Test Equipment COMPLETE LINE Analog Multimeter AM-10 • Pocket Size - Very Economical • 6 Functions, 10 Ranges • ±4% Basic DC Accuracy • 2” Mirrored Scale • 2KΩ/V AC & DC Input Sensitivity • Fuse and Diode Protection • DC Current • Resistance • Decibels • Battery Test • 90-Day Limited Warranty Test Leads (ML-10) and Operating Instructions Included SPECIFICATIONS: General Front/Side Controls: Range selector switch, “0” Ω adjustment Movement: 90° arc, 200µA full scale Scales (5): One scale for OHMS, 2 scales for AC/DC, one scale for dB and Battery test Scale Length: 2” Operating Position: Horizontal or vertical Power: 1.5V AA battery (not included) Movement and Indicator Protection: Diode and Fuse (0.5A, 250V) Dimensions, Weight: 2.4” wide x 3.5” long x 1.1” thick (60mm x 89mm x 29mm), net weight 4oz. (113g) DC Voltage AC Voltage Ranges: 0-15, 150, 500V Input Impedance: 2kΩ per Volt Rated Accuracy: ±4% of full scale Ranges: 0-15, 150, 500V Input Impedance: 2kΩ per Volt Rated Accuracy: ±5% of full scale DC Current Resistance Ranges: 0-150mA Rated Accuracy: ±4% of full scale Ranges: R x 1K 0 - 1MΩ (full scale) 2 Decibels Ranges: -20dB to +26dB on 15V AC range 0dB to +46dB on 150V AC range 10dB to +56dB on 500V AC range Battery Test Ranges: 1.5V AA 800-631-1250 • www.nteinc.com Analog Multimeter AM-30 • Our Top Of The Line Analog Meter • Full Function • Temperature Measurement • 1000 Volts AC/DC • Transistor Test • Battery Test • Continuity Buzzer • Tilt Stand/Carrying Handle • 90-Day Limited Warranty • 3% DC Accuracy FS • 5” Mirrored Scale • 30KΩ/V DC, 10KΩ/V AC Input Sensitivity • Fuse and Diode Protection • 10 Amp DC Range Test Leads (ML-43), Temperature Probe (TC-30), Fuse and Operating Instructions Included SPECIFICATIONS: General Front Panel Controls: Range selector switch with “OFF” position, 0Ω adjust/ temperature calibration, 0Ω calibration switch Movement: 90° arc, 25µA movement Scales (8): One scale for OHMS, three scales for AC/DC, one scale for dB, two scales for temperature, one scale for battery test Scale Length: 5” Operating Position: Horizontal or vertical; rubber pads to prevent slipping on moderate horizontal slopes Power: 9V (NEDA 1604) and 1.5V AA (2) batteries (not included) Movement and Indicator Protection: Fuse (0.5A, 250V) Operating Temperature: 18°C to 25°C for rated accuracy Dimensions, Weight: 4.8” wide x 6.9” long x 1.9” thick (127mm x 175mm x 48mm), net weight 14oz. (422g) DC Voltage AC Voltage Decibels Ranges: 0-0.6, 3, 12, 60, 300, 1000V Input Impedance: 30kΩ per Volt Rated Accuracy: ±3% of full scale Ranges: 0-12, 30, 120, 300, 1000V Input Impedance: 10kΩ per Volt Rated Accuracy: ±4% of full scale DC Current Resistance Ranges: 120µ, 13m, 30m, 300m, 10A Rated Accuracy: ±3% of full scale Ranges: R x 1 0-5kΩ R x 100 0-500kΩ R x 1k 0-5MΩ R x 10k 0-50MΩ Rated Accuracy: 3° arc Ranges: -10dB to +24dB on 12V AC range -2dB to +32dB 8dB to +44dB 20dB to +52dB 30dB to +62dB 0dB referenced to 1 milliwatt at 600Ω Temperature Ranges: -50°C to +260°C (-60°F to +400°F) Battery Test Ranges: 1.5V AA, 9V 800-631-1250 • www.nteinc.com 3 Analog Multimeter FET-43 • Very High Input Impedance • Excellent Trouble Shooting Tool • 5 Functions, 43 Ranges • 4.5” Meter Scale • ±2.5% DC accuracy FS • 10MΩ DC, 1MΩ AC Input Resistance • FET Input • Jeweled Meter Movement • Overload Protection † • Polarity Reversing Switch * • Zero Center Scale Adjustment • Low Battery Indicator • Metal Tilt Stand • 1-Year Limited Warranty Battery, Test Leads (ML-43) and Operating Instructions Included SPECIFICATIONS: General Front Panel Controls: Range selector switch, power on-off switch, with operational LED, polarity reverse switch, “0” Ω ADJ, Center “0” ADJ Movement: Jeweled pivots, 90° arc, 44µA full scale Scales (9): Ω DC V•A, AC RMS, AC peak to peak (2), ±DC V•A (center null), AC 12 A, DC 0.1µA, dB Scale Length: 4.5” *Polarity Reverse Switch: DC and Ω ranges (Reverses meter movement only. Does not reverse test lead polarity.) Operating Position: Horizontal or vertical, rubber pads to prevent slipping on moderate slopes Power: 1.5V AA (2) and 9V (NEDA 1604) batteries Movement and Indicator Protection: Double FET protection and fuse (2A/250V) Operating Temperature: 25°C (75°F) rated accuracy, less than 4% additional error over the range of -4°C (25°F) to 50°C (130°F) Dimensions, Weight: 5” wide x 6.75” long x 2” thick (125mm x 170mm x50mm), net weight 17oz. (480g) DC Voltage AC Voltage AC Current Ranges: 0-0.3, 1.2, 3.0, 120, 300, 1200V, 0-±1.5, 0.6, 6, 15, 60, 150, 600V at Center 0 Input Impedance: Approx. 10MΩ, 3MΩ on 300 mV range Rated Accuracy: ±2.5% DC and ±3.5% AC of full scale on all ranges Ranges: RMS 0-3, 12, 30, 120, 300, 1200V, peak to peak, 0-8.4, 33, 84, 330, 840, 3300RMS, 1200V (peak to peak 3300V) on separate jack Input Impedance: Approx. 