COA - Power Mate Technology Co., LTD

Issue Date:
2003-06-10
Amendment 2
2003-09-29
Report Reference #
E193009-A1-UL-1
UL 60950
Safety of information technology equipment
Test item description .......................: DC to DC Converter
Trademark ........................................: Power Mate or P-DUKE
Model and/or type reference ............: DU1P0-XSYZ, DU1P0-XDYZ (X=05, 12, 15, 24, B, C, D, E; Y=05, 12,
15; Z=N or blank)
General Product Information:
CD1.0
Additional Information
CD1.1
1.Reforced insulation for Models DU1P0-XDYN and DU1P0-XSYN based on Nominal AC Mains
Supply Voltage 300 Vrms."
2.Electrical Ratings:
Model
I/P (DC)
I/P (mA) O/P (DC) O/P (mA)
DU1P0-05S05
4.5 - 5.5 V or 5V
298mA
5V
200mA
DU1P0-BS05
DU1P0-05S12,
4.5 - 5.5 V or 5V
269mA
12 V
83mA
DU1P0-BS12
DU1P0-05S15,
4.5 - 5.5 V or 5V
272mA
15 V
67mA
DU1P0-BS15
DU1P0-12S05,
10.8 - 13.2 V or 12V
121mA
5V
200mA
DU1P0-CS05
DU1P0-12S12,
10.8 - 13.2 V or 12V
111mA
12 V
83mA
DU1P0-CS12
DU1P0-12S15,
10.8 - 13.2 V or 12V
112mA 15 V
67mA
DU1P0-CS15
DU1P0-15S05,
13.5 - 16.5 V or 15V
97mA
5V
200mA
DU1P0-DS05
DU1P0-15S12,
13.5 - 16.5 V or 15V
89mA 12 V
83mA
DU1P0-DS12
DU1P0-15S15,
13.5 - 16.5 V or 15V
89mA
15 V
67mA
DU1P0-DS15
DU1P0-24S05,
21.6 - 26.4 V or 24V
62mA
5V
200mA
DU1P0-ES05
DU1P0-24S12,
21.6 - 26.4 V or 24V
58mA
12 V
83mA
DU1P0-ES12
DU1P0-24S15,
21.6 - 26.4 V or 24V
55mA
± 15 V
33mA
DU1P0-ES15
DU1P0-05S05N,
4.5 - 5.5 V or 5V
298mA
5V
200mA
DU1P0-BS05N
DU1P0-05S12N,
4.5 - 5.5 V or 5V
269mA
12 V
83mA
DU1P0-BS12N
DU1P0-05S15N,
4.5 - 5.5 V or 5V
272mA
15 V
67mA
DU1P0-BS15N
DU1P0-12S05N,
10.8 - 13.2 V or 12V
121mA 5 V
200mA
DU1P0-CS05N
DU1P0-12S12N,
10.8 - 13.2 V or 12V
111mA
12 V
83mA
DU1P0-CS12N
DU1P0-12S15N,
10.8 - 13.2 V or 12V
112mA
15 V
67mA
DU1P0-CS15N
TRF No.: 1950__F
Underwriters Laboratories Inc.
