Telecom/Datacom Circuit Protection CATALOG Transforming Customer Needs into Customer Solutions Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! By working closely with a customer’s product team and understanding the requirements of the specific application, Carling’s product experts can tailor switching and circuit protection solutions to meet any customer’s needs—cost effectively. Since the company was founded in 1920, there are few products that Carling Technologies hasn’t turned “ON” and fewer industries that haven’t turned to Carling for solutions. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling now ranks among the world’s largest, privately owned manufacturers of hydraulic magnetic circuit breakers, thermal circuit breakers, electrical switches, electronic switches, miniature switches, power distribution centers, digital switching systems and electronic controls. Globally, there are over 2,000 employees working for Carling, providing solutions to customers’ application needs with innovation, value, and world-class service for both standard and custom products. Carling’s breadth and depth of standard product offerings gives customers literally millions of configuration choices to meet the demands of its Strategic Markets: Marine M ilitary Renewable Energy Telecom/Datacom Transportation Additional markets served by Carling products include: Audio Visual, Commercial Food Equipment, Commercial HVAC, Floor Care, Generators, Industrial Control, Kitchen & Small Appliances, Security Systems, Test & Measurement equipment, among others. If the standard product does not meet the application requirements, the engineering team at Carling has the expertise to customize solutions faster and more creatively thanks in measure to over ninety years of experience as an innovative company that manufactures a diverse range of products. The Carling Sales, Service and Engineering teams work closely with the customer’s engineering team to advance a custom project from initial concept to final design and product release, respecting both quality and cost through out the process. With extensive field knowledge and resources available, Carling Technologies can ensure that the products created for the customer are of superior quality from the start, thus avoiding costly secondary operations or modifications. Carling’s commitment to excellence consistently delivers “Quality by Design,” the company mission. Carling has an extensive network of Sales Representatives and Distributors to assist with Carling products, or contact a Carling Technologies’ Technical Sales Representative to design innovative, cost-effective, quality engineered solutions that exceed the tough demands of today’s applications. ii www.carlingtech.com Contents Product Selector Guide Innovative, HighPerformance Circuit Protection For Datacom/Telecom Equipment Carling Technologies offers a full line of innovative, high-performance and reliable circuit breakers that meet all current datacom/telecom industry performance and design requirements insuring continued services and maximum circuit protection. These circuit breakers are ideally suited for page 2 Product Specifications & Ordering Information M-Series 4 H-Series 23 L-Series 35 A-Series 39 B-Series 58 C-Series75 CX-Series 92 F-Series 100 Time Delay Values M-Series111 A, B, C, L, CX-Series 112 F-Series115 Custom Power Distribution Units 116 the rigors and confined spaces found in today’s telecom/datacom power distribution units and rack systems. In other words, Carling circuit breakers protect against unnecessary power outages while providing design features that exceed today’s expectations. Global Footprint Carling Technologies World Headquarters Plainville, CT, USA Maretron Phoenix, AZ, USA Carling Technologies European Headquarters Exeter, UK Carling Technologies Carling Technologies Brownsville, TX, USA Kowloon, Hong Kong Carling Technologies Carling Technologies Matehuala, Mexico Zhongshan, China Carling Technologies Jupiter, FL, USA www.carlingtech.com 1 Product Selector Guide M-SERIES H-SERIES L-SERIES A-SERIES NUMBER OF POLES 1-2 1-3 1-3 1-6 (handle); 1-3 (rocker & metal toggle) ACTUATOR STYLE Solid Color Angled Rocker Two Color Visi-Rocker Illuminated Angled Rocker Illuminated Flat Rocker Solid Color Paddle Solid Color Baton Solid Color Push-to-Reset Pushbutton Solid Color Push-Pull Pushbutton Handle, Rocker, Curved & Flat Rocker, with or without guard Sealed Metal Toggle, Handle, Rocker, Paddle AVAILABLE DELAYS Instant, Short, Medium AC/DC, Hi-Inrush Instantaneous, Ultra-short, Short, Medium & Long, AC, DC AC: Ultrashort, Short, Medium, Long, Short-High Inrush, Medium-High Inrush, Long-High Inrush Instantaneous, Ultra-short, Short, Medium & Long, AC, DC, AC/DC High Inrush - Short, Medium & Long AC and DC MAXIMUM CURRENT & VOLTAGE RATINGS 0.02-15FLA, 32VDC, 125VAC, 1 pole 15.1-25GPA, 32VDC, 125VAC, 1-pole 0.02-15FLA, 65VDC, 250VAC, 2-pole 15.1-25GPA, 65VDC, 250VAC, 2-pole 0.02-12FLA, 250VAC, 1-pole 0.02-7.5GPA, 50VDC, 1-pole 0.02-30GPA, 65VDC, 80VDC, 1 pole 31-50GPA, 80VDC, Parallel 1-32A@65VDC, 80VDC, 250VAC .2-30A, 120/240-240VAC 0.02 -30A@277VAC, 80VDC MAXIMUM INTERRUPTING CAPACITY 1,000A @ 65VDC, 2-pole 1,000A @ 32VDC, 1-pole 1,000A @ 250VAC, 2-pole 1,000A @ 125VAC, 1-pole 600A @ 80VDC 3000A@65VDC 1000A@80VDC 1500A@250VAC AUXILIARY SWITCH RATING 7A @ 250VAC 0.1A @ 125VAC (gold contacts) 7A (Res.) @ 28VDC 4A (Ind.) @ 28VDC 0.25A @ 80VDC 1.0A-65VDC/0.5A-80VDC, 0.1A-125VAC (with gold contacts) N/A 10.1A@125VAC 0.1A@125VAC (gold contacts) 0.5A@65VDC 0.1A@80VDC AVAILABLE CIRCUITS Series and Switch Only Parallel Pole Series, Switch Only, Relay Trip / V Coil Series Trip Series, Shunt, Relay, Switch Only, Series w/ Remote Shutdown, Relay & Shunt Trip Dual Coil TERMINAL OPTIONS .250” QC Tabs 8-32 Screw w/ Upturned Lugs 8-32, 10-32 Screw (Bus Type) Push in Stud Terminals .250” QC Tabs, 8-32 & 10-32 Screw (& metric), PCB 10-32, 8-32, M5 & M4 Screw .250” QC Tabs, 8-32 & 10-32 Screw (& metric), PCB Threaded inserts Threaded Insert: #6-32 UNC-2B, or M3X0.5-6H B ISO (2 per Pole) Threaded inserts: Front Panel Snap-In UL Recognized, CSA Accepted, TUV Certified & CCC Certified UL 489, CUL, TUV (EN60934-2) UL, CSA, VDE, TUV (rocker), UL1500, UL489A MOUNTING METHOD Snap-in Front Panel Threaded Bushing AGENCY APPROVALS 2 UL recognized, CSA, VDE, TUV, UL489A Listed 31.0-50A@125/250VAC, 65VDC 5000 Amps 7500A @ 65 VDC, UL only 3000A @ 125/250VAC, UL only 5000A @ 277VAC, w/ fuse backup www.carlingtech.com Product Selector Guide B-SERIES C-SERIES F-SERIES CX-SERIES 1-6 1-6 (handle); 1-3 (rocker & metal toggle) 1- 2, + Auxiliary Switch Pole 1-3 Handle, Rocker Sealed Metal Toggle, Handle, Rocker Handle, 1 per pole Handle Instantaneous, Ultra-short, Short, Medium & Long, AC, DC, AC/DC High Inrush - Short, Medium & Long AC and DC Instantaneous, Ultrashort, Short, Medium & Long, AC, DC, AC/DC High Inrush - Short, Medium & Long AC and DC DC: Instantaneous, Ultrashort, Short, Medium & Long Short, Medium & Long DC, AC 0.02 -30A@277VAC, 80VDC UL Listed 0.02-250A@80VDC 0.1-100@125VDC 0.02-70A@120VAC 0.02-20A@240VAC ULRecognized 0.02-30A@480WYE /277VAC2-pole, 1Ø, 3-pole, 3Ø 0.02-50A@277VAC 0.02-100A@250VAC,80VDC 0.02-100A@120/240VAC, 65VDC UL Recognized .2 -125A, 600VDC UL Listed .2-15A, 250/500VDC UL489 Listed: 50-250A@125VDC 100-250A@120/240VAC 100-250A@277VAC 100-250A@208Y/120 3Ø UL489A Listed 250-700A@125VDC 7500A@80 VDC, UL only 3000A@125/250VAC, UL only 5000A@277VAC, w/ fuse backup UL Listed 50000A@80VDC, single pole only 10,000A@120VAC, 5000A@125VDC, 240VAC ULRecognized 7500A@80VDC 3000A@125/250VAC, UL only 5000A@250VAC - listed construction 5000A@480WYE/277V AC w/fuse backup Up to 10,000 UL Listed and UL recognized 50000A@125VDC 10000A, 120/240, 277, 208Y/120 10.1A@125VAC 0.1A@125VAC (gold contacts) 0.5A@65VDC 0.1A@80VDC 10.1A@250VAC 0.1A@125VAC (gold contacts) 0.5A@65VDC 20A, 80VDC (GO circuit) 10.1A@250VAC 0.5A@65VDC 0.1A@80VDC Series, Shunt, Relay, Switch Only, Series w/ Remote Shutdown, Relay & Shunt Trip Dual Coil, Mid-Trip with Alarm Switch Series, Shunt,Relay, Switch Only, Series w/ Remote Shutdown, Relay & Shunt Trip Dual Coil,Mid-Trip with Alarm Switch Series Trip Series & Switch Only with or without Metering Shunt AVAILABLE CIRCUITS .250” QC Tabs, 8-32 & 10-32 Screw (& metric), PCB 10-32 Stud, 1/4-20 Stud, 0-32 Screw w/ saddle clamp,Clip Terminal, 1/4 & 7/16 Push-In 10-32 or M5 Screw Terminals 1/4-20 or M6 Threaded Stud 3/8-16 Stud, 3/8-16 Screw & Box Wire Connector TERMINAL OPTIONS Threaded inserts: Front Panel Snap-In Threaded inserts Threaded insert: #6-32 UNC-2B, or M3X0.5-6H B ISO (2 per pole) Rear or Front Panel UL, CSA, VDE, TUV (rocker), UL1500, UL489, UL489A UL, CSA, VDE, TUV, UL1500, UL489, UL489A UL489, UL1077, TUV (EN60934-2) CUL,TUV, UL489, UL489A 31.0-50A@125/250VAC, 65VDC www.carlingtech.com NUMBER OF POLES ACTUATOR STYLE AVAILABLE DELAYS MAXIMUM CURRENT & VOLTAGE RATINGS MAXIMUM INTERRUPTING CAPACITY AUXILIARY SWITCH RATING MOUNTING METHOD AGENCY APPROVALS 3 M-Series Circuit Breaker M-Series Circuit Breaker The M-Series is a low cost, miniature hydraulic/magnetic circuit breakers ideally designed for demanding applications requiring space saving features, aesthetics and snap-in front panel mounting. Its newest design features a compact, space saving, vertically mounted parallel pole configuration, which is UL489A listed up to 50 amps and is well suited for telecommunication equipment fitting in one rack unit. Furthermore, it features two uniquely designed terminals that provide the highest level of balanced circuit protection. In addition, these circuit breakers feature various styling options allowing for design flexibility. They are available in choices of rocker actuator styles and colors, including paddle and baton style handle actuators, push-to-reset and push-pull pushbutton actuators, Visi-Rocker two color actuators as well as non-illuminated or illuminated rocker versions with LED or neon bulbs. The exclusive Rockerguard bezel helps prevent inadvertent actuation and wiping contact design insures long-term reliability. The M-Series circuit breakers are available in 1 & 2 poles or parallel poles, 0.02 to 50 amps, up to 250VAC or 80VDC with choices of time delays, terminals, panel hardware, actuator styles, colors, and imprinting. Features: Parallel pole configuration well suited for One Rack Unit MIL-PRF-55629 and MIL STD 202 compliant MIL-PRF-39019F ingress protection Sealed toggle actuator Compact design 4 www.carlingtech.com M-Series Circuit Breaker - General Specifications Electrical Mechanical Maximum Voltage 125/250 VAC 50/60 Hz, 80 VDC (See Rating Tables.) Current Ratings Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00 thru 15.0 in 1 amp increments, 18.0, 20.0, 25.0, 30.0. Other ratings available - see Ordering Scheme. Auxiliary Switch Rating SPDT; 7A 250VAC, 7A (Res) 28VDC, 4A (Ind.) 28VDC, 0.25A 80VDC (Res) (silver contacts), 0.1A 125VAC (gold contacts). Insulation Resistance Minimum of 100 Megohms at 500 VDC. Dielectric Strength UL, CSA 1500V, 50/60 Hz for one minute between all electrically isolated terminals. M-Series Circuit Breakers comply with the 8mm spacing and 3750 V 50/60Hz dielectric requirements from hazardous voltage to operator accessible surfaces, per Publications IEC 380, 435, 950, EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker. Endurance 10,000 ON-OFF operations @ 6 per minute with rated Current and Voltage. Trip Free All M-Series Circuit Breakers will trip on overload, even when actuator is forcibly held in the ON position. Trip Indication The actuator moves positively to the OFF position when an overload causes the circuit breaker to trip. RESISTANCE PER POLE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) CURRENT (AMPS) TOLERANCE (%) 0.10 - 20.0 20.1 - 50.0 ±25 ±35 Pulse Tolerance Curves Physical Number of Poles Internal Circuit Configs. Weight Standard Colors 1 or 2 Series with or without Auxiliary Switch. Switch Only with or without Auxiliary Switch. Approximately 30 grams/pole (Approximately 1.07 ounces/pole) See Ordering Scheme.a Environmental Designed in accordance with requirements of specification MIL PRF-55629 & MIL-STD-202G as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Cond. I. Instantaneous curves tested at 80% of rated current. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous curves tested at 80% of rated current. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80 98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C Chemical Resistance Only the outside surfaces of the case and the handles may be cleaned with detergents or alcohol. Organic (hydrocarbon based) solvents are not recommended because they attack plastics. Caution should be taken when solvents are used to clean and remove flux from terminals. Lubricants should not be introduced into the handle/ bushing openings *Manufacturer reserves the right to change product specification without prior notice. www.carlingtech.com 5 M-Series Circuit Breaker - General Specifications Electrical Tables Table A: Lists UL Recognized and CSA Accepted configurations & performance capabilities as a Component Supplementary Protector. Table A Notes: 1 Polarity Sensitive 2 Available only with Special Catalog Number. Consult Factory. 3 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 30 Amps maximum 4 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 60 Amps maximum Table B: Lists UL Recognized,CSA Accepted and TUV and VDE Certified configurations and performance capabilities as a Component Supplementary Protector. Table B Notes: 1 Polarity Sensitive 2 Available only with Special Catalog Number. Consult Factory. 3 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 30 Amps maximum 4 TUV only, not VDE 5 Requires backup protection with a thermal magnetic circuit breaker rated 32 amps and having a Type C trip characteristic per EN60898/DIN VDE 0641 (C32A) for ratings greater than 15amps, and a thermal magnetic circuit breaker rated 16 amps and having a Type C trip characteristic per EN60898/DIN VDE 0641 (C16A) for ratings 15 amps and less 6 www.carlingtech.com M-Series Circuit Breaker - General Specifications Electrical Tables Table C: Lists UL489A Listed and TUV Certified configurations and performance capabilities for use in Communications Equipment. M-SERIES TABLE C: UL489A Listed Table C Notes: 1 Available only with Special Caralog Number Table D: Lists UL489A Listed configurations and performance capabilities for use in Communications Equipment. M-SERIES TABLE D: Parallel Pole Construction UL489A Listed (COMMUNICATIONS EQUIPMENT - POLARITY SENSITIVE) CIRCUIT CONFIGURATION SERIES INTERRUPTING CAPACITY (AMPS) MAX. RATING FREQUENCY CURRENT RATING GENERAL PURPOSE AMPS 80 DC 31-50 2 600 65 1 DC 31-50 2 1000 VOLTAGE POLES BREAKING WITHOUT BACKUP FUSE UL489A Table D Notes: withSpecial Special Catalog Number. Consult Factory. 11. Available Available only only with Caralog Number Agency Certifications UL Recognized UL Standard 1077 UL Listed UL Standard 489A Component Recognition Program as Protectors, Supplementary (Guide CCN/QVNU2, File E75596) Communications Equipment (Guide CCN/DITT, File E189195) www.carlingtech.com CSA Accepted Component Supplementary Protector (Class 3215 30, File 047848 0 000) CSA Standard C22.2 No. 235 VDE Certified EN60934, VDE 0642 under File 10537 TUV Certified EN60934, under License No. R9671109 7 M-Series Parallel Pole Rocker - Ordering Scheme M E 2 1 Series 2 Actuator 3 Poles P 4 Circuit D2 5 Frequency & Delay 650 5 6 Current Rating 7 Terminal A 1 2 9 8 Illumination Actuator Color & Legend 10 Legend B 11 Bezel Color T 12 Agency Approval 7 TERMINAL 1 SERIES M A 5 Push in Stud 10-32 Screw (Bus Type) 2 ACTUATOR Single Color Rocker Two Color Visi-Rocker Single Color Translucent Rocker A Angled D Indicate ON F Angled Flat E Indicate OFF G Flat B 8 ILLUMINATION Non-Illuminated A Non-Illuminated 9 ACTUATOR COLOR & LEGEND Actuator Visi1 Legend 1 White 2Black 3Red 4Green 5Blue 6 Yellow 7 Gray 8 Orange 3 POLES 2Two 4 CIRCUIT/AUXILIARY SWITCH2 P Series Trip Current (Parallel Pole) with Auxiliary Switch, Silver Contacts Q Series Trip Current (Parallel Pole) with Auxiliary Switch, Gold Contacts R Series Trip Current (Parallel Pole) 5 FREQUENCY & TIME DELAY D2 D4 DC Short DC Medium 6 CURRENT RATING (AMPERES) CODE 631 635 640 645 650 AMPERES 31.000 35.000 40.000 45.000 50.000 Black White White White White Black Black Black 10 LEGEND 2 3 6 7 .110 x 0.20 Q.C .110 x 0.20 Q.C ON - OFF Vertical ON - OFF Horizontal Dual Vertical Dual Horizontal 11 BEZEL COLOR A B G 1 2 7 White without Rockerguard Black without Rockerguard Gray without Rockerguard White with Rockerguard Black with Rockerguard Gray with Rockerguard 12 AGENCY APPROVAL T UL 489A Listed Notes: 1 Reminder of Rocker same color as Visi 2 Aux Switch only available with screw terminals Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com 8 www.carlingtech.com M-Series Parallel Pole - Handle / Push Button - Ordering Scheme M M 2 1 Series 2 Actuator 3 Poles P 4 Circuit D2 5 Frequency & Delay 650 5 6 Current Rating 7 Terminal M Paddle TPush-Pull 3 POLES 2Two 4 CIRCUIT/AUXILIARY SWITCH1 .110 x 0.20 Q.C DC Short DC Medium 6 CURRENT RATING (AMPERES) 11 BUSHING COLOR 12 AGENCY APPROVAL B AMPERES 31.000 35.000 40.000 45.000 50.000 T Push in Stud 10-32 Screw (Bus Type) Handle 1 White 2 Black 3 Red 4 Green 5 Blue 6 Yellow 7 Gray 8 Orange Black UL 489A Listed Notes: 1 Aux Switch only available with screw terminals 7 TERMINAL 8 ACTUATOR COLOR & LEGEND T 12 Agency Approval Handle Actuator Legend Plate ON - OFF Vertical B C ON - OFF Horizontal Push-Pull Actuator Legend Plate Rated Amps Horizontal 2 3 Rated Amps Line Side Down 4 Rated Amps Line Side Up 631 635 640 645 650 A 5 B 11 Brushing Color 10 LEGEND PLATE / BUTTON MARKING .110 x 0.20 Q.C 5 FREQUENCY & TIME DELAY CODE 10 Legend Plate/ Marking Handle A No outer Panel Hardware B Knurled Nut, Bright Nickel C Knurled Nut, Bright Nickel w/Locking Ring D Knurled Nut, Black E Knurled Nut, Black w/Locking Ring F Panel Dress, Bright Nickel G Panel Dress, Bright Nickel w/Locking Ring H Panel Dress, Black J Panel Dress, Black w/Locking Ring Push Button 1 No outer Panel Hardware 2 Knurled Nut, Bright Nickel 2 ACTUATOR D2 D4 9 Front Panel Hardware 9 FRONT PANEL HARDWARE 1 SERIES M P Series Trip Current (Parallel Pole) with Auxiliary Switch, Silver Contacts Q Series Trip Current (Parallel Pole) with Auxiliary Switch, Gold Contacts R Series Trip Current (Parallel Pole) 1 B B 8 Actuator Color Push Button A White BBlack CRed DGreen EBlue FYellow GGray HOrange Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com www.carlingtech.com 9 M-Series Parallel Pole - Form & Fit Drawings PARALLEL POLE TERMINAL OPTIONS PUSH-IN STUD 10-32 SCREW W/ BUS BAR .652 [16.56] .912 [23.16] 1.000 [25.4] .838 [21.29] .154 [3.91] .393 [9.97] 1.125 [28.58] 1.000 [25.4] .100 [2.54] .750 [19.05] ROCKER ACTUATOR DETAIL INDICATE "ON" (VISI-ON) .370 [9.40] MAX. ±.020 1.394 [35.41] [±.508] ±.020 1.530 [38.86] [±.508] 1.304 [33.12] LINE OFF .970 [24.64] 1.375 [34.93] 1.560 [39.62] 1.125 [28.58] ON LOAD .400 [10.16] .625 [15.88] .100 [2.54] ROCKERGUARD CONFIGURATION INDICATE "OFF" (VISI-OFF) & SINGLE COLOR ±.020 ±.020 ±.508 ±.508 .305 [7.75] .675 [17.14] LOAD ON LOAD ON OFF LINE ±.020 ±.508 1.050 [26.67] OFF LINE 5 PANEL CUT - OUT DETAIL (ROCKER) DOUBLE POLE PANEL THICKNESS DIM. A ±.005 ±.13 1.139 [33.76] DIM. A +.005 +.13 -.000 -.00 .062 [1.57] 1.385 [35.18] .093 [2.36] 1.420 [36.07] .125 [3.18] 1.460 [37.08] Notes: 1 ALL DIMENSIONS ARE IN INCHES [MILLIMETERS]. 2 TOLERANCE ±.010 [.25] UNLESS OTHERWISE SPECIFIED. 3 DIMENSIONS APPLY TO BOTH ROCKER STYLES. 4 I-O, ON-OFF OR DUAL LEGENDS AVAILABLE FOR VERTICAL OR HORIZONTAL MOUNTING. 5 NOTICE THAT CIRCUIT BREAKER LINE AND LOAD TERMINAL ORIENTATION ON INDICATE “OFF” IS OPPOSITE THAT OF INDICATE “ON”. 10 NO 1 2 3 4 www.carlingtech.com M-Series Parallel Pole - Form & Fit Drawings PADDLE ACTUATOR STYLE PUSH-PULL ACTUATOR STYLE 1.484 1.395 1/2-32 THD. 3/8" 8-32 THD. 12° ON OFF FLAT 12° FLAT ±.030 +.010 -.000 +.25 -.000 +.25 -.000 .500 DIA [Ø12.70] +.010 -.000 ±.002 ±.05 +.010 -.000 ±.005 [±.13] +.25 -.000 .125 DIA [Ø3.18] WITH LOCKING RING WITHOUT LOCKING RING .625 [15.87] DIA .494 [12.55] +.25 -.00 .544[13.82] .534 [13.56] SNAP-IN BUSHING .156 [3.56] .078 [1.98] .435 [11.05] DIA PANEL DRESS NUT 0N 1.025 [26.04] O F F O N BUTTON MARKING ORIENTATION 0FF LEGEND CODE: .098 [2.49] HEX NUT .632 DIA [Ø16.05] .340 [8.64] ±.76 PANEL HARDWARE PUSH-PULL, PUSH TO RESET ±.002 [±.050] .222 [5.64] LEGEND PLATES .025 [.64] ±.030 .375 [9.53] DIA .162 [4.11] .355 [9.02] .400 [10.16] MOUNTING DETAILS MOUNTING DETAILS +.010 -.000 ±.76 ±.76 .280 [7.11] ON .500 [12.70] .500 DIA [Ø12.70] ±.030 ±.030 .500 [12.70] OFF (SHOWN) .470 [11.94] ±.76 ACTUATOR COLOR VISIBLE IN OFF POSITION ONLY B LINE C LINE PANEL HARDWARE .625 [15.88] .680 DIA [Ø17.27] .125 [3.18] .180 [4.57] 20 20 20 3 4 LINE MARKING CODE: 2 NOTES: .110QC AUXILIARY SWITCH1. TERMINALS ALL DIMENSIONS PANEL DRESS NUT HEX NUT .680 DIA [Ø17.27] .125 [3.18] .105 [2.67] .031 [.79] .683 DIA [Ø17.27] KNURLED NUT .342 [8.69] ARE IN 2. TOLERANCE ±.010 [.25] U 3. DIMENSIONS APPLY TO 4. I-O, ON-OFF OR DUAL LE VERTICAL OR HORIZONT 5. NOTICE THAT CIRCUIT B ORIENTATION ON INDICA INDICATE "ON". LOCKING RING Notes: 1 ALL DIMENSIONS ARE IN INCHES [MILLIMETERS]. 