TU425 Series UL Certificate

Issue Date:
2014-01-24
Page 1 of 16
Report Reference #
E135803-A74-UL
2014-08-13
UL TEST REPORT AND PROCEDURE
Standard:
Certification Type:
CCN:
UL 60950-1, 2nd Edition, 2011-12-19 (Information Technology
Equipment - Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-07, 2nd Edition, 2011-12 (Information
Technology Equipment - Safety - Part 1: General Requirements)
Component Recognition
QQGQ2, QQGQ8 (Power Supplies for Information Technology
Equipment Including Electrical Business Equipment)
Product:
Model:
Power Supply
AU425SXXYWW, AU300SXXYWW
Where A can be T or L, XX represents output voltage which may be
any number from 12 to 56, Y can be A-Z or blank (for Class I
construction), WW may be any number from 00 to 99 or blank,
designates additional configurations indicating non-safety related
options.
Rating:
Input: 100-240 Vac, 50-60 Hz, 4.5A
Output:
For AU425SXXYWW and AU300SXXYWW with convection cooled,
total max. 300W
Main output: 12 Vdc/22.0 A to 23.9Vdc/11.05A, 24Vdc/11.9A to
56Vdc/5.1A
Standby output: 5Vdc/2.0A
Fan output: 12Vdc/0.5A
For AU425SXXYWW
with airflow of Min. 32CFM(200LFM), total max. 425W
Main output: 12 Vdc/32.2 A to 23.9Vdc/16.15A, 24Vdc/16.8A to 56
Vdc/7.2A
Standby output: 5Vdc/2.0A
Fan output: 12Vdc/1.0A
Applicant Name and Address:
SL POWER ELECTRONICS CORP
BLDG A
6050 KING DR
VENTURA CA 93003
UNITED STATES
This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the
above referenced Standards. The products have been found to comply with the requirements covering the category and the products are
judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on
such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the FollowUp Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up
Service under the indicated Test Procedure.
The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety.
Copyright © 2014
Issue Date:
2014-01-24
Page 2 of 16
Report Reference #
E135803-A74-UL
2014-08-13
UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific
Technical Criteria through to the end of the Conditions of Acceptability.
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL.
Prepared by:
Scholl Zhang
Reviewed by: Vonty Zhang
Copyright © 2014
Issue Date:
2014-01-24
Page 3 of 16
Report Reference #
E135803-A74-UL
2014-08-13
Supporting Documentation
The following documents located at the beginning of this Procedure supplement the requirements of this Test
Report:
A. Authorization - The Authorization page may include additional Factory Identification Code markings.
B. Generic Inspection Instructions i. Part AC details important information which may be applicable to products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of this Test Report.
ii. Part AE details any requirements which may be applicable to all products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of each Test Report.
iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical
standard used to investigate these products. Products are permitted to bear only the Certification
Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.
Product Description
Electric components mounted on min.V-1 PWB, Open frame power supply designed for building-in to an ITE
end-product.
Model Differences
The power supplies in the AU425SXXYWW and AU300SXXYWW are similar to each other except for output
ratings and secondary winding of power transformer.
AU425SXXYWW and AU300SXXYWW are similar to each other in construction except for the output ratings
and the additional cooling system required for AU425SXXYWW.
Each model has two constructions A and B. They are similar to each other except for limited components in
the primary and secondary circuits, which have the impact on the power supply functionality. Refer to Safety
Component List for the differences regarding the safety impact.
Marking plate representative of all models.
Technical Considerations

Equipment mobility : for building-in

Connection to the mains : evaluated in end product

Operating condition : continuous

Access location : operator accessible

Over voltage category (OVC) : OVC II

Mains supply tolerance (%) or absolute mains supply values : +10%, -10%

Tested for IT power systems : No

IT testing, phase-phase voltage (V) : N/A

Class of equipment : Class I (earthed)

Considered current rating of protective device as part of the building installation (A) : 20A

Pollution degree (PD) : PD 2

IP protection class : IP X0

Altitude of operation (m) : 5000 m
Issue Date:
2014-01-24
Page 4 of 16
Report Reference #
E135803-A74-UL
2014-08-13

Altitude of test laboratory (m) : less than 2000 meters

Mass of equipment (kg) : Max.0.663

The product was submitted and evaluated for use at the maximum ambient temperature (Tma)
permitted by the manufacturer’s specification of: 50°C

The means of connection to the mains supply is: Pluggable A

The product is intended for use on the following power systems: TN

The product was investigated to the following additional standards: EN 60950-1:2006 + A11:2009 +
A1:2010 + A12:2011 (which includes all European national differences, including those specified in
this test report)., IEC 60664-1: 1992 table A.2. The Clearances and Creepage Distances have
additionally been assessed for suitability up to 5,000m elevation.