TRF originator: FIMKO
Issue Date:
2003-06-10
Amendment 2
2003-09-29
DU1P0-15S05N,
DU1P0-DS05N
DU1P0-15S12N,
DU1P0-DS12N
DU1P0-15S15N,
DU1P0-DS15N
DU1P0-24S05N,
DU1P0-ES05N
DU1P0-24S12N,
DU1P0-ES12N
DU1P0-24S15N,
DU1P0-ES15N
DU1P0-05D05,
DU1P0-BD05
DU1P0-05D12,
DU1P0-BD12
DU1P0-05D15,
DU1P0-BD15
DU1P0-12D05,
DU1P0-CD05
DU1P0-12D12,
DU1P0-CD12
DU1P0-12D15,
DU1P0-CD15
DU1P0-15D05,
DU1P0-DD05
DU1P0-15D12,
DU1P0-DD12
DU1P0-15D15,
DU1P0-DD15
DU1P0-24D05,
DU1P0-ED05
DU1P0-24D12,
DU1P0-ED12
DU1P0-24D15,
DU1P0-ED15
DU1P0-05D05N,
DU1P0-BD05N
DU1P0-05D12N,
DU1P0-BD12N
DU1P0-05D15N,
DU1P0-BD15N
DU1P0-12D05N,
DU1P0-CD05N
DU1P0-12D12N,
DU1P0-CD12N
DU1P0-12D15N,
DU1P0-CD15N
DU1P0-15D05N,
DU1P0-DD05N
DU1P0-15D12N,
DU1P0-DD12N
TRF No.: 1950__F
Report Reference #
13.5 - 16.5 V or 15V
97mA
E193009-A1-UL-1
5V
200mA
13.5 - 16.5 V or 15V
89mA
12 V
83mA
13.5 - 16.5 V or 15V
89mA
15 V
67mA
21.6 - 26.4 V or 24V
62mA
5V
200mA
21.6 - 26.4 V or 24V
58mA
12 V
83mA
21.6 - 26.4 V or 24V
55mA
± 15 V
33mA
4.5 - 5.5 V or 5V
295mA
±5V
100mA
4.5 - 5.5 V or 5V
273mA
± 12 V
42mA
4.5 - 5.5 V or 5V
268mA
± 15 V
33mA
10.8 - 13.2 V or 12V
119mA
±5V
100mA
10.8 - 13.2 V or 12V
111mA
± 12 V
42mA
10.8 - 13.2 V or 12V
109mA
± 15 V
33mA
13.5 - 16.5 V or 15V
95mA
±5V
100mA
13.5 - 16.5 V or 15V
88mA
± 12 V
42mA
13.5 - 16.5 V or 15V
87mA
± 15 V
33mA
21.6 - 26.4 V or 24V
61mA
±5V
100mA
21.6 - 26.4 V or 24V
57mA
± 12 V
42mA
21.6 - 26.4 V or 24V
57mA
15 V
67mA
4.5 - 5.5 V or 5V
295mA
±5V
100mA
4.5 - 5.5 V or 5V
273mA
± 12 V
42mA
4.5 - 5.5 V or 5V
268mA
± 15 V
33mA
10.8 - 13.2 V or 12V
119mA
±5V
100mA
10.8 - 13.2 V or 12V
111mA
± 12 V
42mA
10.8 - 13.2 V or 12V
109mA
± 15 V
33mA
13.5 - 16.5 V or 15V
95mA
±5V
100mA
13.5 - 16.5 V or 15V
88mA
± 12 V
42mA
Underwriters Laboratories Inc.
TRF originator: FIMKO
Issue Date:
2003-06-10
Amendment 2
2003-09-29
DU1P0-15D15N,
DU1P0-DD15N
DU1P0-24D05N,
DU1P0-ED05N
DU1P0-24D12N,
DU1P0-ED12N
DU1P0-24D15N,
DU1P0-ED15N
Report Reference #
E193009-A1-UL-1
13.5 - 16.5 V or 15V
87mA
± 15 V
33mA
21.6 - 26.4 V or 24V
61mA
±5V
100mA
21.6 - 26.4 V or 24V
57mA
± 12 V
42mA
21.6 - 26.4 V or 24V
57mA
15 V
67mA
CF1.0
Engineering Conditions of Acceptability
CF1.1
For use only in or with complete equipment where the acceptability of the combination is
determined by Underwriters Laboratories Inc.
When installed in an end-product, consideration must be given to the following:
CF1.5
The following secondary output circuits are
SELV:
All output
CF1.6
The following secondary output circuits are at
hazardous energy levels
All output
CF1.11
The power supply terminals and/or connectors
are
Suitable for factory wiring only
CF1.13
The investigated Pollution Degree is
2
CF1.19
The following end-product enclosures are
required
Electrical, Fire
CF2.0
The Model DU1P0-XSY and DU1P0-XDY are
-intended to be connected to isolated secondary
circuit which is separated from primary circuit by
Reinforced or Double insulation.
CF2.1
All secondary output circuits are SELV only if
-circuit meet the limits of Sub-Clause 2.24 in the
event of a single failure of any component and
insulation of secondary circuit to which it is
connected.
CF2.2
The humidity test will conduct in end product.
TRF No.: 1950__F
--
Underwriters Laboratories Inc.
TRF originator: FIMKO