FEC40W SERIES DC-DC CONVERTER 4 : 1 ULTRA WIDE INPUT RANGE UP TO 40Watts FEATURES APPLICATIONS • 1600VDC INPUT TO OUTPUT ISOLATION • STANDARD 2.00 X 2.00 X 0.40 INCH • SIX-SIDED CONTINUOUS SHIELD • UL60950-1, EN60950-1, & IEC60950-1 SAFETY APPROVALS • CE MARKED • COMPLIANT TO RoHS II & REACH 1600VDC ISOLATION REMOTE CONTROL UVP • WIRELESS NETWORK • TELECOM/DATACOM • INDUSTRY CONTROL SYSTEM • DISTRIBUTED POWER ARCHITECTURES • SEMICONDUCTOR EQUIPMENT OCP SCP OVP OTP TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25 Model Number FEC40-24S3P3W FEC40-24S05W FEC40-24S12W FEC40-24S15W FEC40-24D12W FEC40-24D15W FEC40-48S3P3W FEC40-48S05W FEC40-48S12W FEC40-48S15W FEC40-48D12W FEC40-48D15W Input Range Output Voltage VDC VDC 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 9 ~ 36 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 18 ~ 75 3.3 5 12 15 ±12 ±15 3.3 5 12 15 ±12 ±15 Output Current @Full Load Min. Load (1) mA 0 0 50 50 ±65 ±50 0 0 50 50 ±65 ±60 Full Load A 10 8 3.33 2.67 ±1.67 ±1.33 10 8 3.33 2.67 ±1.67 ±1.33 otherwise noted Input Current @ No Load Efficiency Maximum Capacitor Load (2) mA % µF 75 95 50 50 60 70 55 60 30 25 30 30 87 88 87 87 86 86 87 89 87 88 87 86 25750 13600 2360 1510 ±1200 ±750 25750 13600 2360 1510 ±1200 ±750 PART NUMBER STRUCTURE FEC40 - 48 Series Name Input Voltage (VDC) 24: 9~36 48: 18~75 S Output Quantity S: Single D: Dual 1 05 Output Voltage (VDC) 3P3: 3.3 05: 5 12: 12 15: 15 12: ±12 15: ±15 W Input Range 4:1 www.PDUKE.com N HS Remote Control Option Assembly Option : Positive logic N: Negative logic : No Assembly Option HS: Heat-sink HC: Heat-sink & Clamp 2015/2/26 FEC40W INPUT SPECIFICATIONS Parameter Conditions Operating input voltage range 24Vin(nom) 48Vin(nom) Input reflected ripple current Start up voltage Constant resistive load Input surge voltage 100 ms, max. Input filter Remote ON/OFF Referred to –Vin pin OUTPUT SPECIFICATIONS Parameter Load regulation Min. Load to Full Load Cross regulation Voltage adjustability (3) Ripple and noise Asymmetrical load 25%/100% FL Single Dual Dual 20MHz bandwidth Single Dual Case grounding Isolation resistance Isolation capacitance Switching frequency Safety approvals Case material Base material Potting material Weight MTBF 2 VDC -0.5 Min. 1 minute VDC VDC Typ. ms VDC mA mA Max. Unit -1.0 -0.2 +1.0 +0.2 % -0.5 -1.0 -5.0 -10 +0.5 +1.0 +5.0 +10 3.3Vout, 5Vout 12Vout, 15Vout 12Vout 15Vout 50 75 120 150 % % % % mVp-p +0.02 250 3.9 6.2 15 18 3.3Vout 5Vout 12Vout 15Vout % of Iout rated mAp-p 20 20 50 100 Pi type Open or 3 ~ 12VDC Short or 0 ~ 1.2VDC Short or 0 ~ 1.2VDC Open or 3 ~ 12VDC +0.5 10 5 -0.02 25% load step change Zener diode clamp GENERAL SPECIFICATIONS Parameter Isolation voltage Unit 36 75 8 16 Conditions Low Line to High Line at Full Load Over load protection Short circuit protection Max. 24 48 20 9 18 Positive logic DC-DC ON (Standard) DC-DC OFF Negative logic DC-DC ON (Option) DC-DC OFF Input current of Ctrl pin Remote off 24Vin(nom) input