M-Series General Specifications

M-Series General Specifications
The low cost M-Series utilizes the hydraulic magnetic principle
which provides accurate and reliable circuit protection even when
exposed to extremely hot and/or cold application environments.
Available in a choice of rocker actuator styles and colors, push
button, push-pull, paddle, and baton style handle actuators, the
Visi-Rocker® two-color actuators as well as non-illuminated or illuminated rocker versions with LED or neon bulbs. The exclusive
Rockerguard® bezel helps prevent inadvertent actuation. "Wiping"
contact design insures long term reliability. Various styling options
allow design flexibility.
Typical applications include power supplies, medical equipment,
and telecommunications equipment. In addition, these breakers
meet CSA Standard 22.2 No. 100 for the Generator & Welder
markets.
Agency Certifications
UL Recognized
UL Standard 1077
UL Listed
UL Standard 489A
CSA Accepted
Component Supplementary
Protector under Class 3215 30,
File 047848 0 000
CSA Standard C22.2 No. 235
VDE Certified
EN60934, VDE 0642 under File
10537
TUV Certified
EN60934, under License No.
R9671109
Component Recognition Program as
Protectors, Supplementary (Guide
CCN/QVNU2, File E75596)
Communications Equipment (Guide
CCN/DITT, File E189195)
Electrical
Table A: Lists UL Recognized and CSA Accepted configurations & performance capabilities as a Component Supplementary Protector.
NOTES FOR TABLE A
1
Polarity Sensitive
2
Available only with Special Catalog Number. Consult Factory.
3
Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 30 Amps maximum
4
Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 60 Amps maximum
18
www.carlingtech.com
M-Series General Specifications
Electrical
Table B: Lists UL Recognized,CSA Accepted and TUV and VDE Certified configurations and performance capabilities as a
Component Supplementary Protector.
NOTES FOR TABLE B
1
Polarity Sensitive
2
Available only with Special Catalog Number. Consult Factory.
3
Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 30 Amps maximum
4
TUV only, not VDE
5
Requires backup protection with a thermal magnetic circuit breaker rated 32 amps and having a Type C trip characteristic per EN60898/DIN VDE 0641 (C32A) for ratings greater than 15 amps,
and a thermal magnetic circuit breaker rated 16 amps and having a Type C trip characteristic per EN60898/DIN VDE 0641 (C16A) for ratings 15 amps and less.
Table C: Lists UL489A Listed and TUV Certified configurations and performance capabilities for use in Communications
Equipment.
NOTES FOR TABLE C
1. Available only with Special Caralog Number
www.carlingtech.com
19
M-Series General Specifications
Electrical
Maximum Voltage
Current Ratings
Auxiliary Switch Rating
Insulation Resistance
Dielectric Strength
Resistance, Impedance
Pulse Tolerance Curves
20
Mechanical
125/250 VAC 50/60 Hz, 80 VDC
(See Rating Tables.)
Standard current coils: 0.100, 0.250,
0.500, 0.750, 1.00 thru 15.0 in 1
amp increments, 18.0,
20.0, 25.0, 30.0. Other ratings available - see Ordering Scheme.
SPDT; 7A 250VAC, 7A (Res)
28VDC, 4A (Ind.) 28VDC, 0.25A
80VDC (Res) (silver contacts), 0.1A
125VAC (gold contacts).
Minimum of 100 Megohms at 500
VDC.
UL, CSA 1500V, 50/60 Hz for one
minute between all electrically isolated terminals. M-Series Circuit
Breakers comply with the 8mm
spacing and 3750 V 50/60Hz dielectric requirements from hazardous
voltage to operator accessible surfaces, per Publications IEC 380,
435, 950, EN 60950 and VDE 0805.
Values from Line to Load Terminal based on Series Trip Circuit Breaker.
Endurance
Trip Free
Trip Indication
10,000 ON-OFF operations @ 6 per
minute with rated Current and
Voltage.
All M-Series Circuit Breakers will trip
on overload, even when actuator is
forcibly held in the ON position.
