HP U1177A

Agilent U1210 Series Handheld
Clamp Meters
Handle big currents – more safely
Data Sheet
Features
• Large clamp opening of
52 mm or 2”
• High measurement capability
of up to 1000 A for AC, DC or
AC+DC
• CAT III 1000 V/CAT IV 600 V
safety rating
• Bluetooth® wireless
connectivity (optional U1177A
Infrared (IR)-to-Bluetooth
Adapter required)
• Includes full-featured DMM
with resistance, capacitance,
frequency and temperature
functions
• High resolution measurements
– measure current as low
as 0.01 mA
• Peak hold
• Dual ranging mode – manual
and auto
• Large dual display
• Min/max recording capability
Measurements of electrical distribution cables can be challenging and
risky. For cables up to two inches in diameter, the Agilent U1210 Series
handheld clamp meters enable high-current measurements without
breaking the circuit. Unlike most clamp meters, they also include DMM
capabilities—resistance, capacitance, frequency and temperature—to
simplify troubleshooting during installation and maintenance. Best of all,
they provide an extra layer of protection with CAT IV 600V and CAT III
1000 V safety ratings.
Key Measurements
Measure current easily and
accurately
Agilent U1210 Series handheld clamp
meters come with clamp opening of
52 mm/2 inches and high current
measurement capability of up to
1000 A (AC, DC, AC+ DC). With the
large jaw size, these handhelds
simplify current measurements for
thick cables. Clamp on with the
U1210 Series and get convenience,
versatility and the ability to handle big
currents—safely.
Full-featured digital multimeter
functions
The U1210 Series handheld clamp
meters provide basic functions of a
multimeter with wide measurement
ranges to cater for a broad range of
applications (ACA, DCV, ACV, OHM,
audible continuity, diode and frequency
tests). These meters also provide
auto-ranging capability, built-in peak
hold for in-rush current measurement,
temperature and capacitance measurement capability, large backlight
display and one-hand operation.
Smooth sailing measurements
even in a distance
Making current measurements can
be strenuously demanding due to its
complexity and high current involved.
Electrical distribution rooms being
typically situated at different areas
further complicates maintenance
and troubleshooting due to the need
to commute back and forth to cross
check measurement results.
By adding the new Bluetooth
capability to your existing U1210
series handheld clamp meters,
you are able to make high current
measurements in a safer and more
convenient manner. With the U1177A
Infrared-to-Bluetooth adapter, you can
easily monitor measurements and log
data up 10-metres range across all
2
Android platform devices- an added
value for maximum efficiency and
productivity in all sorts of hard-toreach environments.
Take a Closer Look
Large jaw opening of 2 inches to
test thick current sources
Capacitance/Diode
measurement
Max or Min recording capability
Temperature and audible
continuity functions
High measurement
capability of up to 1000 A
for AC, DC or AC+DC
Large LCD display with
maximum reading of
4000 counts
Peak hold function for
in-rush current testing
Manual or auto ranging
3
General Specifications
Title
Specification
Dimension
• U1211A: 106 mm (W) X 273 mm (L) X 43 mm (H)
• U1212A and U1213A: 106 mm (W) X 260 mm (L) X 43 mm (H)
Net Weight
• U1211A: 625 grams with batteries included
• U1212A and U1213A: 525 grams with batteries included
Display
4 digits with maximum reading 4,100 counts. The 12 Segments analog bar graph and full
annunciator. Automatic polarity indication.
Battery
Standard 9 V Battery - Alkaline
Low battery indicator
Battery voltage drops below 6.0 V
Power consumption
• U1211A: 186 mVA maximum
• U1212A and U1213A: 220 mVA maximum
Battery life
60 hours (typical)
Connectivity
Wireless Bluetooth compatible
Maximum jaw opening
~2 inches
Temperature coefficient
0.12 x (specified accuracy)/°C (from 0 to 18 °C or 28 to 50 °C)
NMRR (Normal Mode Rejection Ratio)
This series has a NMRR specification of > 60 dB at 50 Hz and 60 Hz, which means a good
ability to reject the effect of AC noise in DC measurement
CMRR (Common Mode Rejection Ratio)
• U1211A and U1212A have CMRR specifications of > 60 dB at DC to 60 Hz in the ACV
function; and > 80 dB at DC, 50 Hz and 60 Hz in the DCV function.