2 TOLERANCE ±.010 [.25] UNLESS OTHERWISE SPECIFIED. 3 DIMENSIONS APPLY TO BOTH ROCKER STYLES. 4 I-O, ON-OFF OR DUAL LEGENDS AVAILABLE FOR VERTICAL OR HORIZONTAL MOUNTING. 5 NOTICE THAT CIRCUIT BREAKER LINE AND LOAD TERMINAL ORIENTATION ON INDICATE “OFF” IS OPPOSITE THAT OF INDICATE “ON”. www.carlingtech.com TITLE DR BY 11 M ME 5/10/12 M-Series Handle/Pushbutton UL489A/UL Recognized – Ordering Scheme M M 1 1 Series 2 Actuator B 14 4 Circuit 3 Poles 620 5 Frequency & Delay 1 6 Current Rating 7 Terminal 1 B B 8 Actuator Color 7 TERMINAL4 1 SERIES M 1 2 3 2 ACTUATOR1 Handle M Paddle NBaton Push Button TPush-Pull U Push To Reset Push Button w/ Snap-In Mounting VPush-Pull W Push To Reset Gloss Handle Push-Button 1A 2B 3C 4D 5E 6F 8H 9 FRONT PANEL HARDWARE6 1 Handle No outer Panel Hardware A Knurled Nut Bright nickel B Bright nickel with locking ring C Black D Black with locking ring E Panel Dress Nut Bright nickel F Bright nickel with locking ring G Black H Black with locking ring J One 4 CIRCUIT without Auxiliary Switch B Series Trip (Current) with Auxiliary Switch, Silver Contacts Terminal Type: M Switch Only, (Current) Aux Switch .110 QC x .020 QC 2 S Series Trip (Current) .060 Dia, Round Solder Turret T2,3 Series Trip (Current) .058 Dia, Round Q.C. U3,12 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C. with Auxiliary Switch, Gold Contacts 42,3 Series Trip (Current) .058 Dia, Round Q.C. 53,12 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C. 9 Series Trip (Current) .110 QC x .020 QC 5 FREQUENCY & DELAY 12 14 DC Short DC Medium 72 74 020 025 030 035 040 045 050 055 060 065 070 075 080 085 090 090 210 215 220 AMPERES 0.020 0.025 0.030 0.035 0.040 0.045 0.050 0.055 0.060 0.065 0.070 0.075 0.080 0.085 0.090 0.095 0.100 0.150 0.200 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 410 512 415 517 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 1.250 1.500 1.750 710 611 711 612 712 613 614 615 616 617 618 620 622 624 625 630 10.500 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 Push-In Stud Printed Circuit Board Actuator Color White Black Red Green Blue Yellow Orange Push-Button 1 2 Handle Actuator Legend Plate (Actuator Styles M & N) No Legend Plate A B ON - OFF Vertical C ON - OFF Horizontal D I - O Vertical E I - O Horizontal Push-Pull Actuator Button Cap (Actuator Styles T & V) No Marking 18 2 Rated Amps Horizontal 3 Rated Amps Line Side Down 4 Rated Amps Line Side Up Push-to-Reset Actuator Button (Actuator Styles U& W) 8 No Marking 1 DC, Short,Hi-Inrush DC,Medium, Hi-Inrush 420 2.000 522 2.250 425 2.500 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 J 12 Agency Approval 10 LEGEND PLATE / BUTTON MARKING 6 CURRENT RATING (AMPERES) CODE 11 Bushing Color A10 P11 Push-On 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (Bus Type) 8 ACTUATOR COLOR & LEGEND5 3 POLES B 10 9 Front Panel Legend Hardware Plate 11 BUSHING COLOR7 B Black 12 AGENCY APPROVAL9 J M N T UL489A Listed, TUV Certified UL Recognized, CSA Accepted UL Recognized, TUV Certified UL489A Listed Notes: 1 One actuator is located in the center of each multi-pole breaker. Actuator codes V & W limited to single pole breakers only. 2 One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip and Switch Only circuits. Not available with Back Connected Screw or Push-in Stud terminals. 3 Mates with AMP .058” diameter pin receptacles including 60983-1 (gold plated) and 60983-3 (tin plated). 4 Screw terminals or Push-in Stud recommended above 20 amps. 5 Actuator color is only visible in the OFF position on Push-Pull actuators. 6 All units have one hex nut installed on bushing for use behind the panel. 7 Other colors available. Consult factory. 8 Not available with UL489A Listed breakers. 9 TUV certified to 25 amps. UL Recognized, CSA Accepted and UL Listed to 30 amps. 10 Terminal code A available with circuit codes A & B only. 11 Printed circuit board available with UL recognized approval only. 12 Auxiliary switch (flat Q.C.) available with UL recognized approvals only. Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com 12 www.carlingtech.com M-Series Handle – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 13 M-Series Handle – PC Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 14 www.carlingtech.com M-Series Handle - Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 15 M-Series Pushbutton – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 16 www.carlingtech.com M-Series Pushbutton – Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ± 0.20 [.51] unless otherwise specified. 3 Available with Push-Pull or Push-to-Reset Actuators www.carlingtech.com 17 M-Series Push-Pull – PC Terminal Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 18 www.carlingtech.com M-Series Rocker UL489A/UL Recognized – Ordering Scheme M A 1 1 Series 2 Actuator B 14 4 Circuit 3 Poles 5 Frequency & Delay 620 6 Current Rating 1 A 1 6 9 8 Illumination Actuator Color 7 Terminal 7 TERMINAL9 1 SERIES M 1 2 3 2 ACTUATOR1 Non-Illuminated single color A Angled B Flat Two Color Visi-Rocker D Indicate ON E Indicate OFF llluminated single color F Angled G Flat Push-On 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (Bus Type) 8 ILLUMINATION Non-illuminated Neon4 without resistor, 120VAC/250VAC LED7, 8 without resistor with resistor, 4-8 VDC with resistor, 9-16 VDC 2 10 Legend A11 P12 A Neon B Red D E F J 11 Bezel Color 12 Agency Approval Push-In Stud Printed Circuit Board Green Glow8 C Green G H J Amber K L M 9 ACTUATOR & LEGEND COLOR 3 POLES 1 One 4 CIRCUIT2 without Auxiliary Switch B Series Trip (Current) with Auxiliary Switch, Silver Contacts Terminal Type: M Switch Only, (Current) Aux Switch .110 QC x .020 QC S Series Trip (Current) .060 Dia, Round Solder Turret 3 T Series Trip (Current) .058 Dia, Round Q.C. U3,13 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C. with Auxiliary Switch, Gold Contacts 43 Series Trip (Current) .058 Dia, Round Q.C. 53,13 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C. 9 Series Trip (Current) .110 QC x .020 QC 5 FREQUENCY & DELAY 10 12 DC Instantaneous DC Short 14 72 74 DC Medium DC, Short,Hi-Inrush DC,Medium, Hi-Inrush 6 CURRENT RATING (AMPERES) 8 CODE 020 025 030 035 040 045 050 055 060 065 070 075 080 085 090 090 210 215 220 AMPERES 0.020 0.025 0.030 0.035 0.040 0.045 0.050 0.055 0.060 0.065 0.070 0.075 0.080 0.085 0.090 0.095 0.100 0.150 0.200 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 410 512 415 517 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 1.250 1.500 1.750 420 2.000 522 2.250 425 2.500 527 2.750 430 3.000 435 3.500 440 4.000 445 4.500 450 5.000 455 5.500 460 6.000 465 6.500 470 7.000 475 7.500 480 8.000 485 8.500 490 9.000 495 9.500 610 10.000 710 611 711 612 712 613 614 615 616 617 618 620 622 624 625 630 10.500 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 Notes: 1 One actuator is located in the center of each multi-pole breaker. 2 One Auxiliary Switch is supplied per breaker. Auxiliary Switch option limited to Series Trip & Switch Only circuits, and is not available in single pole illuminated breakers, or with Back Connected Screw or Push-in Stud terminals. 3 Mates with AMP .058” diameter pin receptacles: 60983-1 (gold plated) & 60983-1 (tin plated). 4 For neon bulb applications at 120VAC @ 47K, 1/4 WATT and for 250VAC applications @ 150K, 1/4 WATT, external resistors must be supplied by customer. 5 For LED (DC or rectified AC) applications, LED is mounted in the center of the rocker actuator with electrical characteristics as follows: 100 millicandela at 20mA; Maximum power dissipation = 75mW at 25°C; Maximum forward current = 25mA; Typical forward voltage = 2.1V at 20mA; Typical reverse current = 100uA at 3V. Customer supplies the proper external resistor limiting current to these values. 6 On Visi-Rocker breakers, Visi portion of rocker cannot be the same color as the bezel. 7 Rocker color for LED’s and green neon lamp must be clear, smoke gray, white translucent or match color of LED or neon lamp. 8 Other colors available. Consult factory. 9 TUV Certified to 25 amps. UL Recognized, CSA Accepted and UL489A Listed to 30 amps. Screw Terminals recommended above 20 amps. 10 UL489A Listed must have ON-OFF or Dual legends. TUV Certified approvals must have I - O or Dual legends. 11 Terminal code A available with circuit codes A & B only. 12 Printed circuit board available with UL recognized approval only. 13 Auxiliary switch (flat Q.C.) available with UL recognized approvals only. Solid Color Actuator Legend 1 White Black 2 Black White 3 Red White 4 Green White 5 Blue White 6 Yellow Black 7 Gray Black 8 Orange Black Visi-Rocker6 Visi & Legend (remainder of rocker same color as bezel) 1 White 2 Black 3 Red 4 Green 5 Blue 6 Yellow 7 Gray 8 Orange Illuminated7 Actuator Legend A Clear White B Red Transparent White C Green Transparent White D Amber Transparent White E Smoke Gray Transparent White F White Translucent Black 10 LEGEND10 1 2 3 4 5 6 7 No Legend (Single Color or Illuminated Rocker Options Only) ON - OFF Vertical ON - OFF Horizontal I - O Vertical I - O Horizontal Dual Vertical Dual Horizontal 11 BEZEL COLOR / STYLE8 Color White Black Gray without Rockerguard with Rockerguard A1 B2 G7 12 AGENCY APPROVAL9 J M N T UL489A Listed & TUV Certified UL Recognized & CSA Accepted TUV Certified, UL Recognized & CSA Accepted UL489A Listed Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com www.carlingtech.com 19 M-Series Rocker – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuit. 20 www.carlingtech.com M-Series Rocker – Form & Fit Drawings Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate OFF is opposite of indicate ON. 2 I-O, ON-OFF or dual legends available for vertical or horizontal mounting. For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 All dimensions are in inches [millimeters]. 4 Tolerance ± 0.20 [.51] unless otherwise specified. www.carlingtech.com 21 M-Series Rocker – Supplementary Diagrams 22 www.carlingtech.com H-Series Circuit Breaker H-Series Circuit Breaker The H-Series hydraulic/magnetic circuit breaker provides dependable circuit protection in a low cost, compact package. By meeting the IEC spacing requirements, the H-Series is the ideal choice for international market applications. It also features a “trip-free” mechanism, which will open the contacts when a fault condition occurs, even if the handle is held in the ON position. Although a low cost option, the H-Series was designed for maximum performance and reliable equipment protection meeting Carling’s stringent quality standards. Key Features & Benefits: Choice of actuator styles UL1077, CCC, CSA, C22.2 and EN60934 approvals Compact size Temperature stable operation -40oc to 80oc Choice of terminals, including PCB Single or multi-pole configurations www.carlingtech.com 23 H-Series – General Specifications Electrical Tables Table A: Lists UL Recognized, CSA Accepted and TUV Certified configurations and performance capabilities as a Component Supplementary Protector. H SERIES - COMPONENT SUPPLEMENTARY PROTECTOR CIRCUIT VOLTAGE CONFIGURATION CURRENT SHORT CIRCUIT CAPACITY (AMPS) MAX RATING FREQ. PHASE 65 DC -- 65 DC -- 80 DC -- SERIES 80 1 DC -- 250 50/60 1 250 50/60 1 250 50/60 3 FULL LOAD 1 - 32 MINIMUM POLES UL WITHOUT BACKUP FUSE CSA WITHOUT BACKUP FUSE TUV WITHOUT BACKUP FUSE 1 3000 3000 1500(PC1) 1 --- 500 --- --- TC1, OL1, U3 1 1000 800 1000(PC1) TC1, OL1, U1 TC1, OL1, U1 1 - 32 1 - 25 26 - 32 1 - 32 1 - 32 1 - 32 APPLICATION CODES UL CSA TC1, OL1, U1 TC1, OL1, U1 1 1000 1000 1000(PC1) TC1, OL1, U3 TC1, OL1, U3 1 1500 1500 1000(PC1) TC1, OL1, U1 TC1, OL1, U1 2 1500 1500 1000(PC1) TC1, OL1, U3 TC1, OL1, U3 3 1500 1500 1000(PC1) TC1, OL0, U3 TC1, OL0, U3 1 - Polarity Sensitive Electrical Maximum Voltage Current Rating Auxiliary Switch Rating Typical Protector Resistance 250VAC 50/60Hz 80 VDC Standard current coils: 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 32.0 SPDT: 10.1A-250VAC, 1.0A-65VDC/0.5A-80VDC, 0.1A-125VAC (with gold contacts) Mechanical Endurance Physical Number of Poles Weight Internal Circuit Config. 10,000 ON-OFF operations @ 6 per minute; with rated current & voltage 1-3 Approx. 48 grams/pole (1.7 oz) Series and Switch Only (with or without auxiliary switch) Agency Approvals DCR and Impedance values are based on measurements by the voltmeter ammeter method. Rated current is applied for one hour and at a voltage not less than 20 volts. Ambient temperature: 25 ℃; Tolerance: Below 10 amps +/- 25%; Above 10 amps +/-35% Impedance Chart Current rating in amperes Series DC-Ohms 50/60Hz-Ohms 1 0.85 0.87 2.5 0.13 0.15 5 0.035 0.036 7.5 0.018 0.019 10 0.01 0.011 15 0.006 0.0061 20 0.005 0.0051 25 0.003 0.0035 30 0.0025 0.0026 UL Recognized under the Component Recognition Program as Protectors, Supplementary (Guide QVNU2 File E75596) UL standard 1077 CCC certified, Certificate No. 2010010307447291 CSA Accepted Circuit Breaker, CSA standard C22.2 No. 235 TUV certified to EN60934, Certificate No. R50204086 *Manufacturer reserves the right to change product specification without prior notice. 24 www.carlingtech.com H-Series – Dimensional Specifications: in. [mm] – Handle Actuator LINE LOAD www.carlingtech.com 25 H-Series – Dimensional Specifications: in. [mm] – Curved Rocker Actuator #6-32[M3] THREAD *0.138[3.50] DEEP #6-32[M3] THREAD *0.138[3.50] 2 PLCS PER POLE DEEP 2 PLCS PER POLE 1-POLE (HJ1) 1.382 [35.10] 1.382 [35.11] 1.130 [28.70] 1.130 [28.70] 1.414 [35.90] 1.414 [35.90] 0.357 [9.08] 0.650 [16.51] MAX 0.650 [16.51] MAX LINE 0.118 [3.00] 1.726 [43.83] 1.726 [43.83] 1.382 [35.10] 0.126 [3.20] 0.126 [3.20] 0.346 [8.80] 0.118 0.346 [3.00] [8.80] 0.357 [9.08] 1.732 [44.00] 1.654 [42.00] 1.654 [42.00] LOAD SCREW TYPE TEMINALS IN SERIES TRIP CIRCUIT CONFIGURATION SHOWN. FOR OTHERS CONFIGURATIONS, SEE CIRCUIT AND TERMINAL DIAGRAMS. 2.354 1.732 [59.78] [44.00] TAB(Q.C.)TYPE 2.354 [59.78] 2.354 [59.78] TAB(Q.C.)TYPE SCREW TYPE 2.354 [59.78] SCREW TYPE 0.161 [4.08] 1.382 [35.11] 0.161 [4.08] 0.413 [10.50] 0.413 [10.50] 1.260 [32.01] 1.260 [32.01] 2-POLE (HJ2) 0.630 [16.00] LINE 1.130 [28.70] 1.130 [28.70] OPTIONAL "ROCKER GUARD" OPTIONAL "ROCKER GUARD" 0.630 [16.00] 1.280 [32.51] MAX LOAD 1.280 [32.51] MAX 1.197 [30.40] 1.197 [30.40] LINE C 1.693 [43.01] 1.693 [43.01] 0.778 [19.75] LOAD 0.778 [19.75] 2-Ø0.156 [Ø3.96] 2-Ø0.156 [Ø3.96] 0.118 [2.99] 0.118 [2.99] 1.382 [35.10] 1.382 [35.10] LINE ON NC 1.929 [49.00] MAX 1.929 [49.00] MAX 0.630 [16.00] TYP 0.630 [16.00] TYP ON NC C 3-POLE (HJ3) 1.146 [29.12] 1.146 [29.12] 0.640 [16.27] LOAD 0.640 [16.27] POLE POLE POLE 1 2 3 MULTI-POLE IDENTIFICATION SCHEME AS VIEWED FROM TERMINAL END OF BREAKER. PANEL CUTOUT DETAIL TOLERANCE +.005[+.12] UNLESS OTHERWISE SPECIFIED NOTES: 1. ALL DIMENSIONS ARE IN INCHES [mm] 2. TOLERANCE +.020 [.51] UNLESS OTHERWISE SPECIFIED. 26 www.carlingtech.com H-Series – Dimensional Specifications: in. [mm] – Flat Rocker Actuator PUSH-TO-RESET ACTUATOR #6-32[M3] THREAD *0.138[3.50] DEEP 2 PLCS PER POLE 1-POLE (H31) 0.126 [3.20] 0.126 [3.20] 0.126 [3.20] 1.382 [35.10] 1.382 [35.10] 1.382 [35.10] 1.382 [35.10] 0.650 [16.51] MAX 0.650 [16.51] MAX 0.650 [16.51] MAX 0.650 [16.51] MAX 0.126 [3.20] 0.118 [3.00] 1.726 1.130 [43.83] [28.70] 1.726 1.130 [43.83] [28.70] 1.726 1.130 [43.83] [28.70] 1.726 1.130 0.359 [9.12] [43.83] [28.70] 0.357 [9.06] 0.359 [9.12] 0.357 0.359 [9.06] [9.12] 0.357 [9.06] 0.359 [9.12] 0.357 [9.06] 0.118 [3.00] 0.118 [3.00] 1.732 [44.00] 0.126 [3.20] 0.126 [3.20] 0.126 [3.20] 0.126 [3.20] 1.382 [35.10] 1.382 [35.10] 1.382 [35.10] 1.382 [35.10] 0.650 [16.51] MAX 0.650 [16.51] MAX 1.382 [35.11] 0.650 [16.51] MAX 1.382 [35.11] 0.650 [16.51] 1.382 [35.11]MAX 1.382 [35.11] 2-POLE (H72) 1.726 1.130 [43.83] [28.70] 1.726 1.130 [43.83] [28.70] 1.726 1.130 [43.83] [28.70] 1.726 1.130 [9.12] [43.83]0.359 [28.70] 0.118 [3.00] 0.118 [3.00] 1.654 [42.00] 1.654 [42.00] 1.654 [42.00] 1.654 [42.00] 1.414 [35.90] 1.414 [35.90] 1.414 [35.90] 1.414 [35.90] 2.353 1.732[59.76] [44.00] TAB(Q.C.)TYPE 1.732[59.76] [44.00] 2.353 2.353 [59.76] TAB(Q.C.)TYPE 2.353 1.732[59.76] [44.00] SCREW TYPE TAB(Q.C.)TYPE 2.353 [59.76] 2.353 [59.76] SCREW TYPE 2.353 [59.76] TAB(Q.C.)TYPE SCREW TYPE 2.353 [59.76] SCREW TYPE 0.118 [3.00] 2-POLE (H71) LINE 0.118 [3.00] LOAD SCREW TYPE TEMINALS IN SERIES TRIP CIRCUIT CONFIGURATION SHOWN. FOR OTHERS CONFIGURATIONS, SEE CIRCUIT AND TERMINAL DIAGRAMS. LINE 0.118 [3.00] LOAD 0.359 [9.12] 0.161 [4.08]0.359 [9.12] 0.161 [4.08]0.359 [9.12] 0.161 [4.08] LINE 0.161 [4.08] 1.260 [32.01] 1.260 [32.01] 1.260 [32.01] 1.260 0.630 [16.00] [32.01] 1.280 [32.51] MAX 0.630 [16.00] 1.130 [28.70] 1.130 [28.70] 1.130 [28.70] 1.130 [28.70] 1.280 [32.51] MAX 0.630 [16.00] 1.280 [32.51] MAX 0.630 [16.00] 1.280 [32.51] MAX 3-POLE (H73) 1.929 [49.00] MAX 1.929 [49.00] MAX 1.929 [49.00] MAX 1.929 [49.00] MAX 0.630 [16.00] TYP 0.630 [16.00] TYP 0.630 [16.00] TYP 0.630 [16.00] TYP LOAD 1.197 [30.40] 1.197 [30.40] 1.197 [30.40] 1.197 1.693[30.40] [43.01] 1.693 [43.01] 1.693 [43.01] 1.693 [43.01] 0.778 [19.75] 0.778 [19.75] 0.778 [19.75] 2-Ø0.156 [Ø3.96] 0.778 [19.75] 2-Ø0.156 [Ø3.96] 2-Ø0.156 [Ø3.96] 2-Ø0.156 [Ø3.96] 1.382 [35.10] 1.382 [35.10] 1.382 [35.10] 1.382 [35.10] LINE LOAD 0.118 [2.99] 0.118 [2.99] 0.118 [2.99] 0.118 [2.99] 1.146 [29.12] 1.146 [29.12] 1.146 [29.12] 1.146 [29.12] 0.640 [16.27] 0.640 [16.27] 0.640 [16.27] 0.640 [16.27] MULTI-POLE IDENTIFICATION SCHEME AS VIEWED FROM TERMINAL END OF BREAKER. PANEL CUTOUT DETAIL TOLERANCE +.005[+.12] UNLESS OTHERWISE SPECIFIED NOTES: 1. ALL DIMENSIONS ARE IN INCHES [mm] 2. TOLERANCE +.020 [.51] UNLESS OTHERWISE SPECIFIED. www.carlingtech.com 27 H-Series – Dimensional Specifications: in. [mm] – PC Terminals PRINTED CIRCUIT BOARD MOUNTING TERMINAL CODE R PRINTED CIRCUIT BOARD MOUNTING TERMINAL CODE L PRINTED CIRCUIT BOARD MOUNTING TERMINAL CODE S & T NOTES: 1. ALL DIMENSIONS ARE IN INCHES [mm] 2. TOLERANCE +.020 [.51] UNLESS OTHERWISE SPECIFIED. 28 www.carlingtech.com H-Series – Dimensional Specifications: in. [mm] – PC Terminals P.C. FOOT PRINT FOR TERMINAL CODE R P.C. FOOT PRINT FOR TERMINAL CODE L P.C. FOOT PRINT FOR TERMINAL CODE S & T NOTES: 1. ALL DIMENSIONS ARE IN INCHES [mm] 2. TOLERANCE +.020 [.51] UNLESS OTHERWISE SPECIFIED. www.carlingtech.com 29 H-Series – Dimensional Specifications: in. [mm] – Circuit & Terminal HANDLE POSITION VS. AUX SWITCH MODE STANDARD C/B CIRCUIT BREAKER MODE HANDLE POSITION OFF AUX. SWITCH MODE 30° OFF NC NO C NC NO C NC NO C ON 30° ON 30° ELECTRICAL TRIP OFF O 0.381 [9.69] 0.047 [1.20] TERMINAL DIMENSIONAL DETAIL & RATING 0.264 [6.70] Ø0.067 [Ø1.71] TAB (Q.C.) 0.264 [6.70] 0.264 [6.70] 0.250 [6.35] 0.559 [14.19] 0.354 [9.00] 0.354 [9.00] UPTURN LUG 0.287 [7.29] BUS 0.197 [5.00] 0.197 [5.00] P.C. TERMINAL P.C. TERMINAL THREAD SIZE #6-32 & M3 MOUNTING HARDWARE #8-32 & M4 THREAD TERMINAL SCREW LINE 1.693 [43.00] LOAD MAIN AUX. SWITCH* SEE TABLE B DEPTH BEHIND PANEL TAB (Q.C.) SCREW TYPE 1.996 [50.70] 1.996 [50.70] .110 TAB (Q.C.) 2.467 [62.67] SOLDER TYPE 2.252 [57.19] * AVAILABLE ON SERIES TRIP AND SWITCH ONLY CIRCUITS. WHEN CALLED FOR ON MULTI-POLE UNITS, ONLY ONE AUX. SWITCH IS NORMALLY SUPPLIED, AS SHOWN IN MULTI-POLE IDENTIFICATION SCHEME. 1.854 [47.10] LINE 1.413 [35.90] 30 TORQUE 7-9 IN-LBS [0.8-1.0 NM] 12-15 IN-LBS [1.4-1.7 NM] TABLE B TERMINAL DESCRIPTION 1.732 [44.00] REF P.C. TERMINAL STRAIGHT (LONG) TABLE A TIGHTENING TORQUE SPECIFICATIONS 1.012 [25.70] 1.508 [38.30] 0.315 [8.00] STRAIGHT (SHORT) 1.197 [30.40] LOAD 0.047 [1.20] 0.197 [5.00] 0.315 [8.00] 0.047 [1.20] 90 FACING LEFT 90 FACING RIGHT BARRIER FOR UL-RECOGNIZED MULTI-POLE BREAKERS 0.806 [20.48] 1.413 [35.90] 0.031 [0.80] 1. ALL DIMENSIONS ARE IN INCHES [mm] 2. TOLERANCE ±.020 [.51] UNLESS OTHERWISE SPECIFIED. 