The actuator moves positively to the
OFF position when an overload
causes the circuit breaker to trip.
Physical
Number of Poles
1 or 2
Internal Circuit Configurations Series with or without Auxiliary
Switch.
Switch Only with or without Auxiliary
Switch.
Weight
Approximately 30 grams/pole
(Approximately 1.07 ounces/pole)
Standard Colors
See Ordering Scheme.
Environmental
Designed and tested in accordance with requirements of specification MIL-PRF-55629 & MIL-STD-202 as follows:
Shock
Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Cond. I. Instantaneous
curves tested at 80% of rated current.
Vibration
Withstands 0.060" excursion from 1055 Hz, and 10 Gs 55-500 Hz, at rated
current per Method 204C, Test
Condition A. Instantaneous curves
tested at 80% of rated current.
Moisture Resistance
Method 106D, i.e., ten 24-hour
cycles @ + 25°C to +65°C, 80-98% RH.
Salt Spray
Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Thermal Shock
Method 107D, Condition A (Five
cycles @ -55°C to +25°C to +85°C
to +25°C).
Operating Temperature
-40° C to +85° C
Chemical Resistance
Only the outside surfaces of the case
and the handles may be cleaned with
detergents or alcohol. Organic (hydrocarbon based) solvents are not recommended because they attack plastics. Caution should be taken when
solvents are used to clean and
remove flux from terminals. Lubricants
should not be introduced into the handle/bushing openings.
www.carlingtech.com
M-Series Handle/Pushbutton UL Recognized - Ordering Scheme
M M 1 – B – 34 – 260 – 1 – 1 B B – B – C
1
Series
2
Actuator
3
Poles
5
Frequency
& Delay
4
Circuit
6
Current Rating
1 SERIES
M
2 ACTUATOR 1
Handle
M
Paddle
N
Baton
Push Button
T
Push-Pull
U
Push To Reset
Push Button w/ Snap-In Mounting
V
Push-Pull
W
Push To Reset
3 POLES
1
One
2
32
34
62
64
72
74
92
94
DC, 50/60Hz Short
DC, 50/60Hz Medium
50/60Hz Short, Hi-Inrush
50/60Hz Medium, Hi-Inrush
DC, Short,Hi-Inrush
DC, Medium, Hi-Inrush
DC, 50/60Hz Short, Hi-Inrush
DC, 50/60Hz, Medium, Hi-Inrush
Notes:
1
One actuator is located in the center of each multi-pole breaker. Actuator codes V & W
limited to single pole breakers only.
2
Switch Only circuits are not available with Push-To-Reset actuators.
For Switch Only circuits, select Current Coil Rating from the following chart:
3
4
5
6
7
8
9
10
11
12
13
One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary
Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip and Switch
Only circuits. Not available with back connect screw or push-in stud terminals.
Mates with AMP .058" diameter pin receptacles including 60983-1 (gold plated) and 609832 (tin plated).
Actuator color is only visible in the OFF position on Push-Pull actuators.
All units except snap-in mounting have one hex nut installed on bushing for use behind the
panel.
Other colors available. Consult factory.
TUV and VDE Certification above 15 amps is for 2-pole only and is limited to a max. of 25
amps. Screw Terminal or Push-In Stud recommended above 20 amps.
30 amp rating not available with delay’s 30, 32, 34, 92 or 94.
Screw Terminals are VDE certified only with use of ring terminal attached to wire.
Terminal code A available with circuit codes A & B only.
Printed circuit board available with UL recognized approval only.
