terminal Codes A,B,D,E,G & H are not VDE Certified. VDE approvals require Dual (I-O, ON-OFF) or I-O markings on all handles. Back Mounted breakers can also be front mounted by utilizing the proper front panel mounting inserts normally supplied. However, terminal connections must be made prior to mounting. Application ratings B,D,J,T & W are available with VDE. 415, 480 & 600 VAC ratings require 3 or 4 pole break 3Ø and 2 pole break 1Ø. 105 E-Series Handle UL Listed – Ordering Scheme E A 2 – B 0 – 24 450 – 1 2 A – C C 1 Series 2 Actuator 3 Poles 4 Circuit 5 Auxiliary Switch 6 Frequency & Delay 1 SERIES E 2 ACTUATOR Handle A Handle, one per pole 3 POLES 1 1 One 2 Two 3 4 4 CIRCUIT 2 B Series Trip (Current) 5 AUXILIARY SWITCH 4 0 without Auxiliary Switch 2 S.P.D.T. 0.110 Q.C. Terminals 3 S.P.D.T. 0.139 Solder Lug 4 S.P.D.T. 0.110 Q.C. Terminals (Gold Contacts) 6 FREQUENCY & DELAY 105 DC Instantaneous 12 DC Short 14 DC Medium 16 DC Long 5 50/60Hz Instantaneous 20 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 32 DC, 50/60Hz Short 34 DC, 50/60Hz Medium 36 DC, 50/60Hz Long Three Four 5 6 C3 Series Trip (Voltage) 6 7 S.P.D.T. 0.110 Q.C. Terminals S.P.D.T. 0.110 Q.C. Terminals (Gold Contacts) S.P.D.T. 0.187 Q.C. Terminals S.P.D.T. 0.187 Q.C. Terminals 8 9 62 64 66 72 74 76 926 946 966 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush DC, 50/60Hz Short, Hi-Inrush DC, 50/60Hz Medium, Hi-Inrush DC, 50/60Hz Long, Hi-Inrush 7 CURRENT RATING (AMPERES)7 020 0.020 235 0.350 430 3.000 025 0.025 240 0.400 435 3.500 030 0.030 245 0.450 440 4.000 035 0.035 250 0.500 445 4.500 040 0.040 255 0.550 450 5.000 045 0.045 260 0.600 455 5.500 050 0.050 265 0.650 460 6.000 055 0.055 270 0.700 465 6.500 7.000 060 0.060 275 0.750 470 475 7.500 065 0.065 280 0.800 480 8.000 070 0.070 285 0.850 485 8.500 075 0.075 290 0.900 490 9.000 080 0.080 295 0.950 495 9.500 085 0.085 410 1.000 610 10.000 090 0.090 512 1.250 710 10.500 090 0.095 415 1.500 611 11.000 210 0.100 517 1.750 711 11.500 215 0.150 420 2.000 612 12.000 220 0.200 522 2.250 712 12.500 225 0.250 425 2.500 613 13.000 230 0.300 527 2.750 OR VOLTAGE COIL (MIN. TRIP RATING, VOLTS)5 A06 6 DC, 5 DC A65 65 DC, 55 DC A12 12 DC, 10 DC B25 125 DC, 100 DC A18 18 DC, 15 DC J06 6 AC, 5 AC A24 24 DC, 20 DC J12 12 AC, 10 AC A32 32 DC, 25 DC J18 18 AC, 15 AC A48 48 DC, 40 DC J24 24 AC, 20 AC 106 Five Six 614 14.000 615 15.000 616 16.000 617 17.000 618 18.000 620 20.000 622 22.000 624 24.000 625 25.000 630 30.000 635 35.000 640 40.000 650 50.000 660 60.000 670 70.000 680 80.000 690 90.000 810 100.000 912 125.000 J48 48 AC, 40 AC J65 65 AC, 55 AC K20 120 AC, 65 AC L40 240 AC, 130 AC 7 Current Rating 8 Terminal 9 Actuator Color 10 Mounting/ Barriers 11 Maximum Application Rating 12 Agency Approval 8 TERMINAL7 BACK CONNECTED (FRONT MOUNTED ONLY) MAX. RATING 10-32 Stud (All Terminals) 50 A 18 1/4-20 Stud (All Terminals) 100 A 28 FRONT CONNECTED (BACK MOUNTED ONLY) MAX. RATING Box Wire Connector (Line & Load) 100 A 39 100 A C10 Box Wire Connector w/ Pressure Plate (Line & Load) 4 10-32 Screw (Line & Load) 50 A 5 10-32 “Bus-Type” Screw (Line), 10-32 Screw (Load) 50 A 10-32 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A 69 F10 10-32 “Bus-Type” Screw (Line), Box Wire Connector w/ Pressure Plate (Load) 100 A 7 1/4-20 Screw (Line & Load) 100 A 8 