NEC Express5800/R120e-1M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC Express5800 server. January 28, 2015 Revision 6.0 NEC Corporation SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M Contents TECHNICAL SPECIFICATION ........................................................................................ 3 Key Features .......................................................................................................................................... 3 Specification .......................................................................................................................................... 3 EXTERNAL VIEWS ......................................................................................................... 8 Front and Rear Views ........................................................................................................................... 8 Dimensions (mm) .................................................................................................................................. 9 CONFIGURATION DIAGRAM ....................................................................................... 10 Expansion Slots .................................................................................................................................. 10 SERVER CONFIGURATION ......................................................................................... 11 1 2 3 4 5 6 7 8 Base Models ................................................................................................................................. 11 Processors and Heat Sink .......................................................................................................... 11 Memory ......................................................................................................................................... 13 3.1 Memory Configuration........................................................................................................ 13 3.2 Other than Windows server 2008 Standard ...................................................................... 13 3.3 Windows Server 2008 Standard ........................................................................................ 14 Internal Hard Disk Drives ............................................................................................................ 18 4.1 RAID Configuration ............................................................................................................ 18 4.2 Internal Drive Configuration ............................................................................................... 19 Optical Drive ................................................................................................................................. 28 PCI Card ........................................................................................................................................ 29 6.1 Network Interface Controller .............................................................................................. 29 6.2 InfiniBand ........................................................................................................................... 31 6.3 PCIe SSD Adapter ............................................................................................................. 32 6.4 External Storage Controller ............................................................................................... 32 6.5 Serial Port Adapter ............................................................................................................. 33 Other Add-in Components .......................................................................................................... 34 7.1 Power Supply ..................................................................................................................... 34 7.2 Trusted Platform Module Kit .............................................................................................. 34 7.3 Internal Flash Memory ....................................................................................................... 34 7.4 Flash FDD .......................................................................................................................... 34 7.5 Front Bezel ......................................................................................................................... 35 Add-on Components ................................................................................................................... 36 8.1 17-inch LCD Console Drawer ............................................................................................ 36 8.2 KVM Switch ........................................................................................................................ 36 8.3 Cable Management Arm .................................................................................................... 37 8.4 Server Management License ............................................................................................. 37 REFERENCES............................................................................................................... 38 Server Management ............................................................................................................................ 38 OS Support Matrix for PCI Cards and Embedded Controllers ....................................................... 39 Supported PCI Cards and Installable Slots ...................................................................................... 40 Copyright Notice and Liability Disclaimer ........................................................................................ 41 REVISION HISTORY ..................................................................................................... 42 NEC Corporation Revision 6.0 – January 28, 2015 2 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M Technical Specification Key Features High performance with the latest Intel® Xeon® processor E5-2600 v2 Product Family Up to 1.5 TB of high speed DDR3 memory High energy efficiency with power capping feature and 80 PLUS® Platinum power supply Full manageability by integrated EXPRESSSCOPE Engine 3 Specification (1 / 3) Model R120e-1M Part Number Processor N8100-2073F Intel® Xeon® Intel® Xeon® Intel® Xeon® Intel® Xeon® processor processor processor processor E5-2609 v2 E5-2620 v2 E5-2630 v2 E5-2630L v2 2.50GHz 2.10 GHz 2.60 GHz 2.40 GHz 1 or 2 10 MB 15 MB 4C-4T 6C-12T Intel® C602-J Chipset DDR3-1333 ECC Unbuffered Low Power DIMM, DDR3-1600 ECC Registered Low Power DIMM, DDR3-1333 ECC Load Reduced DIMM, DDR3-1600 ECC Load Reduced DIMM 0 GB 1.5 TB (24 x 64 GB) ECC, x4 SDDC, Memory Mirroring, Memory Lockstep, Memory Sparing 0 GB SAS HDD: 9.6 TB (8 x 1.2 TB) SATA HDD: 8 TB (8 x 1 TB) SAS SSD: 3.2 TB (8 x 400 GB) SATA : 3Gb/s and 6Gb/s (Integrated) SAS: 6Gb/s (Optional) SATA : RAID 0/1/5/6/10/50/60 (Optional) SAS : RAID 0/1/5/6/10/50/60 (Optional) Supported Optional 1 6 or 8 with optional drive cage Total: 4 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 3.0 x8 (x16 connector) 1 PCIe 3.0 x8 (x8 connector) dedicated RAID slot 1 PCIe 3.0 x8 (x8 connector) flexible integrated NIC slot Integrated in Server Management Controller (32MB) 1 1280 x 1024 / 16.7M 2 x VGA (15-pin mini D-sub, 1 x front, 1 x rear) 1 x Serial (9-pin mini D-sub, RS232-C, Serial A, 1 x rear) 9 