• U1213A has a CMRR specifications of > 60 dB at DC to 60 Hz in the ACV function;
and > 120 dB at DC, 50 Hz and 60 Hz in the DCV function.
Operating temperature
–10 to 50 °C, 0 to 80 % R.H.
Storage temperature
–20 to 60 °C, 0 to 80 % R.H.
Relative Humidity (R.H.)
Maximum 80 % R.H. for temperature up to 31 °C decreasing linearly to 50 % R.H. at 50 °C
Temperature coefficient
0.1 × (specified accuracy) / °C (from 0 °C to 18 °C or 28 °C to 50 °C)
Safety compliance
EN/IEC 61010-1:2001, ANSI/UL 61010-1:2004, and CAN/CSA-C22.2 No.61010-1-04
Measurement category
CAT III 1000 V/ CAT IV 600 V
EMC compliance
•
•
•
•
Certified to IEC61326-1:2005/ EN61326-1:2006
CISPR 11:2003/ EN 55011:2007 Group 1 class A
Canada: ICES-001:2004
Australia/New Zealand: AS/NZS CISPR11:2004
4
Electrical Specifications for U1211A
Accuracy is given as ± (% of reading + number of least significant digits) at 23 °C ± 5 °C, with relative humidity less than 80 % R.H.
ACV/ ACA specifications are ac coupled, true R.M.S. and are valid from 5 % of range to 100 % of range. The crest factor may be up to
3.0 at full-scale except the 1000 V and 1000 A ranges where these are 1.5 at full scale. For non-sinusoidal waveforms, add (2 % reading +
2 % full scale) typical, for crest factors up to 3.
DC voltage
•
Range
Resolution
Accuracy
400 V
0.1 V
0.5 % + 5
1000 V
1V
0.5 % + 3
Range
Resolution
Accuracy
45~400 Hz
400 V
0.1 V
1%+5
1000 V
1V
1%+5
Overload protection
1000 V R.M.S
Input impedance: 10 MΩ (nominal)
AC voltage
•
Overload protection
1000 V R.M.S
Input impedance: 10 MΩ (nominal) in parallel with < 100 pF
Voltage (1 ms peak hold)
•
Range
Resolution
Accuracy
400 V
0.1 V
1 % + 43
1000 V
1V
1 % + 43
Overload protection
1000 V R.M.S
Specified accuracy for changes > 1 ms in duration
Diode check/audible continuity test
Range
Resolution
Accuracy
Test current
Open voltage
Diode
0.001 V
0.5 % + 2
Approximately 0.8 mA
< +3.1 V
•
Overload protection: 1000 V R.M.S. for circuits < 0.3 A of short circuit current
•
Built-in buzzer sounds when reading is below 50 mV approximately and single tone for normal forward-biased diode or semiconductor junction as
0.3 V ≤ Reading ≤ 0.8 V
Resistance
Range
Resolution
Accuracy
Test current
400 Ω
0.1 Ω
0.5 % + 3
0.8 mA
4 kΩ
0.001 kΩ
0.5 % + 3
80 µA
Notes:
1. Overload protection: 1000 V R.M.S. for circuits < 0.3 A of short circuit current
2. Maximum open voltage: < +3.1 V
3. Instant continuity: Built-in buzzer sounds when resistance is less than 10.0 Ω
4. The accuracy of 400 Ω and 4 kΩ is specified after Relative function, which is used to substrate the test lead resistance and the thermal effect
5
Electrical Specifications for U1211A (continued)
Capacitance
•
Range
Resolution
Accuracy
Overload protection
400 µF
0.1 µF
2%+4
4000 µF
1 µF
3%+4
1000 V R.M.S. for circuits
< 0.3 A of short circuit current
The accuracy is based on film capacitor or better and use Relative mode to zero residual value
AC current
Range
Resolution
Accuracy *N1
45~65 Hz
65~400 Hz
400 Hz~1 kHz
40 A
0.01 A
1.0 % + 10
1.0 % + 10
3.0 % + 10
400 A
0.1 A
1.0 % + 5
1.0 % + 5
3.0 % + 5
400~700 A
1A
1.0 % + 5
1.0 % + 5
3.0 % + 5
700~1000 A
1A
1.0 % + 5
None
None
•
Maximum overload: 1000 A R.M.S. The accuracy is specified on the symmetrical waveforms.