1MΩ, 800pF; 2.5MΩ on 3V range Rated Accuracy: 50Hz - 5MHz ±3% 30Hz - 10MHz ±1dB sine wave 30Hz - 1MHz ±1dB rectangular wave at 3V range only 30Hz - 3MHz ±5% sine wave 30Hz - 120MHz ±5% rectangular on all other ranges except 3V dB: -10dB - +63dB on AC ranges Ranges: 0-12A, within ± 3.5% full scale. DC, AC,12 Amp range on separate jack DC Current Ranges: 0-0.1µA, 0.3, 3, 30, 300mA, 12A Potential Drop: 300mV Rated Accuracy: Within ±2.5% full scale on all ranges 4 Resistance Ranges: Rx1 0 - 1KΩ (Center 10) R x 10 0 - 10KΩ (Center 100Ω) R x 100 0 - 100KΩ (Center 1KΩ) R x 1K 0 - 1MΩ (Center 10KΩ) R x 10K 0 - 10MΩ (Center 100KΩ) R x 1M 0 - 1000MΩ (Center 10MΩ) Accuracy: ±2.5° of arc † Does not apply to 12 Amp range. Damage to meter or injury to operator can occur if voltage or excessive current is applied to 12 Amp. input. 800-631-1250 • www.nteinc.com Digital Multimeter DM-21 • Low Cost General Purpose • Low Power Ω • Overload Protection • RF Shielded • Polarity Indicator • Low Battery Indicator • Tilt Stand • 1-Year Limited Warranty • Transistor hFE • Diode Test • LED Test • Square Wave Generator • 7 Functions, 11 Ranges • 0.8% Basic DC Accuracy • 3 1/2 Digit LCD, 0.55” H Battery, Test Leads (ML-375) and Operating Instructions Included SPECIFICATIONS: General Display: 3 1/2 Digit LCD, 0.55” high, with polarity Overrange Indication: “1” or “–1” is displayed. Measurement Rate: 2.5 times per second Operating Environment: 0°C to 50°C, <70% relative humidity Storage Environment: -20°C to 60°C, <80% relative humidity with battery removed Power: 9V carbon zinc battery (NEDA 1604) Battery Life: 150 hours typical with carbon zinc cells Low Battery Indicator: Symbol is displayed Dimensions, Weight: 2.8” wide x 6” long x 1.5” thick (70mm x 151mm x 38mm), net weight 7oz. (200g) DC Voltage Resistance LED Test Range Resolution Accuracy 2V 1mV ±0.8% of rdg ±1D 20V 10mV ±0.8% of rdg ±1D 200V 100mV ±0.8% of rdg ±1D 600V 1V ±0.8% of rdg ±1D Input Impedance: 1MΩ on all ranges. Maximum Input: 600V DC or 500AC rms. Range Resolution Accuracy 200Ω 0.1Ω ±1.5% of rdg ±3D 2KΩ 1Ω ±1.5% of rdg ±3D 20KΩ 10Ω ±1.5% of rdg ±3D 200KΩ 100Ω ±1.5% of rdg ±3D 2MΩ 1KΩ ±1.5% of rdg ±3D Overload Protection: 500V DC or 350AC rms Voltage: <3.5V @ 10mA ±0.6mA AC Voltage Transistor hFE Test (PNP, NPN) Range Resolution Accuracy 200V 100mV ± 1.5% of rdg ±4D 500V 1V ± 1.5% of rdg ±4D Input Impedance: 450KΩ on all ranges. Maximum Input: 600V DC or 500AC rms. Frequency Range: 50Hz - 500Hz. Generator Waveform: Square Frequency: 50Hz approx Output: ±3 to -0.5V DC, 50% Duty Cycle Impedance: 120KΩ Test Condition: 10µA Base Current @ <3.5V hFE Range: 0 - 1000 Diode Test Voltage: <3.5V @ 1mA ±0.6mA 800-631-1250 • www.nteinc.com 5 Digital Multimeter DM-38A • Multifunction DMM • Heavy Duty • 3 3/4 Digit, 0.5” H • Peak Data Hold • Overload Protection • RF Shielded • Lo Power Ohms • Tilt Stand • Polarity Indicator • Overrange Indicator • Low Battery Indicator • 1-Year Limited Warranty • Frequency Counter • Capacitance Test • Logic Detector • 20A AC/DC • 0.5% Basic DC Accuracy • 40MΩ Full Scale • Transistor hFE Test • Diode Test • Audible Continuity Test • 20MΩ Input Z Battery, Test Leads and Operating Instructions Included SPECIFICATIONS: General Display: 3 3/4 Digit LCD, 0.5” high, with polarity indicator (4,000 count) Overrange Indication: “OL” is displayed Measurement Rate: 3 times per second Operating Environment: 0°C to 50°C, <70% relative humidity Storage Environment: -20°C to 60°C, <80% relative humidity with battery removed Power: 9V carbon zinc battery (NEDA 1604) Battery Life: 150 hours typical with carbon zinc cells Low Battery Indicator: Display indicates “B” Dimensions, Weight: 3.3” wide x 6.3” long x 1” thick (84mm x 160mm x 25mm), net weight 9oz. (250g) Peak Data Hold: When the Peak Hold function is engaged, the maximum reading is shown on the display until a higher reading is recorded or power to the meter is removed DC Voltage AC Current Frequency Measurement Range Resolution Accuracy 400mV 100µV ±0.5% of rdg ±1D 4V 1mV ±0.5% of rdg ±1D 40V 10mV ±0.5% of rdg ±1D 400V 100mV ±0.5% of rdg ±1D 1000V 1V ±0.5% of rdg ±1D Input Impedance: 20MΩ on all ranges Overload Protection: 500V DC/350V AC for 15 sec. on 400mV range; 1,100V DC/800V AC on all other ranges Range Resolution Accuracy 40mA 10µA ±1.2% of rdg ±4D 400mA 100µA ±1.2% of rdg ±4D 20A 10mA ±2% of rdg ±4D Overload Protection: mA input, 0.8A/250V fuse; 20A input (unfused), up to 20A for 15 seconds Range: 4K to 4MHz (Autorange) Accuracy: ± 1% rdg ± 2D Input Sensitivity: 50mV rms Overload Protection: 500V DC/AC Resistance Logic Type: TTL Input Impedance: 120KΩ ±10K Logic Thresholds Logic 1: 2.4V, ±0.2V Logic 0: 0.7V, ±0.2V Frequency Response: 20MHz Detestable Pulse Width: 25ns, min. Overload Protection: 50V DC/AC DC Current Range Resolution Accuracy 40mA 10µA ±1% of rdg ±1D 400mA 100µA ±1% of rdg ±1D 20A 10mA ±2% of rdg ±3D Overload Protection: mA input 0.8A/250V fuse; 20A input (unfused), up to 20A for 15 seconds AC Voltage Range Resolution Accuracy 400mV 100µV ±1% of rdg ±4D 4V 1mV ±1% of rdg ±4D 40V 10mV ±1% of rdg ±4D 400V 100mV ±1% of rdg ±4D 750V 1V ±1.5% of rdg ±4D Input Impedance: 20MΩ on all ranges Overload Protection: 500V DC/350V AC for 15 sec. on 400mV range; 1,100V DC/800V AC on all other ranges Frequency Range: 50 - 500Hz 6 Range Resolution Accuracy 400Ω 0.1Ω ±1% of rdg ±3D 4KΩ 1Ω ±0.8% of rdg ±1D 40KΩ 10Ω ±0.8% of rdg ±1D 400KΩ 100Ω ±0.8% of rdg ±1D 4MΩ 1KΩ ±0.8% of rdg ±1D 40MΩ 10KΩ ±3% of rdg ±3D 400MΩ 1MΩ ±5% of rdg -10D, +4D Overload Protection: 500V DC/AC, 10 seconds Capacitance Range Resolution 4nF 1pF 