x USB2.0 (2 x front, 4 x rear, 3 x internal) 2 x 1000BASE-T LAN connector (RJ-45, 2 x rear) 1 x Management LAN connector (RJ-45, 1 x rear) EXPRESSSCOPE Engine 3 Type Clock speed Number of Processors Cache Cores and Threads Chipset Memory Type Standard Capacity Maximum Capacity Memory protection Internal Storage Standard Capacity Maximum Capacity Disk Controller RAID Expansion Slots Video Interfaces Server Management NEC Corporation Hot Plug Optical Disk Drive Optical Drive Bays Disk Drive Bays Standard Controller (VRAM) Resolution / Color Revision 6.0 – January 28, 2015 3 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M Model R120e-1M Redundant Fan Redundant Power Supply Power Supply Standard, non-hot plug Optional, hot plug 1-2 x 450 Watt or 800 Watt 80 PLUS® Platinum certified hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz 275 VA 277 VA 277 VA 277 VA / 273 Watt / 275 Watt / 275 Watt / 276 Watt 375 VA 411 VA 479 VA 427 VA / 373 Watt / 409 Watt / 476 Watt / 424 Watt 48.1 dB 48.1 dB 48.1 dB 48.1 dB 53.7 dB 53.7 dB 53.7 dB 52.4 dB Power Consumption (Max. Config, Idling) (Max. Config, Operating) Max. Config, Idling Max. Config, Operating Acoustical Noise (Sound Pressure 2 Level) Dimensions (W x D x H ) Weight (Minimum / Maximum) Temperature, Relative Humidity (non-condensing) 439.8 x 722.0 x 43.4 mm / 17.3 x 28.4 x 1.7 in (1U) 15.2 kg / 23.0 kg, 33.51 lbs. / 50.71 lbs. Operating: 10° to 40° C / 50° to 104° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% FCC, RCM, CE, UL, CB, BSMI, KC, CCC, BIS, RoHS, WEEE Microsoft® Windows Server® 2008 Standard Microsoft® Windows Server® 2008 Enterprise Microsoft® Windows Server® 2008 Standard (x64) Microsoft® Windows Server® 2008 Enterprise (x64) Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter 3 Microsoft® Windows Server® 2012 R2 Standard 3 Microsoft® Windows Server® 2012 R2 Datacenter 4 Red Hat Enterprise Linux 5.9 or later (x86) 4 Red Hat Enterprise Linux 5.9 or later (x86_64) 4 Red Hat Enterprise Linux 6.4 or later (x86) 4 Red Hat Enterprise Linux 6.4 or later (x86_64) 4 Red Hat Enterprise Linux 7.0 or later VMware ESXi 5.0 Update 2 VMware ESXi 5.1 Update 1 VMware ESXi 5.5 VMware ESX™i 5.5 Update 1 Regulatory and Safety Operating Systems 1 2 3 4 Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured at the bystander positions in accordance with ISO 7779. The actual value may vary by the operating environment. For Windows Server 2012 R2 installation, download the driver kit from the following website and install it after OS installation http://www.nec.com/en/global/prod/express/download/ For Linux support, contact your sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html (2 / 3) Model Part Number Processor R120e-1M Type Clock speed Number of Processors Cache Cores and Threads Chipset NEC Corporation N8100-2073F Intel® Xeon® Intel® Xeon® processor processor E5-2637 v2 E5-2640 v2 3.50 GHz 2 GHz 1 or 2 15 MB 20 MB 4C-8T 8C-16T Intel® C602-J Chipset Revision 6.0 – January 28, 2015 Intel® Xeon® processor E5-2650 v2 2.60 GHz Intel® Xeon® processor E5-2660 v2 2.20 GHz 25MB 10C-20T 4 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M Model Memory R120e-1M Type Standard Capacity Maximum Capacity Memory protection Internal Storage Standard Capacity Maximum Capacity Disk Controller RAID Expansion Slots Video Hot Plug Optical Disk Drive Optical Drive Bays Disk Drive Bays Standard Controller (VRAM) Resolution / Color Interfaces Server Management Redundant Fan Redundant Power Supply Power Supply Power Consumption (Max. Config, Idling) (Max. Config, Operating) Max. Config, Idling Max. Config, Operating Acoustical Noise (Sound Pressure 3 Level) Dimensions (W x D x H ) Weight (Minimum / Maximum) Temperature, Relative Humidity (non-condensing) Regulatory and Safety Operating Systems NEC Corporation DDR3-1600 ECC Unbuffered Low Power DIMM DDR3-1600 ECC Registered Low Power DIMM 1 DDR3-1866 ECC Registered DIMM DDR3-1600 ECC Load Reduced DIMM DDR3-1333 ECC Load Reduced DIMM 0 GB 1.5 TB (24 x 64 GB) ECC, x4 SDDC, Memory Mirroring, Memory Lockstep, Memory Sparing 0 GB SAS HDD: 9.6 TB (8 x 1.2 TB) SATA HDD: 8 TB (8 x 1 TB) SAS SSD: 3.2 TB (8 x 400 GB) SATA : 3Gb/s and 6Gb/s (Integrated) SAS: 6Gb/s (Optional) SATA : RAID 0/1/5/6/10/50/60 (Optional) SAS : RAID 0/1/5/6/10/50/60 (Optional) Supported Optional 1 6 or 8 with optional drive cage Total: 4 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 3.0 x8 (x16 connector) 1 PCIe 3.0 x8 (x8 connector) dedicated RAID slot 1 PCIe 3.0 x8 (x8 connector) flexible integrated NIC slot Integrated in Server Management Controller (32MB) 2 1280 x 1024 / 16.7M 2 x VGA (15-pin mini D-sub, 1 x front, 1 x rear) 1 x Serial (9-pin mini D-sub, RS232-C, Serial A, 1 x rear) 9 x USB2.0 (2 x front, 4 x rear, 3 x internal) 2 x 1000BASE-T LAN connector (RJ-45, 2 x rear) 1 x Management LAN connector (RJ-45, 1 x rear) EXPRESSSCOPE Engine 3 Standard, non-hot plug Optional, hot plug 1-2 x 450 Watt or 800 Watt 80 PLUS® Platinum certified hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz 279 VA 292 VA 286 VA 288 VA / 277 Watt / 290 Watt / 284 Watt / 286 Watt 493 VA 506 VA 548 VA 542 VA / 490 Watt / 503 Watt / 545 Watt / 538 Watt 48.1 dB 48.1 dB 48.1 dB 48.1 dB 59.6 dB 53.7 dB 53.7dB 53.7 dB 439.8 x 722.0 x 43.4 mm / 17.3 x 28.4 x 1.7 in (1U) 15.2 kg / 23.0 kg, 33.51 lbs. / 50.71 lbs. 4 4 Operating: 10° to 40° C / 50° to 104° F , 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% FCC, RCM, CE, UL, CB, BSMI, KC, CCC, BIS, RoHS, WEEE 5 Microsoft® Windows Server® 2008 Standard 5 Microsoft® Windows Server® 2008 Enterprise Microsoft® Windows Server® 2008 Standard (x64) Microsoft® Windows Server® 2008 Enterprise (x64) Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise Revision 6.0 – January 28, 2015 5 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M Model R120e-1M Operating Systems (Cont.) Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter 6 Microsoft® Windows Server® 2012 R2 Standard 6 Microsoft® Windows Server® 2012 R2 Datacenter Red Hat 4 Enterprise Linux 5.9 or later (x86) 4 Red Hat Enterprise Linux 5.9 or later (x86_64) 57 Red Hat Enterprise Linux 6.4 or later (x86) 7 Red Hat Enterprise Linux 6.4 or later (x86_64) 4 Red Hat Enterprise Linux 7.0 or later VMware ESXi 5.0 Update 2 VMware ESXi 5.1 Update 1 VMware ESXi 5.5 VMware ESX™i 5.5 Update 1 1 2 3 4 5 6 7 Not supported on Xeon® processor E5-2637 v2 systems Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured at the bystander positions in accordance with ISO 7779. The actual value may vary by the operating environment. Operable up to 35°C (95°F) when installing Xeon processor E5-2637 v2. Not supported on Xeon® processor E5-2660 v2 systems For Windows Server 2012 R2 installation, download the driver kit from the following website and install it after OS installation http://www.nec.com/en/global/prod/express/download/ For Linux support, contact your sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html (3 / 3) Model Part Number Processor R120e-1M Type Clock speed Number of Processors Cache Cores and Threads Chipset Memory Type Standard Capacity Maximum Capacity Memory protection Internal Storage Standard Capacity Maximum Capacity Disk Controller RAID Hot Plug Optical Disk Drive NEC Corporation N8100-2073F Intel® Xeon® Intel® Xeon® Intel® Xeon® Intel® Xeon® processor processor processor processor E5-2670 v2 E5-2690 v2 E5-2695 v2 E5-2697 v2 2.50 GHz 3 GHz 2.40 GHz 2.70 GHz 