•
N1: The maximum verification of current and frequency product is less than 400,000 A x Hz
WARNING:
The measuring duty cycle should not exceed the following limits.
0 ~ 600 A R.M.S.
Continuous
600 ~ 700 A R.M.S.
10 minutes ON, 10 minutes OFF
700 ~ 1000 A R.M.S.
5 minutes ON, 20 minutes OFF
Current (1 ms peak hold)
•
Range
Resolution
Accuracy
40 A
0.01 A
2.0 % + 70
400 A
0.1 A
2.0 % + 43
1000 A
1A
2.0 % + 43
Specified accuracy for changes > 1 ms in duration
6
Maximum overload
1000 A R.M.S.
Electrical Specifications for U1211A (continued)
Frequency (AC coupling)
•
Range
Resolution
99.99 Hz
0.01 Hz
999.9 Hz
0.1 Hz
9.999 kHz
0.001 kHz
99.99 kHz
0.01 kHz
999.9 kHz
0.1 kHz
Accuracy
Minimum frequency
0.2 % + 3
10 Hz
Overload protection: 1000 V; < 20,000,000 V x Hz
Sensitivity
Frequency sensitivity
Range
Maximum input for specified accuracy of AC
Minimum sensitivity (R.M.S.)
40 Hz~2 kHz
10~40 Hz or 2~100 kHz
400 V
6V
6V
1000 V
20 V
30 V (< 10 kHz)
40 A
3 A (< 1 kHz)
3 A (< 1 kHz)
400 A
20 A (< 1 kHz)
20 A (< 1 kHz)
1000 A
50 A (1 kHz)
50 A (< 1 kHz)
7
Electrical Specifications for U1212A
Accuracy is given as ± (% of reading + number of least significant digits) at 23 °C ± 5 °C, with relative humidity less than 80 % R.H.
ACV/ ACA specifications are ac coupled, true R.M.S. and are valid from 5 % of range to 100 % of range. The crest factor may be up to
3.0 at full-scale except the 1000 V and 1000 A ranges where these are 1.5 at full scale. For non-sinusoidal waveforms, add (2 % reading +
2 % full scale) typical, for crest factors up to 3.
DC voltage
•
Range
Resolution
Accuracy
400 V
0.1 V
0.5 % + 3
1000 V
1V
0.5 % + 3
Range
Resolution
Accuracy
45~400 Hz
400 V
0.1 V
1%+5
1000 V
1V
1%+5
Overload protection
1000 V R.M.S
Input impedance: 10 MΩ (nominal)
AC voltage
•
Overload protection
1000 V R.M.S
Input impedance: 10 MΩ (nominal) in parallel with < 100 pF
Voltage (1 ms peak hold)
•
Range
Resolution
Accuracy
400 V
0.1 V
1 % + 43
1000 V
1V
1 % + 43
Overload protection
1000 V R.M.S
Specified accuracy for changes > 1 ms in duration
Diode check/audible continuity test
Range
Resolution
Accuracy
Test current
Open voltage
Diode
0.001 V
0.5 % + 2
Approximately 0.8 mA
< +3.1 V
•
Overload protection: 1000 V R.M.S. for circuits < 0.3 A of short circuit current
•
Built-in buzzer sounds when reading is below 50 mV approximately and single tone for normal forward-biased diode or semiconductor junction as
0.3 V ≤ Reading ≤ 0.8 V
Resistance
Range
Resolution
Accuracy
Test current
400 Ω
0.1 Ω
0.5 % + 3
0.8 mA
4 kΩ
0.001 kΩ
0.5 % + 3
80 µA
Notes:
1. Overload protection: 1000 V R.M.S. for circuits < 0.3 A of short circuit current
2. Maximum open voltage: < +3.1 V
3. Instant continuity: Built-in buzzer sounds when resistance is less than 10.0 Ω
4. The accuracy of 400 Ω and 4 kΩ is specified after Relative function, which is used to substrate the test lead resistance and the thermal effect
8
Electrical Specifications for U1212A (continued)
Capacitance
Range
Resolution
Accuracy
Overload protection
400 µF
0.1 µF
2%+4
4000 µF
1 µF
3%+4
1000 V R.M.S. for circuits
< 0.3 A of short circuit current
•
The accuracy is based on film capacitor or better and use Relative mode to zero residual value