40nF 10pF 400nF 100pF 4µF 1nF 40µF 10nF Test Frequency: 400Hz Test Voltage: 50mV Accuracy ±3% of rdg ±10D ±3% of rdg ±10D ±3% of rdg ±10D ±3% of rdg ±10D ±3% of rdg ±10D Logic Measurement Continuity Test Resistance Range: 400Ω Beeper Response: <50Ω Response Time: <100mSec Transistor hFE Test (PNP, NPN) Test Condition: 10µA Base Current @ 2.8V hFE Range: 0 - 1000 Diode Test Voltage: 3.2V @ 1.6mA Max 800-631-1250 • www.nteinc.com Digital Multimeter DM-59 • Perfect For Workshop and School • 10 Functions, 30 Ranges • 3 1/2 Digit LCD, 0.55” H • Audible Continuity Test • 10MΩ Input Z • Overload Protection • RF Shielded • Tilt Stand • 1-Year Limited Warranty • Frequency Counter • hFE • Capacitance • Diode Test • 20MΩ FS • 10A AC/DC • 0.5% Basic DC Accuracy Battery, Test Leads (ML-375), Spare Fuse and Operating Instructions Included SPECIFICATIONS: General Display: 3 1/2 Digit LCD, 0.55” high, with polarity Overrange Indication: “OL” is displayed Measurement Rate: 2.5 times per second Operating Environment: 0°C to 50°C, <70% relative humidity Storage Environment: -20°C to 60°C, <80% relative humidity with battery removed Power: 9V carbon zinc battery (NEDA 1604) Battery Life: 150 hours typical with carbon zinc cells Low Battery Indicator: Symbol is displayed Dimensions, Weight: 2.8” wide x 6” long x 1.5” thick (70mm x 151mm x 38mm) net weight 7oz. (200g) DC Voltage AC Current Frequency Measurement Range Resolution Accuracy 200mV 100µV ±0.5% of rdg ±1D 2V 1mV ±0.5% of rdg ± 1D 20V 10mV ±0.5% of rdg ±1D 200V 100mV ±0.5% of rdg ±1D 600V 1V ±0.5% of rdg ±1D Input Impedance: 10MΩ on all ranges Maximum Input: 600V DC or AC rms Range Resolution Accuracy 2mA 1µA ±2.0% of rdg ±4D 20mA 10µA ±2.0% of rdg ±4D 200mA 100mA ±2.0% of rdg ±4D 10A 10mA ±3.5% of rdg ±4D Overload Protection: mA input, 0.5A/250V fuse; 10A input 10A/250 fuse Range: 2kHz - 15MHz (Autorange) Accuracy: ±0.1% rdg ±1D Input Sensitivity: Trig Lo: 1 Vrms; Trig Hi: 2 Vrms Overload Protection: 500V DC or AC rms Resistance DC Current Range Resolution Accuracy 2mA 1µA ±1.0% of rdg ±1D 20mA 10µA ±1.0% of rdg ±1D 200mA 100mA ±1.0% of rdg ±1D 10A 10mA ±3.0% of rdg ±1D Overload Protection: mA input, 0.5A/250V fuse; 10A input 10A/600V fuse Range Resolution Accuracy 200Ω 0.1Ω ±0.8% of rdg ±3D 2KΩ 1Ω ±0.8% of rdg ±1D 20KΩ 10Ω ±0.8% of rdg ±1D 200KΩ 100Ω ±0.8% of rdg ±1D 2000KΩ 1KΩ ±0.8% of rdg ±1D 20MΩ 10KΩ ±3% of rdg ±3D Overload Protection: 500V DC or AC rms AC Voltage Capacitance Range Resolution Accuracy 200mV 100µV ±1.0% of rdg ±4D 2V 1mV ±1.0% of rdg ±4D 20V 10mV ±1.0% of rdg ±4D 200V 100mV ±1.0% of rdg ±4D 600V 1V ±1.9% of rdg ±4D Input Impedance: 10MΩ on all ranges Maximum Input: 600V DC or AC rms Frequency Range: 50Hz - 500Hz Range Resolution 2000pF 1pF 20nF 10pF 200nF 100pF 2µF 1nF 20µF 10nF Test Frequency: 2.5Hz Test Voltage: 3V Continuity Test (Audible) Resistance Range: 200Ω Beeper Response: <40Ω Transistor hFE Test (PNP, NPN) Test Condition: 10µA Base Current @ <3.5V hFE Range: 0 - 1000 Diode Test Voltage: 2V @ 1.6mA Max Accuracy ±2.0% of rdg ±10D ±2.0% of rdg ±10D ±2.0% of rdg ±10D ±2.0% of rdg ±10D ±2.0% of rdg ±10D 800-631-1250 • www.nteinc.com 7 Digital Multimeter DM-75 • Low Cost • Full Function General Purpose • Rotary Range Switch • 10MΩ Input Impedance, DC • Overload Protection • Pocket Size • 90-Day Limited Warranty • Diode Test • 0.7% Basic DC Accuracy • 3 1/2 Digit LCD, 0.5” H • 10A DC Battery, Test Leads and Operating Instructions Included SPECIFICATIONS: General Display: 3 1/2 Digit LCD, 0.5” high, with polarity indicator Overrange Indication: 3 least significant digits blanked Operating Environment: 0°C to 50°C, <80% relative humidity Storage Environment: -15°C to 50°C Power: 9V alkaline or carbon zinc battery Battery Life: 100 hours typical with carbon zinc cells, 200 hours typical with alkaline cells Dimensions, Weight: 2.8” wide x 5” long x 1” thick (71mm x 127mm x 25.4mm), net weight 6.1oz. (173g) DC Voltage AC Voltage Range Resolution Accuracy 200mV 0.1mV ±0.7% of rdg ±4D 2000mV 1mV ±0.7% of rdg ±2D 20V 10mV ±0.7% of rdg ±2D 200V 100mV ±0.7% of rdg ±2D 1000V 1V ±0.7% of rdg ±2D Input Impedance: 10MΩ on all ranges Range Resolution Accuracy 200V 100mV ±1.2% of rdg ±10D 750V 1V ±1.2% of rdg ±10D Overload Protection: 750V rms Frequency Range: 45Hz - 450Hz DC Current Range 200Ω 2000Ω 20KΩ 200KΩ 2000KΩ Range Resolution Accuracy 200µA 0.1µA ± 1% of rdg ± 2D 2000µA 1µA ± 1% of rdg ± 2D 20mA 10µA ± 1% of rdg ± 2D 200mA 100µA ± 1.2% of rdg ± 2D 2000mA 1mA ± 1.5% of rdg ± 2D 10A 10mA ± 1.5% of rdg ± 2D Overload Protection: mA input, 2A/250V fuse; 10A input (unfused) up to 10A for 15 seconds 8 Resistance Resolution 0.1Ω 1Ω 10Ω 100Ω 1KΩ Accuracy ±0.7% of rdg ±2D ±0.7% of rdg ±2D ±0.7% of rdg ±2D ±0.7% of rdg ±2D ±1% of rdg ±2D Diode Test Voltage: 2.8V @ 1mA 800-631-1250 • www.nteinc.com Digital Multimeter DM-78A • Heavy Duty, Ideal For Plant/ Industrial Maintenance • 10MΩ Input Z • “No Hand” Data Hold • Input Warning Beeper* • 20A AC/DC Fused • Diode Test • Instant Continuity Beeper • Overload Protection • 1-Year Limited Warranty • Water Resistant (O-Ring Seals) • Withstands 5’ Drop • Protective Holster (MH-350) • Large Display Window • 3200 Count LCD, .55” H • 65 Segment Analog Bar Graph • 0.5% Basic DC Accuracy • Auto Power Off Batteries, Test Leads (ML-375), and Operating Instructions Included SPECIFICATIONS: General Display: 3200 count LCD, 65 segment bar graph, 0.55” high, with polarity Auto Power Off: Approx. 