Auxiliary switch (flat Q.C.) available with UL recognized approvals only.
www.carlingtech.com
8
Actuator
Color
10
9
Front Panel Legend
Hardware Plate
6 CURRENT RATING (AMPERES)8
020
0.020
225
0.250
025
0.025
230
0.300
030
0.030
235
0.350
035
0.035
240
0.400
040
0.040
245
0.450
045
0.045
250
0.500
050
0.050
255
0.550
055
0.055
260
0.600
060
0.060
265
0.650
065
0.065
270
0.700
070
0.070
275
0.750
075
0.075
280
0.800
080
0.080
285
0.850
085
0.085
290
0.900
090
0.090
295
0.950
095
0.095
410
1.000
210
0.100
512
1.250
215
0.150
415
1.500
220
0.200
517
1.750
12
Agency
Approval
11
Bushing
Color
710
611
711
612
712
613
614
615
616
617
717
618
619
620
622
624
625
6309
420
522
425
527
430
435
440
445
450
455
460
465
470
475
480
485
490
495
610
2.000
2.250
2.500
2.750
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
A11
P12
Push-In Stud
Printed Circuit Board
10.500
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
17.500
18.000
19.000
20.000
22.000
24.000
25.000
30.000
Two
4 CIRCUIT 2
without Auxiliary Switch
A
Switch Only (No Coil), Maintained Contacts
B
Series Trip (Current)
with Auxiliary Switch, Silver Contacts
Terminal Type:
P3
Switch Only, Maintained Contacts
.060 Dia, Round Solder Turret
Q3, 4 Switch Only, Maintained Contacts
.058 Dia, Round Q.C.
R3, 13 Switch Only, Maintained Contacts
.080 Dia x .020 Flat Q.C.
S3
Series Trip (Current)
.060 Dia, Round Solder Turret
T3, 4 Series Trip (Current)
.058 Dia, Round Q.C.
U3, 13 Series Trip, Maintained Contacts
.080 Dia x .020 Flat Q.C.
with Auxiliary Switch, Gold Contacts
23, 4 Switch Only, Maintained Contacts
.058 Dia, Round Q.C.
33, 13 Switch Only, Maintained Contacts
.080 Dia x .020 Flat Q.C.
43,4 Series Trip (Current)
.058 Dia, Round Q.C.
53, 13 Series Trip, Maintained Contacts
.080 Dia x .020 Flat Q.C.
5 FREQUENCY & DELAY
03
DC 50/60Hz, Switch Only
10
DC Instantaneous
12
DC Short
14
DC Medium
20
50/60Hz Instantaneous
22
50/60Hz Short
24
50/60Hz Medium
30
DC, 50/60Hz Instantaneous
7
Terminal
7 TERMINAL 8
1
Push-On 0.250 Tab (Q.C.)
Screw 8-32 w/upturned lugs
210
10
Screw 8-32 (Bus Type)
3
8 ACTUATOR COLOR5
Handle
Push-Button
1
A
2
B
3
C
4
D
5
E
6
F
8
H
Actuator Color
White
Black
Red
Green
Blue
Yellow
Orange
9 FRONT PANEL HARDWARE 6
Handle
No outer Panel Hardware
A
Knurled Nut
Bright nickel
B
Bright nickel w/ locking ring
C
Black
D
Black w/ locking ring
E
Panel Dress Nut
Bright nickel
F
Bright nickel w/ locking ring
G
Black
H
Black w/ locking ring
J
Push-Button
1
2
10 LEGEND PLATE / BUTTON MARKING
Handle Actuator Legend Plate (Actuator Styles M & N)
A
No Legend Plate
B
ON - OFF Vertical
C
ON - OFF Horizontal
D
I - O Vertical
E
I - O Horizontal
Push-Pull Actuator Button Cap (Actuator Styles T & V)
1
No Marking
2
Rated Amps Horizontal
3
Rated Amps Line Side Down
4
Rated Amps Line Side Up
Push-to-Reset Actuator Button (Actuator Styles U& W)
1
No Marking
11 BUSHING COLOR 7
B
Black
12 AGENCY APPROVAL 8
C
UL Recognized & CSA Accepted
D
VDE Certified, UL Recognized & CSA Accepted
E
TUV Certified, UL Recognized & CSA Accepted
21
M-Series Handle/Pushbutton UL489A/UL Recognized – Ordering Scheme
M M 1 – B – 14 – 620 – 1 – 1 B B – B – J
1
Series
2
Actuator
3
Poles
5
Frequency
& Delay
4
Circuit
6
Current Rating
1 SERIES
M
7
Terminal
8
Actuator
Color
10
9
Front Panel Legend
Hardware
Plate
7 TERMINAL4
1
Push-On 0.250 Tab (Q.C.)