DC current
Range
Resolution
Accuracy
40 A
0.01 A
1.5 % + 15
400 A
0.1 A
1.5 % + 3
1000 A
1A
2.0 % + 5
•
Maximum overload
1000 A R.M.S.
Use Relative mode to zero residual offset
AC current
Range
Resolution
Accuracy *N1
45~65 Hz
40 A
0.01 A
2.0 % + 10
3.0 % + 10
400 A
0.1 A
2.0 % + 5
3.0 % + 5
1000 A
1A
2.0 % + 5
3.0 % + 5
•
65 Hz~1 KHz
Maximum overload
1000 A R.M.S.
N1: The maximum verification of current and frequency product is less than 400,000 A x Hz
Current (1 ms peak hold)
Range
Resolution
Accuracy
40 A
0.01 A
2.0 % + 70
400 A
0.1 A
2.0 % + 43
1000 A
1A
2.0 % + 43
•
Maximum overload
1000 A R.M.S.
Specified accuracy for changes > 1 ms in duration
Temperature test
Thermal type
K
Range
Resolution
Accuracy
–200 ~ –40 °C
0.1 °C
1 % + 3 °C
–40 ~ 1372 °C
0.1 °C
1 % + 1 °C
–328 ~ –40 °F
0.1 °F
1 % + 6 °F
–40 ~ 2502 °F
0.1 °F
1 % + 2 °F
Notes:
1. The accuracy does not include the tolerance of the thermocouple probe, and the meter must be operational for at least one hour
2. Do not allow the temperature sensor to contact a surface that is energized above 33 V R.M.S. or 70 V DC. Such voltages will pose a shock hazard.
3. The temperature calculation is according to the standard of EN/IEC-60548-1 and NIST175
9
Electrical Specifications for U1212A (continued)
Frequency (AC coupling)
•
Range
Resolution
99.99 Hz
0.01 Hz
999.9 Hz
0.1 Hz
9.999 kHz
0.001 kHz
99.99 kHz
0.01 kHz
999.9 kHz
0.1 kHz
Accuracy
Minimum frequency
0.2 % + 3
10 Hz
Overload protection: 1000 V
Sensitivity
Frequency sensitivity
Range
Maximum input for specified accuracy of AC
Minimum sensitivity (R.M.S.)
40 Hz~2 kHz
10~40 Hz or 2~100 kHz
400 V
6V
6V
1000 V
20 V
30 V (< 10 kHz)
40 A
3 A (< 1 kHz)
3 A (< 1 kHz)
400 A
20 A (< 1 kHz)
20 A (< 1 kHz)
1000 A
50 A (1 kHz)
50 A (< 1 kHz)
10
Electrical Specifications for U1213A
Accuracy is given as ± (% of reading + number of least significant digits) at 23 °C ± 5 °C, with relative humidity less than 80 % R.H.
AC voltage, AC current, AC+DC voltage, AC+DC current specifications are ac coupled, true R.M.S. and are valid from 5 % of range to
100 % of range. The crest factor may be up to 3.0 at full-scale except the 1000 V and 1000 A ranges where these are 1.5 at full scale. For
non-sinusoidal waveforms, add (2 % reading + 2 % full scale) typical, for crest factors up to 3.
