COA

Issue Date:
2007-08-21
Page 3 of 53
Report Reference #
E193009-A13-UL-1
SPECIFIC TECHNICAL CRITERIA
UL 60950-1, First Edition
Information technology equipment - SafetyPart 1: General Requirements
Report Reference No ........................: E193009-A13-UL-1
Compiled by .....................................: Steven Huang
Reviewed by ....................................: Yasli Tsai
Date of issue ....................................: 2007-08-21
Standards .........................................: UL 60950-1, 1st Edition, 2006-07-07 (Information Technology
Equipment - Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07 (Information
Technology Equipment - Safety - Part 1: General Requirements)
Test procedure .................................: Component Recognition
Non-standard test method ...............: N/A
Test item description .......................: DC-DC Converter
Trademark ........................................: None
Model and/or type reference ............: See Miscellaneous for details.
Rating(s) ...........................................: See Miscellaneous for details.
Particulars: test item vs. test requirements
Equipment mobility .................................................... : for building-in
Operating condition ................................................... : continuous
Mains supply tolerance (%) ....................................... : No direct connection
Tested for IT power systems ..................................... : No
IT testing, phase-phase voltage (V) .......................... : N/A
Class of equipment ................................................... : Special Application - Functional Earthing
Mass of equipment (kg) ............................................ : 0.06 kg Max.
Protection against ingress of water ........................... : IP X0
Possible test case verdicts:
- test case does not apply to the test object ............. : N / A
- test object does meet the requirement ................... : Pass
- test object does not meet the requirement ............. : Fail (acceptable only if a corresponding, less stringent
national requirement is "Pass")
Underwriters Laboratories Inc.
Issue Date:
2007-08-21
Page 4 of 53
Report Reference #
E193009-A13-UL-1
GENERAL PRODUCT INFORMATION:
CA1.0
Report Summary
CA1.1
N/A
CB1.0
Product Description
CB1.1
DC-DC Converter intended for used in Information Technology Equipments and consists of
electronic components mounted on PWB, filled with Epoxy and housed with metal enclosure..
Functional insulation is provided between input and output circuit.
The equipment shall be supplied from DC source that provides reinforced insulation to AC mains.
Seperation to components at hazardous voltage has to be evaluated on final system.
CC1.0
Model Differences
CC1.1
All models are similar to each other except for electric rating and component rating, circuit diagram,
PWB layout, and source of source of transformer.
Models FEC60 series are similar to each other except for electric rating, Transformer specification.
Models FEC40-24S3P3W, FEC40-24S05W, FEC40-48S3P3W, FEC40-48S05W are similar to
each other except for electric rating, Transformer specification.
Models FEC40-24S12W, FEC40-24S15W, FEC40-48S12W, FEC40-48S15W are similar to each
other except for electric rating, Transformer specification.
Models FEC40-xDzW (where x = 24 or 48, z = 12 or 15) are similar to each other except for electric
rating, Transformer specification.
CF1.0
Engineering Conditions of Acceptability
CF1.1
For use only in or with complete equipment where the acceptability of the combination is
determined by Underwriters Laboratories Inc.
When installed in an end-product, consideration must be given to the following:
CF1.5
The following secondary output circuits are SELV: All outputs.
CF1.7
The following secondary output circuits are at non-hazardous energy levels: All outputs.
CF1.11
The power supply terminals and/or connectors are: Suitable for factory wiring only
CF1.13
The investigated Pollution Degree is: 2
CF1.19
The following end-product enclosures are required: Mechanical, Fire, Electrical
CF2.0
The component is considered as functional insulation and intended to be installed in isolated
secondary circuit which is seperated from primary circuit by Reinforce or Double insulation,
additional tests of Humidity Test should be considered in the end product.
CF2.1
The DC-DC Converter is intended for use with power source provided with overcurrent protective
device rated not higher than F3.15A, 250Vac.
Underwriters Laboratories Inc.
Issue Date:
2007-08-21
Page 1 of 2
Report Reference #
Enclosure
Miscellaneous
Supplement Id
7-01
Description
Model designation and rating
Underwriters Laboratories Inc.
E193009-A13-UL-1