10 min. after mode or function change Overrange Indication: “OL” is displayed Operating Environment: 0°C to 50°C, <80% relative humidity Storage Environment: -20°C to 60°C, <80% relative humidity with battery removed Temperature Coefficient: (0°C to 18°C and 28°C to 50°C), less than 0.15 x applicable accuracy specification per second Measurement Rate: Digital 2 times per second, analog 12 times per second Power: 1.5V AAA (2) alkaline or carbon zinc batteries Battery Life: 1000 hours with alkaline cells Low Battery Indicator: Symbol is displayed Fuse: 1A 240/250V Fast Dimensions, Weight: 3.3” wide x 6.9” long x 1.2” thick (84mm x 175mm x 31mm), net weight 12oz. (340g) DC Voltage AC Voltage Resistance Range Resolution Accuracy 300mV 0.1mV ±0.5% of rdg ±2D 3V 1mV ±0.5% of rdg ±2D 30V 10 mV ±0.5% of rdg ±2D 300V 100mV ±0.5% of rdg ±2D 1000V 1V ±0.5% of rdg ±2D Input Impedance: 10MΩ Overload Protection: 1100VpK (15 sec.) Range Resolution Accuracy 3V 1mV ±1.3% of rdg ±5D 30V 10mV ±1.3% of rdg ±5D 300V 100mV ±1.3% of rdg ±5D 750V 1V ±1.3% of rdg ±5D Frequency Range: 3V on 40Hz - 300Hz; 40Hz - 500Hz all others Input Impedance: 10MΩ on all ranges Overload Protection: 770V AC RMS or 1100Vpk (15 sec.) Range Resolution Accuracy (Lo-Power Ω) 300Ω 0.1Ω ±1% of rdg ±4D 3KΩ 1Ω ±0.75% of rdg ±2D 30KΩ 10Ω ±0.75% of rdg ±2D 300KΩ 100Ω ±0.75% of rdg ±2D 3MΩ 1KΩ ±1.5% of rdg ±3D 30MΩ 10KΩ ±2.5% of rdg ±5D Lo-Power Ω open circuit 1.3V Overload Protection: 600VDC or 600V AC RMS (10 sec. ) DC Current Range Resolution Accuracy 300µA 0.1µA ±1% of rdg ±2D 3mA 1µA ±1.2% of rdg ±2D 30mA 10µA ±1% of rdg ±2D 300mA 100µA ±1.2% of rdg ±2D 20A 10mA ±2% of rdg ±3D Overload Protection: µA, mA = 1A 240/250V, 20A = 13A 240/250V (readings over 10A max., 30 sec.) Voltage Drop: 200mV on 300µA, 30mA ranges; 2V all others AC Current Range Resolution Accuracy 300µA 0.1µA ±1.5% of rdg ±3D 3mA 1µA ±1.5% of rdg ±3D 30mA 10µA ±1.5% of rdg ±3D 300mA 100µA ±2% of rdg ±3D 20A 10mA ±2.5% of rdg ±5D Frequency Range: 40Hz - 500Hz Overload Protection: µA, mA = 1A 240/250V, 20A = 13A 240/250V (readings over 10A max., 30 sec.) Voltage Drop: 200mV on 300µA, 30mA ranges; 2V all others Diode Test Voltage: 3.3V @ 1.5mA max Continuity Test Beeper Response: <50Ω Response Time: Instant Delay Hold: Allows “No-Hand” data hold operation * Input Warning Beeper: Eliminates incorrect test lead placement and selector switch settings 800-631-1250 • www.nteinc.com 9 Digital Multimeter DM-80 • Heavy Duty, Ideal For Plant/Industrial Maintenance • Autoranging • 11 Functions, 39 Ranges • Frequency • Temperature • Diode Test • Audible Continuity Test • Overload Protection • 1-Year Limited Warranty • 0.3% Basic DC Accuracy • 42 Segment Bar Graph • 4000 Count LCD • Min./Max. • Data Hold • Memory • Capacitance Battery, Test Leads (ML-375), Thermocouple (TC-50P), Protective Holster and Operating Instructions Included SPECIFICATIONS: General Display: 3 3/4 Digit LCD with polarity indicator, 42 segment bar graph, .5” high Auto Power Off: 30 minutes Overrange Indication: Most significant digit blinks Operating Environment: 0°C to 40°C, <80% relative humidity Storage Environment: -20°C to 60°C, <70% relative humidity Measurement Rate: Digital 2 times per second, bargraph 20 times per second, capacitance 1 time per second Power: 9V alkaline or carbon zinc battery (NEDA 1604) Battery Life: 500 hours typical with alkaline cells Fuse: 2A/250V Dimensions, Weight: 3.25” wide x 7” long x 1.25” thick (82.6mm x 177.8mm x 31.8mm), net weight 11.5oz. (326g) DC Voltage AC Current Frequency Measurement Range Resolution Accuracy 400mV 0.1mV ±0.3% of rdg ±1D 4V 1mV ±0.3% of rdg ±1D 40V 10mV ±0.3% of rdg ±1D 400V 100mV ±0.3% of rdg ±1D 1000V 1V ±0.3% of rdg ±3D Overload Protection: 1000V pk (10 sec.) Range Resolution Accuracy 4mA 0.001mA ±2% of rdg ±5D 40mA 0.01mA ±2% of rdg ±5D 400mA 0.1mA ±2% of rdg ±5D 2000mA 1mA ±2% of rdg ±5D 10A 0.01A ±2% of rdg ±5D Frequency Range: 50Hz - 500Hz Overload Protection: mA = 2A/250V, 10A = Unfused Range 100Hz 1000Hz 10kHz 100kHz 1000kHz DC Current Range Resolution Accuracy 4mA 0.001mA ±1.5% of rdg ±2D 40mA 0.01mA ±1.5% of rdg ±2D 400mA 0.1mA ±1.5% of rdg ±2D 4000mA 1mA ±1.5% of rdg ±2D 10A 0.01A ±2% of rdg ±2D Overload Protection: mA = 2A/250V, 10A = Unfused AC Voltage Range Resolution Accuracy 4V 1mV ±1.2% of rdg ±5D 40V 10mV ±1.2% of rdg ±5D 400V 100mV ±1.2% of rdg ±5D 750V 1V ±1.2% of rdg ±5D Input Impedance: 10MΩ on all ranges Overload Protection: 1000V pk (10 sec.) 10 Resistance Range Resolution Accuracy 400Ω 0.1Ω ±1% of rdg ±2D 4KΩ 1Ω ±0.7% of rdg ±2D 40KΩ 10Ω ±0.7% of rdg ±2D 400KΩ 100Ω ±0.7% of rdg ±2D 4MΩ 1KΩ ±0.7% of rdg ±2D 40MΩ 10KΩ ±2% of rdg ±5D Overload Protection: 250V DC or peak AC,10 sec. Resolution 0.001nF 0.01nF 0.1nF 1nF 10nF Accuracy ±1% of rdg ±10D ±1% of rdg ±10D ±1% of rdg ±10D ±1% of rdg ±10D Not Specified Temperature Measurement Range: 0°F to 2000°F Resolution: 1°F Accuracy: 0°F to 225°F (±5° ±2D) 225°F to 2000°F (±3% of rdg) Diode