DC voltage
•
Range
Resolution
4V
0.001 V
40 V
0.01 V
400 V
0.1 V
1000 V
1V
Accuracy
0.2 % + 5
Overload protection
1000 A R.M.S.
0.5 % + 3
Input impedance: 10 MΩ (nominal)
AC voltage
•
Range
Resolution
4V
0.001 V
40 V
0.01 V
400 V
0.1 V
1000 V
1V
Accuracy
45~400 Hz
400 Hz~2 kHz
Overload protection
1.0 % + 5
2.0 % + 5
1000 V R.M.S
Accuracy
45~400 Hz
400 Hz~2 kHz
Overload protection
1.5 % + 9
2.5 % + 9
1000 V R.M.S
Input impedance: 10 MΩ (nominal) in parallel with < 100 pF
AC+DC voltage
•
Range
Resolution
4V
0.001 V
40 V
0.01 V
400 V
0.1 V
1000 V
1V
Input impedance: 10 MΩ (nominal) in parallel with < 100 pF
Voltage (1 ms peak hold)
•
Range
Resolution
4V
0.001 V
40 V
0.01 V
400 V
0.1 V
1000 V
1V
Specified accuracy for changes > 1 ms in duration
11
Accuracy
Overload protection
1.0 % + 43
1000 V R.M.S
Electrical Specifications for U1213A (continued)
Diode check/audible continuity test
Range
Resolution
Accuracy
Test current
Open voltage
Diode
0.001 V
0.5 % + 2
Approximately 0.8 mA
< +3.1 V
•
Overload protection: 1000 V R.M.S. for circuits < 0.3 A of short circuit current
•
Built-in buzzer sounds when reading is below 50 mV approximately and single tone for normal forward-biased diode or semiconductor junction as
0.3 V ≤ Reading ≤ 0.8 V
Resistance
Range
Resolution
Accuracy
Test current
400 Ω
0.1 Ω
4 kΩ
0.001 kΩ
0.8 mA
40 kΩ
0.01 kΩ
400 kΩ
0.1 kΩ
4 MΩ
0.001 MΩ
0.6 % + 3
112 nA
40 MΩ
0.01 MΩ
2.0 % + 5
112 nA
0.3 % + 3
80 µA
8 µA
727 nA
Notes:
1. Overload protection: 1000 V R.M.S. for circuits < 0.3 A of short circuit current
2. Maximum open voltage: < +3.1 V
3. Instant continuity: Built-in buzzer sounds when resistance is less than 10.0 Ω
4. The accuracy of 400 Ω and 4 kΩ is specified after Relative function, which is used to substrate the test lead resistance and the thermal effect
Capacitance
Range
•
Resolution
Accuracy
4 µF
0.001 µF
40 µF
0.01 µF
400 µF
0.1 µF
2%+4
4000 µF
1 µF
3%+4
Overload protection
1%+4
1000 V R.M.S. for circuits
< 0.3 A of short circuit current
The accuracy is based on film capacitor or better and use Relative mode to zero residual value
DC current
•
Range
Resolution
Accuracy
40 A
0.01 A
1.5 % + 15
400 A
0.1 A
1.5 % + 3
1000 A
1A
2.0 % + 5
Use Relative mode to zero residual offset
12
Maximum overload
1000 A R.M.S.
Electrical Specifications for U1213A (continued)
AC current
Range
Resolution
Accuracy *N1
45~65 Hz
40 A
0.01 A
2.0 % + 10
400 A
0.1 A
2.0 % + 5
3.0 % + 5
1000 A
1A
2.0 % + 5
3.0 % + 5
•
65 Hz~1 KHz
3.0 % + 10
Maximum overload
1000 A R.M.S.
N1: The maximum verification of current and frequency product is less than 400,000 A x Hz
AC+DC current
Range
Resolution
Accuracy
45~65 Hz
40 A
0.01 A
3.5 % + 25
4.5 % + 25
400 A
0.1 A
3.5 % + 9
4.5 % + 9
1000 A
1A
4.5 % + 9
5.0 % + 9
65 Hz~1 kHz
Maximum overload
1000 A R.M.S.
Current (1 ms peak hold)
Range
Resolution
Accuracy
40 A
0.01 A
2.0 % + 70
400 A
0.1 A
2.0 % + 43
1000 A
1A
2.0 % + 43
•
Maximum overload
1000 A R.M.S.
Specified accuracy for changes > 1 ms in duration
Temperature test
Thermal type
K
Range
Resolution
Accuracy
–200 ~ –40 °C
0.1 °C
1 % + 3 °C
–40 ~ 1372 °C
0.1 °C
1 % + 1 °C
–328 ~ –40 °F
0.1 °F
1 % + 6 °F
–40 ~ 2502 °F
0.1 °F
1 % + 2 °F
Notes:
1. The accuracy does not include the tolerance of the thermocouple probe, and the meter must be operational for at least one hour
2. Do not allow the temperature sensor to contact a surface that is energized above 33 V R.M.S. or 70 V DC. Such voltages will pose a shock hazard.