2
Screw 8-32 w/upturned lugs
3
Screw 8-32 (Bus Type)
2 ACTUATOR 1
Handle
M
Paddle
N
Baton
Push Button
T
Push-Pull
U
Push To Reset
Push Button w/ Snap-In Mounting
V
Push-Pull
W
Push To Reset
8 ACTUATOR COLOR & LEGEND 5
Gloss Handle
Push-Button
1
A
2
B
3
C
4
D
5
E
6
F
8
H
3 POLES
1
One
4 CIRCUIT
without Auxiliary Switch
B
Series Trip (Current)
with Auxiliary Switch, Silver Contacts
S 2 Series Trip (Current)
T 2,3 Series Trip (Current)
U3, 12 Series Trip, Maintained Contacts
with Auxiliary Switch, Gold Contacts
42,3 Series Trip (Current)
53, 12 Series Trip, Maintained Contacts
Terminal Type:
.060 Dia, Round Solder Turret
.058 Dia, Round Q.C.
.080 Dia x .020 Flat Q.C.
.058 Dia, Round Q.C.
.080 Dia x .020 Flat Q.C.
5 FREQUENCY & DELAY
12
DC Short
14
DC Medium
72
74
DC, Short, Hi-Inrush
DC, Medium, Hi-Inrush
6 CURRENT RATING (AMPERES)
020
0.020
225
0.250
025
0.025
230
0.300
030
0.030
235
0.350
035
0.035
240
0.400
040
0.040
245
0.450
045
0.045
250
0.500
050
0.050
255
0.550
055
0.055
260
0.600
060
0.060
265
0.650
065
0.065
270
0.700
070
0.070
275
0.750
075
0.075
280
0.800
080
0.080
285
0.850
085
0.085
290
0.900
090
0.090
295
0.950
095
0.095
410
1.000
210
0.100
512
1.250
215
0.150
415
1.500
220
0.200
517
1.750
420
522
425
527
430
435
440
445
450
455
460
465
470
475
480
485
490
495
610
2.000
2.250
2.500
2.750
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
710
611
711
612
712
613
614
615
616
617
717
618
619
620
622
624
625
630
10.500
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
17.500
18.000
19.000
20.000
22.000
24.000
25.000
30.000
9 FRONT PANEL HARDWARE 6
Handle
No outer Panel Hardware
A
Knurled Nut
bright nickel
B
bright nickel w/ locking ring
C
black
D
black w/ locking ring
E
Panel Dress Nut
bright nickel
F
bright nickel w/ locking ring
G
black
H
black w/ locking ring
J
A10
P11
11
Bushing
Color
12
Agency
Approval
Push-In Stud
Printed Circuit Board
Actuator Color
White
Black
Red
Green
Blue
Yellow
Orange
Push-Button
1
2
10 LEGEND PLATE / BUTTON MARKING
Handle Actuator Legend Plate (Actuator Styles M & N)
A
No Legend Plate
B
ON - OFF Vertical
C
ON - OFF Horizontal
D
I - O Vertical
E
I - O Horizontal
Push-Pull Actuator Button Cap (Actuator Styles T & V)
8
1
No Marking
2
Rated Amps Horizontal
3
Rated Amps Line Side Down
4
Rated Amps Line Side Up
Push-To-Reset Actuator Button Cap (Actuator Styles U & W)
8
1
No Marking
11 BUSHING COLOR 7
B
Black
12 AGENCY APPROVAL 9
J
UL489A Listed, TUV Certified
M
UL Recognized, CSA Accepted
N
UL Recognized, TUV Certified
T
UL489A Listed
Notes:
1
One actuator is located in the center of each multi-pole breaker. Actuator codes V & W
limited to single pole breakers only.