1 to 2 25 MB 30 MB 10C-20T 12C-24T Intel® C602-J Chipset DDR3-1333 ECC Unbuffered Low Power DIMM, DDR3-1600 ECC Registered Low Power DIMM, DDR3-1333 ECC Load Reduced DIMM, DDR3-1600 ECC Load Reduced DIMM 0 GB 1.5 TB (24 x 64 GB) ECC, x4 SDDC, Memory Mirroring, Memory Lockstep, Memory Sparing 0 GB SAS HDD: 9.6 TB (8 x 1.2 TB) SATA HDD: 8 TB (8 x 1 TB) SAS SSD: 3.2 TB (8 x 400 GB) SATA : 3Gb/s and 6Gb/s (Integrated) SAS: 6Gb/s (Optional) SATA : RAID 0/1/5/6/10/50/60 (Optional) SAS : RAID 0/1/5/6/10/50/60 (Optional) Supported Optional Revision 6.0 – January 28, 2015 6 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M Model Internal Storage (Cont.) Expansion Slots Video R120e-1M Optical Drive Bays Disk Drive Bays Standard Controller (VRAM) Resolution / Color Interfaces Server Management Redundant Fan Redundant Power Supply Power Supply Power Consumption (Max. Config, Idling) (Max. Config, Operating) Max. Config, Idling Max. Config, Operating Acoustical Noise (Sound Pressure 2 Level) Dimensions (W x D x H ) Weight (Minimum / Maximum) Temperature, Relative Humidity (non-condensing) Regulatory and Safety Operating Systems 1 2 3 4 5 1 6 or 8 with optional drive cage Total: 4 slots available 1 PCIe 3.0 x16 (x16 connector) 1 PCIe 3.0 x8 (x16 connector) 1 PCIe 3.0 x8 (x8 connector) dedicated RAID slot 1 PCIe 3.0 x8 (x8 connector) flexible integrated NIC slot Integrated in Server Management Controller (32MB) 1 1280 x 1024 / 16.7M 2 x VGA (15-pin mini D-sub, 1 x front, 1 x rear) 1 x Serial (9-pin mini D-sub, RS232-C, Serial A, 1 x rear) 9 x USB2.0 (2 x front, 4 x rear, 3 x internal) 2 x 1000BASE-T LAN connector (RJ-45, 2 x rear) 1 x Management LAN connector (RJ-45, 1 x rear) EXPRESSSCOPE Engine 3 Standard, non-hot plug Optional, hot plug 1-2 x 450 Watt or 800 Watt 80 PLUS® Platinum certified hot plug PSU 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz 280 VA 278 VA 290 VA 292 VA / 278 Watt / 276 Watt / 288 Watt / 290 Watt 563 VA 674 VA 644 VA 687 VA / 559 Watt / 669 Watt / 640 Watt / 682 Watt 48.1 dB 48.1 dB 48.1dB 48.1dB 53.7 dB 59.6 dB 53.7 dB 59.6 dB 439.8 x 722.0 x 43.4 mm / 17.3 x 28.4 x 1.7 in (1U) 15.2 kg / 23.0 kg, 33.51 lbs. / 50.71 lbs. 3 Operating: 10° to 40° C / 50° to 104° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% FCC, RCM, CE, UL, CB, BSMI, KC, CCC, BIS, RoHS, WEEE Microsoft® Windows Server® 2008 Standard (x64) Microsoft® Windows Server® 2008 Enterprise (x64) Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter 4 Microsoft® Windows Server® 2012 R2 Standard 4 Microsoft® Windows Server® 2012 R2 Datacenter 5 Red Hat Enterprise Linux 5.9 or later (x86_64) 5 Red Hat Enterprise Linux 6.4 or later (x86_64) 4 Red Hat Enterprise Linux 7.0 or later VMware ESXi 5.0 Update 2 VMware ESXi 5.1 Update 1 VMware ESXi 5.5 VMware ESX™i 5.5 Update 1 Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. Noise emission was measured at the bystander positions in accordance with ISO 7779. The actual value may vary by the operating environment. Operable up to 35°C (95°F) when installing Xeon processor E5-2690 v2 or E5-2697 v2. For Windows Server 2012 R2 installation, download the driver kit from the following website and install it after OS installation http://www.nec.com/en/global/prod/express/download/ For Linux support, contact your sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html NEC Corporation Revision 6.0 – January 28, 2015 7 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M External Views Front and Rear Views Front View B C D FH J K L M N O A EG I P Q Legend A. B. C. D. E. F. G. H. I. Drive Bays Pull-out Tab USB Connectors Data LAN 1 Activity LED Data LAN 2 Activity LED Data LAN 3 Activity LED Data LAN 4 Activity LED Hard Drive Activity LED System Status LED NEC Corporation J. K. L. M. N. O. P. Q BMC RESET Switch DUMP Switch RESET Switch UID LED Button/LED POWER Button/LED VGA Connector 2.5-inch Drive Cage (optional, 2 bays) Optical Drive Bay (blank cover) Revision 6.0 – January 28, 2015 8 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M Rear View A C D E F B G H I J K LM N O Legend A. B. C. D. E. F. G. H. PCI Slot (Full Height) PCI Slot (Low Profile) Power Supply AC Inlet AC Power LED USB Connectors Data LAN Connectors Management LAN Connector I. J. K. L. M. N. O. Serial Port Connector VGA Connector Dump (NMI) Switch UID LED Button/LED AC Power LED LAN Riser (blank cover) Additional PS Slot (blank cover) Dimensions (mm) 908.2 * 44.4 818.9 43.4 479.7 722.0 482.4 35.0 439.8 43.1 * With extension bracket of inner rails (when using cable management arm) NEC Corporation Revision 6.0 – January 28, 2015 9 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M Configuration Diagram CHASSIS REAR Legend: LAN Riser Mandatory components CPU 2 6x DIMM Slots #1C PCIe 3.0 2x DIMM 6x DIMM slots Cooling Fan Optical Drive Bay Riser CPU 1 6x DIMM Slots 2 x BBU area 2x HDD / 1 x ODD 2.5-inch HDD Cage Power Supply 2 PCI Riser PCIe 3.0 #1B 6x HDD Cooling Fan 6x DIMM Slots PSU 2 CHASSIS TOP PCIe 3.0 RAID Power Supply 1 PSU 1 CHASSIS FRONT Standard Components Expansion Slots #1B #1A #1C #1D Legend #1A #1B #1C #1D NEC Corporation PCIe 3.0 x8, x8 connector, for a dedicated RAID controller PCIe 3.0 x16, x16 connector, Full-height, up to 220 mm length PCIe 3.0 x8, x16 connector, Low-profile, up to 220 mm length PCIe 3.0 x8, x8 connector, for a flexible integrated NIC (LAN Riser) Revision 6.0 – January 28, 2015 10 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M Server Configuration 1 Base Models Product Name / Description Part Number NEC Express5800/R120e-1M Server no processor, no RAM, no HDD, no ODD, no PSU, no front bezel Including: 2.5-inch Drive Cage, EXPRESSBUILDER DVD N8100-2073F NOTE: The base model must be ordered with a processor kit. 2 Processors and Heat Sink Available sockets: 2 Category Product Name / Description Part Number Processor Xeon E5-2609 v2 Processor Kit Intel® Xeon ® Processor E5-2609 v2 (2.50 GHz, 4C/4T, 10 MB) Xeon E5-2620 v2 Processor Kit Intel® Xeon ® Processor E5-2620 v2 (2.10 GHz, 6C/12T, 15 MB) Xeon E5-2630 v2 Processor Kit Intel® Xeon ® Processor E5-2630 v2 (2.60 GHz, 6C/12T, 15 MB) Xeon E5-2630L v2 Processor Kit Intel® Xeon ® Processor E5-2630L v2 (2.40 GHz, 6C/12T, 15 MB) Xeon E5-2637 v2 Processor Kit Intel® Xeon ® Processor E5-2637 v2 (3.50 GHz, 4C/8T, 15 MB) Xeon E5-2640 v2 Processor Kit Intel® Xeon ® Processor E5-2640 v2 (2 GHz, 8C/16T, 20 MB) Xeon E5-2650 v2 Processor Kit Intel® Xeon ® Processor E5-2650 v2 (2.60 GHz, 8C/16T, 20 MB) Xeon E5-2660 v2 Processor Kit Intel® Xeon ® Processor E5-2660 v2 (2.20 GHz, 10C/20T, 25 MB) Xeon E5-2670 v2 Processor Kit Intel® Xeon ® Processor E5-2670 v2 (2.50 GHz, 10C/20T, 25 MB) Xeon E5-2690 v2 Processor Kit Intel® Xeon ® Processor E5-2690 v2 (3 GHz, 10C/20T, 25 MB) Xeon E5-2695 v2 Processor Kit Intel® Xeon ® Processor E5-2695 v2 (2.40 GHz, 12C/24T, 30 MB) Xeon E5-2697 v2 Processor Kit Intel® Xeon ® Processor E5-2697 v2 (2.70 GHz, 12C/24T, 30 MB) Processor Heat Sink for the first processor Processor Heat Sink for the second processor, cooling fan kit included N8101-675F Heat Sink 1st 2nd N8101-676F N8101-677F N8101-678F N8101-679F N8101-680F N8101-681F N8101-682F N8101-683F N8101-684F N8101-686F N8101-685F (Standard) N8101-554F NOTE: Minimum one processor kit from above must be installed. The processors must be identical to configure dual processor system. Do not disable Hyper-Threading technology when using processors with a small number