0.120 [3.05] www.carlingtech.com H-Series – Dimensional Specifications: in. [mm] – Circuit & Terminal B,C B,C G www.carlingtech.com 31 H-Series Handle Actuator – Ordering Scheme H A 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 24 5 Aux/Alarm Switch 6 Frequency & Delay 450 7 Current Rating 2 ACTUATOR1 B Handle, one per pole 3 POLE2 1 2 One 5 AUXILIARY/ALARM SWITCH 0 13 23 3 C4 G4 Switch Only (no coil) Series Trip (current) w/o Aux Switch 0.110 Q.C. term 0.110 Solder Lug 33 43 6 FREQUENCY & DELAY 30 31 32 34 36 424 444 464 524 544 564 03 104 11 12 14 16 204 21 22 24 26 DC 50/60Hz, Switch Only DC Instantaneous DC Ultra Short DC Short DC Medium DC Long 50/60Hz Instantaneous 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium 50/60Hz Long 1 2 3 A B Handle, one per unit Two 4 CIRCUIT A B AMPERES 410 1.000 440 512 1.250 445 415 1.500 450 517 1.750 455 420 2.000 460 522 2.250 465 425 2.500 470 527 2.750 475 430 3.000 480 435 3.500 485 VOLTAGE RATING CODE A06 A12 A18 A24 A32 A48 RATING 6DC 12DC 18DC 24DC 32DC 48DC TRIP VOLTS 5DC 10DC 15DC 20DC 25DC 40DC 490 495 610 710 611 711 612 712 613 614 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 Series Trip (voltage) Relay Trip (voltage) 0.110 Q.C. term w/ gold contacts 0.110 PC term 10 MOUNTING/BARRIERS MOUNTING STYLE Threaded Insert 1 6-32 x 0.195 inches A 6-32 x 0.195 inches 2 ISO M3 x 5mm B ISO M3 x 5mm 3 6-32 x 0.195 inches C 6-32 x 0.195 inches 4 ISO M3 x 5mm D ISO M3 x 5mm DC, 50/60Hz, Instantaneous DC, 50/60Hz,Ultra Short DC, 50/60Hz, Short DC, 50/60Hz, Medium DC, 50/60Hz, Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush A65 J06 J12 J18 J24 J48 65DC 6AC 12AC 18AC 24AC 48AC 615 616 617 618 620 622 624 625 630 632 9.000 9.500 10.000 10.500 11.000 11.500 12.000 12.500 13.000 14.000 55DC 5AC 10AC 15AC 20AC 40AC J65 K20 L40 B10 B20 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 32.000 65AC 120AC 240AC 110DC 120DC 55AC 65AC 130AC 59DC 65DC Push ON 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (bus type) Screw M4 w/upturned lugs Screw M4 (bus type) 9 ACTUATOR COLOR & LEGEND Actuator Color I-O White A Black C Red F Green H Blue K Yellow M Gray P Orange R Three D C 10 Mounting Bezel/Barrier L R S T 11 Rating Printed Circuitboard Terminals Dual 1 2 3 4 5 6 7 8 Legend Color Black White White White White Black Black Black BARRIERS BEZEL no yes no yes no yes no yes domed domed domed domed flat flat flat flat 80DC 6 12 Agency Approval 90 Facing Left 90 Facing Right Straight Straight, Long ON-OFF B D G J L N Q S 11 MAX. APPLICATION RATING A 65DC D 250AC M 4 80VDC/250VAC7 12 AGENCY APPROVAL A Without approvals C UL Recognized, CSA Accepted, CCC Certified E UL Recognized, CSA Accepted, TUV Certified 5 UL Recognized, CSA Accepted, TUV Certified, CCC Certified 7 CURRENT RATING (AMPERES) 5 CODE 9 Actuator Color & Legend 8 TERMINAL 1 SERIES H A 1 B 1 8 Terminal Notes: 1 Actuator Option A: handle tie pin, spacer & retainers provided unassembled on multipole units. Actuator Option B: Handle location as viewed from front of panel: 2 pole: left pole; 3 pole: center pole 2 Standard multipole units have all poles identical, except when specifying auxiliary switch 3 Auxiliary switch available on Series Trip and Switch Only circuits to 32A. On multipole units, only one aux. switch is normally supplied, mounted in extreme right pole. 4 Separate Pole Type Voltage Coils not rated for continuous duty. Available only with delay code 10 & 20. Only Available w/ Agency code C. 5 For other current ratings, consult factory. 6 26-32A Polarity sensitive, only available as 1 pole unit. 7 Voltage code 4 available to 25A max. Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com 32 www.carlingtech.com H-Series Curved Rocker Actuator – Ordering Scheme H J 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 10 5 Aux/Alarm Switch 6 Frequency & Delay 1 SERIES (VISI ROCKER) H K Vertical - Indicate OFF 3 POLE2 1 2 One 5 AUXILIARY/ALARM SWITCH 0 13 23 3 C4 G4 Switch Only (no coil) Series Trip (current) 1 2 3 A B Vertical - Indicate ON Two 4 CIRCUIT A B Series Trip (voltage) Relay Trip (voltage) 33 43 6 FREQUENCY & DELAY 30 31 32 34 36 424 444 464 524 544 564 DC, 50/60Hz, Instantaneous DC, 50/60Hz,Ultra Short DC, 50/60Hz, Short DC, 50/60Hz, Medium DC, 50/60Hz, Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush 611 711 612 712 613 614 615 616 617 618 619 620 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 19.000 20.000 DC 50/60Hz, Switch Only DC Instantaneous DC Ultra Short DC Short DC Medium DC Long 50/60Hz Instantaneous 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium 50/60Hz Long 0.110 Q.C. term w/ gold contacts 0.110 PC term 7 CURRENT RATING (AMPERES) 5 CODE AMPERES 410 1.000 450 5.000 512 1.250 455 5.500 415 1.500 460 6.000 517 1.750 465 6.500 420 2.000 470 7.000 522 2.250 475 7.500 425 2.500 480 8.000 527 2.750 485 8.500 430 3.000 490 9.000 435 3.500 495 9.500 440 4.000 610 10.000 445 4.500 710 10.500 VOLTAGE RATING CODE A06 A12 A18 A24 A32 A48 RATING 6DC 12DC 18DC 24DC 32DC 48DC TRIP VOLTS 5DC 10DC 15DC 20DC 25DC 40DC 9 Actuator Color & Legend A65 J06 J12 J18 J24 J48 65DC 6AC 12AC 18AC 24AC 48AC 55DC 5AC 10AC 15AC 20AC 40AC 621 622 623 624 625 626 627 628 629 630 632 J65 K20 L40 B10 B20 21.000 22.000 23.000 24.000 25.000 26.000 27.000 28.000 29.000 30.000 32.000 65AC 120AC 240AC 110DC 120DC Push ON 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (bus type) Screw M4 w/upturned lugs Screw M4 (bus type) 10 Mounting Bezel/Barrier L R S T 9 ACTUATOR COLOR & LEGEND Actuator Color I-O White A Red F Green H Blue K Yellow M Gray P Orange R Three w/o Aux Switch 0.110 Q.C. term 0.110 Solder Lug 033 10 11 12 14 16 20 21 22 24 26 1 B 1 8 Terminal 8 TERMINAL 2 ACTUATOR1 J 450 7 Current Rating 55AC 65AC 130AC 59DC 65DC 10 MOUNTING/BARRIERS6 MOUNTING STYLE Threaded Insert 1 6-32 x 0.195 inches A 6-32 x 0.195 inches 2 ISO M3 x 5mm B ISO M3 x 5mm 3 6-32 x 0.195 inches C 6-32 x 0.195 inches 4 ISO M3 x 5mm D ISO M3 x 5mm 5 6-32 x 0.195 inches E 6-32 x 0.195 inches 6 ISO M3 x 5mm F ISO M3 x 5mm 7 6-32 x 0.195 inches G 6-32 x 0.195 inches 8 ISO M3 x 5mm H ISO M3 x 5mm 9 6-32 x 0.195 inches J 6-32 x 0.195 inches P ISO M3 x 5mm K ISO M3 x 5mm Q 6-32 x 0.195 inches L 6-32 x 0.195 inches U ISO M3 x 5mm M ISO M3 x 5mm ON-OFF B G J L N Q S BARRIERS no yes no yes no yes no yes no yes no yes no yes no yes no yes no yes no yes no yes 11 MAX. APPLICATION RATING A 65DC D 250AC M 80DC 7 D C 11 Rating 12 Agency Approval Printed Circuitboard Terminals 90 Facing Left 90 Facing Right Straight Straight, Long Dual 2 3 4 5 6 7 8 HALF ROCKER GUARD no no no no yes yes yes yes no no no no yes yes yes yes no no no no yes yes yes yes 4 BRACKET COLOR Black Black Black Black Black Black Black Black White White White White White White White White Gray Gray Gray Gray Gray Gray Gray Gray FIG.B FIG. C 80VDC/250VAC8 12 AGENCY APPROVAL A Without approvals C UL Recognized, CSA Accepted E UL Recognized, CSA Accepted, TUV Certified 5 UL Recognized, CSA Accepted, TUV Certified, CCC Certified Notes: 1 Half guard construction have OFF protection for actuator 2 Standard multipole units have all poles identical, except when specifying auxiliary switch 3 Auxiliary switch available on Series Trip and Switch Only circuits to 32A. On multipole units, only one aux. switch is normally supplied, mounted in extreme right pole. 4 Separate Pole Type Voltage Coils not rated for continuous duty. Available only with delay code 10 & 20. Only Available w/ Agency code C. 5 For other current ratings, consult factory. 6 On Visi-Rocker,Visi portion of rocker cannot be the same color as the bezel. Remainder of rocker same color as bezel. 7 26-32A Polarity sensitive, only available as 1 pole unit. 8 Voltage code 4 available to 25A max. Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com www.carlingtech.com 33 H-Series Flat Rocker Actuator – Ordering Scheme H 3 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 10 5 Aux/Alarm Switch 6 Frequency & Delay 450 7 Current Rating 2 ACTUATOR1 7 Push–to–Reset, Single Color Vertical 8 Push–to–Reset, Single Color Horizontal Single Color Vertical Single Color Horizontal 3 POLE2 1 2 One C4 G4 Switch Only (no coil) Series Trip (current) 5 AUXILIARY/ALARM SWITCH 0 13 23 3 Two 4 CIRCUIT A B Three Series Trip (voltage) Relay Trip (voltage) 33 43 0.110 Q.C. term w/ gold contacts 0.110 PC term 6 FREQUENCY & DELAY 30 31 32 34 36 424 444 464 524 544 564 DC, 50/60Hz, Instantaneous DC, 50/60Hz,Ultra Short DC, 50/60Hz, Short DC, 50/60Hz, Medium DC, 50/60Hz, Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush DC 50/60Hz, Switch Only DC Instantaneous DC Ultra Short DC Short DC Medium DC Long 50/60Hz Instantaneous 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium 50/60Hz Long 7 CURRENT RATING (AMPERES) 5 CODE AMPERES 410 1.000 450 5.000 512 1.250 455 5.500 415 1.500 460 6.000 517 1.750 465 6.500 420 2.000 470 7.000 522 2.250 475 7.500 425 2.500 480 8.000 527 2.750 485 8.500 430 3.000 490 9.000 435 3.500 495 9.500 440 4.000 610 10.000 445 4.500 710 10.500 VOLTAGE RATING CODE A06 A12 A18 A24 A32 A48 RATING 6DC 12DC 18DC 24DC 32DC 48DC TRIP VOLTS 5DC 10DC 15DC 20DC 25DC 40DC A65 J06 J12 J18 J24 J48 611 711 612 712 613 614 615 616 617 618 619 620 65DC 6AC 12AC 18AC 24AC 48AC 621 622 623 624 625 626 627 628 629 630 632 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 19.000 20.000 55DC 5AC 10AC 15AC 20AC 40AC J65 K20 L40 B10 B20 X01 21.000 22.000 23.000 24.000 25.000 26.000 27.000 28.000 29.000 30.000 32.000 65AC 120AC 240AC 110DC 120DC 65AC 1 2 3 A B Push ON 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (bus type) Screw M4 w/upturned lugs Screw M4 (bus type) 10 Mounting Bezel/Barrier L R S T 9 ACTUATOR COLOR & LEGEND Actuator Color I-O White A Black C Red F Green H Blue K Yellow M Gray P Orange R w/o Aux Switch 0.110 Q.C. term 0.110 Solder Lug 033 10 11 12 14 16 20 21 22 24 26 9 Actuator Color & Legend 8 TERMINAL 1 SERIES H 3 4 1 B 1 8 Terminal 55AC 65AC 130AC 59DC 65DC 10 MOUNTING/BARRIERS6 MOUNTING STYLE Threaded Insert 1 6-32 x 0.195 inches A 6-32 x 0.195 inches 2 ISO M3 x 5mm B ISO M3 x 5mm 3 6-32 x 0.195 inches C 6-32 x 0.195 inches 4 ISO M3 x 5mm D ISO M3 x 5mm 5 6-32 x 0.195 inches E 6-32 x 0.195 inches 6 ISO M3 x 5mm F ISO M3 x 5mm 7 6-32 x 0.195 inches G 6-32 x 0.195 inches 8 ISO M3 x 5mm H ISO M3 x 5mm 9 6-32 x 0.195 inches J 6-32 x 0.195 inches P ISO M3 x 5mm K ISO M3 x 5mm Q 6-32 x 0.195 inches L 6-32 x 0.195 inches U ISO M3 x 5mm M ISO M3 x 5mm ON-OFF B D G J L N Q S BARRIERS no yes no yes no yes no yes no yes no yes no yes no yes no yes no yes no yes no yes 11 MAX. APPLICATION RATING A 65DC D 250AC M 80DC 7 D C 11 Rating 12 Agency Approval Printed Circuitboard Terminals 90 Facing Left 90 Facing Right Straight Straight, Long Dual 1 2 3 4 5 6 7 8 Legend Color Black White White White White Black Black Black PUSH-TORESET no no no no yes yes yes yes no no no no yes yes yes yes no no no no yes yes yes yes 4 BRACKET COLOR Black Black Black Black Black Black Black Black White White White White White White White White Gray Gray Gray Gray Gray Gray Gray Gray FIG.B FIG. C 80VDC/250VAC8 12 AGENCY APPROVAL A Without approvals C UL Recognized, CSA Accepted, CCC Certified E UL Recognized, CSA Accepted, TUV Certified 5 UL Recognized, CSA Accepted, TUV Certified, CCC Certified special catalog # Notes: 1 Push-To-Reset actuator shave OFF portion of rocker shrounded 2 Standard multipole units have all poles identical, except when specifying auxiliary switch 3 Auxiliary switch available on Series Trip and Switch Only circuits to 32A. On multipole units, only one aux. switch is normally supplied, mounted in extreme right pole. 4 Separate Pole Type Voltage Coils not rated for continuous duty. Available only with delay code 10 & 20. Only Available w/ Agency code C. 5 For other current ratings, consult factory. 6 On Visi-Rocker,Visi portion of rocker cannot be the same color as the bezel. Remainder of rocker same color as bezel. 7 26-32A Polarity sensitive, only available as 1 pole unit. 8 Voltage code 4 available to 25A max. Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com 34 www.carlingtech.com L-Series Circuit Breaker L-Series Circuit Breaker The new L-Series Circuit Breaker is a compact, high performance breaker ideally suited for the rigors and confined spaces found in today’s telecom/datacom power distribution units and rack systems. The L-Series provides best in class performance in an innovative low profile, space saving package. The slick design complements the overall spatial objectives now required by telecommunications and datacommunications systems designers in their quest to reduce the overall size of equipment, while increasing transmission capacity. Further, a patent pending flush rocker actuator design and optional push-to-reset guard offers additional protection against accidental switching. Features: Ultra low profile design saves valuable space Optional handle guard actuator UL 489 LISTED Branch Circuit breaker Designed for worldwide datacenter compatibility with up to 240VAC ratings Applications: Telecom/Datacom Industry Power Distribution Units Data Servers Data Storage www.carlingtech.com 35 L-Series Circuit Breaker - General Specifications Environmental Electrical Voltage and Current Ratings Voltage (VAC) Current (A) 0.1 - 30 240 120/240 0.1 - 30 120/240 0.1 - 30 * 3rd pole to be neutral break Number of Poles 1 2 3* Environmental Operating Temp Vibration Time Delay Delay Curve Number 21 22 24 26 42 44 46 Voltage Description 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Ultrashort Short Medium Long Hi-inrush Short Hi-inrush Medium Hi-inrush Long Dielectric Strength Impedance UL, CSA-1960V 50/60 Hz for one minute between all electrically isolated terminals. Comply with the 8mm spacing and 3750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces and between main circuits of adjacent poles and from main circuit to auxiliary circuits per Publications EN 60950 and VDE 0805. RESISTANCE PER POLE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) Insulation Resistance Minimum of 100 Megohms@500VDC Overload 50 operations @ 600% of rated Interrupt Capacity current 5000 AMPs Shock Thermal Shock Moisture Resistance Salt Spray Physical Number of Poles Termination 1-3 poles Screw Terminals with the following thread sizes: 10-32, 8-32, M5, M4 Termination Barrier Standard for 2 & 3 poles constructions. Mounting Threaded Insert: #6-32 UNC-2B, or M3X0.5-6H B ISO (2 per Pole) Actuator Rocker, with or without guard. Internal Circuit Config. Series Trip Materials Housing - Glass Filled Polyester Rocker – Nylon 6/6 Weight ~107 Grams (~3.76 Ounces) per pole. Standard Color Housing - Black, Rocker - Black Mechanical Endurance Trip Free Regulatory Compliance Agency Approvals UL 489, CUL, TUV (EN60934-2) MIL-PRF-55629 and MIL-STD-202G -40ºC to +85 ºC Withstands 0.06” excursion from 10-55 Hz and 10Gs 55-500 Hz at rated current per MIL-PRF-55629 and MIL-STD202G, Method 204D, Test Condition A. Instantaneous and ultra-short curves tested at 90% of rated current. Withstands 100 Gs, 6 ms saw tooth while carrying rated current per MILPRF-55629 and MIL-STD-202G, Method 213B, Test Condition “I”. Instantaneous and ultra short curves tested at 90% of rated current. MIL-PRF-55629 and MIL-STD-202G, Method 107G, Condition A (5-cycles at -55ºC to +25ºC to +85ºC to +25ºC). MIL-PRF-55629 and MIL-STD-202G, Method 106G, i.e., Ten 24-hour cycles at +25ºC to +65ºC, 80-98% RH. Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96hrs) Trip Indication 10,000 “On-Off” Operations @ 6 per minute; 6000 cycles with rated Current and Voltage; 4000 cycles without electrical load. Trips on overload even when actuator is forcibly held in the “On” position. The operating actuator moves positively to the “Off” position when an overload causes the breaker to trip. *Manufacturer reserves the right to change product specification without prior notice. 36 www.carlingtech.com L-Series Circuit Breaker - Dimensional Specifications in.[mm] 1 POLE 2 POLE 3 POLE www.carlingtech.com 37 L-Series Circuit Breaker - Ordering Scheme L 1 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 24 5 Circuit 6 Frequency & Delay 620 7 Current Rating 2 4 E H 2 ACTUATOR Single Color Low Profile Rocker, Vertical Legend Single Color Low Profile Rocker, Horizontal Legend Single Color Push to Reset Low Profile Rocker, Vertical Legend Single Color Push to Reset Low Profile Rocker, Horizontal Legend One Two Three 4/5 CIRCUIT B0 Series Trip (current) 1 2 A B 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium 50/60Hz Long AMPERES 410 512 415 517 420 522 425 527 430 435 440 445 450 1.000 1.250 1.500 1.750 2.000 2.250 2.500 2.750 3.000 3.500 4.000 4.500 5.000 11 Rating 12 Agency Approval Screw Terminal, 8-32 (Bus Type) Screw Terminal, 10-32 (Bus Type) Screw Terminal, M4 (Bus Type) Screw Terminal, M5 (Bus Type) Dual Legend Color 1Black 2White 3White 4White 5White 6Black 7Black 8Black 455 460 465 470 475 480 485 490 495 610 710 611 711 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 11.000 11.500 6-32 X .195 Threaded Inserts ISO M3 X 5 mm Threaded Inserts 6-32 X .195 Threaded Inserts with Terminal Barrier ISO M3 X 5 mm Threaded Inserts with Terminal Barrier 11 MAX. APPLICATION RATING C 120/240 VAC (2 or 3 Pole only) D 240 VAC 7 CURRENT RATING (AMPERES) CODE 10 Mounting 10 MOUNTING INSERTS 6 FREQUENCY & DELAY 21 22 24 26 9 Actuator Color & Legend 9 ACTUATOR COLOR & LEGEND Actuator Color I-O ON-OFF White AB Black CD Red FG Green HJ Blue KL Yellow MN Gray PQ Orange RS 3 POLES 1 2 3 8 Terminal D G 8 TERMINAL 1 SERIES L 1 2 3 4 4 2 1 612 712 613 614 615 616 617 618 620 622 624 625 630 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 12 AGENCY APPROVAL A Without approvals G UL 489 Listed 3 UL 489 Listed, TUV Certified Notes: 1 3 Pole units available only when one of three poles is neutral 2 Terminal barriers are required on multi poles breaker *Not all constructions are available with all approvals. Consult Customer Service Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com 38 www.carlingtech.com A-Series Circuit Breaker A-Series Circuit Breaker Well known for their proven reliability, the A-Series hydraulic/magnetic circuit breakers are compact, temperature stable and designed for precision operation in OEM markets requiring general purpose as well as full load amp applications. The A-Series circuit breakers are offered with ratings from 0.02 to 50 amps, up to 277VAC or 80VDC and are available with several choices of pole configurations, time delays, terminals, with a wide range of standard colors, imprinting and actuator styles. Actuator styles include handle for 1-6 poles and rocker for 1-3 pole construction. When front panel operation and aesthetics demand a clean, contemporary design, a two-color or solid color VisiRocker actuator, indicating either the ON mode or the TRIPPED/OFF mode, is ideally suitable. The new Rockerguard bezel and push-to-reset bezel, which help prevent inadvertent actuation, is also available. Agency Certifications: UL Recognized – UL Standard 508, 1077, 1500 UL Listed – UL Standard 489A CSA Accepted TUV Certified VDE Certified www.carlingtech.com 39 A-Series Circuit Breaker - General Specifications Electrical Mechanical Maximum Voltage 277VAC 50/60 Hz, 80VDC Current Ratings Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 35.0, 40.0, 50.0. Other ratings available - consult ordering scheme. Standard Voltage Coils DC-6V, 12V; AC-120V, Other ratings available, consult ordering scheme. Auxiliary Switch Rating SPDT; 10.1 A - 250VAC, 1.0 A-65VDC/0.5 A - 80 VDC, 0.1A - 125VAC (with gold contacts). Insulation Resistance Minimum: 100 Megohms at 500 VDC Dielectric Strength UL, CSA - 1500V 60 Hz for one minute between all electrically isolated terminals. A-Series rocker circuit breakers comply with the 8mm spacing & 3750V dielectric requirements from hazardous voltage to operator accessible surfaces per EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker. Endurance Trip Free Trip Indication RESISTANCE PER POLE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) 10,000 ON-OFF operations @ 6 per minute; with rated Current & Voltage. All A-Series Circuit Breakers will trip on overload, even when the actuator is forcibly held in the ON position. The operating actuator moves positively to the OFF position when an overload causes the circuit breaker to trip. When mid-trip handle is specified, the handle moves to the mid position on electrical trip of the circuit breaker. When mid-trip handle with alarm switch is specified, the handle moves to the mid position & the alarm switch actuates when the circuit breaker is electrically tripped. Physical Number of Poles 1 - 6 Poles (handle) and 1-3 poles (rocker) at 30 Amps or less. 1 and 2 poles at 31 Amps thru 50 Amps. Internal Circuit Config. Series, (with or without auxiliary switch), Shunt and Relay with current or voltage trip coils, Dual Coil, Switch Only with or without auxiliary switch. Weight Approximately 65 grams/pole. (Approximately 2.32 ounces/pole) Standard Colors Housing - Black; Actuator- See Ordering Scheme. Environmental Pulse Tolerance Curves Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultra-short curves tested @ 90% of rated current. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 106D; ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH.56 days @ +85°C, 85% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C *Manufacturer reserves the right to change product specification without prior notice. 