The following accessible locations (with circuit/schematic designation) are within a limited current
circuit: C326 secondary

The following are available from the Applicant upon request: Installation (Safety) Instructions /
Manual, Schematic Diagrams
Engineering Conditions of Acceptability
For use only in or with complete equipment where the acceptability of the combination is determined by UL
LLC. When installed in an end-product, consideration must be given to the following:

The following Production-Line tests are conducted for this product: Electric Strength

The end-product Electric Strength Test is to be based upon a maximum working voltage of: PrimarySELV: 364 Vrms, 604 Vpk, Primary-Earthed Dead Metal: 363 Vrms, 580 Vpk

The following secondary output circuits are SELV: Output,

The following secondary output circuits are at hazardous energy levels: Main secondary output.,

The following secondary output circuits are at non-hazardous energy levels: 12 Vdc Fan and the
5Vsb Aux.,

The following secondary output circuits are Limited Current Circuits: C326 secondary

The following output terminals were referenced to earth during performance testing: output return

The power supply terminals and/or connectors are: Suitable for factory wiring only., Not investigated
for field wiring.

The maximum investigated branch circuit rating is: 20 A

The investigated Pollution Degree is: 2

Proper bonding to the end-product main protective earthing termination is: Required

An investigation of the protective bonding terminals has: Not been conducted

The following magnetic devices (e.g. transformers or inductor) are provided with an OBJY2 insulation
system with the indicated rating greater than Class A (105°C): Transformers (T300) and (T201)
employ Class F (155).

The following end-product enclosures are required: Electrical, Mechanical and Fire

The maximum continuous power supply output (Watts) relied on forced air cooling from: external
airflow of 200 LFM.

The following "External and/or Internal force Air Cooling" configurations were employed as an
element of this investigation: , , Tunnel Method (for 200 LFM simulation): See Miscellaneous
Enclosure Id 7-02 for details.

The chassis must be bonded to protective earth in the end product. Using the earth terminal for the
end product protective earthing is not recommended and a separate dedicated bonding conductor
Issue Date:
2014-01-24
Page 5 of 16
Report Reference #
E135803-A74-UL
2014-08-13
and suitable termination should be used to connect the chassis to the end product protective earth.
Additional Information
N/A
Additional Standards
The product fulfills the requirements of: IEC 60950-1:2005 + A1:2009, EN 60950-1:2006 + A11:2009 +
A1:2010 + A12:2011
Markings and instructions
Clause Title
Power rating - Company
identification
Power rating -
Marking or Instruction Details
Listee's or Recognized company's name, Trade Name, Trademark or File
Number
Model Number
Model
Power rating Ratings
Fuses - Non-operator
access/soldered-in
fuses
Warning to service
personnel
Ratings (voltage, frequency/dc, current)
Unambiguous reference to service documentation for instructions for
replacement of fuses replaceable only by service personnel
"CAUTION: Double pole/neutral fusing"
Special Instructions to UL Representative
Inspect the transformer(s) listed in table "Electric Strength Test Special Constructions" per AA1.1 (C). When
the tests are conducted at other location, inspect test record and specification sheet provided by the
component manufacturer. Verify the specification sheet indicates 100% routine test specified in BD1.1 is
conducted at the component manufacturer. The test record noted above shall be submitted to the
manufacturer from transformer manufacturer. The test record can be in the form of a actual test record. A
stamp or sticker on the transformer or other method verifying the routine test is being completed on 100%
production is also acceptable.
Issue Date:
2014-01-24
Page 6 of 16
Report Reference #
E135803-A74-UL
2014-08-13
Production-Line Testing Requirements
Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for
further information.
Model
Component
All Models
Transformers
T300, T201
Removable
Parts
Test probe location
--
Primary to Secondary
V
rms
300
0
V dc
Test Time,
s
4242
1s
Earthing Continuity Test Exemptions - This test is not required for the following models:
All models.
Electric Strength Test Exemptions - This test is not required for the following models:
Electric Strength Test Component Exemptions - The following solid-state components may be
disconnected from the remainder of the circuitry during the performance of this test:
Sample and Test Specifics for Follow-Up Tests at UL
Model
N/A
Component
Material
Test
Sample(s)
Test
Specifics