2
One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary
Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip and Switch
Only circuits. Not available with Back Connected Screw or Push-in Stud terminals.
3
Mates with AMP .058" diameter pin receptacles including 60983-1 (gold plated) and
60983-3 (tin plated).
4
Screw terminals or Push-in Stud recommended above 20 amps.
5
Actuator color is only visible in the OFF position on Push-Pull actuators.
6
All units have one hex nut installed on bushing for use behind the panel.
7
Other colors available. Consult factory.
8
Not available with UL489A Listed breakers.
9
TUV certified to 25 amps. UL Recognized, CSA Accepted and UL Listed to 30 amps.
10
Terminal code A available with circuit codes A & B only.
11
Printed circuit board available with UL recognized approval only.
12
Auxiliary switch (flat Q.C.) available with UL recognized approvals only.
22
www.carlingtech.com
M-Series Rocker UL Recognized – Ordering Scheme
M G 2 – B – 34 – 620 – 1
1
Series
2
Actuator
3
Poles
6
Current Rating
5
Frequency
& Delay
4
Circuit
1 SERIES
M
2 ACTUATOR 1
Non-Illuminated
single color
A
Angled
B
Flat
Two Color
Visi-Rocker
D
Indicate ON
E
Indicate OFF
3 POLES
1
One
2
llluminated
single color
F
Angled
G
Flat
6 CURRENT RATING (AMPERES)10
020
0.020
225
0.250
025
0.025
230
0.300
030
0.030
235
0.350
035
0.035
240
0.400
040
0.040
245
0.450
045
0.045
250
0.500
050
0.050
255
0.550
055
0.055
260
0.600
060
0.060
265
0.650
065
0.065
270
0.700
070
0.070
275
0.750
075
0.075
280
0.800
080
0.080
285
0.850
085
0.085
290
0.900
090
0.090
295
0.950
095
0.095
410
1.000
210
0.100
512
1.250
215
0.150
415
1.500
220
0.200
517
1.750
7 TERMINAL 10
1
Push-On 0.250 Tab (Q.C.)
2 13 Screw 8-32 w/upturned lugs
13
Screw 8-32 (Bus Type)
3
www.carlingtech.com
DC, 50/60Hz Short
DC, 50/60Hz Medium
50/60Hz Short, Hi-Inrush
50/60Hz Medium, Hi-Inrush
DC, Short, Hi-Inrush
DC,Medium, Hi-Inrush
DC, 50/60Hz Short, Hi-Inrush
DC, 50/60Hz, Medium, Hi-Inrush
420
522
425
527
430
435
440
445
450
455
460
465
470
475
480
485
490
495
610
2.000
2.250
2.500
2.750
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
A14
P15
Push-In Stud
Printed Circuit Board
710
611
711
612
712
613
614
615
616
617
717
618
619
620
622
624
625
63012
10.500
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
17.500
18.000
19.000
20.000
22.000
24.000
25.000
30.000
10
Legend
A
Neon
B
Red
D
E
F
12
Agency
Approval
11
Bezel
Color
Green Glow8
C
Green
G
H
J
Amber
K
L
M
9 ACTUATOR & LEGEND COLOR
Solid Color Actuator
Legend
1
White
Black
2
Black
White
3
Red
White
4
Green
White
5
Blue
White
6
Yellow
Black
7
Gray
Black
8
Orange
Black
6
Visi-Rocker Visi & Legend (remainder of rocker same color as bezel)
1
White
2
Black
3
Red
4
Green
5
Blue
6
Yellow
7
Gray
8
Orange
Illuminated 8 Actuator
Legend
A
Clear
White
B
Red Transparent
White
C
Green Transparent
White
D
Amber Transparent
White
E
Smoke Gray Transparent
White
F
White Translucent
Black
Two
32
34
62
64
72
74
92
94
H C 6 – 7 –C
9
8
Illumination Actuator
Color
8 ROCKER ILLUMINATION
Non-illuminated
Neon 5
without resistor, 120VAC/250VAC
LED 7, 8
without resistor
with resistor, 4-8 VDC
with resistor, 9-16 VDC
4 CIRCUIT 2
without Auxiliary Switch
A
Switch Only (No Coil), Maintained Contacts
B
Series Trip (Current)
with Auxiliary Switch, Silver Contacts
Terminal Type:
P3
Switch Only, Maintained Contacts
.060 Dia, Round Solder Turret
Q3, 4 Switch Only, Maintained Contacts
.058 Dia, Round Q.C.