40 www.carlingtech.com A-Series Circuit Breaker - General Specifications Electrical Tables Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary Protector. Handle Notes: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 2 Same as note 1, except that backup fuse is limited to 80 A maximum. 3 2 pole protector required (with one pole per power line) for: 125/250 VAC, 1 pole protector required for : 125 VAC, 1Ø Power System. 4 Meets the requirements of CSA 22.2 No. 100-04 - Motors and Generators. www.carlingtech.com 41 A-Series Circuit Breaker - General Specifications Electrical Tables Table B: Lists UL Recognized, CSA Accepted, VDE & TUV Certified configurations & performance capabilities as a Component Supplementary Protector. 1 3 2 3 2 3 2 Notes: 1 General Purpose Ratings for UL/CSA Only. 2 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 3 Same as note 2, except that backup fuse is limited to 80 A maximum. 4 Meets the requirements of CSA 22.2 No. 100-04 - Motors and Generators. 42 www.carlingtech.com A-Series Circuit Breaker - General Specifications Electrical Tables Table C: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors. A-SERIES TABLE C: UL1500 (Marine Ignition Protected) VOLTAGE CIRCUIT CONFIGURATION SERIES CURRENT RATING SHORT CIRCUIT CAPACITY (AMPS) APPLICATION CODES MAX. RATING FREQUENCY PHASE FULL LOAD AMPS WITHOUT BACKUP FUSE UL CSA 14 1 DC --- 0.02 - 50 5000 TC1,OL1,U1 TC1,OL1,U1 1 32 65 DC --- 0.02 - 50 5000 TC1,OL1,U2 TC1,OL1,U2 DC --- 0.02 - 50 3000 TC1,OL1,U1 TC1,OL1,U1 125 50 / 60 1 0.02 - 50 3000 TC1,OL1,U2 TC1,OL1,U2 125 / 250 50 / 60 12 0.02 - 50 3000 TC1,OL1,U2 TC1,OL1,U2 250 50 / 60 1 0.02 - 30 1500 TC1,OL1,U1 TC1,OL1,U1 Notes: 1 Available with special catalog number only (consult factory). Notes: 2 2 pole protector required (with one per power line) for 125 / 250 VAC. 1 pole protector required for 125 VAC 1 phase power system 1 Available with Special Catalog Number Only (consult factory) 2 2 pole protector required (with one per power line) for 125 / 250 VAC. 1 pole protector required for 125 VAC 1 phase power system Table D: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (Guide DITT, File E189195), under UL489A. Notes: 1 Parallel Pole Construction Agency Certifications UL Recognized UL Standard 1077 Component Recognition Program as Protectors Supplementary (Guide CCN/QVNU2, File E75596) UL Standard 508 Switches, Industrial Control (Guide CCN/NRNT2, File E148683) UL Standard 1500 Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ2, File E75596) Ignition Protection UL Listed UL Standard 489A CSA Accepted Component Supplementary Protector under Class 3215 30, File 047848 0 000 CSA Standard C22.2 No. 235 TUV Certified EN60934, under License No. R72040875 VDE Certified EN60934, VDE 0642 under File No. 10537 Communications Equipment (Guide CCN/DITT, File E189195) www.carlingtech.com 43 A-Series Handle UL489A – Ordering Scheme A A 1 1 Series 2 Actuator 3 Poles B 0 4 Circuit 5 Aux/Alarm Switch 14 6 Frequency & Delay 2 ACTUATOR1 Handle, one per pole Mid-Trip Handle, one per pole Mid-Trip Handle, one per pole & Alarm Switch 3 POLES2 1 2 3 4 One Two Three Four Series Trip (Current) 5 AUXILIARY/ALARM SWITCH2 0 1 2 3 w/o Aux Switch S.P.D.T., 0.093 Q.C. Term. S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug 6 FREQUENCY & DELAY 11 12 14 16 DC Ultra Short DC Short DC Medium DC Long 7 8 9 S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 523 DC, Short,Hi-Inrush 543 DC, Medium, Hi-Inrush 563 DC, Long, Hi-Inrush AMPERES 2100.100 2150.150 2200.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 8 TERMINAL5 1 6 2 37 4 57 6 7 8 10 Mounting/ Barriers M T 11 Max. Appl. Rating 12 Agency Approval 1 A 2 B 5 6 7 8 MOUNTING STYLEBARRIERS Threaded Insert, 2 per pole 6-32 x 0.195 inches no 6-32 x 0.195 inches yes ISO M3 x 5mm no ISO M3 x 5mm (multipole only) yes Front panel Snap-In, 0.75” wide bezel without Handleguardno without Handleguard (multipole only) yes Front panel Snap-In, 0.96” wide bezel without Handleguard, 1-pole 0.96” wide; no multipole units have .105” bezel overhang on all sides without Handleguard, 1-pole 0.96” wide; yes (multipole only) .105” bezel overhang on all sides 11 MAXIMUM APPLICATION RATING M 7 CURRENT RATING (AMPERES) CODE 9 Actuator Color 10 MOUNTING/BARRIERS 4 CIRCUIT B 1 B 1 8 Terminal 9 ACTUATOR COLOR & LEGEND Actuator Color I-O Dual Legend Color White B1 Black Black D2 White Red G3White Green J4White Blue L5White Yellow N6Black Gray Q7Black Orange S8Black Black (short handle)10 U9White 1 SERIES A A S T 450 7 Current Rating 2850.850 2900.900 2950.950 4101.000 5121.250 4151.500 517 1.750 4202.000 5222.250 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 Push-On 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (Bus Type) Screw 10-32 w/upturned lugs Screw 10-32 (Bus Type) Screw 8-32 w/upturned lugs and 30° bend Screw 8-32 (Bus Type) and 30° bend Screw 10-32 w/upturned lugs and 30° bend 4555.500 4606.000 4656.500 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 610 10.000 71010.500 611 11.000 71111.500 61212.000 71212.500 9 B F G H M7 P8 Q9 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635335.000 640340.000 645345.000 650350.000 Screw 10-32 (Bus Type) and 30° bend Screw M5 w/upturned lugs Screw M5 w/upturned lugs and 30° bend Screw M5 (Bus Type) and 30° bend Screw M5 (Bus Type) M6 Threaded Stud Printed Circuit Board Terminals Push-In Stud 80 DC 12 AGENCY APPROVAL T K J UL489A LISTED UL489A LISTED, VDE CERTIFIED UL489A LISTED, TUV CERTIFIED Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. 2 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 3 VDE Certified to 30 amps. UL489A Listed to 50 amps. 4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9 G, H, M and Q. 6 Terminal Code 1 (Push-On) available up to 25 amps with VDE Certification and 30 amps with UL489A Listing, but is not recommended over 20 amps. 7 Terminal Codes 3, 5 and H (Bus Type) with VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE Certified when the washers are used. 8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Single pole only. Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com 44 www.carlingtech.com A-Series Rocker UL489A – Ordering Scheme A F 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 14 5 Aux/Alarm Switch 6 Frequency & Delay 1 SERIES A 450 7 Current Rating 1 3 1 8 Terminal 9 Actuator Color 10 Mounting/ Barriers 8 TERMINAL5 2 ACTUATOR1 Two Color Visi-Rocker Indicate ON, vertical legend C D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend Single color J Vertical legend K Horizontal legend Push-To-Reset, Visi-Rocker Indicate OFF, N vertical legend O Indicate OFF, horizontal legend Push-To-Reset , Single color R Vertical legend U Horizontal legend 16 2 37 4 57 6 7 8 Push-On 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (Bus Type) Screw 10-32 w/upturned lugs Screw 10-32 (Bus Type) Screw 8-32 w/upturned lugs and 30° bend Screw 8-32 (Bus Type) and 30° bend Screw 10-32 w/upturned lugs and 30° bend 9 B F G H M7 P8 Q9 M T 11 Max. Appl. Rating 12 Agency Approval Screw 10-32 (Bus Type) and 30° bend Screw M5 w/upturned lugs Screw M5 w/upturned lugs and 30° bend Screw M5 (Bus Type) and 30° bend Screw M5 (Bus Type) M6 Threaded Stud Printed Circuit Board Terminals Push-In Stud 9 ACTUATOR COLOR & LEGEND Actuator or Visi-Color10 White Black Red Green Blue Yellow Gray Orange 10 MOUNTING/BARRIERS11 3 POLES2 1 2 One 3 Two Three 4 CIRCUIT B Series Trip (Current) 5 AUXILIARY/ALARM SWITCH3 0 1 2 3 w/o Aux Switch S.P.D.T., 0.093 Q.C. Term. S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug 6 FREQUENCY & DELAY 11 12 14 16 DC Ultra Short DC Short DC Medium DC Long 7 8 9 S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 52 54 56 DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush AMPERES 2100.100 2150.150 2200.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 1 A 2 B 3 C 4 D 8 H 9 J STANDARD ROCKER BEZEL BARRIERS Threaded Insert, 2 per pole 6-32 x 0.195 inches no 6-32 X 0.195 inches (multi-pole units only) yes ISO M3 x 5mm no ISO M3 x 5mm (multi-pole units only) yes ROCKERGUARD & PUSH-TO-RESET BEZEL Threaded Insert, 2 per pole 6-32 x 0.195 inches no 6-32 x 0.195 inches (multi-pole units only) yes ISO M3 x 5mm no ISO M3 x 5mm (multi-pole units only) yes FRONT PANEL SNAP-IN BRACKET, 0.744” [18.90mm] wide bezel without Rockerguard (single pole units only) no with Rockerguard (single pole units only) no FRONT PANEL SNAP-IN BRACKET, 0.96” [24.48mm] wide bezel without Rockerguard (single pole units only) no with Rockerguard (single pole units only) no 11 MAXIMUM APPLICATION RATING M 7 CURRENT RATING (AMPERES) CODE Marking: Marking Color ON-OFFDual10 Single Color Visi-Rocker B1Black White D2White n/a G3White Red J4White Green L5White Blue N6Black Yellow Q7Black Gray S8Black Orange 2850.850 2900.900 2950.950 4101.000 5121.250 4151.500 517 1.750 4202.000 5222.250 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 4555.500 4606.000 4656.500 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 610 10.000 71010.500 611 11.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635435.000 640440.000 645445.000 650450.000 80 DC 12 AGENCY APPROVAL T K J UL489A LISTED UL489A LISTED, VDE CERTIFIED UL489A LISTED, TUV CERTIFIED Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. 3 Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. 6 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30 amps with UL489A Listing, but is not recommended over 20 amps. 7 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used. 8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend. 11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through K Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com www.carlingtech.com 45 A-Series Handle – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Alarm Switch available with .110 x .020 Q.C. & Solder Lug Terminals Only. 46 www.carlingtech.com A-Series Handle – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Alarm Switch available with .110 x .020 QC & solder lug terminals only. www.carlingtech.com 47 A-Series Handle – Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ± 0.20 [.51] unless otherwise specified. 3 For agency code P = .150 [3.81]. 48 www.carlingtech.com A-Series Handle – Front Panel Snap-In Mounting Style 5 Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 49 A-Series Handle – Front Panel Snap-In Mounting Style 7 Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 Tolerance ±.020 [.51] unless otherwise specified. 50 www.carlingtech.com A-Series Flat Rocker UL Recognized – Ordering Scheme A 1 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 24 5 Aux/Alarm Switch 630 6 Frequency & Delay 7 Current Rating 8 TERMINAL11 1 SERIES A 112 2 313 4 513 6 7 8 9 B C 2 ACTUATOR1 Two Color Visi-Rocker Indicate OFF, vertical legend 1 2 Indicate OFF, horizontal legend Single color 3 Vertical legend 4 Horizontal legend Push-To-Reset, Visi-Rocker Indicate OFF, vertical legend 5 6 Indicate OFF, horizontal legend Push-To-Reset , Single color 7 Vertical legend 8 Horizontal legend 2 One 3 Two F 4 G4 H4,5 K4,5 Relay Trip (Current) Relay Trip (Voltage) Dual Coil with Shunt Trip Voltage Coil Dual Coil with Relay Trip Voltage Coil 5 AUXILIARY/ALARM SWITCH6,7 5 6 7 8 9 S.P.S.T., 0.093 Q.C. Term. (Gold Contacts) S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 30 31 32 34 36 429 449 469 529 549 56 DC, 50/60Hz Instantaneous DC, 50/60Hz Ultra Short DC, 50/60Hz Short DC, 50/60Hz Medium DC, 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush 0 1 2 3 4 Switch Only (No Coil) Series Trip (Current) Series Trip (Voltage) Shunt Trip (Current) Shunt Trip (Voltage) w/o Aux Switch S.P.D.T., 0.093 Q.C. Term. S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY 03 106 11 12 14 16 206 21 22 24 26 DC 50/60Hz, Switch Only DC Instantaneous DC Ultra Short DC Short DC Medium DC Long 50/60Hz Instantaneous 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium 50/60Hz Long 7 CURRENT RATING (AMPERES) CODE AMPERES 0200.020 0250.025 0300.030 0350.035 0400.040 0450.045 0500.050 0550.055 0600.060 0650.065 0700.070 0750.075 0800.080 0850.085 0900.090 0950.095 2100.100 2150.150 2200.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 2850.850 2900.900 2950.950 4101.000 5121.250 4151.500 517 1.750 4202.000 5222.250 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 4555.500 4606.000 4656.500 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 610 10.000 71010.500 611 11.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 6351035.000 6401040.000 6451045.000 6501050.000 A06 6 DC A12 12 DC A18 18 DC A24 24 DC A32 32 DC A48 48 DC A65 65 DC J06 6 AC J12 J18 J24 J48 J65 65 AC K20 120 AC L40 240 AC OR VOLTAGE COIL (NORMAL RATED VOLTAGE)8 12 AC 18 AC 24 AC 48 AC Actuator or Visi-Color17 White Black Red Green Blue Yellow Gray Orange Three 4 CIRCUIT A 3 B C D4 E4 Push-On 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (Bus Type) Screw 10-32 w/upturned lugs Screw 10-32 (Bus Type) Screw 8-32 w/upturned lugs and 30° bend Screw 8-32 (Bus Type) and 30° bend Screw 10-32 w/upturned lugs and 30° bend Screw 10-32 (Bus Type) and 30° bend Screw M5 w/upturned lugs Screw M4 w/upturned lugs 9 Actuator Color E13 F G H13 L14 M13 P15 Q R S16 T 10 Mounting/ Barriers E 11 Agency Approval Screw M4 (Bus Type) Screw M5 w/upturned lugs and 30° bend Screw M5 (Bus Type) and 30° bend Screw M5 (Bus Type) 0.250 Q.C./ Solder Lug M6 Threaded Stud Printed Circuit Board Terminals Push-In Stud Screw M4 w/upturned lugs and 30° bend Push-On 0.110 Tab (Q.C.) Screw M4 (Bus Type) and 30° bend 9 ACTUATOR COLOR & LEGEND 3 POLES2 1 2 3 1 8 Terminal Marking: Marking Color I-OON-OFF Dual17 Single Color Visi-Rocker AB 1Black White CD 2White n/a FG 3White Red HJ 4White Green KL 5White Blue MN 6Black Yellow PQ 7Black Gray RS 8Black Orange 10 MOUNTING/BARRIERS18 1 A 2 B 5 E 6 F 3 C 4 D STANDARD ROCKER BEZEL,Threaded Insert, 2 per poleBARRIERS FLAT ROCKER ACTUATOR 6-32 x 0.195 inches no 6-32 X 0.195 inches (multi-pole units only) yes ISO M3 x 5mm no ISO M3 x 5mm (multi-pole units only) yes RECESSED OFF SIDE ROCKER ACTUATOR19 6-32 x 0.195 inches no 6-32 x 0.195 inches (multi-pole units only) yes ISO M3 x 5mm no ISO M3 x 5mm (multi-pole units only) yes PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole 6-32 x 0.195 inches no 6-32 x 0.195 inches (multi-pole units only) yes ISO M3 x 5mm no ISO M3 x 5mm (multi-pole units only) yes 11 AGENCY APPROVAL C E I UL Recognized & CSA Accepted TUV Certified, UL Recognized & CSA Accepted UL Rec. STD 1077, UL Rec. 1500 (ignition protected), & CSA Accepted Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. 3 Switch Only circuits, rated up to 50 amps & 3 poles. Only available when tied to a protected pole. For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650. 4 Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum. 5 Consult factory for Dual Coil options, as special catalog number is required. With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA minimum power to trip and are rated for intermittent duty only. 6 Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 7 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 8 Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 & 20. 9 Available with Circuit Codes B & D only. UL Recognized, CSA Accepted & TUV Certified to 50 amps. 10 UL Recognition, CSA Acceptance & TUV Certification available in one and two pole breakers. 11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. 12 Terminal Code 1: Available up to 30 amps, but not recommended over 20 amps. 13 Terminal Codes 3, 5 E & H (Bus Type) with TUV, are supplied with Lock Washers; Terminal Code M (M6 Threaded Stud) with TUV is supplied with Lock and Flat Washers. These breakers are only TUV Certified when the washers are used. 14 TUV Cert. available up to 12 amps. UL Rec. & CSA Accepted available up to 30 amps. 15 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 50 amps with UL Recognition, CSA Accepted & TUV Certification, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL Recognition and CSA Accepted with Circuit Codes A, B and C. 16 Terminal Code S used on voltage coil circuit constructions only. 17 Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O legend. 18 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes 5 & 6. 19 Recessed “off-side” available with actuator codes 1, 2, 3 & 4. Legends on rocker are available in ink stamping only. Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com www.carlingtech.com 51 A-Series Flat Rocker UL 489A – Ordering Scheme A 1 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 14 5 Aux/Alarm Switch 6 Frequency & Delay 1 SERIES A 630 7 Current Rating 2 3 1 8 Terminal 9 Actuator Color 10 Mounting/ Barriers 8 TERMINAL5 2 ACTUATOR1 Two Color Visi-Rocker Indicate ON, vertical legend C D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend Single color J Vertical legend K Horizontal legend Push-To-Reset, Visi-Rocker Indicate OFF, N vertical legend O Indicate OFF, horizontal legend Push-To-Reset , Single color R Vertical legend U Horizontal legend 1 7 2 38 4 58 6 7 8 9 B F G H 8 M8 P9 Q10 Push-On 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (Bus Type) Screw 10-32 w/upturned lugs Screw 10-32 (Bus Type) Screw 8-32 w/upturned lugs and 30° bend Screw 8-32 (Bus Type) and 30° bend Screw 10-32 w/upturned lugs and 30° bend M T 11 Max. Appl. Rating 12 Agency Approval Screw 10-32 (Bus Type) and 30° bend Screw M5 w/upturned lugs Screw M5 w/upturned lugs and 30° bend Screw M5 (Bus Type) and 30° bend Screw M5 (Bus Type) M6 Threaded Stud Printed Circuit Board Terminals Push-In Stud 9 ACTUATOR COLOR & LEGEND Actuator or Visi-Color11 White Black Red Green Blue Yellow Gray Orange 10 MOUNTING/BARRIERS12 3 POLES2 1 2 One 3 Two Three 4 CIRCUIT B Series Trip (Current) 5 AUXILIARY/ALARM SWITCH3 0 1 2 3 w/o Aux Switch S.P.D.T., 0.093 Q.C. Term. S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug 6 FREQUENCY & DELAY 11 12 14 16 DC Ultra Short DC Short DC Medium DC Long 7 8 9 S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 52 54 56 DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush AMPERES 2100.100 2150.150 2200.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 2850.850 2900.900 2950.950 4101.000 5121.250 4151.500 517 1.750 4202.000 5222.250 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 1 A 2 B 5 E 6 F 3 C 4 D STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole FLAT ROCKER ACTUATOR 6-32 x 0.195 inches 6-32 X 0.195 inches (multi-pole units only) ISO M3 x 5mm ISO M3 x 5mm (multi-pole units only) RECESSED OFF SIDE ROCKER ACTUATOR 13 6-32 x 0.195 inches 6-32 x 0.195 inches (multi-pole units only) ISO M3 x 5mm ISO M3 x 5mm (multi-pole units only) PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole 6-32 x 0.195 inches 6-32 x 0.195 inches (multi-pole units only) ISO M3 x 5mm ISO M3 x 5mm (multi-pole units only) BARRIERS no yes no yes no yes no yes no yes no yes 11 MAXIMUM APPLICATION RATING M 80 DC 12 AGENCY APPROVAL 7 CURRENT RATING (AMPERES) CODE Marking: Marking Color ON-OFFDual11 Single Color Visi-Rocker B1Black White D2White n/a G3White Red J4White Green L5White Blue N6Black Yellow Q7Black Gray S8Black Orange 4555.500 4606.000 4656.500 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 610 10.000 71010.500 611 11.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635435.000 640440.000 645445.000 650450.000 T J UL489A LISTED UL489A LISTED, TUV CERTIFIED Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. 3 Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with standard half shells. 30-50A are supplied with extended boat (B-Style) half shells. 4 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 5 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, M and Q. 6 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30 amps with UL489A Listing, but is not recommended over 20 amps. 7 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used. 8 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL489A Listing. 9 Terminal Code Q not available with VDE certification. 10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend. 11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes N & O. Rockerguard available with actuator codes C through K Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com 52 www.carlingtech.com A-Series Rocker – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Schematic shown represents current trip circuit. 4 Circuits shown for >30 amps / VDE. www.carlingtech.com 53 A-Series Rocker – Form & Fit Drawings Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate OFF is opposite of indicate ON. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 All dimensions are in inches [millimeters]. 4 Tolerance ± 0.20 [.51] unless otherwise specified. 