Test: 3.2V Continuity Test (Audible) Beeper Response: <40Ω Response Time: Instantly Capacitance Range 4nF 40nF 400nF 4µF 40µF Resolution 0.001Hz 0.1Hz 1Hz 10Hz 100Hz Accuracy ±5% of rdg ±2D ±5% of rdg ±2D ±5% of rdg ±2D ±5% of rdg ±2D ±5% of rdg ±2D 800-631-1250 • www.nteinc.com Digital Capacitance Meter CX-920A • A “Must” For Trouble Shooting and Circuit Design • Measures To 20mF (20,000µF) • Portable, Battery Operated • Overrange Indicator • Rotary Range Switch • Rugged Construction • Tilt Stand • 1-Year Limited Warranty • 0.1pF to 20mF (20,000µF), 9 Ranges • 0.5% Basic Accuracy • 3 1/2 Digit LCD, 0.55” H • Zero Adjustment • Input Protected • Low Battery Indicator Battery, Test Leads (ML-920A), Spare Fuse and Operating Instructions Included SPECIFICATIONS: General Display: 3 1/2 Digit LCD, 0.55” high Overrange Indication: A “1” is displayed with the 3 least significant digits blanked Operating Environment: 0°C to 50°C, <70% relative humidity Storage Environment: -20°C to 60°C, <80% relative humidity with battery removed Temperature Coefficient: 0.1 x specified accuracy per °C, which is only applicable for the temperature range of <18°C or >28°C Power: 9V alkaline or carbon zinc battery (NEDA 1604) Battery Life: 150 hours typical with carbon zinc cells Low Battery Indicator: Symbol is displayed Dimensions, Weight: 2.8” wide x 6” long x 1.5” thick (70mm x 151mm x 38mm), net weight 7oz. (200g) Capacitance Test Voltage Range Resolution Accuracy 200pF 0.1pF ±0.5% of rdg ±1D ±0.5pF 2000pF 1pF ±0.5% of rdg ±1D 20nF (.02µF) 10pF ±0.5% of rdg ±1D 200nF (.2µF) 100pF ±0.5% of rdg ±1D 2µF 1nF ±0.5% of rdg ±1D 20µF 10nF ±0.5% of rdg ±1D 200µF 0.1µF ±0.5% of rdg ±1D 2000µF 1µF ±2% of rdg ±1D 20mF (20,000µF) 10µF ±4% of rdg ±1D Accuracy is based on an operating temperature of 23°C (73°F) at relative humidity up to 75% 3.5V peak max., “+” input terminal voltage is always higher than “–” input terminal Overload Protection 100mA/250V, fast blow fuse Zero Capacitance Adjustment Range Approx. ±20pF 800-631-1250 • www.nteinc.com 11 Digital Infrared Thermometer DIT-205 • Pen-style IR thermometer fits easily in a pocket or purse for quick and easy surface temperature measurements • Temperature Range: -27° to 428°F (-33° to 220°C) • Accuracy: ±2% of reading or ±2°C • 0.1° resolution for accurate readings • Selectable temperature units F/C • 1:1 Optics (distance-to-spot size ratio) • Emissivity preset to 0.95 • LCD display • Non-contact • Does not use a laser beam • Metal alloy case • Lithium batteries (2 LR44 included typically provide for 180 hours of continuous operation) • Low battery indication • Automatic power OFF after 15 seconds • RoHS Compliant • 1 Year Warranty • Durable pocket clip SPECIFICATIONS: General Measurement Range: - 27° to 428°F (-33° to 220°C) Ambient Operating Range: 32° to 122°F (0° to 50°C) Storage Temperature Range: -4° to 149°F (-20° to 65°C) Where can I use an infrared thermometer? Kitchen: • Temperatures of all cooking surfaces • Microwaved foods • Dishes in microwave heat differently • Baby formula bottles • Baby foods • Teflon fry pans actually become toxic at high temperatures • Appliance performance: freezer and oven temperature • Dishwasher water temperatures • Hot oil temperatures in deep fryers • Cookie sheet temperature • Crock pot accuracy • Melting chocolate • Candle making • Home beer brewing • Fondues: cheese, oil, chocolate • Serving temperatures of beer and wine • Pizza ovens Safety: • Child car seats • Bath water: especially children and infants • Check playground equipment: slides and swings • Beach sand • Benches and chair temperatures 12 Accuracy: ±2% of reading or ±2°C Resolution at -9.9°~199.9°C: 0.1° F or °C Response Time (90%): 1 second D:S: 1:1 Emissivity: Fixed 0.95 Update Frequency: 1.4Hz Dimensions: 3.25 x 0.5 inches Wave Length Response: 5-14um Weight (with battery): 2 oz Batteries: 2 LR44 (included) Battery Life: 180hr (typical) Health: • Foot temperatures for diabetics • Muscle tears and sprains • Arthritic areas • Horses: bad shoe, muscle tear, scar tissue • Livestock breeding area temperatures • Food serving quality at buffets • Damp spots where mold and mildew grow Outdoor uses: • Verify BBQ surface temperatures • Water temperatures in pools, spas and hot tubs • Lawns for heat stress and areas sprinkler missed • Outdoor fire pits and tool temperatures • Small stoke engines: mowers, snow blowers • Driveway temperature before recoating surfaces Around the home: • Doors and windows for drafts • Air conditioner air temperature • Furnace registers • Flue temperature in heating systems • Ballasts in florescent lighting • Dimmer switches for overheating • Lightbulb before unscrewing • Wood stoves flue temperature and ducts • Fireplace logs (gas burn) • Fuses and breakers for possible shorts • Room temperatures (scan walls for heat layers) • Reptile cages and environment • Aquarium water temperatures • Air conditioning: supply and return registers • Surface temperature before painting Automotive, Hobby, Racing: • Engine check - spark plugs - manifold • Air conditioning and heating • Radiator blockages • Brake temperatures overheating • Catalytic converters blockage • Tire temperatures - under/over