of cores and the system requires a lot of IO resources, in order to avoid performance down. NEC Corporation Revision 6.0 – January 28, 2015 11 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M The maximum number of logical processors supported by OS See the table below for the maximum number of logical processors that you can actually use on your system. Number of Logical Processors Supported by Operating Systems Microsoft Windows Server 2008 Standard Microsoft Windows Server 2008 Enterprise Microsoft Windows Server 2008 Standard (x64) Microsoft Windows Server 2008 Enterprise (x64) Microsoft Windows Server 2008 R2 Standard (x64) Microsoft Windows Server 2008 R2 Enterprise (x64) Microsoft Windows Server 2012 Standard Microsoft Windows Server 2012 Datacenter Microsoft Windows Server 2012 R2 Standard Microsoft Windows Server 2012 R2 Datacenter Red Hat Enterprise Linux 5 Red Hat Enterprise Linux 6 Red Hat Enterprise Linux 5 (EM64T) Red Hat Enterprise Linux 6 (x86_64) Red Hat Enterprise Linux 7 VMware ESXi 5.0 / 5.1 VMware ESXi 5.5 1 Maximum Available Number of Logical Processors 32 1 32 64 1 48 256 1 48 640 1 48 32 32 160 48 160 320 48 48 The maximum numbers of logical processors when using Hyper-V are below - Windows Server 2008 : 24 - Windows Server 2008 R2 : 64 - Windows Server 2012, Windows Server 2012 R2 : 320 NEC Corporation Revision 6.0 – January 28, 2015 12 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M 3 Memory 3.1 Memory Configuration Refer to the section in accordance with your operating system and memory configuration: Other than Windows server 2008 Standard Independent Channel Configuration: Refer to 3.2.1 Memory Sparing Configuration: Refer to 3.2.2 Memory Mirroring / Memory Lockstep Configuration: Refer to 3.2.3 Microsoft Windows 2008 Standard Independent Channel Configuration: Refer to 3.3.1 Memory Sparing Configuration: Refer to 3.3.2 3.2 Other than Windows server 2008 Standard 3.2.1 Independent Channel Configuration Available slots: 12 per processor Category Product Name / Description Part Number Unbuffered DIMM (UDIMM) 8GB DDR3-1600 UNB Memory Kit 2 x 4GB Unbuffered ECC DIMM, DDR3L-1600(PC3L-12800) NOTE: - Up to four sets (eight slots) per processor can be installed - This DIMM does not support x4 SDDC. N8102-534F Registered DIMM (RDIMM) 8GB DDR3-1600 REG Memory Kit 2 x 4GB Registered ECC DIMM, DDR3L-1600(PC3L-12800) 16GB DDR3-1600 REG Memory Kit 2 x 8GB Registered ECC DIMM, DDR3L-1600(PC3L-12800) 32GB DDR3-1600 REG Memory Kit 2 x 16GB Registered ECC DIMM, DDR3L-1600(PC3L-12800) 16GB DDR3-1866 REG Memory Kit 2 x 8GB Registered ECC DIMM, DDR3-1866(PC3-14900) NOTE: - Up to two sets (four slots) per processor can be installed - Memory voltage is set to 1.5V automatically - Not supported with the following processors: E5-2609 v2, E5-2620 v2, E5-2630 v2, E5-2630L v2, and E5-2640 v2 N8102-537F 32GB DDR3-1866 REG Memory Kit 2 x 16GB Registered ECC DIMM, DDR3-1866(PC3-14900) NOTE: - Up to two sets (four slots) per processor can be installed - Memory voltage is set to 1.5V automatically - Not supported with the following processors: E5-2609 v2, E5-2620 v2, E5-2630 v2, E5-2630L v2, and E5-2640 v2 N8102-546F 64GB DDR3-1600 LR Memory Kit 2 x 32GB Load Reduced ECC DIMM, DDR3L-1600(PC3L-12800) 128GB DDR3-1333 LR Memory Kit 2 x 64GB Load Reduced ECC DIMM, DDR3L-1333(PC3L-10600) N8102-540F 1600 MHz 1866 MHz Load Reduced DIMM (LRDIMM) N8102-538F N8102-539F N8102-545F N8102-541F NOTE: Minimum one memory kit per processor must be installed. It is recommended to install memory kits in multiples of two (four identical DIMMs) for quad-channel symmetric memory configurations to increase memory transfer speed. NEC Corporation Revision 6.0 – January 28, 2015 13 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M When two processors are installed, balance the DIMMs across the two processors. Mix configurations of UDIMM/RDIMM(1600MHz)/RDIMM(1866MHz)/LRDIMM are not supported. 3.2.2 Memory Sparing Configuration Available slots: 12 per processor Product Name / Description Part Number 12GB DDR3-1600 REG Memory Kit 3 x 4GB Registered ECC DIMM, DDR3L-1600(PC3L-12800) 24GB DDR3-1600 REG Memory Kit 3 x 8GB Registered ECC DIMM, DDR3L-1600(PC3L-12800) 48GB DDR3-1600 REG Memory Kit 3 x 16GB Registered ECC DIMM, DDR3L-1600(PC3L-12800) N8102-552 N8102-553 N8102-554 NOTE: Minimum one memory kit per processor must be installed. The configured memories must be identical. When two processors are installed, balance the DIMMs across the two processors. The logical memory capacity at the time of memory sparing becomes two-thirds of physical capacity with configurations less than 8GB DIMM and five-sixth physical capacity with configurations more than 16GB DIMM. 3.2.3 Memory Mirroring / Memory Lockstep Configuration Available slots: 12 per processor Product Name / Description Part Number 8GB DDR3-1600 REG Memory Kit 2 x 4GB Registered ECC DIMM, DDR3L-1600(PC3L-12800) 16GB DDR3-1600 REG Memory Kit 2 x 8GB Registered ECC DIMM, DDR3L-1600(PC3L-12800) 32GB DDR3-1600 REG Memory Kit 2 x 16GB Registered ECC DIMM, DDR3L-1600(PC3L-12800) N8102-548 N8102-549 N8102-550 NOTE: Minimum one memory kit per processor must be installed. At least 5 GB of memory is required for VMware ESXi™ 5.5. 3.3 Windows Server 2008 Standard 3.3.1 Independent Channel Configuration Available slots: 1 Product Name / Description Part Number 4GB DDR3-1600 REG Memory Kit 1 x 4GB Registered ECC DIMM, DDR3L-1600(PC3L-12800) N8102-582 NOTE: Only one Memory Kit can be installed regardless of the number of processors. NEC Corporation Revision 6.0 – January 28, 2015 14 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M 3.3.2 Memory Mirroring Configuration Available slots: 2 Product Name / Description Part Number 8GB DDR3-1600 REG Memory Kit 2 x 4GB Registered ECC DIMM, DDR3L-1600(PC3L-12800) N8102-548 NOTE: Only one Memory Kit (two DIMMs) can be installed regardless of the number of processors. Memory Configuration Feature Comparison See the table below for feature comparisons of memory configurations supported. Independent Channel Memory Sparing Memory Lockstep Memory Mirroring Performance Data Protection Best No Better Multiple single bit error protection Better No Redundancy Data Correction Available Memory No ECC, x4 SDDC Full physical memory No ECC, x8 SDDC Full physical memory Available Memory Channels Notes 4 Partly ECC, x4 SDDC 2/3 physical memory (4, 8GB DIMM) 5/6 physical memory (16GB DIMM) 4 Good Multiple single bit and multi bit error protection Fully ECC, x4 SDDC Half physical memory 4 4 All DIMMs in the system must be identical. Paired DIMMs must be identical. Paired DIMMs must be identical. NEC Corporation - Revision 6.0 – January 28, 2015 15 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M Maximum Memory Speed See the table below for the actual maximum memory transfer speed in Independent Channel / Memory Sparing Configuration. DDR3 memory speed depends on the type of DIMMs, the native memory bus speed of the memory controller and memory configuration. All memory buses operate at the clock frequency of the DIMM with the lowest frequency. Processor Type E5-2609 v2 UDIMM: 4GB 1600 RDIMM: 4, 8, 16 GB LRDIMM: 32GB LRDIMM: 64GB For Memory Sparing E5-2620 v2 E5-2630 v2 E5-2630L v2 # of DIMMs per processor Populated DIMMs UDIMM: 4GB 1600 RDIMM: 4, 8, 16 GB - 1333 MHz Up to 8 DIMMs - 1333 MHz 10 or more DIMMs Low (1.35V) Normal (1.5V) Low (1.35V) Normal (1.5V) Low (1.35V) Normal (1.5V) 800 MHz 1066 MHz 1333 MHz 1066 MHz 1066 MHz 800 MHz 1066 MHz 1333 MHz 1600 MHz Low (1.35V) 1600 MHz Normal (1.5V) Low (1.35V) Normal (1.5V) Low (1.35V) Normal (1.5V) Low (1.35V) Normal (1.5V) 1600 MHz 800 MHz 1066 MHz 1600 MHz 1066 MHz 1066 MHz 800 MHz 1066 MHz 1333 MHz 1600 MHz Up to 8 DIMMs Low (1.35V) 1600 MHz 10 or more DIMMs Normal (1.5V) Low (1.35V) Normal (1.5V) 1600 MHz 800 MHz 1066 MHz - Normal (1.5V) 1866MHz Up to 8 DIMMs 10 or more DIMMs - Low (1.35V) Normal (1.5V) 1600 MHz 1066 MHz 1066 MHz 800 MHz 1066 MHz Up to 8 DIMMs 10 or more DIMMs - Up to 8 DIMMs 10 or more DIMMs LRDIMM: 64GB For Memory Sparing E5-2637 v2 E5-2650 v2 E5-2660 v2 UDIMM: 4GB 1600 RDIMM: 4, 8, 16 GB E5-2670 v2 E5-2690 v2 E5-2695 v2 E5-2697 v2 1866 RDIMM: 8, 16 GB LRDIMM: 32GB LRDIMM: 64GB For Memory Sparing DIMM Speed - E5-2640 v2 LRDIMM: 32GB Memory Power Setting Up to 8 DIMMs 10 or more DIMMs - NOTE: Memory voltage is set to 1.5V automatically when installing DDR-1866 RDIMMs. NEC Corporation Revision 6.0 – January 28, 2015 16 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M Maximum Available Memory See the table below for the maximum memory size that you can actually use on your system. The maximum available memory is less than the maximum physical memory supported by your system because some chipsets require PCI resource space of about 750MB. PCI resource requirements vary depending on the type and the number of PCI cards you are using. Maximum Memory Size Supported by Operating Systems Microsoft Windows Server 2008 Standard 1 4 GB 1 Microsoft Windows Server 2008 Standard (x64) 1 Microsoft Windows Server 2008 R2 Standard 1 Microsoft Windows Server 2008 Enterprise 1 Microsoft Windows Server 2008 Enterprise (x64) 1 Microsoft Windows Server 2008 R2 Enterprise 1 Microsoft Windows Server 2012 Standard 1 Microsoft Windows Server 2012 Datacenter 1 Microsoft Windows Server 2012 R2 Standard 1 Microsoft Windows Server 2012 R2 Datacenter Red Hat Enterprise Linux 5 Red Hat Enterprise Linux 6 Red Hat Enterprise Linux 5 (EM64T) Red Hat Enterprise Linux 6 (x86_64) Red Hat Enterprise Linux 7 2 VMware ESXi 5.0 / 5.1 2 VMware ESXi 5.5 1 2 Maximum Available Memory 32 GB 4 GB (HW-DEP enabled) App. 2 GB(HW-DEP disabled) 32 GB 64 GB 2 TB 4 TB 16 GB 64 GB 1.5 TB 1.5 TB 16 GB 3 TB 1.5 TB 1 TB 3 TB 1 TB 1.5 TB 2 TB 4 TB 1.5 TB 1.5 TB The maximum available memory size of Hyper-V systems are below: - Windows Server 2008 Standard (x64) and Windows Server 2008 R2 Standard : 32 GB - Windows Server 2008 Enterprise (x64) and Windows Server 2008 R2 Enterprise : 1TB - Windows Server 2012, Windows Server 2012 R2:4 TB Up to 1TB of main memory is available to each virtual machine. NEC Corporation Revision 6.0 – January 28, 2015 17 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M 4 Internal Hard Disk Drives 4.1 RAID Configuration Refer to the section in accordance with your disk from factor and RAID configuration. Up to six 2.5-inch Drives Non-RAID Refer to 4.2.1 Available Interface SATA RAID 0/1/10 Refer to 4.2.2 SATA, SAS 512MB Cache Refer to 4.2.3 SATA, SAS 1GB Cache / Battery Refer to 4.2.4 SATA, SAS 1GB Cache / CacheVault Refer to 4.2.5 SATA, SAS Refer to 4.2.6 Available Interface SATA, SAS RAID 5/6/50/60 Up to eight 2.5-inch Drives RAID 0/1/10 RAID 5/6/50/60 512MB Cache Refer to 4.2.7 SATA, SAS 1GB Cache / Battery Refer to 4.2.8 SATA, SAS 1GB Cache / CacheVault Refer to 4.2.9 SATA, SAS NOTE: Up to four hard drives can be installed in the Embedded SATA configuration. Hot plug insertion/removal are not supported in the Embedded SATA configuration. All drives within a RAID array should be of the same type, capacity and rotation speed. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs and SAS SSDs can be mixed in one system. NEC Corporation Revision 6.0 – January 28, 2015 18 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M 4.2 4.2.1 Internal Drive Configuration Up to four Drives with embedded SATA non-RAID Controller Category Product Name / Description Part Number Storage Controller Embedded SATA Controller 2 x 6Gb/s SATA, 2 x 3Gb/s SATA Internal SATA Cable 4 x Single SATA to 1 x mini-SAS 2.5-inch Drive Cage 6 x 2.5-inch Hot-plug hard drive bays 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm (Standard) Cable Drive Cage Drive 4 slots available SATA HDD (Standard) (Standard) N8150-356 N8150-357 N8150-358 NOTE: Hot plug insertion/removal are not supported in the configuration. The maximum transfer speed for Slot 2 and Slot 3 is 3 Gb/s. NEC Corporation Revision 6.0 – January 28, 2015 19 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M 4.2.2 Up to six Drives with RAID 0/1 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1) LSI MegaRAID SAS 9272-8i RAID 0/1/10, 512 MB, Int. 8, PCIe 3.0 x8, 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i/9272-8i Internal SAS/SATA Cable two set of 1 x mini-SAS to 4 x Single SATA 2.5-inch Drive Cage 6 x 2.5-inch hot plug hard drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm N8103-172 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1 x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 450GB 15K Hot Plug 2.5-inch SAS HDD 1x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 600GB 15K Hot Plug 2.5-inch SAS HDD 1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1 x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1 x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s N8150-322B RAID BBU Recommended Cable Drive Cage Drive 6 slots available SAS HDD SATA HDD SAS SSD N8103-153 (Standard) (Standard) N8150-301B N8150-304B N8150-332B N8150-408B N8150-303B N8150-331B N8150-442 N8150-443 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All drives within a RAID array should be of the same type, capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs and SAS SSDs can be mixed in one system. NEC Corporation Revision 6.0 – January 28, 2015 20 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M 4.2.3 Up to six Drives with RAID 5/6 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1/5/6) LSI MegaRAID SAS 9272-8i RAID0/1/5/6/10/50/60, 512 MB, Int. 8, PCIe 3.0 x8, 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i/9272-8i Internal SAS/SATA Cable two set of 1 x mini-SAS to 4 x Single SATA 2.5-inch Drive Cage 6 x 2.5-inch hot plug hard drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm N8103-173 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1 x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 450GB 15K Hot Plug 2.5-inch SAS HDD 1x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 600GB 15K Hot Plug 2.5-inch SAS HDD 1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1 x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1 x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s N8150-322B RAID BBU Recommended Cable Drive Cage Drive 6 slots available SAS HDD SATA HDD SAS SSD N8103-153 (Standard) (Standard) N8150-301B N8150-304B N8150-332B N8150-408B N8150-303B N8150-331B N8150-442 N8150-443 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All hard drives within a RAID array should be of the same capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs and SAS SSDs can be mixed in one system. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. NEC Corporation Revision 6.0 – January 28, 2015 21 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M 4.2.4 Up to six Drives with RAID 5/6 Controller with 1 GB Cache/Battery Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9272-8i RAID 0/1/5/6/10/50/60, 1 GB, Int. 8, PCIe 3.0 x8, 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i/9272-8i MegaRAID CacheCade for LSI MegaRAID SAS NOTE: - SSD used for cache is required - The SSD capacity which can be used as read cache is up to 512 GB. N8103-174 Internal SAS/SATA Cable two set of 1 x mini-SAS to 4 x Single SATA 2.5-inch Drive Cage 6 x 2.5-inch hot plug drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1 x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 450GB 15K Hot Plug 2.5-inch SAS HDD 1x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 600GB 15K Hot Plug 2.5-inch SAS HDD 1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1 x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1 x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s (Standard) RAID BBU Recommended SSD Caching Recommended Cable Drive Cage Drive 6 slots available SAS HDD SATA HDD SAS SSD N8103-153 N8103-156 (Standard) N8150-301B N8150-322B N8150-304B N8150-332B N8150-408B N8150-303B N8150-331B N8150-442 N8150-443 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All hard drives within a RAID array should be of the same capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs and SAS SSDs can be mixed in one system. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. NEC Corporation Revision 6.0 – January 28, 2015 22 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M 4.2.5 Up to six Drives with RAID 5/6 Controller with 1 GB Cache/CacheVault Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9270CV-8i (with CV) RAID0/1/5/6/10/50/60, 1GB Cache, Int. 8ports, PCIe 3.0(x8), 6Gb/s, flash cache protection modules included MegaRAID CacheCade for LSI MegaRAID SAS NOTE: - SSD used for cache is required - The SSD capacity which can be used as read cache is up to 512 GB. N8103-168 Internal SAS/SATA Cable two set of 1 x mini-SAS to 4 x Single SATA 2.5-inch Drive Cage 6 x 2.5-inch hot plug hard drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1 x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 450GB 15K Hot Plug 2.5-inch SAS HDD 1x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 600GB 15K Hot Plug 2.5-inch SAS HDD 1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1 x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1 x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s (Standard) SSD Caching Recommended Cable Drive Cage Drive 6 slots available SAS HDD SATA HDD SAS SSD N8103-156 (Standard) N8150-301B N8150-322B N8150-304B N8150-332B N8150-408B N8150-303B N8150-331B N8150-442 N8150-443 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All hard drives within a RAID array should be of the same capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs and SAS SSDs can be mixed in one system. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. NEC Corporation Revision 6.0 – January 28, 2015 23 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M 4.2.6 Up to eight Drives with RAID 0/1 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1) LSI MegaRAID SAS 9272-8i RAID 0/1/10, 512MB, Int. 8, PCIe 3.0 x8, 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i/9272-8i Internal SAS/SATA Cable two set of 1 x mini-SAS to 4 x Single SATA 2.5-inch Drive Cage 6 x 2.5-inch hot plug hard drive bays 2.5-inch Hot Plug Drive Cage Kit 2 x 2.5-inch hot plug hard drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1 x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 450GB 15K Hot Plug 2.5-inch SAS HDD 1x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 600GB 15K Hot Plug 2.5-inch SAS HDD 1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1 x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1 x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s N8103-172 RAID BBU Recommended Cable Drive Cage Optional Drive Cage Required Drive SAS 8 slots HDD available SATA HDD SAS SSD N8103-153 (Standard) (Standard) N8154-41 N8150-301B N8150-322B N8150-304B N8150-332B N8150-408B N8150-303B N8150-331B N8150-442 N8150-443 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All hard drives within a RAID array should be of the same capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs and SAS SSDs can be mixed in one system. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. NEC Corporation Revision 6.0 – January 28, 2015 24 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M 4.2.7 Up to eight Drives with RAID 5/6 Controller with 512 MB Cache Category Product Name / Description Part Number Storage Controller Required RAID Controller (512MB, RAID 0/1/5/6) LSI MegaRAID SAS 9272-8i RAID0/1/5/6/10/50/60, 512MB, Int. 8, PCIe 3.0 x8, 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS9267-8i/9272-8i Internal SAS/SATA Cable two set of 1 x mini-SAS to 4 x Single SATA 2.5-inch Drive Cage 6 x 2.5-inch hot plug hard drive bays 2.5-inch Hot Plug Drive Cage Kit 2 x 2.5-inch hot plug hard drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1 x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 450GB 15K Hot Plug 2.5-inch SAS HDD 1x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 600GB 15K Hot Plug 2.5-inch SAS HDD 1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1 x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1 x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s N8103-173 RAID BBU Recommended Cable Drive Cage Optional Drive Cage Required Drive SAS 8 slots HDD available SATA HDD SAS SSD N8103-153 (Standard) (Standard) N8154-41 N8150-301B N8150-322B N8150-304B N8150-332B N8150-408B N8150-303B N8150-331B N8150-442 N8150-443 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All hard drives within a RAID array should be of the same capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs and SAS SSDs can be mixed in one system. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. NEC Corporation Revision 6.0 – January 28, 2015 25 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M 4.2.8 Up to eight Drives with RAID 5/6 Controller with 1 GB Cache/Battery Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9272-8i RAID 0/1/5/6/10/50/60, 1 GB, Int. 8, PCIe 3.0 x8, 6Gb/s RAID Battery Backup Unit for LSI MegaRAID SAS 9267-8i/9272-8i MegaRAID CacheCade for LSI MegaRAID SAS NOTE: - SSD used for cache is required - The SSD capacity which can be used as read cache is up to 512 GB. N8103-174 Internal SAS/SATA Cable two set of 1 x mini-SAS to 4 x Single SATA 2.5-inch Drive Cage 6 x 2.5-inch hot plug hard drive bays 2.5-inch Hot Plug Drive Cage Kit 2 x 2.5-inch hot plug hard drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1 x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 450GB 15K Hot Plug 2.5-inch SAS HDD 1x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 600GB 15K Hot Plug 2.5-inch SAS HDD 1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1 x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1 x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s (Standard) RAID BBU Recommended SSD Caching Recommended Cable Drive Cage Optional Drive Cage Required Drive SAS 8 slots HDD available SATA HDD SAS SSD N8103-153 N8103-156 (Standard) N8154-41 N8150-301B N8150-322B N8150-304B N8150-332B N8150-408B N8150-303B N8150-331B N8150-442 N8150-443 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All hard drives within a RAID array should be of the same capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs and SAS SSDs can be mixed in one system. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. NEC Corporation Revision 6.0 – January 28, 2015 26 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M 4.2.9 Up to eight Drives with RAID 5/6 Controller with 1 GB Cache/CacheVault Category Product Name / Description Part Number Storage Controller Required RAID Controller (1GB, RAID 0/1/5/6) LSI MegaRAID SAS 9270CV-8i (with CV) RAID0/1/5/6/10/50/60, 1GB Cache, Int. 8ports, PCIe 3.0(x8), 6Gb/s, flash cache protection modules included MegaRAID CacheCade for LSI MegaRAID SAS NOTE: - SSD used for cache is required - The SSD capacity which can be used as read cache is up to 512 GB. N8103-168 Internal SAS/SATA Cable two set of 1 x mini-SAS to 4 x Single SATA 2.5-inch Drive Cage 6 x 2.5-inch hot plug hard drive bays 2.5-inch Hot Plug Drive Cage Kit 2 x 2.5-inch hot plug hard drive bays 300GB 10K Hot Plug 2.5-inch SAS HDD 1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 450GB 10K Hot Plug 2.5-inch SAS HDD 1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 600GB 10K Hot Plug 2.5-inch SAS HDD 1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 900GB 10K Hot Plug 2.5-inch SAS HDD 1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 1.2TB 10K Hot Plug 2.5-inch SAS HDD 1 x 1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 146.5GB 15K Hot Plug 2.5-inch SAS HDD 1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 300GB 15K Hot Plug 2.5-inch SAS HDD 1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 450GB 15K Hot Plug 2.5-inch SAS HDD 1x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 600GB 15K Hot Plug 2.5-inch SAS HDD 1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 250GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 500GB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 1TB 7.2K Hot Plug 2.5-inch SATA HDD 1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm 200GB Hot Plug 2.5-inch SAS SSD 1 x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s 400GB Hot Plug 2.5-inch SAS SSD 1 x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s (Standard) SSD Caching Recommended Cable Drive Cage Optional Drive Cage Required Drive SAS 8 slots HDD available SATA HDD SAS SSD N8103-156 (Standard) N8154-41 N8150-301B N8150-322B N8150-304B N8150-332B N8150-408B N8150-303B N8150-331B N8150-442 N8150-443 N8150-356 N8150-357 N8150-358 N8150-711 N8150-712 NOTE: All hard drives within a RAID array should be of the same capacity and rotation speed. Up to two kinds of drives selected from SAS 10K HDDs, SAS 15K HDDs, SATA HDDs and SAS SSDs can be mixed in one system. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. NEC Corporation Revision 6.0 – January 28, 2015 27 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M 5 Optical Drive Category Product Name / Description Part Number Internal 1 slot available Internal Slim DVD-ROM drive Slim DVD-ROM drive DVD read speed: 8x (DVD-ROM / DVD-R / DVD-RW) CD read speed: 24x (CD-ROM / CD-R/RW) Internal DVD Super Multi Drive Slim DVD Super Multi drive, not including writing software DVD Read speed: 8x (DVD-R / DVD-RW / DVD-R DL / DVD+R / DVD+RW / DVD+R DL / DVD-ROM) DVD-RAM read speed: 5x CD read speed: 24x (CD-ROM / CD-R/RW) External DVD-ROM drive DVD-ROM drive, Bus powered, 1.2 A required DVD Read speed: 4x (DVD-ROM / DVD-R / DVD-RW) CD read speed: 24x (CD-ROM / CD-R/RW) N8151-122 External N8151-107F N8160-91 NOTE: Up to 1 optical drive can be connected. N8154-41 2.5-inch Drive Cage cannot be installed when an internal optical drive is installed. NEC Corporation Revision 6.0 – January 28, 2015 28 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M 6 PCI Card Please refer to Supported PCI Cards and Installable Slots with regard to the position of PCI slot which can mount PCI card supported. 6.1 Network Interface Controller Category Riser 1GbE 10GbE Adapter 1GbE 10GbE NEC Corporation Product Name / Description Part Number Dual Port 1000BASE-T Riser Card Broadcom® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x8 Dual Port 10GBASE-T Riser Card Broadcom® BCM57810 Converged Controller PCIe 2.0 x8 NOTE: - Jumbo frame is not supported on Redhat Enterprise Linux 6 (x86) operating systems. Dual Port 10GBASE SFP+ Riser Card Broadcom® BCM57810 Converged Controller PCIe 3.0 x8 NOTE: - N8104-129 SFP+ Module is required to connect with an optical cable. - Up to two SFP+ Modules can be installed. - Supports up to three adapters of 10Gb Network Adapter on any supported operating systems, excluding 32 bit operating system. - Up to two 10Gb Network Adapter on Windows Server 2008(x86) and Red Hat Enterprise Linux 5(x86), up to one 10G Network Adapter on Red Hat Enterprise Linux 6(x86). - Jumbo frame is not supported on Redhat Enterprise Linux 6 (x86) operating systems. N8104-135 1000BASE-T Adapter Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1 Dual Port 1000BASE-T Adapter Broadcom ® BCM5718 Gigabit Ethernet Controller PCIe 2.0 x1 Dual Port 1000BASE-T Adapter Intel® 82580 Gigabit Ethernet Controller PCIe 2.0 x4 Quad Port 1000BASE-T Adapter Broadcom ® BCM5719 Gigabit Ethernet Controller PCIe 2.0 x4 NOTE: - Network cables with RJ-45 plug covers cannot be used. N8104-138 10GBASE Adapter (SFP+/2ch) Broadcom NetXtreme II BCM957711 10G SFP+ Dual Port Network Interface Card PCIe 2.0 x8 NOTE: - N8104-129 SFP+ Module is required to connect with an optical cable. - Up to 2 SFP+ Modules can be installed. - Supports up to three adapters of 10Gb Network Adapter on any supported operating systems, excluding 32 bit operating system. - Up to two 10Gb Network Adapter on Windows Server 2008(x86) and Red Hat Enterprise Linux 5(x86), up to one 10G Network Adapter on Red Hat Enterprise Linux 6(x86). N8104-128 Revision 6.0 – January 28, 2015 N8104-136 N8104-137 N8104-132 N8104-145 N8104-133 29 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M SFP+ Module Dual Port 10GBASE SFP+ Adapter Intel 82599ES, 10G SFP+ Dual Port Network Interface Card PCIe 2.0 x8 NOTE: - N8104-129 SFP+ Module is required to connect with an optical cable. - Up to 2 SFP+ Modules can be installed. - Supports up to three adapters of 10Gb Network Adapter on any supported operating systems, excluding 32 bit operating system. - Up to two 10Gb Network Adapter on Windows Server 2008(x86) and Red Hat Enterprise Linux 5(x86), up to one 10G Network Adapter on Red Hat Enterprise Linux 6(x86). N8104-148 10GBASE Adapter (SFP+/2ch) Broadcom NetXtreme II BCM957711 10G SFP+ Dual Port Network Interface Card PCIe 2.0 x8 NOTE: - Up to one adapter only can be installed in a configuration with E5-2609 v2. - N8104-129 SFP+ Module is required to connect with an optical cable. - Up to 2 SFP+ Modules can be installed. - Supports up to three adapters of 10Gb Network Adapter on any supported operating systems, excluding 32 bit operating system. - Up to two 10Gb Network Adapter on Windows Server 2008(x86) and Red Hat Enterprise Linux 5(x86), up to one 10G Network Adapter on Red Hat Enterprise Linux 6(x86). - The latest driver is required for Window Server 2008 and Windows Server 2008 R2. Dual Port 10GBASE-T Adapter Intel X540-BT2 PCIe 2.0(x8) SFP+ Module (10G-SR) 1 x SFP+ Module for N8104-128/-137/-148/-149 N8104-149 N8104-153 N8104-129 NOTE: Supports up to two 10Gb Network Adapter on Windows Server 2008(x86) and Red Hat Enterprise Linux 5(x86), and up to one on Red Hat Enterprise Linux 6(x86). For other operating systems, up to three 10Gb adapters can be installed. Network performance