54 www.carlingtech.com A-Series Rocker Snap-In Bracket – Form & Fit Drawings Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. Orientation on indicate “OFF” is opposite of indicate “ON” 3 Recommended panel thickness: .04 0 [1.02] to .100 [2.54] 4 All dimensions are in Inches [millimeters]. 5 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 55 A-Series Flat Rocker – Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 Tolerance ± 0.20 [.51] unless otherwise specified. 56 www.carlingtech.com A-Series PC Terminal Diagrams Notes: 1 Drawing illustrates A-Series with VDE certification. 2 All dimensions are in inches [millimeters]. 3 Tolerance ± 0.20 [.51] unless otherwise specified www.carlingtech.com 57 B-Series Circuit Breaker B-Series Circuit Breaker The B-Series hydraulic/magnetic circuit breakers are compact and temperature stable designed for precision operation in OEM markets requiring general purpose as well as full load amp applications. These circuit breakers are designed specifically for world market applications requiring extra insulation and tongue & groove half-shell constructions. Actuators available include handle for 1- 6 poles, rocker for 1-3 poles, and Visi-Rocker for 1-3 poles construction. They are also offered with ratings from 0.02 to 50 amps and up to 277VAC or 80VDC, with choices of time delays, terminals, wide range of standard colors, imprinting. Agency Certifications: UL Recognized – UL Standard 508, 1077, 1500 UL Listed – UL Standard 489, 489A CSA Accepted TUV Certified VDE Certified 58 www.carlingtech.com B-Series Circuit Breaker - General Specifications Electrical Mechanical Maximum Voltage 277VAC 50/60 Hz, 80VDC Current Ratings Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 20.0, 25.0, 30.0, 35.0, 40.0 and 50.0 amps. Other ratings available, see ordering scheme. Standard Voltage Coils DC - 6V, 12V; AC - 120V, other ratings available, see ordering scheme. Auxiliary Switch Rating SPDT; 10.1 AMPS - 250VAC,1.0A 65 VDC or 0.5A 80 VDC, 0.1 Amps - 125VAC (with gold contacts). VDE-1.0 Amp - 125VAC. Insulation Resistance Minimum of 100 Megohms at 500 VDC. Dielectric Strength UL, CSA-1500 V 50/60 Hz for one minute between all electrically isolated terminals. B-Series circuit breakers comply with the 8mm spacing and 3750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker. Endurance 10,000 ON-OFF operations @ 6 per minute; with rated Current and Voltage. Trip Free All B-Series Circuit Breakers will trip on overload, even when Handle is forcibly held in the ON position. Trip Indication The operating Handle moves positively to the OFF position when an overload causes the breaker to trip. RESISTANCE PER POLE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) Pulse Tolerance Curves Physical Number of Poles 1 - 6 poles at 30 Amps or less. 1 and 2 poles at 31 Amps thru 50 Amps. Internal Circuit Config. Series, (with or without auxiliary switch), Shunt and Relay with current or voltage trip coils, Dual Coil, Switch Only (with or without auxiliary switch). Weight Approximately 65 grams/pole. (Approximately 2.32 ounces/pole.) Standard Colors Housing- Black; Actuator - See Ordering Scheme. Environmental Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultra-short curves tested @ 90% of rated current. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 106D, i.e., ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C *Manufacturer reserves the right to change product specification without prior notice. www.carlingtech.com 59 B-Series Circuit Breaker - General Specifications Electrical Tables Table A: Lists UL Recognized & CSA Certified configurations and performance capabilities as a Component Supplementary Protector. Notes: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 2 Same as note 1, except that backup fuse is limited to 80A maximum. 3 2 pole protector required (with one pole per power line) for: 250/125 VAC, 125/250 VAC and 208Y/120 VAC Power Systems. 1 pole protector required for : 125 VAC, 1Ø Power System. 60 www.carlingtech.com B-Series Circuit Breaker - General Specifications Electrical Tables Table B: Lists UL Recognized, CSA, VDE & TUV Certified configurations & performance capabilities as a Component Supplementary Protector. Notes: 1 General Purpose Ratings for UL/CSA Only. 2 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector. 3 Same as note 1, except that backup fuse is limited to 80 A maximum. Table C: Lists UL Recognized, CSA Certified configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (CCN/Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (CCN/Guide UZMK, File MQ1515) as Marine Supplementary Protectors. Notes: 1 Available with special catalog number only (consult factory). 2 2 pole protector required (with one pole per power line) for: 250/125 VAC, 125/250 VAC and 208Y/120 VAC Power Systems. 1 pole protector required for : 125 VAC, 1Ø Power System. www.carlingtech.com 61 B-Series Circuit Breaker - General Specifications Table D: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (CCN/Guide DITT, File E189195), under UL489A Notes: 1 Parallel Pole Construction Table E: Lists UL Listed (489) configuration and performance capabilities as a Molded Case Circuit Breaker. B SERIES TABLE E : UL489 LISTED BRANCH CIRCUIT BREAKERS VOLTAGE CIRCUIT CONFIGURATION MAX. RATING FREQUENCY PHASE SERIES SHUNT TRIP DUAL COIL CURRENT RATING INTERRUPTING CAPACITY (AMPS) FULL LOAD AMPS WITHOUT BACKUP FUSE CONSTRUCTION NOTES 120 50 / 60 1 0.10 - 30 5,000 1 Pole 120 / 240 50 / 60 1 0.10 - 30 5,000 2 Poles 120 / 240 50 / 60 1 0.10 - 30 5,000 2 or 3 Poles (1 Pole of a 3 Pole Unit is for Neutral Break) 120 50 / 60 1 0.10 - 30 5,000 1 Pole 120 / 240 50 / 60 1 0.10 - 30 5,000 2 Poles 120 / 240 50 / 60 1 0.10 - 30 5,000 2 or 3 Poles (1 Pole of a 3 Pole Unit is for Neutral Break) Agency Certifications UL Recognized UL Standard 1077 Component Recognition Program as Protectors Supplementary (Guide CCN/QVNU2, File E75596) UL Standard 508 Switches, Industrial Control (Guide CCN/NRNT2, File E148683) UL Standard 1500 Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ2, File E75596) Ignition Protection UL Listed UL Standard 489 UL Standard 489A 62 CSA Accepted Component Supplementary Protector under Class 3215 30, FIle 047848 0 000 CSA Standard C22.2 No. 235 TUV Certified EN60934, under License No. R72040875 VDE Certified EN60934, VDE 0642 under File No. 10537 Circuit Breakers, Molded Case, (Guide DIVQ, File E129899) Communications Equipment (Guide CCN/DITT, File E189195) www.carlingtech.com B-Series Handle UL489A – Ordering Scheme B A 1 1 Series 2 Actuator 3 Poles B 0 4 Circuit 5 Aux/Alarm Switch 14 6 Frequency & Delay 2 ACTUATOR1 Handle, one per pole Handle, one per multipole unit Mid-Trip Handle, one per pole Mid-Trip Handle, one per pole & Alarm Switch 3 POLES2 1 2 One Two 3 4 Three Four 7 8 9 S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 52 54 56 DC, Short,Hi-Inrush DC, Medium, Hi-Inrush DC, Long, Hi-Inrush Series Trip (Current) 5 AUXILIARY/ALARM SWITCH2 0 1 2 3 w/o Aux Switch S.P.D.T., 0.093 Q.C. Term. S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug 6 FREQUENCY & DELAY4 11 12 14 16 DC Ultra Short DC Short DC Medium DC Long 7 CURRENT RATING (AMPERES) CODE AMPERES 2100.100 2150.150 2200.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 2850.850 2900.900 2950.950 4101.000 5121.250 4151.500 517 1.750 4202.000 5222.250 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 8 TERMINAL4 15 2 36 4 56 6 7 8 9 Push-On 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (Bus Type) Screw 10-32 w/upturned lugs Screw 10-32 (Bus Type) Screw 8-32 w/upturned lugs and 30° bend Screw 8-32 (Bus Type) and 30° bend Screw 10-32 w/upturned lugs and 30° bend Screw 10-32 (Bus Type) and 30° bend 4555.500 4606.000 4656.500 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 610 10.000 71010.500 611 11.000 71111.500 61212.000 71212.500 B F G H J K M6 N P7 Q8 Y 9 Actuator Color 10 Mounting/ Barriers M T 11 Max. Appl. Rating 12 Agency Approval 10 MOUNTING/BARRIERS 4 CIRCUIT B 1 B 1 8 Terminal 9 ACTUATOR COLOR & LEGEND Actuator Color ON-OFF Dual Legend Color White B1Black Black D2White Red G3White Green J4White Blue L5White Yellow N6Black Gray Q7Black Orange S8Black 1 SERIES B A B S T 450 7 Current Rating 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 635335.000 640340.000 645345.000 650350.000 Screw M5 w/upturned lugs Screw M5 w/upturned lugs and 30° bend Screw M5 (Bus Type) and 30° bend Screw M5 (Bus Type) Screw M5 Back Connect Screw 10-32 Back Connect M6 Threaded Stud Screw M4 Back Connect Printed Circuit Board Terminals Push-In Stud Screw 8-32 Back Connect 1 A 2 B 3 C 4 D 5 6 7 8 MOUNTING STYLEBARRIERS Threaded Insert, 2 per pole 6-32 x 0.195 inches no 6-32 x 0.195 inches (multi-pole units only) yes ISO M3 x 5mm no ISO M3 x 5mm yes Rectangular Adapter Plate with mounting centers of 2.062 inches [52.37mm] and Threaded insert, 2 per pole 6-32 x 0.225 inches no 6-32 X 0.225 inches (multi-pole units only) yes ISO M3 x 6.5mm no ISO M3 x 6.5mm yes Front panel Snap-In, 0.75” [19.05mm] wide bezel without Handleguardno without Handleguard (multipole only) yes Front panel Snap-In, 0.96” wide bezel without Handleguard, 1-pole 0.96” wide; no multipole units have .105” bezel overhang on all sides without Handleguard, 1-pole 0.96” wide; yes (multipole only) .105” bezel overhang on all sides 11 MAXIMUM APPLICATION RATING M 80 DC 12 AGENCY APPROVAL T K J UL489A LISTED UL489A LISTED, VDE CERTIFIED UL489A LISTED, TUV CERTIFIED Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. 2 On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole. 3 VDE Certification available with single pole breakers only. UL489A Listing available with one and two pole breakers. 4 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only available with Terminal Codes 5, 9, G, H, J, K, M and Q. 5 Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30 amps with UL489A Listing, but is not recommended over 20 amps. 6 Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, and Terminal Code M (M6 Threaded Stud) with TUV or VDE is supplied with Lock and Flat Washers. These breakers are only TUV or VDE Certified when the washers are used. 7 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with VDE Certification and 50 amps with UL489A Listing. 8 Terminal Code Q not available with VDE approvals. Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com www.carlingtech.com 63 B-Series Handle UL489 Listed – Ordering Scheme B A 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 24 5 Aux/Alarm Switch 6 Frequency & Delay 450 7 Current Rating 2 ACTUATOR1 Handle, one per pole Handle, one per multipole unit Mid-Trip Handle, one per pole Mid-Trip Handle, one per pole & Alarm Switch 3 POLES2 1 2 One 3 3 Two Three A B C D 6 8 Series Trip (Current) 5 AUXILIARY/ALARM SWITCH4 0 1 2 w/o Aux Switch S.P.D.T., 0.093 Q.C. Term. S.P.D.T., 0.110 Q.C. Term. 6 FREQUENCY & DELAY 21 22 24 26 AC Ultra Short AC Short AC Medium AC Long 10 Mounting/ Barriers K G 11 Max. Appl. Rating 12 Agency Approval 10 MOUNTING/BARRIERS 4 CIRCUIT B 9 Actuator Color 9 ACTUATOR COLOR & LEGEND6 Actuator Color ON-OFF Dual Legend Color White B1 Black Black D2 White Red G3White Green J4White Blue L5White Yellow N6Black Gray Q7Black Orange S8Black 1 SERIES B A B S T 1 B A 8 Terminal 3 8 9 S.P.D.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 42 44 46 AC, Short,Hi-Inrush AC, Medium, Hi-Inrush AC, Long, Hi-Inrush MOUNTING STYLEBARRIERS Threaded Insert, 2 per pole 6-32 x 0.195 inches (multi-pole units only) yes ISO M3 x 5mm yes Rectangular Adapter Plate with mounting centers of 2.062 inches [52.37mm] and Threaded insert, 2 per pole7 6-32 X 0.225 inches (multi-pole units only) yes ISO M3 x 6.5mm yes Front panel Snap-In, 0.75” [19.05mm] wide bezel without Handleguard (multipole only) yes Front panel Snap-In, 0.96” wide bezel without Handleguard, 1-pole 0.96” wide; yes (multipole only) .105” bezel overhang on all sides 11 MAXIMUM APPLICATION RATING C8120/240VAC K120VAC 7 CURRENT RATING (AMPERES) CODE AMPERES 2100.100 2150.150 2200.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 8 TERMINAL5 1 2 3 4 5 6 7 8 9 2800.800 2850.850 2900.900 2950.950 4101.000 5121.250 4151.500 517 1.750 4202.000 5222.250 5272.750 4303.000 4353.500 4404.000 Push-On 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (Bus Type) Screw 10-32 w/upturned lugs Screw 10-32 (Bus Type) Screw 8-32 w/upturned lugs and 30° bend Screw 8-32 (Bus Type) and 30° bend Screw 10-32 w/upturned lugs and 30° bend Screw 10-32 (Bus Type) and 30° bend 4454.500 4505.000 4555.500 4606.000 4656.500 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 610 10.000 71010.500 611 11.000 A B F G H J K M N Q Y 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 Load Terminal: #8 Screw/QC Combination. (Special Cat.#) Screw M5 w/upturned lugs Screw M5 w/upturned lugs and 30° bend Screw M5 (Bus Type) and 30° bend Screw M5 (Bus Type) Screw M5 Back Connect Screw 10-32 Back Connect M6 Threaded Stud Screw M4 Back Connect Push-In Stud Screw 8-32 Back Connect 12 AGENCY APPROVAL G 3 UL489 Listed UL489 Listed, TUV Certified Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units. B: Handle location as viewed from front of breaker: 2 pole - left pole 3 pole - center pole S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B, C, D, E, F, G, H and K. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B & C. 2 All poles must be same polarity. 3 3 pole units available only when 1 of 3 poles is neutral. 4 Auxiliary/Alarm Switch circuit must be same polarity as the main circuit. On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 5 Screw Terminals are recommended on ratings greater than 20 amps. 6 Standard actuator colors are black and white. 7 Adapter plate with mounting centers of 2.082 inches. Available with Actuator Codes A, S and T. 8 Voltage Rating available with 2 and 3-pole breakers only. 9 Barriers supplied on multi-pole units only. Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com 64 www.carlingtech.com B-Series Handle – Circuit & Terminal Diagrams SERIES TRIP (2 TERM'S.) ANSI LINE (NETZ) LINE IEC SERIES TRIP LINE MAIN TERM'S. (SEE TABLE A) A CIRCUIT CODE AUX SWITCH CODE CIRCUIT SCHEMATIC CIRCUIT CODE AUX SWITCH CODE CIRCUIT SCHEMATIC ANSI IEC SWITCH ONLY (NO COIL) LINE (3) (NETZ) O B C O B C 2 3 4 H 0 K 0 I> LOAD (LAST) LOAD 1.730 [43.94] LOAD LOAD (LAST) SERIES TRIP WITH AUXILIARY / ALARM SWITCH SWITCH ONLY (NO COIL) WITH AUXILIARY SWITCH .520 [13.21] SERIES TRIP W AUX SWITCH (5 TERM'S.) C NO NC AUX. SWITCH TERM'S. LINE LINE (NETZ) LINE C C NO NO NC NC A 2 3 4 LINE LINE (NETZ) LOAD (3) SHUNT (NEBENSCHLUSS) D E 3 LINE (NETZ) LINE (3) (NETZ) LINE F G 4 4 RELAY (RELAIS) RELAY STANDARD C/B HANDLE POSITION 3 2 1 HANDLE POSITION I> 4 LOAD (LAST) LOAD VOLTAGE COIL VOLTAGE COIL 2 U> 3 VOLTAGE COIL MID TRIP C/B ALARM SWITCH MODE HANDLE POSITION 30° 30° VOLTAGE COIL 4 LOAD (LAST) MID TRIP C/B AUX. SWITCH MODE U> 0 HANDLE POSITION VS. AUX/ALARM SWITCH MODE CIRCUIT BREAKER MODE LINE (NETZ) 1 1 I> 3 .390 [9.91] LOAD (LAST) LOAD LOAD 4 I> 2 RELAY 3 LOAD (LAST) DUAL COIL; SERIES TRIP CURRENT COIL, RELAY TRIP VOLTAGE COIL 2 2 NC ALARM SWITCH VOLTAGE COIL RELAY (RELAIS) 1 .780 [19.81] I> 0 LOAD (LAST) LINE 1 NO LINE RELAY TRIP RELAY TRIP (4 TERM'S.) NO LOAD I> .390 [9.91] C DUAL COIL; SERIES TRIP CURRENT COIL, SHUNT TRIP VOLTAGE COIL SHUNT TRIP (3 TERM'S.) SHUNT C NC SHUNT TRIP (3) STD. AUX. SWITCH ALARM SWITCH LOAD (LAST) LOAD LINE (NETZ) STD. AUX. SWITCH AUX. SWITCH MODE (w/o ALARM SWITCH) 30° OFF F O OF NC NO C F O OF NC NO C F O OF NC NO C NC NO C NC NO C ON ON ON I I I ON 30° NC NO 30° ELECTRICAL TRIP F O OF 30° C MID TRIP NC NO C NC NO 30° C 90° MID TRIP NC NO C 90° Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 3 Alarm Switch available with .110 x .020 Q.C. & Solder Lug Terminals Only. www.carlingtech.com 65 B-Series Handle – Circuit & Terminal Diagrams TERMINAL DIMENSIONAL DETAIL & RATING .360[9.14] .392[9.96] .250[6.35] .375[9.53] .069[1.75] DIA TAB (Q.C.) .375[9.53] .250[6.35] #8-32 30 AMP #10-32 30 AMP M5 30 AMP M4 30 AMP +.002 -.000 #8-32 30 AMP #10-32 50 AMP .405[10.29] BACK CONNECT 30 AMP M6 STUD #8-32 30 AMP #10-32 50 AMP M5 50 AMP M4 30 AMP .051 DIA[Ø1.29] .110 [2.80] .087 [2.20] PUSH-IN STUD .110 [2.80] .126 [3.20] .287 [7.29] MATING HOLE TAB (Q.C.) .070 DIA [Ø1.80] SOLDER TYPE 1.313 [33.35] 2.230 [56.64] TYP .154 [3.91] DIA PUSH-IN STUD 50 AMP TABLE A TIGHTENING TORQUE SPECIFICATIONS THREAD SIZE #6-32 & M3 MOUNTING HARDWARE #8-32 & M4 THREAD TERMINAL SCREW #10-32 & M5 THREAD TERMINAL SCREW TORQUE 7-9 IN-LBS [0.8-1.0 NM] 12-15 IN-LBS [1.4-1.7 NM] 15-20 IN-LBS [1.7-2.3 NM] .520 [13.21] LINE LINE 2.000 [50.80] LOAD LOAD TABLE B TERMINAL DESCRIPTION TAB (Q.C.) MAIN SCREW TYPE SHUNT, RELAY TAB (Q.C.) & SCREW #8-32 DUAL COIL W/UPTURNED LUGS TAB (Q.C.) .110 x .020 AUX. SWITCH* SOLDER TYPE DEPTH BEHIND PANEL 2.090 [53.09] 2.122 [53.90] 2.612 [66.35] 2.644 [67.16] 2.537 [64.44] 2.348 [59.64] * AVAILABLE ON SERIES TRIP AND SWITCH ONLY CIRCUITS. .875 [22.23] REF BARRIER FOR UL-489 MULTI-POLE BREAKERS BARRIER FOR UL-RECOGNIZED MULTI-POLE BREAKERS SEE TABLE-B DEPTH BEHIND PANEL WHEN CALLED FOR ON MULTI-POLE UNITS, ONLY ONE AUX. SWITCH IS NORMALLY SUPPLIED, AS SHOWN IN MULTI-POLE IDENTIFICATION SCHEME. .393 [9.96] REF LINE (NETZ) ON I MID TRIP .100 [2.54] .750 [19.05] 50 AMP AUXILIARY SWITCH TERMINAL DETAIL [+.05] [-.00] .161 DIA [Ø 4.10] .392 [9.97] CENTERLINE OF PUSH-IN STUD CONTACT AREA .750[19.05] .437 [11.10] QC SOLDER LUG BUS 1.000 [25.40] .205 [5.21] .344[8.74] .093DIA [.76] UPTURN LUG 30 AMP .392[9.96] 1.560 [39.62] TYP 1.936[49.17] OFF O 1.350 [34.29] 30° 2 PLCS 1.560 [39.62] TYP LOAD (LAST) .032 [.81] TYP .220 [5.59] TYP PUSH-IN STUD M6 STUD SCREW TERMINAL WITH 30° BEND 1.250 [31.75] BACK CONNECT SCREW TERMINAL BACK CONNECT SCREW TERMINAL WITH RETAINER Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 66 www.carlingtech.com B-Series Handle – Front Panel Snap-In Mounting Style 5 Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ± 0.20 [.51] unless otherwise specified. www.carlingtech.com 67 B-Series Handle – Front Panel Snap-in Mounting Style 5 Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 Tolerance ±.020 [.51] unless otherwise specified. 68 www.carlingtech.com B-Series Handle – Front Panel Snap-In Mounting Style 7 Notes: 1 All dimensions are in inches [millimeters]. 2 Recommended panel thickness: .040 [1.02] to .100 [2.54]. 3 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 69 B-Series Rocker UL489 Listed – Ordering Scheme B F 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 24 5 Aux/Alarm Switch 6 Frequency & Delay 630 7 Current Rating 1 SERIES B 2 3 A 8 Terminal 9 Actuator Color 10 Mounting/ Barriers 8 TERMINAL5 16 2 3 4 5 6 7 8 9 2 ACTUATOR Two Color Visi-Rocker Indicate ON, vertical legend C D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend Single color J Vertical legend K Horizontal legend B C F G H J K N Y Push-On 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (Bus Type) Screw 10-32 w/upturned lugs Screw 10-32 (Bus Type) Screw 8-32 w/upturned lugs and 30° bend Screw 8-32 (Bus Type) and 30° bend Screw 10-32 w/upturned lugs and 30° bend Screw 10-32 (Bus Type) and 30° bend K G 11 Max. Appl. Rating 12 Agency Approval Screw M5 w/upturned lugs Screw M4 w/upturned lugs Screw M5 w/upturned lugs and 30° bend Screw M5 (Bus Type) and 30° bend Screw M5 (Bus Type) Screw M5 Back Connect Screw 10-32 Back Connect Screw M4 Back Connect Screw 8-32 Back Connect 9 ACTUATOR COLOR & LEGEND 3 POLES1,2 1 2 One 3 3 Two Actuator or Visi-Color7 White Black Red Green Blue Yellow Gray Orange Three 10 MOUNTING/BARRIERS 4 CIRCUIT B 0 1 2 3 w/o Aux Switch S.P.D.T., 0.093 Q.C. Term. S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug 6 FREQUENCY & DELAY 21 22 24 26 A B C D Series Trip (Current) 5 AUXILIARY/ALARM SWITCH4 AC Ultra Short AC Short AC Medium AC Long 7 8 9 S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. AMPERES 2100.100 2150.150 2200.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 MOUNTING STYLEBARRIERS9 Threaded Insert, 2 per pole 6-32 x 0.195 inches (multi-pole units only) yes ISO M3 x 5mm yes ROCKERGUARD BEZEL Threaded Insert, 2 per pole 6-32 X 0.225 inches (multi-pole units only) yes ISO M3 x 6.5mm yes 11 MAXIMUM APPLICATION RATING C8 120/240 VAC K 120 VAC 42 AC, Short,Hi-Inrush 44 AC, Medium, Hi-Inrush 46 AC, Long, Hi-Inrush 12 AGENCY APPROVAL G UL489 Listed 3 UL489 Listed, TUV Certified 7 CURRENT RATING (AMPERES) CODE Marking: Marking Color I-OON-OFF Dual7 Single Color Visi-Rocker AB 1Black White CD 2White n/a FG 3White Red HJ 4White Green KL 5White Blue MN 6Black Yellow PQ 7Black Gray RS 8Black Orange 2850.850 2900.900 2950.950 4101.000 5121.250 4151.500 517 1.750 4202.000 5222.250 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 4555.500 4606.000 4656.500 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 610 10.000 71010.500 611 11.