R3, 16 Switch Only, Maintained Contacts
.080 Dia x .020 Flat Q.C.
S3
Series Trip (Current)
.060 Dia, Round Solder Turret
T3, 4 Series Trip (Current)
.058 Dia, Round Q.C.
U3, 16 Series Trip, Maintained Contacts
.080 Dia x .020 Flat Q.C.
with Auxiliary Switch, Gold Contacts
23, 4 Switch Only, Maintained Contacts
.058 Dia, Round Q.C.
33, 16 Switch Only, Maintained Contacts
.080 Dia x .020 Flat Q.C.
43,4 Series Trip (Current)
.058 Dia, Round Q.C.
53, 16 Series Trip, Maintained Contacts
.080 Dia x .020 Flat Q.C.
5 FREQUENCY & DELAY
03
DC 50/60Hz, Switch Only
10
DC Instantaneous
12
DC Short
14
DC Medium
20
50/60Hz Instantaneous
22
50/60Hz Short
24
50/60Hz Medium
30
DC, 50/60Hz Instantaneous
7
Terminal
10 LEGEND11
1
No Legend
2
ON - OFF Vertical
3
ON - OFF Horizontal
4
I - O Vertical
11 BEZEL COLOR / STYLE 9
Color
without Rockerguard
White
A
Black
B
Gray
G
5
6
7
I - O Horizontal
Dual Vertical
Dual Horizontal
with Rockerguard
1
2
7
12 AGENCY APPROVAL10
C
UL Recognized & CSA Accepted
D
VDE Certified, UL Recognized & CSA Accepted
E
TUV Certified, UL Recognized & CSA Accepted
Notes:
1
One actuator is located in the center of each multi-pole breaker.
2
For Switch Only circuits, select Current Coil Rating from the following chart:
3
4
5
6
7
8
9
10
11
12
13
14
15
16
One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary Switch
mounting is in pole one. Auxiliary Switch option limited to Series Trip & Switch Only circuits, & is not
available in single pole illuminated breakers, or Back Connected Screw or Push-in Stud terminals.
Mates with AMP .058" diameter pin receptacles: 60983-1 (gold plated) & 60983-2 (tin plated).
For neon bulb applications at 120VAC @ 47K, 1/4 WATT and for 250VAC applications @ 150K,
1/4 WATT, external resistors must be supplied by customer.
On Visi-Rocker breakers, Visi portion of rocker cannot be the same color as the bezel.
For LED (DC or rectified AC) applications, LED is mounted in the center of the rocker actuator with
electrical characteristics: 100 millicandela at 20mA; Maximum power dissipation = 75mW at 25°C;
Maximum forward current = 25mA; Typical forward voltage = 2.1V at 20mA; Typical reverse current
= 100uA at 3V. Customer supplies the proper external resistor limiting current to these values.
Rocker color for LED’s and green neon lamp must be clear, smoke gray, white translucent or
match color of LED or neon lamp.
Other colors available. Consult factory.
TUV and VDE Certified to 25 amps. UL Recognized and CSA Accepted to 30 amps. Screw
Terminals or Push-in Stud recommended above 20 amps.
TUV or VDE Certified must have I-O or Dual Legends. Legend required on Visi-Rocker breakers.
30 amp rating not available with delay’s 30, 32, 34, 92 or 94.