inflated • Track temperatures match correct tires • Engine temperatures in remote control vehicles 800-631-1250 • www.nteinc.com Handheld Digital Thermometer DT-205 • Perfect For - HVAC/Industrial Maintenance - Techs - Hobbyist • Pocket Size - Light Weight • Built-In Retractable 3.5” Probe • °C or °F Switchable • ±1°C, ±2°F Accuracy • Up to 0.1° Resolution • 3.5 Digit LCD, 0.55” H • Rugged Construction • Low Battery Indicator • Overrange Indicator • 90 Day Limited Warranty Battery, Carrying Case and Operating Instructions Included DESCRIPTION: The DT-205 is a pocket-sized Digital Thermometer with a built-in thermocouple probe that retracts into the case. It possesses features of more costly instruments such as switchable Fahrenheit and Celsius scales, up to 0.1° resolution and a large easy-to-read 3 1/2 digit display. Measurement range is -50°C to 150°C and -58°F to 302°F. Ruggedly constructed and fast acting, the DT-205 is ideally suited for set up, adjustment and monitoring heating and cooling systems plus checking for heat loss. SPECIFICATIONS: General Celsius Display: 3 1/2 Digit LCD, 0.5” high. Overrange Indication: A “1” or “–1” is displayed with the 3 least significant digits blanked Measurement Rate: 3 times per second Operating Environment: 0°C to 35°C, <90% relative humidity, 35°C to 50°C <70% relative humidity Storage Environment: -40°C to 60°C, with battery removed Power: 9V alkaline or carbon zinc battery (NEDA 1604) Battery Life: 300 hours typical with carbon zinc cells Low Battery Indicator: Display indicates “Bat” Dimensions, Weight: 1.8” wide x 5.6” long x 1.1” thick (46mm x 142mm x 28mm) Net weight 5.6oz. (142g) with battery Range Resolution Accuracy -50°C to 150°C 0.1°C ±3° @ -50° to 0° ±1° @ 0° to 100° ±3° @ 100° to 150° Temperature Coefficient: <0.1 x the applicable accuracy specification per °C, from 0°C to 18°C and 28°C to 50°C Fahrenheit Range Resolution Accuracy -58°F to 302°F 1°F ±6° @ -58° to 32° ±2° @ 32° to 212° ±6° @ 212° to 302° Temperature Coefficient: <0.1 x the applicable accuracy specification per °F, from 32°F to 64.4°F to 122°F 800-631-1250 • www.nteinc.com 13 Logic Circuit Test Probes PR-21 Logic Probe/Pulse Detector • Perfect Trouble Shooting Tool • 20MHz Pulse Detector • Switch Selectable - Pulse Detection or Memory - TTL/CMOS • Audible Logic State Tones • Input Impedance 1MΩ • Detects 30ns Pulses • Operates to 20MHz • Color Coded LEDs • Circuit Powered • 90-Day Limited Warranty DESCRIPTION: The PR-21 is a versatile instrument for troubleshooting and analyzing logic circuits. Features include visual indication of pulse level and pulse presence, pulse memory, plus an audible, two-tone, logic state indicator. The probe responds to pulses as narrow as 30ns and pulse trains up to 20MHz, and is compatible with TTL, DTL, RTL, HTL, CMOS and MOS. It is also compact and light weight. Three color-coded LEDs indicate pulse presence and high/low logic states. Visual indication is complemented by audible tones of two distinctly different frequencies to distinguish the logic states easily. The PR-21 Logic Probe is a valuable servicing aid, especially when used in conjunction with the PR-31 Logic Pulsar. SPECIFICATIONS: Input Signal Frequency: 20MHz Max Minimum Detectable Pulse Width: 30ns Input Impedance: 1MΩ Operating Supply Range (Vcc): 4V DC Min., 18V DC Max. TTL Logic “1” (Hi LED) >2.3 ±0.2V DC Logic “0” (Lo LED) <0.8 ±0.2V DC CMOS Logic “1” (Hi LED) >70% Vcc ±10% Logic “0” (Lo LED) <30% Vcc ±10% 14 Maximum Allowable Supply Voltage (Vcc): ± 20V DC Power Supply Protection: ±20V DC Max. (15 sec.) Signal Input Protection: ±220V AC/DC Max. (15 sec.) Pulse Indicator Flash Time: 500ms Operating Environment: 0°C to 50°C, <80% relative humidity Storage Environment: -20°C to 65°C, <75% relative humidity Dimensions, Weight: 8 .2” long x 0.7” dia. (21cm x 1.8cm) net weight 1.6 oz. (45g) 800-631-1250 • www.nteinc.com Logic Circuit Test Probes PR-31 Logic Probe/Pulse Generator • Trouble Shooting/Design Tool • Pulse Generator • Use with Companion Logic Probe PR-21 or Scope • Compatible with Most Logic Families • Signal Injector (Square Wave) • Switchable 0.5/400Hz Pulse Rate • Sources/Sinks 100mA Pulses • External Sync Input • Circuit Powered • 90-Day Limited Warranty DESCRIPTION: The PR-31 Pulse Generator is used to inject a signal into a logic circuit without having to remove the IC or open the circuit. Using the companion PR-21 Logic Probe you can detect component failures or wiring errors. The average power of the injected signal is limited by supply voltage (Vcc) of the circuit under test, and with its short duration pulses, will not damage circuit components. The PR-31 Logic Pulsar produces a 10µs signal at a 100 mA load and can be switched to either 0.5Hz or 400Hz. It is also capable of generating a square wave equal to approximately 90% of the supply voltage (Vcc) at the square wave output terminal so that an oscilloscope can be used to observe and trace signals. The PR-31 Logic Pulsar also has an external sync input, which enables the user to synchronize the pulse output with an external signal, such as a computer clock circuit. SPECIFICATIONS: Input Signal Frequency: 20MHz Max Minimum Detectable Pulse Width: 30ns Input Impedance: 1MΩ Operating Supply Range (Vcc): 4V DC Min., 18V DC Max. TTL Logic “1” (Hi LED) >2.3 ±0.2V DC Logic “0” (Lo LED) <0.8 ±0.2V DC CMOS Logic “1” (Hi LED) >70% Vcc ±10% Logic “0” (Lo LED) <30% Vcc ±10% Maximum Allowable Supply Voltage (Vcc): ± 20V DC Power Supply Protection: ±20V DC Max. (15 sec.) Signal Input Protection: ±220V AC/DC Max. (15 sec.) Pulse Indicator Flash Time: 500ms Operating Environment: 0°C to 50°C, <80% relative humidity Storage Environment: -20°C to 65°C, <75% relative humidity Dimensions, Weight: 8.2” long x 0.7” dia. (21cm x 1.8cm) net weight 1.6 oz. (45g) Output Pulse Rate: 0.5/400Hz Output Pulse Width: 10-15µs Output Pulse Amplitude: Approx. 