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 Notes: 1 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. 2 All poles must be same polarity. 3 3 pole units available only when1 of 3 poles is neutral. 4 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 5 Screw Terminals are recommended on ratings greater than 20 amps. 6 Terminal Code 1 (Push-On) available up to 30 amps, but are not recommended over 20 amps. 7 Dual legend = ON-OFF/I-O 8 Voltage Rating available with 2 and 3-pole breakers only. 9 Barriers supplied on multi-pole units only. Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com 70 www.carlingtech.com B-Series Flat Rocker UL489 Listed – Ordering Scheme B 1 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 24 5 Aux/Alarm Switch 6 Frequency & Delay 17 2 3 4 5 6 7 8 9 2 ACTUATOR1 Two Color Visi-Rocker Indicate OFF, vertical legend 1 2 Indicate OFF, horizontal legend Single color 3 Vertical legend 4 Horizontal legend Push-To-Reset, Visi-Rocker Indicate OFF, 5 vertical legend 6 Indicate OFF, horizontal legend Push-To-Reset , Single color 7 Vertical legend 8 Horizontal legend 3 POLES2,3 2 One 34 Two Three Series Trip (Current) 5 AUXILIARY/ALARM SWITCH4 0 1 2 3 w/o Aux Switch S.P.D.T., 0.093 Q.C. Term. S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug 6 FREQUENCY & DELAY 21 22 24 26 AC Ultra Short AC Short AC Medium AC Long AMPERES 2100.100 2150.150 2200.200 2250.250 2300.300 2350.350 2400.400 2450.450 2500.500 2550.550 2600.600 2650.650 2700.700 2750.750 2800.800 10 Mounting/ Barriers Push-On 0.250 Tab (Q.C.) Screw 8-32 w/upturned lugs Screw 8-32 (Bus Type) Screw 10-32 w/upturned lugs Screw 10-32 (Bus Type) Screw 8-32 w/upturned lugs and 30° bend Screw 8-32 (Bus Type) and 30° bend Screw 10-32 w/upturned lugs and 30° bend Screw 10-32 (Bus Type) and 30° bend B C F G H J K N Y K G 11 Max. Appl. Rating 12 Agency Approval Screw M5 w/upturned lugs Screw M4 w/upturned lugs Screw M5 w/upturned lugs and 30° bend Screw M5 (Bus Type) and 30° bend Screw M5 (Bus Type) Screw M5 Back Connect Screw 10-32 Back Connect Screw M4 Back Connect Screw 8-32 Back Connect Actuator or Visi-Color8 White Black Red Green Blue Yellow Gray Orange Marking: Marking Color I-OON-OFF Dual8 Single Color Visi-Rocker AB 1Black White CD 2White n/a FG 3White Red HJ 4White Green KL 5White Blue MN 6Black Yellow PQ 7Black Gray RS 8Black Orange 10 MOUNTING/BARRIERS9 7 S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) 8 S.P.S.T., 0.187 Q.C. Term. 9 S.P.D.T., 0.187 Q.C. Term. 42 44 46 AC, Short,Hi-Inrush AC, Medium, Hi-Inrush AC, Long, Hi-Inrush A B E F C D STANDARD ROCKER BEZEL,Threaded Insert, 2 per pole BARRIERS12 FLAT ROCKER ACTUATOR 6-32 x 0.195 inches (multi-pole units only)yes ISO M3 x 5mm yes RECESSED OFF SIDE ROCKER ACTUATOR10 6-32 X 0.225 inches (multi-pole units only)yes ISO M3 x 6.5mm yes PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole 6-32 x 0.195 inches yes ISO M3 x 5mm yes 11 MAXIMUM APPLICATION RATING C11120/240VAC K120VAC 7 CURRENT RATING (AMPERES) CODE 9 Actuator Color 9 ACTUATOR COLOR & LEGEND 4 CIRCUIT B 2 3 A 8 Terminal 8 TERMINAL6 1 SERIES B 1 630 7 Current Rating 2850.850 2900.900 2950.950 4101.000 5121.250 4151.500 517 1.750 4202.000 5222.250 5272.750 4303.000 4353.500 4404.000 4454.500 4505.000 4555.500 4606.000 4656.500 4707.000 4757.500 4808.000 4858.500 4909.000 4959.500 610 10.000 71010.500 611 11.000 71111.500 61212.000 71212.500 61313.000 61414.000 61515.000 61616.000 61717.000 61818.000 62020.000 62222.000 62424.000 62525.000 63030.000 12 AGENCY APPROVAL G 3 UL489 Listed UL489 Listed, TUV Certified Notes: 1 Push-To-Reset actuators have OFF portion of rocker shrouded. 2 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. 3 All poles must be same polarity. 4 3 pole units available only when1 of 3 poles is neutral. 5 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 6 Screw Terminals are recommended on ratings greater than 20 amps. 7 Terminal Code 1 (Push-On) available up to 30 amps, but are not recommended over 20 amps. 8 Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O legend. 9 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes 5 & 6. 10 Recessed “off-side” available with actuator codes 1, 2, 3 & 4. Legends on rocker are available in ink stamping only. 11 Voltage rating available with 2 & 3-pole breakers only. 12 Barriers supplied on multi-pole units only. Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com www.carlingtech.com 71 B-Series Rocker UL489 Listed – Form & Fit Drawings Notes: 1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate “OFF” is opposite of indicate “ON”. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 All dimensions are in inches [millimeters]. 4 Tolerance ±.020 [.51] unless otherwise specified. 72 www.carlingtech.com B-Series Flat Rocker UL489 Listed – Form & Fit Drawings Notes: 1 All dimensions are in inches [millimeters]. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 73 B-Series PC Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 For pole orientation with horizontal legend, rotate front view clockwise 90°. 3 Tolerance ±.010 [.25] unless otherwise specified. 74 www.carlingtech.com C-Series Circuit Breaker C-Series Circuit Breaker The C-Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available in 1-6 poles, 0.02-100amps, UL Recognized up to 480VAC or 150VDC, UL489 Listed up to 240VAC or 125VDC, with choice of time delays, terminal options, actuator styles and colors. Product Highlights: The UL489 C-Series employs a unique arc chute design which allows for higher interrupting capacities of up to 10,000 amps. New thermoset glass filled polyester half shell construction provides for increased mechanical and electrical strength. The wiping contacts, mechanical linkage with two step actuation, clean contacts providing high, positive contact pressure and longer contact life Available with American Standard or Metric Threaded Stud terminals, or Saddle Clamp screw terminals. Optional mid-trip handle style actuator allows visual indication of electrical overload with or without alarm feature Available with new solid color rocker actuators and unique two-color Visi-rocker® actuators, which can be specified to indicate either the ON or TRIPPED/OFF mode Exclusive Rockerguard and Push-To-Reset bezel help prevent inadvertent actuation Agency Certifications: UL Recognized UL Standard 1077 | UL Standard 508 UL Standard 1500 UL Listed UL Standard 489 | UL Standard 489A CSA Accepted | CSA Certified TUV Certified | VDE Certified www.carlingtech.com 75 C-Series – General Specifications Electrical Tables Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary Protector 150 80-100 TC1, OLO, U3 150 101-175 TC, OLO, U3 Agency Code L Agency Code L Parallel Pole Notes for Table A: 1 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less rating and not to exceed 175 for 51 through 100 Amp rating *Manufacturer reserves the right to change product specification without prior notice. 76 www.carlingtech.com C-Series – General Specifications Electrical Tables Table B: Lists UL Recognized and CSA Accepted configurations and performance capabilities as a Manual Motor Controller. RELAY Notes for Table B: 1 UL recognized and CSA Accepted at 480V refers to 3 & 4 pole versions used in a 3Ø, wye connected circuit or 2-pole version connected with 2 poles breaking. 1Ø and backed up with series fusing as stated above in note 1. * Series, Shunt and Relay Trip - Voltage Coil Construction not current coils Table C: Lists UL Recognized, CSA Accepted , VDE and TUV Certified configurations and performance capabilities as a Component Supplementary Protector. Notes for Table C: 1 General Purpose ratings for UL/CSA only. 2 Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less rating and not to exceed 175 for 51 through 100 Amp rating. www.carlingtech.com 77 C-Series – General Specifications Electrical Tables Table D: Lists UL Listed (489), CSA Certified (C22.2 No. 5.1-M) configuration and performance capabilities as a Molded Case Circuit Breaker. C SERIES TABLE D : UL489 LISTED BRANCH CIRCUIT BREAKERS CIRCUIT CONFIGURATION SERIES DUAL COIL INTERRUPTING CAPACITY (AMPS) WITHOUT FULL LOAD BACKUP FUSE AMPS CURRENT RATING VOLTAGE MAX. RATING FREQUENCY PHASE 80 DC --- 0.10 - 100 CONSTRUCTION NOTES 50,000 1 Limited to 2 Poles Max from 71 - 100 Amps. 10,000 Limited to 2 Poles Max from 71 - 100 Amps. 125 DC --- 0.10 - 100 5,000 1 - 3 Poles 125 / 250 DC --- 0.10 - 50 5,000 1 or 2 Poles (2 Poles Required for 250 Volts) 120 50 / 60 1 0.10 - 50 10,000 1 - 3 Poles 51 - 70 5,000 1 - 3 Poles 120 / 240 50 / 60 1 0.10 - 50 5,000 2 or 3 Poles. 1 Pole of a 3 Pole Unit is Neutral 0.10 - 50 10000 1 2 or 3 Poles. 1 Pole of a 3 Pole Unit is Neutral 240 50 / 60 1 0.10 - 30 5,000 1Pole 240 50 / 60 1 0.10 - 20 5,000 2 Pole 277 50 / 60 1 0.10 - 20 10,000 1Pole 120 50 / 60 1 0.10 - 30 10,000 --- Notes from Table D: 1 Special catalog number required. Consult factory. Table E: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices, Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors. Table F: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (Guide DITT, File E189195), under UL489A. 78 www.carlingtech.com C-Series – General Specifications Mechanical Electrical Maximum Voltage AC, 480 WYE/277 VAC, 50/60 Hz (see Table A.) UL489: AC,240 VAC. (See Table D), 50/60 Hz, 125 VDC Current Rating Standard current coils: 0.100, 0.250, 0.500, 0.750, 1.00, 2.50, 5.00, 7.50, 10.0, 15.0, 25.0, 30.0, 35.0, 40.0, 50.0, 60.0, 70.0, 80.0, 90.0 and 100 amps. Other ratings available, see Ordering Scheme. Standard Voltage Coils DC - 6V, 12V; AC - 120V; other ratings available, see Ordering Scheme. Auxiliary Switch Rating SPDT; 10.1 amps-250VAC, DC Aux. Switch 1.0A, 65 VDC. 0.5A, 80VDC,1/4 HP, 125VAC,VDE & TUV 1.0 125 VAC. Insulation Resistance Minimum of 100 Megohms at 500 VDC. Dielectric Strength UL, CSA: 1960 V 50/60 Hz for one minute between all electrically isolated terminals. C-Series Circuit Breakers comply with the 8mm spacing and 3750V 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal based on Series Trip Circuit Breaker. RESISTANCE, IMPEDANCE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker ) 1000 CURRENT (AMPS) TOLERANCE (%) 0.10 - 5.0 15% 20.1 - 100.0 35% 100 5.1 - 20.0 10 O H M S 1 0.1 60 Hz 1/2 Cycle Inrush Pulse Tolerance Time Delay Curves 42, 44 & 46 (50 Amps Max.) Multiple of Rated Current Ir 25x 0.01 Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) 12x 0.001 0.01 1 0.1 10 100 t AMPERE RATING 4.165 Pulse Tolerance Curves CURRENT (AMPS) TOLERANCE (%) 0.100 - 5.0 15% 5.1 - 20.0 25% 60 Hz 1/2 Cycle - 100 Inrush Pulse20.1 Tolerance 35% 25x Ir 1 Multiple of Rated Current FIGURE Time Delay Curves 42, 44 & 46 (50 Amps Max.) Multiple of Rated Current Ir Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) 12x 8.33 16.67 50 Hz 1/2 Cycle Inrush Pulse Tolerance Time Delay Curves 42, 44 & 46 (50 Amps Max.) 22x Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) 10x t t 4.165 Ir Multiple of Rated Current 25% 8.33 5.0 16.67 Time Delay Curves 42, 44 & 46 (50 Amps Max.) Time Delay Curves 22, 24 (100 Amps Max.) 26 (70 Amps Max.) 10x 20.0 Time in Milliseconds 50 Hz 1/2 Cycle Inrush Pulse Tolerance 22x 10.0 Endurance 10,000 ON-OFF operations @ 6 per minute; with rated current & voltage. Trip Free All C-Series circuit breakers will trip on overload, even when actuator is forcibly held in the ON position. Trip Indication The operating actuator moves positively to the OFF position when an overload causes the breaker to trip. With mid-trip, handle moves to the mid position on electrical trip of the circuit breaker. With mid trip handle with alarm switch, handle moves to the mid position and the alarm switch actuates when the circuit breaker is electrically tripped. Physical Number of Poles Internal Circuit Config. Weight Standard Colors 1-6 poles ≤ 50A; 1-4 poles @ 5170A; 1-2 poles 71-100A. UL489 Handle: 1 pole ≤ 100A, 2 pole ≤ 50A; Rocker: 1 pole ≤ 100A. Series (with or without auxiliary switch, mid trip & mid trip with alarm switch) Shunt & Relay with current or voltage trip coils, Dual Coil, Switch Only (with or without aux. switch). UL489: Series (with or without auxiliary switch, mid-trip & midtrip with alarm switch). Approx.112 grams/pole ( 3.95 oz). Housing: Black Environmental Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: Shock Vibration Moisture Resistance Salt Spray Thermal Shock Operating Temperature Withstands 100 Gs, 6ms sawtooth while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultrashort curves tested @ 90% of rated current. Withstands 0.060” excursion from 10-55 Hz & 10 Gs 55-500 Hz, @ rated current per Method 204C, Test Cond. A. Instantaneous & ultrashort curves tested @ 90% of rated current. Method 106D, i.e., ten 24-hour cycles @ +25°C to +65°C, 80-98% RH. Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Method 107D, Condition A (five cycles @ -55°C to +25°C to +85°C to +25°C). -40°C to +85°C t 5.0 10.0 20.0 Time in Milliseconds www.carlingtech.com 79 C-Series Handle Parallel Pole UL489A Listed – Ordering Scheme C A 2 1 Series 2 Actuator P 0 4 Circuit 3 Poles 5 Aux/Alarm Switch D4 6 Frequency & Delay 820 7 Current Rating 3 6 A 2 ACTUATOR1 Handle, one per pole Mid-Trip Handle, one per pole Mid-Trip, one per pole & Alarm Switch 3 POLES3 2 3 Two Series Trip (parallel pole) w/o Aux Switch S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY D1 D2 M T 11 12 Max. App. Agency Rating Approval DC Ultra Short DC Short 1/4-20, threaded M6, threaded Plug-In Stud LEGEND ON-OFF White B Black D Red G Green J Blue L Yellow N Gray Q Orange S Three 5 AUXILIARY/ALARM SWITCH 0 2 3 4 10 Mounting 9 ACTUATOR COLOR 4 CIRCUIT P 9 Actuator Color 8 TERMINAL2 1 SERIES C A S T 3 2 1 8 Terminal 6 8 9 S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. D4 D6 DC Medium DC Long Dual Legend Color 1 Black 2 White 3 White 4 White 5 White 6 Black 7 Black 8 Black 10 MOUNTING/BARRIERS 1 2 MOUNTING STYLE Threaded Insert 6-32 x 0.195 inches ISO M3 x 5mm 11 MAXIMUM APPLICATION RATING M 80 DC 12 AGENCY APPROVAL 7 CURRENT RATING (AMPERES) CODE 811 812 912 813 AMPERES 110.000 120.000 125.000 130.000 814 815 816 817 140.000 150.000 160.000 170.000 917 818 819 820 170.000 180.000 190.000 200.000 9223 225.000 8253 250.000 T K 7 UL489A Listed (up to 250 amps) UL489A Listed, VDE Certified (up to 200 amps) UL489A Listed, TUV Certified (up to 250 amps) Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. 2 Terminal Code: 3 & 6: Supplied with bus bars connecting the Line and Load Terminals. A: Line and Load Terminals must be connected to a copper bus bar having a minimum cross section of 0.078 square inches. 3 Above 200 amps, 3 poles are required. Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com 80 www.carlingtech.com C-Series Handle UL489 Listed – Ordering Scheme C A 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 14 5 Aux/Alarm Switch 6 Frequency & Delay CODE 2 ACTUATOR1 Handle, one per pole Handle, one per multipole unit Mid-Trip Handle, one per pole Mid-Trip, one per pole & Alarm Switch 3 POLES2 1 One 2 3 Two Three 4 CIRCUIT B Series Trip (current) 5 AUXILIARY/ALARM SWITCH3 0 2 3 4 w/o Aux Switch S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY 11 12 14 16 21 22 24 1 2 1 8 Terminal 9 Actuator Color 10 Mounting/ Barriers K G 11 Max. App. Rating 12 Agency Approval 7 CURRENT RATING (AMPERES) 5 1 SERIES C A B S T 450 7 Current Rating DC Ultra Short DC Short DC Medium DC Long 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium 6 8 9 S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 26 424 444 464 524 544 564 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush Notes: 1 Actuator Code: A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units. B: Handle located, as viewed from front of breaker in left pole. 2 pole maximum. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. 2 Standard multipole units have all poles identical except when specifying auxiliary switch and/or mixed poles. 2 & 3 pole circuit breakers required for 120/240 VAC (Maximum application rating code C) applications, have all poles identical except when specifying auxiliary / alarm switch which is normally supplied in extreme right pole per figure B. Terminal barriers are required on all multipole breakers. Third pole is for 120/240 VAC applications requiring neutral disconnect. The 3rd pole has the same construction as poles 1 & 2. 3 On multi-pole breakers, one auxiliary. switch is supplied, mounted in the extreme right pole. VDE approval on auxiliary switch codes 2, 3 & 4 only. Auxiliary / Alarm Switch with Independent Circuit ie: separate from breaker circuit, only available with circuit breakers rated 50 amp maximum at 80 VDC, 125 VDC, and 120 VAC. Auxiliary / Alarm Switch with Dependent Circuit ie: same as circuit breaker, is supplied from factory with common terminal of auxiliary / alarm switch connected to line terminal on 120/240 and 240 VAC ratings. Circuit breakers rated 120 VAC 50 amp maximum can be supplied with Auxiliary/Alarm switch common terminal connected to breaker line terminal. Consult factory for special catalog number. 4 Available up to 50 amps maximum. 5 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum. 6 Terminal Codes 8, 9 & C are not VDE approved. 7 Terminal Code 1 available to 60 amps maximum. 8 Terminal Codes 2, 4, 5 & C available to 50 amps maximum. 9 Terminal Codes 3, 6 & 9 available to 100 amps maximum. 10 Terminal Code A available to 100 amps maximum. 11 VDE and TUV approvals require Dual (I-O, ON-OFF) markings on all handles. 12 Barriers supplied on multi-pole units only. AMPERES 210 0.100 2150.150 220 0.200 2250.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 2550.550 2600.600 265 0.650 2700.700 2750.750 2800.800 2850.850 290 0.900 295 0.950 410 1.000 512 1.250 415 1.500 5171.750 420 2.000 522 2.250 4252.500 5272.750 4303.000 4353.500 440 4.000 445 4.500 4505.000 4555.500 4606.000 4656.500 4707.000 475 7.500 4808.000 4858.500 4909.000 4959.500 61010.000 71010.500 61111.000 71111.500 61212.000 71212.500 61313.000 61414.000 615 15.000 61616.000 61717.000 8 TERMINAL6 1 7 2 8 3 9 4 8 5 8 6 9 8 9 9 A10 C Stud 10-32, threaded Screw 10-32 Screw 1/4-20, threaded Screw M5 x 0.8, threaded Screw M5 x 0.8 618 18.000 62020.000 62222.000 624 24.000 62525.000 63030.000 63535.000 64040.000 660 60.000 670 70.000 680 80.000 685 85.000 690 90.000 695 95.000 810 100.000 Screw M6, threaded 1/4” Clip Terminal 7/16” Clip Terminal Plug-In Stud 5/16” Clip Terminal 9 ACTUATOR COLOR & LEGEND11 Actuator Color White Black Red Green Blue Yellow Gray Orange ON-OFF Dual Legend Color B1 Black D2 White G3 White J 4 White L 5 White N 6 Black Q 7 Black S 8 Black 10 MOUNTING/BARRIERS 1 2 MOUNTING STYLE Threaded Insert 6-32 x 0.195 inches ISO M3 x 5mm BARRIERS12 yes yes 11 MAXIMUM APPLICATION RATING A B C D K M 65 DC 125 DC 120/240 AC2 240 AC 120 AC 80 DC 12 AGENCY APPROVAL11 A F G J w/o approvals UL489 Listed, CSA Certified & VDE Certified UL489 Listed & CSA Certified UL489 Listed, CSA Certified & TUV Certified Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com www.carlingtech.com 81 C-Series Rocker UL Listed – Ordering Scheme C C 3 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 14 6 Frequency & Delay 450 7 Current Rating CODE 2 ACTUATOR Single color Vertical legend J K Horizontal legend ROCKER STYLE DESCRIPTIONS INDICATE "ON" INDICATE "OFF" SINGLE COLOR CODE "F" CODE "J" CODE "C" INDICATE COLOR LOCATION HORIZONTAL STYLE VERTICAL STYLE LINE LINE CODE "D" 3 POLES1 One LINE 2 LINE CODE "G" LINE CODE "K" 3 15 2 6 37 4 6 5 6 Three 4 CIRCUIT Series Trip (current) 5 AUXILIARY/ALARM SWITCH2 0 2 3 4 w/o Aux Switch S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY 11 12 14 16 21 22 24 K G 10 Mounting/ Barriers DC Ultra Short DC Short DC Medium DC Long 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium 295 0.950 410 1.000 512 1.250 415 1.500 5171.750 420 2.000 522 2.250 4252.500 5272.750 430 3.000 4353.500 440 4.000 445 4.500 4505.000 4555.500 4606.000 4656.500 11 Max. App. Rating 4707.000 475 7.500 4808.000 4858.500 4909.000 4959.500 61010.000 71010.500 61111.000 71111.500 61212.000 71212.500 61313.000 61414.000 615 15.000 61616.000 61717.000 8 TERMINAL LINE Two AMPERES 210 0.100 2150.150 220 0.200 2250.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 2550.550 2600.600 265 0.650 2700.700 2750.750 2800.800 2850.850 290 0.900 1 Two Color Visi-Rocker C Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend B 9 Actuator Color 12 Agency Approval 7 CURRENT RATING (AMPERES) 4 1 SERIES C 1 1 2 A 8 Terminal 6 7 8 8 97,8 A7,8 C6,8 Stud 10-32, threaded Screw 8-32 w/saddle & washer clamps Stud 1/4-20, threaded Stud M5 x 0.8, threaded Screw M5 x 0.8 w/saddle & washer clamps 618 18.000 62020.000 62222.000 624 24.000 62525.000 63030.000 63535.000 64040.000 650 50.000 660 60.000 670 70.000 680 80.000 685 85.000 690 90.000 695 95.000 100 100.000 Stud M6, threaded 1/4” Clip Terminal 7/16” Clip Terminal Plug-In Stud 5/16” Clip Terminal 9 ACTUATOR COLOR & LEGEND11 6 8 9 S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 26 428 448 468 528 548 56 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush Notes: 1 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. 