TECHNICAL SPECIFICATION All specifications are typical at nominal input, full load and 25
Model
Number
FEC40-24S3P3W
FEC40-24S05W
FEC40-24S12W
FEC40-24S15W
FEC40-24D12W
FEC40-24D15W
FEC40-48S3P3W
FEC40-48S05W
FEC40-48S12W
FEC40-48S15W
FEC40-48D12W
FEC40-48D15W
Input Range
Output
Voltage
VDC
VDC
9 ~ 36
9 ~ 36
9 ~ 36
9 ~ 36
9 ~ 36
9 ~ 36
18 ~ 75
18 ~ 75
18 ~ 75
18 ~ 75
18 ~ 75
18 ~ 75
3.3
5
12
15
±12
±15
3.3
5
12
15
±12
±15
Output Current
@Full Load
Min. Load (1)
mA
0
0
50
50
±65
±50
0
0
50
50
±65
±60
Full Load
A
10
8
3.33
2.67
±1.67
±1.33
10
8
3.33
2.67
±1.67
±1.33
otherwise noted
Input Current
@ No Load
Efficiency
Maximum
Capacitor Load (2)
mA
%
µF
75
95
50
50
60
70
55
60
30
25
30
30
87
88
87
87
86
86
87
89
87
88
87
86
25750
13600
2360
1510
±1200
±750
25750
13600
2360
1510
±1200
±750
PART NUMBER STRUCTURE
FEC40 - 48
Series Name
Input
Voltage
(VDC)
24: 9~36
48: 18~75
S
Output
Quantity
S: Single
D: Dual
1
05
Output
Voltage
(VDC)
3P3: 3.3
05: 5
12: 12
15: 15
12: ±12
15: ±15
W Input
Range
4:1
www.PDUKE.com
N
HS
Remote Control
Option
Assembly Option
: Positive logic
N: Negative logic
: No Assembly Option
HS: Heat-sink
HC: Heat-sink & Clamp
2015/2/26
FEC40W
INPUT SPECIFICATIONS
Parameter
Conditions
Operating input voltage range
24Vin(nom)
48Vin(nom)
Input reflected ripple current
Start up voltage
Constant resistive load
Input surge voltage
100 ms, max.
Input filter
Remote ON/OFF
Referred to –Vin pin
OUTPUT SPECIFICATIONS
Parameter
Load regulation
Min. Load to Full Load
Cross regulation
Voltage adjustability (3)
Ripple and noise
Asymmetrical load 25%/100% FL
Single
Dual
Dual
20MHz bandwidth
Single
Dual
Case grounding
Isolation resistance
Isolation capacitance
Switching frequency
Safety approvals
Case material
Base material
Potting material
Weight
MTBF
2
VDC
-0.5
Min.
1 minute
VDC
VDC
Typ.
ms
VDC
mA
mA
Max.
Unit
-1.0
-0.2
+1.0
+0.2
%
-0.5
-1.0
-5.0
-10
+0.5
+1.0
+5.0
+10
3.3Vout, 5Vout
12Vout, 15Vout
12Vout
15Vout
50
75
120
150
%
%
%
%
mVp-p
+0.02
250
3.9
6.2
15
18
3.3Vout
5Vout
12Vout
15Vout
% of Iout rated
mAp-p
20
20
50
100
Pi type
Open or 3 ~ 12VDC
Short or 0 ~ 1.2VDC
Short or 0 ~ 1.2VDC
Open or 3 ~ 12VDC
+0.5
10
5
-0.02
25% load step change
Zener diode clamp
GENERAL SPECIFICATIONS
Parameter
Isolation voltage
Unit
36
75
8
16
Conditions
Low Line to High Line at Full Load
Over load protection
Short circuit protection
Max.
24
48
20
9
18
Positive logic
DC-DC ON
(Standard)
DC-DC OFF
Negative logic
DC-DC ON
(Option)
DC-DC OFF
Input current of Ctrl pin
Remote off
24Vin(nom)
input current
48Vin(nom)
Voltage accuracy
Line regulation
Temperature coefficient
Transient response recovery time
Over voltage protection
Typ.
9
18
24Vin(nom)
48Vin(nom)
24Vin(nom)
48Vin(nom)
Power up
Remote ON/OFF
24Vin(nom)
48Vin(nom)
Shutdown voltage
Start up time
Min.
%/℃
µs
VDC
150
%
Continuous, automatics recovery
Conditions
Input to Output
Input (Output) to Case
500VDC
MIL-HDBK-217F, Full load
www.PDUKE.com
Min.
Typ.
Max.
Unit
1600
VDC
1600
Connect case to –Vin with decoupling Y Cap
1
GΩ
2500
pF
270
300
330
kHz
UL60950-1
EN60950-1
IEC60950-1
Nickel-coated copper
FR4 PCB
Epoxy (UL94 V-0)
60g (2.11oz)
6.617 x 105 hrs
2015/2/26
FEC40W
ENVIRONMENTAL SPECIFICATIONS
Parameter
Conditions
Operating ambient temperature
Maximum case temperature
Over temperature protection
Storage temperature range
Thermal impedance
Min.
Without derating
With derating
Typ.
-40
+50
Max.
Unit
+50
+105
+105
+110
-55
Vertical direction by natural convection (20LFM)
Without heat-sink
With heat-sink
Thermal shock
Vibration
Relative humidity
+125
9.2
7.6
/W
MIL-STD-810F
MIL-STD-810F
5% to 95% RH
EMC SPECIFICATIONS
Parameter
EMI (4)
ESD
Radiated immunity
Fast transient (5)
Surge (5)
Conducted immunity
Conditions
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Level
Air ± 8kV and Contact ± 6kV
10 V/m
±2kV
±1kV
10 Vr.m.s
Class A, Class B
Perf. Criteria A
Perf. Criteria A
Perf. Criteria B
Perf. Criteria A
Perf. Criteria A
Note:
1.
2.
3.
4.
5.
The output requires a minimum loading on the output to maintain specified regulation. Operation under no-load condition will not damage these
devices, however they may not meet all listed specification.
Test by minimum input and constant resistive load.
For the single output: Maximum output deviation is 10% inclusive of remote sense and trim. If remote sense is not being used, the +Sense
should be connected to its corresponding +Vout and likewise the -Sense should be connected to its corresponding -Vout.
The standard modules meet EN55022 Class A and Class B with external components. For further information, please contact with P-DUKE.
An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5. The filter capacitor Power Mate suggest:
Nippon chemi-con KY series, 220µF/100V.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
CHARACTERISTIC CURVE
3
FEC40-48S05W Derating Curve
FEC40-48S05W Derating Curve With Heat-sink
FEC40-48S05W Efficiency vs. Input Voltage
FEC40-48S05W Efficiency vs. Output Load
www.PDUKE.com
2015/2/26
FEC40W
MECHANICAL DRAWING
PIN CONNECTION
PIN
1
2
3
4
5
6
7
8
SINGLE
+Vin
-Vin
Ctrl
-Sense (3)
+Sense (3)
+Vout
-Vout
Trim
DUAL
+Vin
-Vin
Ctrl
+Vout
Common
Common
-Vout
Trim
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed by
using the method shown below.
( ) for dual output trim.
TRIM UP
4(7)
TRIM DOWN
8(8)
RU
8(8)
RD
5(4)
1. All dimensions in inch (mm)
2. Tolerance :x.xx±0.02 (x.x±0.5)
x.xxx±0.01 (x.xx±0.25)
3. Pin pitch tolerance ±0.01 (0.25)
4. Pin dimension tolerance ±0.004(0.1)
4
www.PDUKE.com
2015/2/26