90% Vcc Output Current: 100mA Sink/Source Square Wave Output Current: 5mA Sink/Source Sync Input Impedance: 1MΩ Power Supply Range (Vcc): 5-15V DC Overload Protection: Power Supply 20V DC Max. (30 sec.) Sync Input 120V DC Max. (30 sec.) Test Point 35V DC Max. (30 sec.) Operating Environment: 0°C to 50°C, <80% relative humidity Storage Environment: -20°C to 65°C, <75% relative humidity Dimensions, Weight: 8 .2” long x 0.7” dia. (21cm x 1.8cm) net weight 1.4oz. (40g) 800-631-1250 • www.nteinc.com 15 Oscilloscope Probes PR-60A, PR-100, PR-200B • High Quality At Economical Prices • Compatible with Popular Scopes • Switchable X1, X10 and Ground Reference • Stable Calibration • Ground Clip Rotates 360° • Pin-Point Probe Tip • 90-Day Limited Warranty PR-200B PR-100 PR-60A PR-100 PR-200B SPECIFICATIONS: SPECIFICATIONS: SPECIFICATIONS: Switch Function Switch Function Switch Function X1: Attenuation: 1:1 Bandwidth: DC to 15MHz Input Capacitance: 45pf X10: Attenuation: 10:1 Bandwidth: DC to 60MHz Compensation Range: 10 to 35pF Input Capacitance: 15pF Input Resistance: 10MΩ, with Oscilloscope of 1MΩ Input Resistance Working Voltage: 600V (DC + peak AC) Operating Temperature: 0°C to +70°C Coaxial Cable Length: 47.24” (1200mm) X1: Attenuation: 1:1 Bandwidth: DC to 10MHz Rise Time: 35ns Input Capacitance: 75pf + Oscilloscope Input Capacitance X10: Attenuation: 10:1 Bandwidth: DC to 100MHz Rise Time: 3.5ns Compensation Range: 15 to 50pF Input Resistance: 10MΩ, with Oscilloscope of 1.0MΩ Input Resistance Input Capacitance: 11pF Reference Position: Tip Grounded via 9MΩ, Oscilloscope Input Grounded Working Voltage: 600V (DC + peak AC) Operating Temperature: 0°C to +70°C Coaxial Cable Length: 57” (1478mm) X1: Attenuation: 1:1 Bandwidth: DC to 5MHz Rise Time: 75ns Input Capacitance: 60pf + Oscilloscope Input Capacitance X10: Attenuation: 10:1 (±3%) Bandwidth: DC to 200MHz Rise Time: 1.8ns Compensation Range: 10 to 60pF Input Resistance: 1 0MΩ, with Oscilloscope of 1.0MΩ Input Resistance Input Capacitance: 14pF Reference Position: Tip Grounded via 9MΩ, Oscilloscope Input Grounded Working Voltage: 600V (DC + peak AC) Operating Temperature: 0°C to +70°C Coaxial Cable Length: 47.2” (1200mm) Accessories Supplied Accessories Supplied Ground Lead and Clip Retractable Hook IC Tip Insulating Tip BNC Adapter Trimmer Tool Ground Lead and Clip Retractable Hook IC Tip Insulating Tip BNC Adapter Trimmer Tool Replacement Tip • 60 MHz Bandwidth • 100 MHz Bandwidth Accessories Supplied Ground Lead and Clip Retractable Hook Replacement Accessories PR-200BGL - Ground Lead and Clip PR-200BSH - Retractable Hook PR-200BKT Accessory Kit: Ground Lead and Clip; IC Tip; BNC Adapter; Retractable Hook; Insulating Tip; Trimmer Tool; Replacement Tip 16 Replacement Accessories PR-200BGL - Ground Lead and Clip PR-200BSH - Retractable Hook PR-200BKT Accessory Kit: Ground Lead and Clip; IC Tip; BNC Adapter; Retractable Hook; Insulating Tip; Trimmer Tool; Replacement Tip • 200 MHz Bandwidth Replacement Accessories PR-200BGL - Ground Lead and Clip PR-200BSH - Retractable Hook PR-200BKT Accessory Kit: Ground Lead and Clip; IC Tip; BNC Adapter; Retractable Hook; Insulating Tip; Trimmer Tool; Replacement Tip 800-631-1250 • www.nteinc.com Accessories ML-370 Replacement Test Leads ML-10 • Flexible • Heavy Duty • Insulated DESCRIPTION: Meter Model No. AM-10 AM-30 FET-43 DM-37 AM-22 DM-21 DM-50 DM-59 DM-78A DM-80 DM-500 CX-920A Part No. ML-10 ML-43 Length (Nom.) 26.5 in. 43 in. ML-30 ML-375 ML-370 48 in. (Includes alligator clips) ML-375 42 in. ML-920A 13 in. ML-43 ML-920A Multimeter test leads - cross reference Meter Mfg./ ECG Model No. Repl. Meter Mfg./ ECG Model No. Repl. Meter Mfg./ ECG Model No. Repl. Meter Mfg./ ECG Model No. Repl. Meter Mfg./ ECG Model No. Repl. Meter Mfg./ ECG Model No. Repl. Meter Mfg./ ECG Model No. Repl. Meter Mfg./ ECG Model No. Repl. Amprobe Beckman/ Wavetek HD-130.......ML-370 HD-140.......ML-370 RMS225......ML-370 TECH300.......ML-43 TECH310.......ML-43 TECH320.......ML-43 TECH330.......ML-43 TECH350.....ML-370 TECH360.....ML-370 75...............ML-370 77...............ML-370 79...............ML-370 83...............ML-370 85...............ML-370 87...............ML-370 8020B ........ML-370 8021B ........ML-370 8022B.........ML-370 8024B.........ML-370 8026B.........ML-370 8050A.........ML-370 8060A.........ML-370 8062A.........ML-370 Goldstar DM-1835.....ML-370 DM-6335.....ML-370 DM-7143.....ML-370 DM-7333.....ML-370 DM-8243.....ML-370 DM-8433.....ML-370 Hitachi Philips ECG 3510...........ML-370 3525...........ML-370 3550...........ML-370 AM-10...........ML-10 AM-20...........ML-43 AM-22.........ML-375 AM-30...........ML-43 CM-30...........ML-30 CM-33.................