DC-AC INVERTER UNIT

DC-AC INVERTER UNIT
PS-DA0211-069(S) (12 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC/AC inverter is developed for dual lamps.
Optimized for Chi Mei Display: G150X1-L01
APPLICABLE LCD:
6.4 to 15 inches double lamps
Lamp voltage 580 Vrms
Lamp current 2 x 7.5 mArms
Lamp Start Up Voltage 1.500 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Open lamp detection
Regulated
Wide input range 10.4~ 13.2 Vdc
Dimming function
Specil fus Bourns SF1206 Series 2A
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
140 x 24 x 14 mm
Q2
C3
R18
C12
CAUTION
?
? ?
Q11
R8
C10
R9
R7
R5
R4
L2
T1
CN3
C4
C5
R2
CN1
Q12
R20
R3
!
CAUTION
?
? ?
CN2
1
F1
D4
D3
DA0211-
D1
CN1
D2
1
Q1
C6
R21
C8
R15
T2
R6
CN3
3.2Ø X2
PIN 1
PIN 1
C2
REV:1.0
A0
!
LxWxH
R1
DIMENSIONS :
-10°C ~ +65°C
-40°C ~ +85°C
95 %RH max
1
C1
CN2
L1
PIN 1
Unit : mm
Weight :39,8 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2 + CN3
Input side CN1:
Pin No. Symbols
Vin
CN 1-1
GND
CN 1-2
Vbr
CN 1-3
GND
CN 1-4
Vrmt
CN 1-5
Qty.
1
1
2
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-SM3
SM02(8.0)B-BHS-1-TB
Note
t=1m m
JST or equal
JST or equal
Output side CN2 + CN3:
Pin No.
Symbols
Ratings
VHIGH1
580Vrm s (7.5m Arm s )
CN 2-1
N.C.
CN 2-2
VLOW
0Vdc
CN 2-3
Ratings
12 Vdc
0 ~ 5.0 Vdc
0 ~ 0.4 = OFF / 2.5 ~ Vin = ON
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 2.3.1, 21st May 2014
DC-AC INVERTER UNIT
PS-DA0211-069(S) (12 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No load Shutdown
Iout
Iout
Iin
F
Vopen
Tsd
Note 1 :
Vin (V)
12±1.2
12±0.6
12±1.2
12±1.2
11.4
12±1.2
Conditions
Vrmt
Tu (°C)
(V)
5±0.25 -10 ~ +65
5±0.25 -10 ~ +65
5±0.25 -10 ~ +65
5±0.25 -10 ~ +65
5±0.25 -10 ~ +65
5±0.25 -10 ~ +65
Specification
Min.
Typ.
Max.
7.0
2.5
44.5
1.300
1.0
7.5
3.0
0.93
52
1.500
-
8.0
3.5
1.4
59.5
1.700
-
Unit
Note
mArms
mArms
Adc
kHz
Vrms
sec
Vbr = 0 Vdc
Vbr = 5.0 Vdc
wit hout load
Please keep a minimum of 2mm clearance in all directions between inverter high voltage areas
and any conductors.
TEST CIRCUIT :
SW 1
Operation of unit
a
Operation
b
Non operation
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 2.3.1, 21st May 2014