Screw Terminals are VDE certified only with use of ring terminal attached to wire.
Terminal code A available with circuit codes A & B only.
Printed circuit board available with UL recognized approval only.
Auxiliary switch (flat Q.C.) available with UL recognized approvals only.
23
M-Series Rocker UL489A/UL Recognized – Ordering Scheme
M A 1 – B – 14 – 620 – 1 – A 1 6 – 2 – J
1
Series
2
Actuator
3
Poles
6
Current Rating
5
Frequency
& Delay
4
Circuit
1 SERIES
M
2 ACTUATOR 1
Non-Illuminated single color
A
Angled
Two Color Visi-Rocker
D
Indicate ON
llluminated single color
F
Angled
B
Flat
E
Indicate OFF
G
Flat
Terminal Type
.060 Dia, Round Solder Turret
.058 Dia, Round Q.C.
.080 Dia x .020 Flat Q.C.
.058 Dia, Round Q.C.
.080 Dia x .020 Flat Q.C.
5 FREQUENCY & DELAY
10
DC Instantaneous
12
DC Short
14
72
74
DC Medium
DC, Short,Hi-Inrush
DC, Medium, Hi-Inrush
6 CURRENT RATING (AMPERES)
020
0.020
225
0.250
025
0.025
230
0.300
030
0.030
235
0.350
035
0.035
240
0.400
040
0.040
245
0.450
045
0.045
250
0.500
050
0.050
255
0.550
055
0.055
260
0.600
060
0.060
265
0.650
065
0.065
270
0.700
070
0.070
275
0.750
075
0.075
280
0.800
080
0.080
285
0.850
085
0.085
290
0.900
090
0.090
295
0.950
095
0.095
410
1.000
210
0.100
512
1.250
215
0.150
415
1.500
220
0.200
517
1.750
420
522
425
527
430
435
440
445
450
455
460
465
470
475
480
485
490
495
610
2.000
2.250
2.500
2.750
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
8.500
9.000
9.500
10.000
A11
P12
Push-In Stud
Printed Circuit Board
7 TERMINAL 9
1
Push-On 0.250 Tab (Q.C.)
2
Screw 8-32 w/upturned lugs
3
Screw 8-32 (Bus Type)
8 ILLUMINATION
Non-illuminated
Neon 4
without resistor, 120VAC/250VAC
LED
without resistor 5, 7
with resistor, 4-8 VDC
with resistor, 9-16 VDC
24
A
Neon
B
Red
D
E
F
Green Glow 7
C
Green
G
H
J
9
8
Illumination Actuator
Color
10
Legend
11
Bezel
Color
12
Agency
Approval
9 ACTUATOR & LEGEND COLOR
Solid Color Actuator
Legend
1
White
Black
2
Black
White
3
Red
White
4
Green
White
5
Blue
White
6
Yellow
Black
7
Gray
Black
8
Orange
Black
6
Visi-Rocker Visi & Legend (remainder of rocker same color as bezel)
1
White
2
Black
3
Red
4
Green
5
Blue
6
Yellow
7
Gray
8
Orange
7
Illuminated Actuator
Legend
A
Clear
White
B
Red Transparent
White
C
Green Transparent
White
D
Amber Transparent
White
E
Smoke Gray Transparent
White
F
White Translucent
Black
3 POLES
1
One
4 CIRCUIT2
without Auxiliary Switch
B
Series Trip (Current)
with Auxiliary Switch, Silver Contacts
S
Series Trip (Current)
T3
Series Trip (Current)
U3, 13 Series Trip, Maintained Contacts
with Auxiliary Switch, Gold Contacts
43
Series Trip (Current)
53, 13 Series Trip, Maintained Contacts
7
Terminal
710
611
711
612
712
613
614
615
616
617
717
618
619
620
622
624
625
630
Amber
K
L
M
10.500
11.000
11.500
12.000
12.500
13.000
14.000
15.000
16.000
17.000
17.500
18.000
19.000
20.000
22.000
24.000
25.000
30.000
10 LEGEND10
1
No Legend (Single Color or Illuminated Rocker Options Only)
2
ON - OFF Vertical
3
ON - OFF Horizontal
4
I - O Vertical
5
I - O Horizontal
6
Dual Vertical
7
Dual Horizontal
11 BEZEL COLOR / STYLE8
Color
without Rockerguard
White
A
Black
B
Gray
G
with Rockerguard
1
2
7
12 AGENCY APPROVAL9
J
UL489A Listed & TUV Certified
M
UL Recognized & CSA Accepted
N
TUV Certified, UL Recognized & CSA Accepted
T
UL489A Listed
Notes:
1
One actuator is located in the center of each multi-pole breaker.