3. The temperature calculation is according to the standard of EN/IEC-60548-1 and NIST175
13
Electrical Specifications for U1213A (continued)
Frequency (AC coupling)
•
Range
Resolution
99.99 Hz
0.01 Hz
999.9 Hz
0.1 Hz
9.999 kHz
0.001 kHz
99.99 kHz
0.01 kHz
999.9 kHz
0.1 kHz
Accuracy
Minimum frequency
0.2 % + 3
10 Hz
Overload protection: 1000 V; < 20,000,000 V x Hz
Sensitivity
Frequency sensitivity
Range
Maximum input for specified accuracy of AC
Minimum sensitivity (R.M.S.)
45 Hz~2 kHz
10 Hz~200 kHz
4V
0.3 V
0.6 V
40 V
2V
3V
400 V
20 V
30 V (< 100 kHz)
1000 V
50 V
50 V (< 10 kHz)
40 A
3 A (< 1 kHz)
3 A (< 1 kHz)
400 A
20 A (< 1 kHz)
20 A (< 1 kHz)
1000 A
50 A (< 1 kHz)
50 A (< 1 kHz)
Duty cycle
Mode
Range
Accuracy of full scale
AC coupling
0.1 %~99.9 %
0.3 % per kHz + 0.3 %
Notes:
1. The accuracy for duty cycle is based on a 4 V square wave input to the DC 4 V range and maximum frequency up to 2 kHz. The duty cycle range can
be measured within 5 %~95 % as the signal frequency > 20 Hz.
14
Ordering Information
Standard shipped accessories
•
•
•
•
•
Test leads
4-mm probes
Soft carrying case
Quick Start Guide
Certificate of Calibration (CoC)
Optional accessories
U1168A
Standard test lead kit
U1162A
Alligator clips
U1175A
Soft carrying case
U1186A
K-type thermocouple and adapter
U1177A
Infrared (IR)-to-Bluetooth Adapter
Did you know?
Ensure that the clamp meter measures only one conductor at a time. Measuring
multiple conductors may cause inaccuracy in measurement reading due to vector sum of the currents flowing in the conductors.
15
www.agilent.com
www.agilent.com/find/clampmeter
myAgilent
For more information on Agilent
Technologies’ products, applications or
services, please contact your local Agilent
office. The complete list is available at:
myAgilent
www.agilent.com/find/myagilent
A personalized view into the information
most relevant to you.
www.lxistandard.org
LAN eXtensions for Instruments puts
the power of Ethernet and the Web
inside your test systems. Agilent
is a founding member of the LXI
consortium.
Agilent Channel Partners
www.agilent.com/find/channelpartners
Get the best of both worlds: Agilent’s
measurement expertise and product
breadth, combined with channel
partner convenience.
Agilent Advantage Services is committed
to your success throughout your equipment’s lifetime. To keep you competitive,
we continually invest in tools and
processes that speed up calibration and
repair and reduce your cost of ownership.
You can also use Infoline Web Services
to manage equipment and services more
effectively. By sharing our measurement
and service expertise, we help you create
the products that change our world.
www.agilent.com/find/advantageservices
Agilent Electronic Measurement Group
DEKRA Certified
ISO 9001:2008
Quality Management Sys
System
www.agilent.com/find/contactus
Americas
Canada
Brazil
Mexico
United States
(877) 894 4414
(11) 4197 3600
01800 5064 800
(800) 829 4444
Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Other AP Countries
1 800 629 485
800 810 0189
800 938 693
1 800 112 929
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 375 8100
www.agilent.com/quality
Europe & Middle East
Belgium
32 (0) 2 404 93 40
Denmark
45 45 80 12 15
Finland
358 (0) 10 855 2100
France
0825 010 700*
*0.125 €/minute
Germany
Ireland
Israel
Italy
Netherlands
Spain
Sweden
United Kingdom
49 (0) 7031 464 6333
1890 924 204
972-3-9288-504/544
39 02 92 60 8484
31 (0) 20 547 2111
34 (91) 631 3300
0200-88 22 55
44 (0) 118 927 6201
For other unlisted countries:
www.agilent.com/find/contactus
Revised: October 11, 2012
Product specifications and descriptions
in this document subject to change
without notice.
Bluetooth and the Bluetooth logo are registered
trademarks owned by Bluetooth SIG, Inc., U.S.A.
and licensed to Agilent Technologies, Inc.
© Agilent Technologies, Inc. 2012
Published in USA, October 31, 2012
5990-5083EN