— CX-920................— CX-920A....ML-920A DM-21.........ML-375 DM-25.................— DM-26.................— DM-27.................— DM-50.........ML-375 DM-51.................— DM-53.................— DM-55L...............— DM-59.........ML-375 DM-71.........ML-370 DM-74.........ML-370 DM-75.................— DM-76.........ML-370 DM-78.........ML-375 DM-78A.......ML-375 DM-80.........ML-375 DM-300.......ML-370 DM-305.......ML-375 DM-305A.....ML-375 DM-310.......ML-370 DM-410.......ML-370 DM-500.......ML-375 FET-43..........ML-43 DVM-634.......ML-43 DVM-636.......ML-43 DVM-638.......ML-43 DVM-642.....ML-375 DVM-6005...........— LCR-680..............— DM-6910.....ML-370 DM-7010.....ML-370 DM-8010.....ML-370 DSA-2002....ML-370 DSA-2002P.. ML-370 DSA-2003....ML-370 DSA-2007....ML-370 DSA-2007A.ML-370 DSA-2009....ML-370 SP-170B........ML-43 SP-250B........ML-43 SPR-300+...ML-370 SPR-931......ML-370 TD-2608......ML-370 TD-2608A....ML-370 AM-4A...........ML-43 AM-4B.........ML-370 AM-1200.....ML-375 AM-1280.....ML-375 B&K 213...............ML-43 340A.............ML-30 350.............ML-370 377.....................— 388HD.........ML-370 388A...........ML-375 389.............ML-375 390.............ML-375 391.............ML-375 815.............ML-375 2703...................— 2703A.........ML-370 2704...................— 2704A.........ML-370 2706...........ML-370 2707...........ML-370 2806...........ML-370 2807...........ML-370 2816...........ML-370 2817...........ML-370 2845...........ML-370 2860...........ML-375 2905...........ML-370 2906...........ML-370 2907...........ML-370 2911...........ML-370 2912...........ML-370 2940...........ML-370 2945...........ML-370 151.............ML-370 152.............ML-370 153.............ML-370 300.............ML-370 310.............ML-370 320.............ML-370 330.............ML-370 350.............ML-370 360.............ML-370 3000.............ML-43 3010.............ML-43 3010UL.........ML-43 3020.............ML-43 3020B...........ML-43 3030.............ML-43 3050...........ML-370 3060...........ML-370 4410...........ML-370 DM10..................— DM15B................— DM20L................— DM23..................— DM25L................— DM25XL..............— DM27XL..............— DM800........ML-370 DM850........ML-370 DM-10...........ML-43 DM-40.........ML-370 DM-45.........ML-370 DM-50.........ML-370 HD-100.......ML-370 HD-110.......ML-370 Extech 380165...............— 380166...............— 380168.......ML-375 308196.......ML-375 380198.......ML-375 380451.......ML-370 380650.........ML-30 380776.......ML-370 380911........ ML375 380972.......ML-370 383487.......ML-370 Fluke 10...............ML-370 11...............ML-375 12...............ML-375 21...............ML-375 23...............ML-370 25...............ML-370 27...............ML-370 29...............ML-370 37...............ML-370 45...............ML-370 70...............ML-370 73...............ML-370 Heathkit 2208.............ML-30 2311...................— 2372...................— 2374...................— 2380...........ML-375 SM-77.........ML-370 H. P. E2373A.......ML-370 E2377A.......ML-370 E2378A.......ML-370 Mercer 9120.............ML-43 9301...........ML-370 9370...........ML-370 9401...........ML-370 9702.............ML-30 Protek 301U...................— 505.............ML-375 A800.............ML-10 A802...........ML-375 A803.............ML-43 A-400............ML-43 A-420S..........ML-43 A-423............ML-43 A-423...........TC-50P A-445............ML-43 A-450............ML-43 D-901..................— D-902..........ML-370 D-906..........ML-370 D-910F........ML-370 D-910F.........TC-50P D-927..........ML-370 D-937..........ML-370 D-945 .........ML-370 D-981..........ML-370 D-981...........TC-50P D-982..........ML-370 Scope DCM-602.............— 800-631-1250 • www.nteinc.com Simpson 470.............ML-370 474.............ML-370 Soar 3025...........ML-370 3030...........ML-370 3050...........ML-370 3200...........ML-370 3210...........ML-370 3220...........ML-370 3230...........ML-370 3430...........ML-370 3450...........ML-370 3510...........ML-370 3520...........ML-370 4010...........ML-370 4020...........ML-370 4030...........ML-370 4040...........ML-370 4050...........ML-370 5025...........ML-370 5026...........ML-370 5030...........ML-370 A. W. Sperry DM-3010.....ML-370 DM-4000A...........— DM-6510.....ML-370 Tektronix DM250........ML-375 DM251........ML-375 DM253........ML-375 DM254........ML-375 DM255........ML-370 DM256........ML-370 DM257........ML-370 Triplett 50...............ML-370 3350...........ML-370 3360...........ML-370 3500...........ML-370 3550...........ML-370 3560...........ML-370 3565...........ML-370 4700...........ML-370 4750...........ML-370 4800...........ML-370 17 Distributed by: Test Equipment NTE Electronics, Inc. 44 Farrand Street, Bloomfield, NJ 07003 Phone: 973-748-5089 Fax: 973-748-6224 www.nteinc.com ® Copyright 2014 NTE Electronics, Inc. ECG® is a registered trademark of NTE Electronics, Inc EL37-01