1/4-20 “Bus-Type” Screw (Line), 1/4-20 Screw (Load) 100 A 99 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector (Load) 100 A 1/4-20 “Bus-Type” Screw (Line), Box Wire Connector J10 w/ Pressure Plate (Load) 100 A 9 ACTUATOR COLOR & LEGEND12 Actuator Color : Marking: Color: ON-OFF Dual White B 1 Black D 2 Red G 3 Green J 4 Blue L 5 Yellow N 6 Gray Q 7 Orange S 8 Marking Color: Black White White White White Black Black Black 10 MOUNTING/BARRIERS BACK CONNECTED (FRONT MOUNTED ONLY) Mounting Inserts A 6-32 B ISO M3 FRONT CONNECTED (BACK MOUNTED ONLY) 11 Back Mounting Foot Type Front Mounting Inserts (Optional Use) C Short 6-32 D Short ISO M3 E Long 6-32 F Long ISO M3 11 MAXIMUM APPLICATION RATING B 125 VDC, 100A C13 120/240 VAC, 100A D 240 VAC, 100A 12 AGENCY APPROVAL C UL 489 Listed & CSA Certified F UL 489 Listed, CSA Certified, & VDE Certified NOTES 1 Standard multi-pole units identical poles except when specifying auxiliary switch - (see Note 4). For mixed ratings, consult factory. VDE Certification on 1-5 poles only. 2 Series Trip construction available w/either front or back connected terminals. 3 Series Trip construction with a voltage coil is not available as a single pole unit and must be tied to a protected pole. 4 On multi-pole units, only one auxiliary switch is normally supplied mounted in the extreme right pole per Figure A. Back mounted units require special mounting provisions when auxiliary switch is specified. VDE Certification on auxilary switch codes 0, 2, 3 & 4 only. 5 Voltage Trip Coils are not rated for continuous duty. Available only with Frequency & Delay Codes 10 & 20. 6 Frequency & Delay Codes 92, 94 & 96 are not VDE Certified. 7 Current Ratings under 0.100 amps are not VDE Certified . 8 An Anti-Flash Over Barrier is supplied between poles on multi-pole units with 10-32 Stud (Terminal Code 1) or 1/4-20 Stud (Code 2) terminals per UL requirement. 9 Box Wire Connector will accept #14 through 0 AWG. copper wire or #12 through 0 AWG. aluminum wire. 10 Box Wire Connector with Pressure Plate for stranded wire, consult factory for details. 11 Back Mounted breakers can also be front mounted by utilizing the proper front panel mounting inserts normally supplied. However, terminal connections must be made prior to mounting. 12 VDE Certification requires dual (I-O , ON-OFF) markings on all handles. 13 Not available with VDE Certification. www.carlingtech.com E-Series Handle & Rocker – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 0-50 amps: 10-32 & M5 Studs .625±.062/15.88±1.574 long. 51-120 amps: 1/4-20 & M6 Studs .750±.062/19.05±1.574 long. www.carlingtech.com 107 E-Series Handle (Back Connected) – Form & Fit Drawings Notes: 1 1/4 -20 stud terminal in Series Trip circuit configuration shown. 2 A 3” min spacing must be provided between the circuit breaker arc venting area of back connected E-Series circuit breaker and grounded obstructions. 3 All dimensions are in inches [millimeters]. 4 Tolerance ±.020 [.51] unless otherwise specified. 5 Circuit breakers must be mounted on vertical surface. 108 www.carlingtech.com E-Series Handle (Front Connected) – Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Box wire connector terminal in Series Trip circuit configuration shown. 4 Circuit breakers must be mounted on vertical surface. www.carlingtech.com 109