2 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 3 Available up to 50 amps maximum. 4 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum. 5 Terminal Code 1 available to 60 amps maximum. 6 Terminal Codes 2, 4, 5 & C available to 50 amps maximum. 7 Terminal Codes 3, 6, 9 & A available to 100 amps maximum. 8 Terminal Codes 8, 9 & C are not VDE approved. 9 Color shown is visi and legend with remainder of rocker black 10 Dual = ON-OFF/I-O legend on actuator. 11 VDE and TUV approval requires Dual (I-O, ON-OFF) markings on rocker. 12 Rockerguard available with all actuator codes. 13 Barriers supplied on multi-pole units only. 14 2 & 3 pole circuit breakers required for 120/240 AC rating. Actuator or Visi-Color Marking: Color: ON-OFF Dual10 White B 1 Black D 2 Red G 3 Green J 4 Blue L 5 Yellow N 6 Gray Q 7 Orange S 8 Marking Color: Single Color Rocker/Handle Black White White White White Black Black Black 10 MOUNTING/BARRIERS12 Standard Rocker Bezel A C B D Visi-Rocker White n/a Red Green Blue Yellow Gray Orange BARRIERS13 Threaded Insert, 2 per pole 6-32 X 0.195 inches ISO M3 x 5mm yes yes Threaded Insert, 2 per pole 6-32 x 0.195 inches ISO M3 x 5mm yes yes Rockerguard Bezel 11 MAXIMUM APPLICATION RATING A B C D K M 65 DC 125 DC 120/240 AC14 240 AC 120 AC 80 DC 12 AGENCY APPROVAL A F G J without approvals UL 489 Listed, CSA Certified, & VDE Certified UL 489 Listed & CSA Certified UL489 Listed, CSA Certified & TUV Certified Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com 82 www.carlingtech.com C-Series Flat Rocker UL Listed – Ordering Scheme C 1 2 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 14 6 Frequency & Delay 450 7 Current Rating CODE 1 3 POLES2 One 2 3 Two Three w/o Aux Switch S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) 6 FREQUENCY & DELAY 11 12 14 16 21 22 24 DC Ultra Short DC Short DC Medium DC Long 50/60Hz Ultra Short 50/60Hz Short 50/60Hz Medium 6 8 9 26 424 444 464 524 544 564 S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.187 Q.C. Term. S.P.D.T., 0.187 Q.C. Term. 50/60Hz Long 50/60Hz Short, Hi-Inrush 50/60Hz Medium, Hi-Inrush 50/60Hz Long, Hi-Inrush DC Short, Hi-Inrush DC Medium, Hi-Inrush DC Long, Hi-Inrush 295 0.950 410 1.000 512 1.250 415 1.500 5171.750 420 2.000 522 2.250 4252.500 5272.750 4303.000 4353.500 440 4.000 445 4.500 4505.000 4555.500 4606.000 4656.500 18 Stud 10-32, threaded .625 long Screw 8-32 w/saddle & washer 27 clamps 38 Stud 1/4-20, threaded .625 long Stud M5 x 0.8, threaded .625 47 long Series Trip (current) 5 AUXILIARY/ALARM SWITCH2 0 2 3 4 10 Mounting/ Barriers 8 TERMINAL 4 CIRCUIT B AMPERES 210 0.100 2150.150 220 0.200 2250.250 230 0.300 235 0.350 240 0.400 245 0.450 250 0.500 2550.550 2600.600 265 0.650 2700.700 2750.750 2800.800 2850.850 290 0.900 Two Color Visi-Rocker 1 Indicate OFF, vertical legend 2 Indicate OFF, horizontal legend Single color 3 Vertical legend 4 Horizontal legend Push-To-Reset, Visi-Rocker 5 Indicate OFF, vertical legend 6 Indicate OFF, horizontal legend Push-To-Reset , Single color 7 Vertical legend 8 Horizontal legend 1 9 Actuator Color K G 11 Max. App. Rating 12 Agency Approval 7 CURRENT RATING (AMPERES) 5 1 SERIES C 2 ACTUATOR 1 2 A 8 Terminal 4707.000 475 7.500 4808.000 4858.500 4909.000 4959.500 61010.000 71010.500 61111.000 71111.500 61212.000 71212.500 61313.000 61414.000 615 15.000 61616.000 61717.000 57 68 89 98,9 A8,9 C7,9 618 18.000 62020.000 62222.000 624 24.000 62525.000 63030.000 63535.000 64040.000 650 50.000 660 60.000 670 70.000 680 80.000 685 85.000 690 90.000 695 95.000 100 100.000 Screw M5 x 0.8 w/saddle & washer clamps Stud M6, threaded 17mm long 1/4” Clip Terminal 7/16” Clip Terminal Plug-In Stud 5/16” Clip Terminal 9 ACTUATOR COLOR & LEGEND12 Actuator or Visi-Color Marking: Color: ON-OFF Dual11 White B 1 Black D 2 Red G 3 Green J 4 Blue L 5 Yellow N 6 Gray Q 7 Orange S 8 1 Notes: 2 Push-to-reset actuators have OFF portion of rocker shrouded. 3 Multi-pole breakers have all breakers identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. 4 On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. 5 Available up to 50 amps maximum. 6 Current ratings 71 - 100 with VDE approvals are available up to two poles maximum. 7 Terminal Code 1 available to 60 amps maximum. 8 Terminal Codes 2, 4, 5 & C available to 50 amps maximum. 9 Terminal Codes 3, 6, 9 & A available to 100 amps maximum. 10 Terminal Codes 8, 9 & C are not VDE approved. 11 Color shown is visi and legend with remainder of rocker black 12 Dual = ON-OFF/I-O legend on actuator. 13 VDE and TUV approval requires Dual (I-O, ON-OFF) markings on rocker. 14 Legend on push-to-reset bezel/shroud is white when single color rocker is ordered. Legend on push-to-reset bezel/shroud matches visi-color of rocker with actuator codes 15 5 & 6. 16 Recessed “OFF-SIDE” available with actuator codes 1, 2, 3, & 4. Legends on rocker are available in ink stamping only. 17 Barriers supplied on multi-pole units only. 18 2 & 3 pole circuit breakers required for 120/240 AC rating. 10 MOUNTING/BARRIERS12 A C E F B D STANDARD ROCKER BEZEL Threaded Insert, 2 per pole 6-32 X 0.195 inches ISO M3 x 5mm RECESSED OFF ROCKER14 Threaded Insert, 2 per pole 6-32 x 0.195 inches ISO M3 x 5mm PUSH-TO-RESET BEZEL13 Threaded Insert, 2 per pole 6-32 x 0.195 inches ISO M3 x 5mm Marking Color: Single Color Rocker/Handle Black White White White White Black Black Black Visi-Rocker White n/a Red Green Blue Yellow Gray Orange BARRIERS15 yes yes yes yes yes yes 11 MAXIMUM APPLICATION RATING A B C D K M 65 DC 125 DC 120/240 AC16 240 AC 120 AC 80 DC 12 AGENCY APPROVAL A G J without approvals UL 489 Listed & CSA Certified UL489 Listed, CSA Certified & TUV Certified Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com www.carlingtech.com 83 C-Series Handle – Circuit & Terminal Diagrams .960 [24.38] .311 DIA [Ø7.90] .558 [14.17] Notes: 1 2 3 84 All dimensions are in inches [millimeters]. Tolerance ±.020 [.51] unless otherwise specified. Available on Series Trip and Switch Only Circuits when called for on multi-pole units. Only one aux. switch is normally supplied, as viewed in mulit-pole identification scheme. www.carlingtech.com C-Series Handle – Circuit & Terminal Diagrams Notes: 1 2 3 4 All dimensions are in inches [millimeters]. Tolerance ±.020 [.51] unless otherwise specified. Schematic shown represents current trip circuits. Available only as special catalog number. www.carlingtech.com 85 C-Series Handle – Form & Fit Drawings Notes: 1 2 86 All dimensions are in inches [millimeters]. Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com C-Series Handleguard – Form & Fit Drawings Notes: 1 2 All dimensions are in inches [millimeters]. Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 87 C-Series Parallel Pole – Form & Fit Drawings Notes: 1 2 88 All dimensions are in inches [millimeters]. Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com C-Series Rocker – Circuit & Terminal Diagrams Notes: 1 2 3 All dimensions are in inches [millimeters]. Tolerance ±.020 [.51] unless otherwise specified. Schematic shown represents current trip circuit. www.carlingtech.com 89 C-Series Rocker – Form & Fit Drawings Notes: 1 2 3 4 90 Dimensions apply to all variations shown. Notice that circuit breaker line and load terminal orientation on indicate OFF is opposite of indicate ON. For pole orientation with horizontal legend, rotate front view clockwise 90°. All dimensions are in inches [millimeters]. Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com C-Series Flat Rocker – Form & Fit Drawings Notes: 1 2 3 For pole orientation with horizontal legend, rotate front view clockwise 90°. All dimensions are in inches [millimeters]. Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 91 CX-Series Circuit Breaker CX-Series Circuit Breaker The CX-Series circuit breaker features a unique and innovative arc-quenching configuration that allows the breaker to safely handle high amperage and high DC voltage applications in a compact package. By using a patent pending magnetic flux boosting terminal configuration, a strong magnetic field is created thus motivating the arc into an enhanced arc chamber improving the breaker’s overall performance and reliability. The permanent magnets located at the entrance of the arc chamber combined with the upper and lower arc runner increase the magnetic blow out force and aid in motivating the arc off of the contacts and into the arc chamber. An enhanced arc chamber features arc splitter retainers with integrated pressurizing walls, which facilitates heat transfer from the arc thereby providing additional cooling and quick transition into the magnetically induced splitter plates. In turn, the twelve (12) splitter plates attract, segment and cool the arc for full extinction. Combined, these innovative features make the CX-Series breaker the best in class, providing stable performance even in the most demanding applications and is ideally suitable for integration into Information Technologies’ power distribution equipment utilizing high DC voltage input. Additional Features: TUV Certified IEC/EN 60947-2 Temperature stable hydraulic/magnetic overcurrent sensing technology. Optional relay trip circuit permitting remote operator system shut down. Choice of 6-32 or M3 mounting inserts providing secure panel mount installation. 92 www.carlingtech.com CX-Series Circuit Breaker - General Specifications CX-Series Circuit Breaker DESIGN FEATURES MAGNETS UPPER ARC RUNNER Aids in motivating arc off of movable contact and into arc chamber (12) ARC DEIONIZING SPLITTER PLATES HYDRAULIC/MAGNETIC SENSING COIL PATENT PENDING MAGNETIC FLUX BOOSTING TERMINAL CONFIGURATION Design enhances motivation of arc into arc chamber www.carlingtech.com ARC SPLITTER RETAINER w/ integrated pressurizing walls LOWER ARC RUNNER Aids in motivating arc off of stationary contact and into arc chamber LARGE ARC GAP To generate high arc voltages 93 CX-Series Circuit Breaker - General Specifications Electrical Tables Table A: Lists UL Listed (UL489) configuration and performance capabilities as a Molded Case Circuit Breaker CX SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS CIRCUIT CONFIGURATION VOLTAGE MAX. RATING FREQUENCY SERIES MAX CURRENT INTERRUPTING NUMBER RATING AMPS CAPACITY (AMPS) OF POLES 250 D.C. 15 5,000 1 250 / 500 D.C. 15 10,000 2 Table B: Lists UL Recognized configurations and performance capabilities as a Component Supplementary Protector CX SERIES TABLE B : UL1077 COMPONENT SUPPLEMENTARY PROTECTOR VOLTAGE CIRCUIT CONFIGURATION MAX. RATING SERIES SWITCH ONLY1 MAX INTERRUPTING CURRENT CAPACITY (AMPS) FREQUENCY RATING AMPS NUMBER APPLICATION OF POLES CODE 300 D.C. 1 - 75 5,000 1 TC1, OL0, U3 300 D.C. 76 - 125 3,000 1 TC1, OL0, U3 440 D.C. 1 -30 10,000 2 TC1, OL0, U3 440 D.C. 31 - 63 5,000 2 TC1, OL0, U3 600 D.C. 1 - 75 3,000 2 TC1, OL0, U3 600 D.C. 76 - 100 5,000 2 TC1, OL0, U3 600 D.C. 1 - 100 3,000 2 or 3 --- Notes: 1 Requires inclusion of a relay trip voltage coil Table C: Lists UL Listed (UL489B) configuration and performance capabilities as a Molded Case Switch CX SERIES TABLE C : UL489B LISTED PHOTOVATIC MOLDED CASE SWITCH VOLTAGE CIRCUIT CURRENT RATING INTERRUPTING CONFIGURATION MAX RATING FREQUENCY POLES (AMPS) RATING (AMPS) CONSTRUCTION NOTES 600 DC 21 50 - 100 600 May have a third pole that is a voltage trip pole 600 DC 42 110 - 175 600 May have a fifth pole that is a voltage trip pole SERIES Notes: 1 Two poles in series. 2 Two poles in series in parallel with 2 poles in series. Table D: TUV Certified Configuration to IEC / EN 60947-2. Low Voltage Switchgear and Controlgear - Circuit Breakers CX-SERIES TABLE D : TUV IEC/EN 60947-2 LOW VOLTAGE SWITCH GEAR & CONTROL GEAR / CIRCUIT BREAKER CIRCUIT CONFIGURATION SERIES VOLTAGE MAX. RATING FREQUENCY POLES 440 DC 2 CURRENT RATING (AMPS) 1-63 INTERRUPTING CAPACITY ICS / ICU (AMPS) 4,000 *Manufacturer reserves the right to change product specification without prior notice. 94 www.carlingtech.com CX-Series Circuit Breaker - General Specifications Electrical Mechanical Maximum Voltage Overload 600 VDC 50 operations at 600% of rated current for UL489, and at 150% of rated current for UL1077. RESISTANCEIMPEDANCE PER POLE VALUES RESISTANCE, VALUES fromfrom LineLine to Load Terminals to Load Terminals (ValuesBased Based on on Series Trip (Values Trip Circuit CircuitBreaker) Breaker) 1000 100 10 O H M S Current (amps) 0.1 -5.0 Tolerance (%) 15% 5.1-20.0 25% 20.1-125 35% Environmental 1 0.1 0.01 0.001 0.01 Endurance Max 10,000 ON-OFF operations @ 6 per minute; 6000 with rated current & voltage, and 4,000 cycles mechanical. Trip Free Trips on overload even when actuator is forcibly held in the “On” position. Trip Indication The operating handle moves positively to the “Off” position when an overload causes the breaker to trip. 0.1 1 10 AMPERE RATING 100-125 100 Physical Number of Poles Termination Termination Barrier Mounting Actuator Internal Circuit Config. Materials Weight Standard Color 1- 2 poles, + Auxiliary Switch Pole. 10-32 or M5 Screw Terminals 1/4-20 or M6 Threaded Stud Terminals Standard with multi-pole constructions Threaded insert: #6-32 UNC-2B, or M3X0.5-6H B ISO (2 per pole) Handle, 1 per pole. Series Trip Housing - Glass filled Polyester Handle - Glass filled Polyester Line/Load Terminals - Copper Alloy. ~150 Grams (~5.3 Ounces). ~150 Grams (~5.3 Ounces). Housing - Gray. Handle - White, Black, Red, Green, Blue, Yellow, Gray, www.carlingtech.com Shock Vibration Moisture Resistance Salt Spray Thermal Shock Operating Temperature Withstands 100 Gs, 6ms saw tooth while carrying rated current per MILPRF-55629 and MIL-STD- 202G, Method 213G, Test Condition “I”. Instantaneous and ultra short curves tested at 90% of rated current Withstands 0.060” excursion from 10-55 Hz & 10 Gs 55-500 Hz, at rated current per MIL-PRF-55629 and MILSTD-202G, Method 240D, Test Cond. A. Instantaneous & ultrashort curves tested at 90% of rated current. MIL-PRF-55629 and MIL-STD- 202G, Method 106G, i.e., Ten 24- hour cycles at +25°C to +65°C, 80- 98% RH. Method 101, Condition A (90-95% RH at 5% NaCl Solution, 96 hrs). MIL-PRF-55629 and MIL-STD- 202G, Method 107G, Condition A (5-cycles at -55°C to +25°C to +85°C to +25°C). -40°C to +85°C. 95 CX-Series Circuit Breaker UL489 – Ordering Scheme C X 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 14 6 Frequency & Delay 420 7 Current Rating 2 ACTUATOR X Handle, one per pole 3 POLES 1 One 2 Two 5 AUXILIARY/ALARM SWITCH 0 w/o Aux Switch 10 MOUNTING INSERTS A 6-32 Thread 6 FREQUENCY & DELAY 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 11 MAX. APPLICATION RATING 12 250VDC 0.200 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 280 285 290 295 410 512 415 517 420 522 425 527 0.800 0.850 0.900 0.950 1.000 1.250 1.500 1.750 2.000 2.250 2.500 2.750 10 Mounting Inserts 5 6 B 131 12 G 11 Rating 12 Agency Approval Screw Terminal, M5 Stud, M6 Dual Legend Color 1Black 2White 3White 4White 5White 6Black 7Black 8Black M3 Thread 250 / 500VDC 12 AGENCY APPROVAL Without approvals A UL 489 Listed G 76 CURRENT RATING (AMPERES) AMPERES 9 Actuator Color & Legend 9 ACTUATOR COLOR & LEGEND Actuator Color I-O ON-OFF White AB Black CD Red FG Green HJ Blue KL Yellow MN Gray PQ Orange RS 4 CIRCUIT B Series Trip (current) CODE 8 Terminal 8 TERMINAL 2 Screw Terminal, 10-32 3 Stud, 1/4-20 1 SERIES C 220 225 230 235 240 245 250 255 260 265 270 275 2 2 A 430 435 440 445 450 455 460 465 470 475 480 485 3.000 3.500 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 490 495 610 710 611 711 612 712 613 614 615 9.000 9.500 10.000 10.500 11.000 11.500 12.000 12.500 13.000 14.000 15.000 Notes: 1 250/500 rating requires two pole breaker Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com 96 www.carlingtech.com CX-Series Circuit Breaker UL1077 – Ordering Scheme C X 1 1 Series 2 Actuator B 0 4 Circuit 3 Poles 5 Aux/Alarm Switch 14 6 Frequency & Delay 2 ACTUATOR X Handle, one per pole 4 CIRCUIT A1 Switch Only (no coil) B Series Trip (current) G1 Relay Trip (voltage) 7 CURRENT RATING (AMPERES) 6 420 522 425 527 430 435 440 445 450 455 460 465 470 475 480 485 490 495 610 710 10 C 10 Mounting Inserts 11 Rating 12 Agency Approval Dual Legend Color 1Black 2White 3White 4White 5White 6Black 7Black 8Black 11 MAX. APPLICATION RATING 10 300VDC 114 440 VDC without factory installed terminal bus 144 440VDC with factory installed terminal bus 065 600VDC 6 FREQUENCY & DELAY 03 DC 50/60Hz, Switch Only 10 DC Instantaneous 11 DC Ultra Short 12 DC Short 14 DC Medium 16 DC Long 0.200 0.250 0.300 0.350 0.400 0.450 0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 1.250 1.500 1.750 9 Actuator Color & Legend 10 MOUNTING INSERTS A 6-32 Thread w/o terminal bus B M3 Thread w/o terminal bus 5 AUXILIARY SWITCH 0 w/o Aux Switch3 AMPERES 6 2 B 8 Terminal 9 ACTUATOR COLOR & LEGEND Actuator Color I-O ON-OFF White AB Black CD Red FG Green HJ Blue KL Yellow MN Gray PQ Orange RS 3 POLES 1 One 2 Two 3 Three 220 225 230 235 240 245 250 255 260 265 270 275 280 285 290 295 410 512 415 517 7 Current Rating 8 TERMINAL 2 Screw Terminal, 10-32 3 Stud, 1/4-20 5 Screw Terminal, M5 6 Stud, M6 1 SERIES C CODE 660 2.000 2.250 2.500 2.750 3.000 3.500 4.000 4.500 5.000 5.500 6.000 6.500 7.000 7.500 8.000 8.500 9.000 9.500 10.000 10.500 611 711 612 712 613 614 615 616 617 618 620 622 624 625 630 635 640 650 660 665 11.000 11.500 12.000 12.500 13.000 14.000 15.000 16.000 17.000 18.000 20.000 22.000 24.000 25.000 30.000 35.000 40.000 50.000 60.000 65.000 670 675 680 685 690 695 810 911 912 70.000 75.000 80.000 85.000 90.000 95.000 100.000 115.000 125.000 12 AGENCY APPROVAL A Without approvals C UL 1077 Recognized W UL 1077 Recognized & TUV Certified IEC/ EN 60947-29 Notes: 1 Only available when tied to a protected pole Requires special P/N consult factory for details 2 Voltage trip circuit coil not rated for continuous duty - use instantaneous delay code 10 3 Contacts Rated for 20A @ 80 VDC 4 440VDC Rating available in two different wiring configurations, see next page for more details 5 600 VDC only available with factory installed terminal bus (see next page for more details) 6 Single pole units available up to 125A, multi pole units limited to 100A Max. (see next page for more details) 7 3 Pole units must include one Auxiliary switch pole (circuit code A or G) - Requires Special Part Number. (see next page for more details) 8 Screw Terminals are limited to 50A max. 9 Agency approval code W only available with 440 VDC rating & circuit code B. Additional configurations available. See Hydraulic/Magnetic Circuit Protection Catalog or visit www.carlingtech.com www.carlingtech.com 97 CX-Series Circuit Breaker UL1077 – Form & Fit Drawings 98 www.carlingtech.com CX-Series Circuit Breaker UL489 – Form & Fit Drawings 0.265 [6.73] 0.380 [9.65] 0.380 [9.65] 1.052 [26.72] 0.755 [19.18] MAXIMUM 0.579 [14.72] 0.265 [6.73] 0.755 [19.18] MAXIMUM 0.579 [14.72] 1.719 [43.66] +0.050 3.094 –0.020 78.59 +1.27 –0.50 2.062+0.020 [52.37+0.50] +0.050 3.094 –0.020 78.59 +1.27 –0.50 2.062+0.020 [52.37+0.50] 1.052 [26.72] 0.380 [9.65] 2.259+0.020 [57.38+0.50] 0.502 [12.75] 2.259+0.020 [57.38+0.50] 0.502 [12.75] 1.719 [43.66] 30.0º 0.755 [19.18] MAXIMUM 0.124 [3.16] 30.0º 0.124 [3.16] 0.265 [6.73] 0.626+0.020 [15.90+0.50] 2.264+0.020 [57.51+0.50] 1.719 [43.66] 1.017 [25.82] 1.515 [38.48] MAXIMUM 0.502 [12.75] 1.843+0.020 [46.81+0.50] 0.579 [14.72] 2.264+0.020 +0.050 [57.51+0.50] 3.094 –0.020 1.017 [25.82] 78.59 +1.27 –0.50 2.062+0.020 [52.37+0.50] 30.0º 1.052 [26.72] 1.843+0.020 [46.81+0.50] 2.259+0.020 [57.38+0.50] 0.626+0.020 [15.90+0.50] 0.124 [3.16] 3.672 [93.268] SHOWN WITH STUD TERMINAL CONFIGURATION 1.843+0.020 [46.81+0.50] SHOWN WITH STUD TERMINAL CONFIGURATION 0.626+0.020 [15.90+0.50] 2.264+0.020 [57.51+0.50] 2.259 [57.38] 1.515 [38.48] MAXIMUM 3.672 [93.268] 2.259 [57.38] 1.515 [38.48] MAXIMUM 0.744 [18.90] 0.744 [18.90] 2.736 [69.49] (WITH SCREW TERMINAL) 2.946 [74.83] 2.736 (WITH STUD TERMINAL) [69.49] 3.276 (WITH SCREW TERMINAL) [83.21] 2.946 (UNFOLDED [74.83] BARRIER) SHOWN WITH STUD TERMINAL CONFIGURATION 1.017 [25.82] 3.672 [93.268] 2.259 [57.38] SHOWN WITH SCREW TERMINAL CONFIGURATION 1.520 SHOWN WITH SCREW [38.61] TERMINAL CONFIGURATION 0.760 0.078 TYP [1.98] [19.30] (WITH STUD TERMINAL) 0.760 3.276 1.062 [19.30] [83.21] [26.97] TOLERANCES +.005[.12] (UNFOLDED BARRIER) 2.7362.062 [52.37] [69.49] 0.744 1.062 [18.90] (WITH SCREW TERMINAL) [26.97] TOLERANCES +.005[.12]2.946 0.625 [74.83] 2.062[15.88] (WITH STUD TERMINAL) [52.37] 