DC-AC INVERTER UNIT - Power

DC-AC INVERTER UNIT
PS-DA0211-01(S) (12 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for dual lamps.
INPUT VOLTAGE:
12 Vdc
APPLICABLE LCD:
6.4 to 15 inches double lamp type
Lamp Voltage 800 Vrms
Lamp Current 2 x 7.5 mArms
Lamp Start Up Voltage 1.500 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Open Lamp Detection
Regulated
Wide Input range 9.6 ~ 14.4 Vdc
Dimming Function
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
140 x 24 x 15 mm
3.2Ø X2
PIN 1
PIN 1
Q2
C3
R18
C12
CAUTION
?
? ?
C10
Q11
R8
R6
R9
R7
R5
R4
L2
T1
CN3
C4
C5
R2
CN1
Q12
R20
R3
!
CAUTION
?
? ?
CN2
1
F1
D4
D3
DA0211-
D1
CN1
D2
1
Q1
C6
R21
C8
R15
T2
C2
CN3
REV:1.0
A0
!
LxWxH
R1
DIMENSIONS :
0°C ~ +50°C
-40°C ~ +85°C
95 %RH max
1
C1
CN2
L1
PIN 1
Unit : mm
Weight :39,8 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2 + CN3
Qty.
1
1
2
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-SM3
SM02(8.0)B-BHS-1-TB
Note
t=1mm
JST or equal
JST or equal
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.9.2, 2nd September 2010
DC-AC INVERTER UNIT
PS-DA0211-01(S) (12 W DUAL OUTPUTS)
Input side CN1:
Pin No. Symbols
Vin
CN 1-1
GND
CN 1-2
Vbr
CN 1-3
GND
CN 1-4
Output side CN2:
Pin No.
Symbols
Vhigh
CN 2-1
Vlow
CN 2-2
Ratings
12 Vdc
Ratings
800 Vrms (7.5 mArms)
(GND)
0 ~ 4.2 Vdc
Vrm t
CN 1-5
(PRELIMINARY INFORMATION)
Output side CN3:
0 ~ 0.4 = OFF / 3 ~ Vin = ON
Pin No.
CN 3-1
CN 3-2
Symbols
Vhigh
Vlow
Ratings
800 Vrm s (7.5 m Arm s )
(GND)
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No load Shutdown
Note 1 :
Vin (V)
Vbr (V)
Iout
Iout
Iin
F
Vopen
12±1.2
12±0.6
12±1.2
12±1.2
11.4
Ts d
12±1.2
Specification
Unit
Tu (°C)
Min.
Typ.
Max.
0.0
4.2
0.0
0.0
0.0
0
0
0
0
0
7.0
2.5
44.5
1.300
7.5
3.0
0.93
52
1.500
8.0
3.5
1.4
59.5
1.700
m Arm s
m Arm s
Adc
kHz
Vrm s
0.0
0 ~ +50
1.0
-
-
s ec
~ +50
~ +50
~ +50
~ +50
~ +50
Note
wit hout load
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
TEST CIRCUIT :
F
Vin
12 V
A
1000:1
PROBE
F
V
~
Vopen
Iin
CN1-1
SW 1
Operation of unit
a
Operation
b
Non operation
SW3
V
CN2-1
CN1-2
CN1-3
CL1
RL1
A
~
T1
Vbr
0 ~ 4.2 Vdc
CN2-2
SW4
Iout1
SW5
CN1-4
CN3-1
Vrmt
0.4 / 3 Vdc
V
b
CL2
RL2
a
SW1
CN1-5
CN3-2
SW6
A
~
Iout2
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800