2
One Auxiliary Switch is supplied per breaker. Auxiliary Switch option limited to Series Trip &
Switch Only circuits, and is not available in single pole illuminated breakers, or with Back
Connected Screw or Push-in Stud terminals.
3
Mates with AMP .058" diameter pin receptacles: 60983-1 (gold plated) & 60983-1 (tin plated).
4
For neon bulb applications at 120VAC @ 47K, 1/4 WATT and for 250VAC applications @
150K, 1/4 WATT, external resistors must be supplied by customer.
5
For LED (DC or rectified AC) applications, LED is mounted in the center of the rocker actuator with electrical characteristics as follows: 100 millicandela at 20mA; Maximum power dissipation = 75mW at 25°C; Maximum forward current = 25mA; Typical forward voltage =
2.1V at 20mA; Typical reverse current = 100uA at 3V. Customer supplies the proper external resistor limiting current to these values.
6
On Visi-Rocker breakers, Visi portion of rocker cannot be the same color as the bezel.
7
Rocker color for LED’s and green neon lamp must be clear, smoke gray, white translucent
or match color of LED or neon lamp.
8
Other colors available. Consult factory.
9
TUV Certified to 25 amps. UL Recognized, CSA Accepted and UL489A Listed to 30 amps.
Screw Terminals recommended above 20 amps.
10
UL489A Listed must have ON-OFF or Dual legends. TUV Certified approvals must have
I - O or Dual legends.
11
Terminal code A available with circuit codes A & B only.
12
Printed circuit board available with UL recognized approval only.
13
Auxiliary switch (flat Q.C.) available with UL recognized approvals only.
www.carlingtech.com
M-Series Handle – Circuit & Terminal Diagrams
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.020 [.51] unless otherwise specified.
www.carlingtech.com
25
M-Series Handle – Form & Fit Drawings
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ± 0.20 [.51] unless otherwise specified.
26
www.carlingtech.com
M-Series Handle – PC Terminal Diagrams
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.020 [.51] unless otherwise specified.
www.carlingtech.com
27
M-Series Pushbutton – Circuit & Terminal Diagrams
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.020 [.51] unless otherwise specified.
28
www.carlingtech.com
M-Series Pushbutton – Form & Fit Drawings
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ± 0.20 [.51] unless otherwise specified.
3
Available with Push-Pull or Push-to-Reset Actuators.
www.carlingtech.com
29
M-Series Push-Pull – PC Terminal Drawings
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.020 [.51] unless otherwise specified.
30
www.carlingtech.com
M-Series Rocker – Circuit & Terminal Diagrams
Notes:
1
All dimensions are in inches [millimeters].
2
Tolerance ±.020 [.51] unless otherwise specified.
3
Schematic shown represents current trip circuit.
www.carlingtech.com
31
M-Series Rocker – Form & Fit Drawings
Notes:
1
Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate OFF is opposite of indicate ON.
2
I-O, ON-OFF or dual legends available for vertical or horizontal mounting. For pole orientation with horizontal legend, rotate front view clockwise 90°.
3
All dimensions are in inches [millimeters].
4
Tolerance ± 0.20 [.51] unless otherwise specified.
32
www.carlingtech.com
M-Series Rocker – Supplementary Diagrams