3.276 [83.21] 0.625 (UNFOLDED BARRIER) [15.88] 1.520 [38.61] 0.078 TYP [1.98] SHOWN WITH SCREW TERMINAL CONFIGURATION CX1 CX2 CX1 CX2 0.750 TYP [19.05] 1.520 [38.61] 0.760 [19.30] 0.750 TYP [19.05] 0.078 TYP [1.98] 1.062 [26.97] TOLERANCES +.005[.12] 2.062 [52.37] 0.625 [15.88] www.carlingtech.com CX1 CX2 0.750 TYP [19.05] 99 F-Series Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its time-proven hydraulic/ magnetic design, the F-Series load sensing mechanism is insensitive to changes in ambient or enclosure temperature, providing a consistent trip point over temperatures ranging from -40°C to +85°C. Additionally, the F-Series circuit breakers come with a choice of overload time delays, making them ideal for critical applications having inductive loads. Further, the F-Series breakers are available up to 700A and an optional 25 millivolt metering shunt construction provides a safe method for monitoring current flowing through the breaker by simply connecting a meter with light gauge wire to the appropriate terminals located on the shunt housing at the rear of the breaker. Applications can be customized by measuring and displaying percentage of current, watts or safe/danger zones. Features: AC ratings to UL 489 DC voltage ratings up to 700A with metering shunt section Consistent trip point over temperatures ranging from -40°C to +85°C Optional 25 millivolt metering shunt construction 100 www.carlingtech.com F-Series Circuit Breaker - General Specifications Electrical Mechanical Maximum Voltage 125VDC Current Ratings Standard current coils: 100, 125, 150, 175, 225, 250 amps. 300, 350, 400, 500, 600, 700 amps available as parallel pole construction. Auxiliary Switch Rating SPDT; 10.1 Amps @ 250VAC, 1.0 Amps @ 65VDC, 0.5 Amps @ 80VDC 0.1 Amps @ 125VAC (with gold contacts). Insulation Resistance Minimum: 100 Megohms at 500 VDC Dielectric Strength 1960 VAC, 50/60 Hz for one minute between all electrically isolated terminals, except 2500 VAC for one minute between alarm/aux. switch and main terminals with contacts in open and closed position. F-Series circuit breakers comply with the 8mm spacing & 3750VAC 50/60 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxilary circuits per Publications EN 60950 and VDE 0805. Resistance, Impedance Values from Line to Load Terminal - based on Series Trip Circuit Breaker. Endurance 4000 ON-OFF operations with rated Current & Voltage & 4000 operations with no load (8000 operations total) @ 5 per minute. Parallel Pole construction: 1000 operations with rated Current and Voltage @ 5 per minute. Trip Free All F-Series Circuit Breakers will trip on overload, even when the actuator is forcibly held in the ON position. Trip Indication The operating actuator moves positively to the OFF position when an overload causes the circuit breaker to trip. RESISTANCE PER POLE VALUES from Line to Load Terminals (Values Based on Series Trip Circuit Breaker) Physical Number of Poles 1 - 3 Poles Note: Ratings over 250 Amps only available with parallel pole. Internal Circuit Config. Series (with or without auxiliary switch), Switch Only (with or without auxiliary switch). Available Accessories Factory installed: DC Current Metering Shunt (25 mV @lr) Weight Varies depending on construction. Consult factory. Standard Colors Housing - Black; Actuator- Black or White with contrasting ON-OFF legend. Environmental Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows: Shock Withstands 100 Gs, 6ms, sawtooth while carrying rated current per Method 213, Test Condition “I”. Instantaneous and ultra-short curves tested @ 90% of rated current. Vibration Withstands 0.060” excursion from 10-55 Hz, and 10 Gs 55-500 Hz, at rated current per Method 204C, Test Condition A. Instantaneous and ultrashort curves tested at 90% of rated current. Moisture Resistance Method 106D; ten 24-hour cycles @ + 25°C to +65°C, 80-98% RH.56 days @ +85°C, 85% RH. Salt Spray Method 101, Condition A (90-95% RH @ 5% NaCl Solution, 96 hrs). Thermal Shock Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C). Operating Temperature -40° C to +85° C *Manufacturer reserves the right to change product specification without prior notice. www.carlingtech.com 101 F-Series Circuit Breaker - General Specifications Table A: Lists ULTables Listed (489)and CSA Certified (C22.2 N0. 5.1-M) configurations and performance Electrical capabilities asUL a Molded Case Circuit Table A: Lists Listed (489)and CSA Brekaer Certified (C22.2 N0. 5.1-M) configurations and performance capabilities as a Molded Case Circuit Breaker F SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS VOLTAGE CIRCUIT CONFIGURATION MAX RATING FREQUENCY PHASE 125 SERIES CURRENT RATING INTERRUPTING CAPACITY (AMPS) FULL LOAD AMPS UL / CSA 1 - 3 POLES TUV 2 1 or 2 POLES DC --- 50 - 250 50,000 25,000 1 50 / 60 50 / 60 1 1 100 - 250 100 - 250 10,000 10,000 ----- 208Y / 120 50 / 60 3 100 - 250 10,000 --- 120 / 240 277 Notes: NOTES: 1 120/240V rating available in 2 or 3 poles. In a 3 pole construction the center pole is Neutral. 1. rating in 2ACorratings. 3 poles. In a 3 pole construction the center pole is Neutral. 2 120/240V TUV constructions are available not available with 2. TUV constructions are not available with AC ratings. Table B: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment (Guide DITT, File E189195), under UL489A Agency Certifications UL Listed UL 489 UL 489A 102 Circuit Breakers , Molded Case (Guide DIVQ, File E129899) Complies with the requirements of the CSA Standard for Molded Case Circuit Breakers, CANCSA- C22.2 No. 5.1 –M Circuit Breakers for Use in Communications Equipment (Guide DITT, File E189195) TUV Certified IEC 60947-2 Low Voltage Switch gear and Control Gear under TUV License No. R72031058 www.carlingtech.com F-Series Handle – Ordering Scheme F A 2 1 Series 2 Actuator B 0 4 Circuit 3 Poles 14 5 Aux/Alarm Switch 6 Frequency & Delay 1 SERIES F Actuator Color White Black Handle, one per pole Mid-Trip Handle, one per pole Mid-Trip Handle, one per pole & Alarm Switch 3 POLES 1 2 One Front Mounting Inserts A 10-32 B ISO M5 3 Switch Only (no coil) Series Trip (current) Series Trip (voltage) w/o Aux Switch S.P.D.T., 0.110 Q.C. Term. S.P.D.T., 0.139 Solder Lug S.P.D.T., 0.110 Q.C. Term. (Gold Contacts) S.P.S.T., 0.093 Q.C. Term. (Gold Contacts) S.P.S.T., 0.139 Solder Lug S.P.S.T., 0.110 Q.C. Term. (Gold Contacts) DC 50/60Hz, Switch Only DC Instantaneous DC Ultra Short DC Short 8 S.P.S.T., 0.187 Q.C. Terminals 9 S.P.D.T., 0.187 Q.C. Terminals. A6 S.P.S.T., 0.093 Round QC Terminals. B6 S.P.D.T., 0.093 Round Q.C. Terminals. 14 16 22 24 26 DC Medium DC Long AC Short AC Medium AC Long 7 CURRENT RATING (AMPERES) CODE 810 912 815 917 AMPERES 100.00 125.00 150.00 175.00 820 200.00 922225.00 825 250.00 8308 300.00 8358350.00 8408 400.00 8458 450.00 8508 500.00 8608 600.00 8708 700.00 OR VOLTAGE COIL (VOLTS, MIN. TRIP RATING)7 CODE AMPERES A06 6 DC, 5 DC A12 12 DC, 10 DC A18 18 DC, 15 DC B G 11 Max. App. Rating 12 Agency Approval Dual Marking Color 1Black 2White Back Mounting Inserts 10-32 screw clearance holes 10-32 screw clearance holes Three Parallel Pole Construction: M3,4 Series Trip (Current) with Metering Shunt N3,4 Switch Only with Metering Shunt Series Trip (Current) P3 Switch Only Q3 6 FREQUENCY & DELAY 03 107 11 12 10 Mounting I-O ON-OFF AB CD 10 MOUNTING Two 5 AUXILIARY/ALARM SWITCH5 0 2 3 4 5 6 7 9 Actuator Color 11 MAXIMUM APPLICATION RATING 4 CIRCUIT A1 B C2 1 2 A 8 Terminal 9 ACTUATOR COLOR & LEGEND12,13 2 ACTUATOR A S T 820 7 Current Rating A24 24 DC, 20 DC A32 32 DC, 25 DC A48 48 DC, 40 DC 8 TERMINAL Back Connected (Front Mounted Only) 19 3/8-16 Stud 214 3/8-16 Screw, Line & Load 14 5 3/8-16 Short Stud Front Connected (Back Mounted Only)11 3 Box Wire Connector, Line & Load 414 3/8-16 Screw, Line & Load www.carlingtech.com A65 65 DC, 55 DC B25 125 DC, 100 DC J06 6 AC, 5 AC VOLTAGECURRENT B 125 VDC 700A C15 120/240250A F 277 VAC 250A 716 120/208 VAC 250A 12 AGENCY APPROVAL A G J T No approvals UL 489 Listed & CUL Certified UL 489 Listed, CUL Certified & TUV Certified UL489A (Telecom) Listed Notes: 1 For 100 to 250 amps, select Current Code 825. For 300-400 amps, select Current Code 840. For 450-700 amps, select Current Code 870. 2 Available with Frequency and Delay code 10 or 20 only, and are not rated for continuous duty. Delay 10 and 20 are only available with voltage coils. 3 3 Codes M, N, P & Q (Parallel Poles) are supplied with factory installed Bus Bar on Line and Load. 4 4 Metering terminals are female pin type, ref. Molex part number 02-09-1101, model 1189-T. 5 Auxiliary Switch breakers are only available with Series Trip and Switch Only circuits. On multi-pole breakers, one Auxiliary Switch is supplied, mounted in the extreme right pole per figure A. Back-Mounted breakers require special mounting provisions when an Auxiliary Switch is specified. 6 Available with parallel pole construction (circuit codes P and Q, and breakers with circuit codes M and N). 7 Frequency and delay code 10 is only available with Voltage Coils. Voltage Coils are not rated for continuous duty. 8 Ratings over 250 amps are only available with Agency Approval code T (UL489A) and are Parallel Pole configuration (circuit codes M, N, P and Q.) 300-450 amp ratings are available on two pole breakers. 500-700 amp ratings are available on three pole breakers. 9 Per UL requirement, an “Anti-Flash Over Barrier” is supplied between poles on multipole breakers with 3/8 - 16 stud terminals (Terminal Code 1) 10 Front connected breakers can also be front mounted by utilizing the supplied front panel mounting inserts.Terminal connections must be made before mounting. 11 Box Wire connector will accept #6 through 250 MCM copper wire. 12 Agency codes G & T must have ON-OFF or dual legends. Agency code J must have dual legend. 13 Other colors available. Consult factory. 14 Terminals 2,4 & 5 are shipped without terminal hardware. 15 2 or 3 Pole Circuit Breaker Required for 120/240 VAC Rating. 16 3 Pole Circuit Breaker Required for 120/208 VAC Rating. Max Rating 250A 700A 250A Max Rating 700A 700A 103 F-Series Handle – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 104 www.carlingtech.com F-Series Handle – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 105 F-Series Handle – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 106 www.carlingtech.com F-Series Handle – Form & Fit Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 107 F-Series Handle – Form & Fit Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 108 www.carlingtech.com F-Series Handle – Form & Fit Diagrams F-Series breakers are available up to 700A, and are also available with a 25 millivolt metering shunt construction. This optional construction provides a safe method for monitoring current flowing through the breaker by simply connecting a meter with light gauge wire to the appropriate terminals located on the shunt housing at the rear of the breaker. You can customize the application by measuring and displaying percentage of current, watts or safe/danger zones. Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com 109 F-Series Handle – Form & Fit Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 110 www.carlingtech.com M-Series Circuit Breakers - Time Delay Values Notes: 1 2 3 4 Delay Curves 12,14, 22, 24, 32, 34, 62, 64, 72, 74, 92, 94: Breakers to hold 100% and must trip at 135% of rated current and greater within the time limit shown in this curve. Delay Curves 10, 20, 30: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve. All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wall-mount position. The minimum inrush pulse tolerance handling capability is 12 times the rated current on standard delays and 18 times the rated current on high inrush delays. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse. High inrush delays should be specified for applications with high initial surge currents of short duration, such as switching power supplies, highly capacitive loads and transformer loads. Dual Rated AC/DC Instantaneous Short Short D2 Medium Medium D4 www.carlingtech.com 111 L, CX, A, B, C, H-Series Circuit Breakers - Time Delay Values L, CX, A, B, C, H-SERIES TIME VALUES PERCENT OF RATED CURRENT Notes: UL489 C-Series Breakers available with Delay Curves 11, 12, 14, 16, 21, 22, 24, 26, 42, 44, 46. Delay Curves 11,12,14,16,21,22,24,26,42,44,46,52,54,56: Breakers to hold 100% and must trip at 125% of rated current and greater within the time limit shown in this curve. Delay Curves 32,34,36: Breakers to hold 100% and must trip at 135% of rated current and greater within the time limit shown in this curve. Delay Curves 10,20: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve. All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wall-mount position. On 50 amp and less current ratings, the minimum inrush pulse tolerance handling capability is 12 times the rated current on standard delays and 25 times the rated current on high inrush delays. These values are based on a 60 Hz 1/2 cycle, 8.33 ms pulse. High inrush delays should be specified for applications with high initial surge currents of short duration such as switching power supplies, highly capacitive loads and transformer loads. DC TRIP TIME IN SECONDS AC TRIP TIME IN SECONDS Instantaneous PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT TRIP TIME IN SECONDS TRIP TIME IN SECONDS Ultrashort PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT TRIP TIME IN SECONDS TRIP TIME IN SECONDS Short PERCENT OF RATED CURRENT 112 PERCENT OF RATED CURRENT www.carlingtech.com L, CX, A, B, C, H-Series Circuit Breakers - Time Delay Values AC DC TRIP TIME IN SECONDS TRIP TIME IN SECONDS Medium PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT TRIP TIME IN SECONDS TRIP TIME IN SECONDS Long PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT TRIP TIME IN SECONDS High Inrush DC TRIP TIME IN SECONDS High Inrush AC Short TRIP TIME IN SECONDS PERCENT OF RATED CURRENT TRIP TIME IN SECONDS PERCENT OF RATED CURRENT Medium TRIP TIME IN SECONDS PERCENT OF RATED CURRENT www.carlingtech.com PERCENT OF RATED CURRENT TRIP TIME IN SECONDS PERCENT OF RATED CURRENT Long PERCENT OF RATED CURRENT 113 L, CX, A, B, C, H-Series Circuit Breakers - Time Delay Values AC/DC TRIP TIME IN SECONDS Short PERCENT OF RATED CURRENT TRIP TIME IN SECONDS Medium PERCENT OF RATED CURRENT TRIP TIME IN SECONDS Long PERCENT OF RATED CURRENT 114 www.carlingtech.com F-Series Circuit Breakers - Time Delay Values 11 .475 - 10.0 No Trip 14 16 22 24 26 Short .013 - .125 No Trip 12 10.0 - 110 110 - 1000 .700 - 12.0 10.0 - 160 50.0 - 700 No Trip No Trip No Trip No Trip No Trip AC .010 - .070 .008 - .032 .275 - 2.80 .140 - .850 6.00 - 40.0 60.0 - 400 .350 - 4.00 6.00 - 60.0 32.0 - 350 2.50 - 15.0 22.0 - 150 .130 - 1.30 .220 - 20.0 10.0 - 90.0 Ultrashort .005 - .020 .004 - .020 .030 - .190 .015 - .125 .004 - .020 .010 - .050 .008 - .038 .500 - 3.00 4.00 - 25.0 .027 - .220 .300 - 3.00 1.50 - 15.0 .180 - 1.00 1.00 - 5.50 .008 - .130 .050 - 1.30 .500 - 7.00 .010 - .280 .008 - .080 .008 - .390 .004 - .045 .005 - .060 .006 - 2.00 .006 - .020 .010 - 1.80 .004 - .090 .007 - .500 .020 - 3.00 DC TRIP TIME IN SECONDS TRIP TIME IN SECONDS F SERIES 50/60 HZ SHORT CURVE NO. 22 PERCENT OF RATED CURRENT Short PERCENT OF RATED CURRENT TRIP TIME IN SECONDS Medium TRIP TIME IN SECONDS F SERIES 50/60 HZ MEDIUM CURVE NO. 24 Medium PERCENT OF RATED CURRENT TRIP TIME IN SECONDS PERCENT OF RATED CURRENT Long TRIP TIME IN SECONDS F SERIES 50/60 HZ LONG CURVE NO. 26 PERCENT OF RATED CURRENT PERCENT OF RATED CURRENT www.carlingtech.com TRIP TIME IN SECONDS Long 115 Custom Power Distribution Units Custom Power Distribution Units Drawing on over 90 years of experience in the development of power switching and protection components, Carling Technologies offers custom designed and standard AC and DC power distribution units that exceed the tough demands of today’s applications while still offering safety, reliability and performance. A dedicated engineering team was established to provide design support and consultation to today’s taxed engineering staffs. Our goal is to design and develop a custom Power Distribution Unit or Battery Disconnect Panel that will meet your special requirements. Utilizing a comprehensive range of quality circuit protection and control products, you can specify the physical size of the enclosure and add your component requirements including temperature stable Carling Technologies’ hydraulicmagnetic circuit breakers, ground fault circuit protectors, transient voltage surge suppressors, meters, power receptacles, relays, bus bars, hole plugs and LED’s. Carling Technologies also offers a variety of standard AC Power Distribution Units and standard DC Power Distribution Units, including three different product series of one rack unit (1RU) panels designed to fit industry standard rack systems. All one rack unit products provide front access and utilize plug-in style circuit breakers that are “hot swappable.” A standard Battery Disconnect Panels with ratings up to 700 amps and interrupting capacity of 50,000A@ 125VDC is also available in sizes as small as 1RU x 19” and up to 3RU. Carling Technologies’ expertise in power distribution and electrical design can help you meet your power needs. Contact us with your requirements today. LAC1-Series Versatile design allows custom configurations of branch circuits based on application Circuit breakers snap-in to Carling’s exclusive circuit breaker mounting block, no need to hard wire breakers. LDC1-Series Hot “swappable” circuit breakers that can be installed, changed, or replaced in the field or factory Circuit breakers are front panel accessible. LBD1-Series Panel incorporates Carling F-Series high amperage hy-mag breakers, providing superior level of performance Panels sized for maximum protection in the smallest size possible to conserve valuable cabinet space, starting with a compact 1RU x 19” rack rated up to 250amps @ 125VDC with a 50,000AIC. 116 www.carlingtech.com Carling Technologies Catalogs There are several catalogs available featuring complete details on all Carling Technologies products. Below is a complete list of catalogs available on print and online as eCatalogs and downloadable PDF files. Please visit our website at carlingtech.com or scan the QR codes below for complete details. Carlingtech.com Visit us online for complete products and company information. Switches & Controls Switches and Controls Rocker, Toggle, Pushbutton & Rotary Hydraulic Magnetic Circuit Protection Hydraulic/Magnetic Circuit Breakers Features complete line and ordering details of Switches and Controls products including Rocker, Toggle, Pushbutton, and Rotary style switches. Features complete line and ordering details of all hydraulic/magnetic circuit breakers. Thermal’s GFCI’s Thermal Circuit Breaker Ground Fault Circuit Protection Reliable, Cost-effective Circuit Protection Features complete line and ordering details of all thermal circuit breakers. www.carlingtech.com Features complete line and ordering details of all GFCIs/ELCIs. 117 Carling Technologies Catalogs On-Off Highway ON–OFF Highway Switches & Controls CATALOG Features specific transportation products such as switches, controls and custom solutions. Marine Marine Switches, Circuit Breakers & ELCI/GFCIs Telecom/Datacom Telecom/Datacom Circuit Protection CATALOG Features all marine application products such as switches, ELCIs, thermal and hydraulic/ magnetic circuit breakers. Features complete line of hydraulic/magnetic circuit protection products specific for telecom and datacom systems. Military Renewable Energy Military Grade Renewable Energy Circuit Breakers and Disconnects COTS SWITCHES & CIRCUIT BREAKERS Features all COTS (Commercial-Off-The-Shelf ) Military grade switches and circuit breakers. 118 Features a complete line of circuit protection and disconnect products for photovoltaic energy systems. www.carlingtech.com Notes www.carlingtech.com 119 Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue • Plainville, CT 06062 Phone: (860) 793-9281 • Fax: (860) 793-9231 Email: [email protected] • www.carlingtech.com East Region Sales Office, CT • [email protected] Midwest Region Sales Office, IL • [email protected] West Region Sales Office, CA • [email protected] Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Kowloon, Hong Kong Int + 852-2737-2277 • Fax: Int + 852-2736-9332 Email: [email protected] Shenzhen, China • [email protected] Shanghai, China • [email protected] Pune, India • [email protected] Kaohsiung, Taiwan • [email protected] Yokohama, Japan • [email protected] Europe / Middle East/Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Int + 44 1392-364422 • Fax: Int + 44 1392-364477 Email: [email protected] GmbH, Germany • [email protected] SAS, France • [email protected] TELE/DATA-C_06_2013