current 48Vin(nom) Voltage accuracy Line regulation Temperature coefficient Transient response recovery time Over voltage protection Typ. 9 18 24Vin(nom) 48Vin(nom) 24Vin(nom) 48Vin(nom) Power up Remote ON/OFF 24Vin(nom) 48Vin(nom) Shutdown voltage Start up time Min. %/℃ µs VDC 150 % Continuous, automatics recovery Conditions Input to Output Input (Output) to Case 500VDC MIL-HDBK-217F, Full load www.PDUKE.com Min. Typ. Max. Unit 1600 VDC 1600 Connect case to –Vin with decoupling Y Cap 1 GΩ 2500 pF 270 300 330 kHz UL60950-1 EN60950-1 IEC60950-1 Nickel-coated copper FR4 PCB Epoxy (UL94 V-0) 60g (2.11oz) 6.617 x 105 hrs 2015/2/26 FEC40W ENVIRONMENTAL SPECIFICATIONS Parameter Conditions Operating ambient temperature Maximum case temperature Over temperature protection Storage temperature range Thermal impedance Min. Without derating With derating Typ. -40 +50 Max. Unit +50 +105 +105 +110 -55 Vertical direction by natural convection (20LFM) Without heat-sink With heat-sink Thermal shock Vibration Relative humidity +125 9.2 7.6 /W MIL-STD-810F MIL-STD-810F 5% to 95% RH EMC SPECIFICATIONS Parameter EMI (4) ESD Radiated immunity Fast transient (5) Surge (5) Conducted immunity Conditions EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 Level Air ± 8kV and Contact ± 6kV 10 V/m ±2kV ±1kV 10 Vr.m.s Class A, Class B Perf. Criteria A Perf. Criteria A Perf. Criteria B Perf. Criteria A Perf. Criteria A Note: 1. 2. 3. 4. 5. The output requires a minimum loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices, however they may not meet all listed specification. Test by minimum input and constant resistive load. For the single output: Maximum output deviation is 10% inclusive of remote sense and trim. If remote sense is not being used, the +Sense should be connected to its corresponding +Vout and likewise the -Sense should be connected to its corresponding -Vout. The standard modules meet EN55022 Class A and Class B with external components. For further information, please contact with P-DUKE. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5. The filter capacitor Power Mate suggest: Nippon chemi-con KY series, 220µF/100V. CAUTION: This power module is not internally fused. An input line fuse must always be used. CHARACTERISTIC CURVE 3 FEC40-48S05W Derating Curve FEC40-48S05W Derating Curve With Heat-sink FEC40-48S05W Efficiency vs. Input Voltage FEC40-48S05W Efficiency vs. Output Load www.PDUKE.com 2015/2/26 FEC40W MECHANICAL DRAWING PIN CONNECTION PIN 1 2 3 4 5 6 7 8 SINGLE +Vin -Vin Ctrl -Sense (3) +Sense (3) +Vout -Vout Trim DUAL +Vin -Vin Ctrl +Vout Common Common -Vout Trim EXTERNAL OUTPUT TRIMMING Output can be externally trimmed by using the method shown below. ( ) for dual output trim. TRIM UP 4(7) TRIM DOWN 8(8) RU 8(8) RD 5(4) 1. All dimensions in inch (mm) 2. Tolerance :x.xx±0.02 (x.x±0.5) x.xxx±0.01 (x.xx±0.25) 3. Pin pitch tolerance ±0.01 (0.25) 4. Pin dimension tolerance ±0.004(0.1) 4 www.PDUKE.com 2015/2/26