may be reduced depending on the applications and memory performance when three or more 10Gb Network Adapters are installed. NIC Teaming feature – NIC Teaming and bonding features See the table below for supported network interfaces and OS combinations. Windows Server 2008 support BASP (Broadcom Advanced Server Program) or Intel PROSet teaming while Windows Server 2012 and Linux support teaming with bonding function supported by OS. Network Interface Team 1GbE NIC Embedded 1GbE NIC and N8104-135/-138/-132/-133 Up to four teams per one system Up to four ports per one team 1GbE NIC Up to four teams per one system NEC Corporation Revision 6.0 – January 28, 2015 Operating Systems Windows Server 2008 Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 5.9 or later Red Hat Enterprise Linux 6.4 or later Red Hat Enterprise Linux 7.0 or later Windows Server 2008 30 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M N8104-145 10GbE NIC N8104-128/137 Up to four ports per one team Windows Server 2008 R2 Up to three teams per one system Up to four ports per one team Windows Server 2008 Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 5.9 or later Red Hat Enterprise Linux 6.4 or later Red Hat Enterprise Linux 7.0 or later 10GbE NIC N8104-149 10GbE NIC N8104-136 Up to one teams per one system Up to two ports per one team Windows Server 2008(x86) Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 6.5 or later Windows Server 2008 Windows Server 2008 R2 Windows Server 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 5.9 or later Red Hat Enterprise Linux 6.4 or later Red Hat Enterprise Linux 7.0 or later NOTE: NIC Teaming feature is not supported on iSCSI interfaces. The network interfaces for teaming must be the same. When 10GbE and 1GbE NIC teamings are mixed, the teams must be up to four per one system. Using iSCSI See the table below for supported network interfaces and operating system combinations. Category Network Interface Operating Systems 1GbE Embedded 1GbE NIC Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2, Red Hat Enterprise Linux 5, Red Hat Enterprise Linux 6, VMware Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2, RHEL5, RHEL6, VMware Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2, Red Hat Enterprise Linux 5, Red Hat Enterprise Linux 6, VMware Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2, Red Hat Enterprise Linux 5, Red Hat Enterprise Linux 6, VMware Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2, Red Hat Enterprise Linux 5, Red Hat Enterprise Linux 6, VMware Windows Server 2008, Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2, Red Hat Enterprise Linux 5, Red Hat Enterprise Linux 6, VMware Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2, Red Hat Enterprise Linux 5, Red Hat Enterprise Linux 6, VMware Windows Server 2008 R2 / Windows Server 2012 / Windows Server 2012 R2 / Red Hat Enterprise Linux 6.5 or later / VMware N8104-138 N8104-132 N8104-133 N8104-135 10GbE N8104-128 N8104-137 N8104-149 NOTE: NIC Teaming feature is not supported on iSCSI interfaces. 6.2 InfiniBand Category Product Name / Description Part Number Controller Single Port InfiniBand Adapter Mellanox ConnectX-3 VPI, MCX353A-FCBT, FDR, PCIe 3.0(x8) NOTE: - For using with Windows Server 2012 R2, download the driver N8104-146 NEC Corporation Revision 6.0 – January 28, 2015 31 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M kit from the NEC website. Dual Port InfiniBand Adapter Mellanox ConnectX-3 VPI, MCX354A-FCBT, FDR, PCIe 3.0(x8) NOTE: - For using with Windows Server 2012 R2, download the driver kit from the NEC website. Cable Switch Unit Power Supply InfiniBand Cable 2m/FRD Copper InfiniBand Cable 3m/FDR Copper InfiniBand Switch 36 ports/FDR Mellanox MSX6036F-1SFR 36 ports, FDR, One power supply module included, no power cord Redundant Power Supply Unit Power supply module for 36 ports InfiniBand switch, no power cord N8104-147 K410-304(02) K410-304(03) NE3707-061 NE3707-063 NOTE: Up to two InfiniBand adapters can be installed into the system and two adapters should be of the same type. The InfiniBand adapters and other options are make-to-order products. Please consult our sales representative in regards to production lead time. 6.3 PCIe SSD Adapter Category Product Name / Description Part Number PCIe SSD PCIe SSD Adapter 365GB Fusion-io ioDrive2 365GB PCIe 2.0(x4), Low Profile / Full Height N8118-01 NOTE: Server Core is not supported Warranty period is the shorter of 3 years (37 months) or until the total bytes of written value (PBW) exceeds 4 PB. Check the PBW periodically with the utility for the PCIe SSD adapter. At least 8GB of memory per one PCIe SSD Adapter is required for adequate performance with this product. Refer to the user's guide for details. Operating system can not be installed in this product. 6.4 External Storage Controller 6.4.1 RAID Controller Category Product Name / Description Part Number Controller RAID Controller (1GB, RAID0/1/5/6) LSI MegaRAID SAS 9285CV-8e RAID0/1/5/6/10/50/60, 1GB, Ext. 8, PCIe 3.0 x8, SAS 6Gb/s, SATA 6Gb/s, flash cache protection modules included N8103-161 NOTE: Only one external RAID controller can be installed when installing an internal RAID Controller with RAID Backup Unit. To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process. It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure. NEC Corporation Revision 6.0 – January 28, 2015 32 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M 6.4.2 Fibre Channel / SAS Controller Category Product Name / Description Part Number Fibre Channel Fibre Channel Controller (1ch) Emulex LightPulse LPe1250-F8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0 x8 Fibre Channel Controller (2ch) Emulex LightPulse LPe12002-M8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0 x8 Fibre Channel Controller (1ch) Emulex LightPulse LPe16000B-M6 Host Bus Adapter 16Gb/s, Optical, PCIe 3.0 x8 Fibre Channel Controller (2ch) Emulex LightPulse LPe16002B-M6 Host Bus Adapter 16Gb/s, Optical, PCIe 3.0 x8 NOTE: - Not supported in a single processor configuration with Xeon E5-2403 v2/-2407 v2 N8190-153 SAS Controller LSI SAS9212-4i4e Host Bus Adapter 6Gb/s SAS, Int. 4(7-pin SATA ) / ext. 4(SFF-8088), PCIe 2.0(x8), Low Profile / Full Height NOTE: - For using this product in Windows Server 2012 R2 environment, download the driver from the NEC website. SAS Controller LSI SAS9300-8e Host Bus Adapter 12Gb/s SAS, ext. 8(SFF-8644 x2), PCIe 3.0 x8 N8103-142 SAS 6.5 N8190-154 N8190-157 N8190-158A N8103-184 Serial Port Adapter Product Name / Description Part Number Serial Port Adapter N8117-01A Serial port fixed to PCI bracket NOTE: Up to one Serial Port Adapter can be installed. NEC Corporation Revision 6.0 – January 28, 2015 33 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M 7 Other Add-in Components 7.1 Power Supply Product Name / Description Part Number 450W Hot Plug Power Supply 1 x 450 Watt 80 PLUS® Platinum 800W Hot Plug Power Supply 1 x 800 Watt 80 PLUS® Platinum 800W Hot Plug Power Supply 1 x 800 Watt 80 PLUS® Titanium NOTE: - The power supply only supports 200-240VAC input. N8181-86F N8181-87F N8181-118F NOTE: The power units must be the same to configure redundancy. Use the NEC Power Supply Selector to select appropriate size for power units. For details, please visit the NEC website at: http://www.nec.com/en/global/prod/express/collateral/tools/PowerSelector_G01.xls 7.2 Trusted Platform Module Kit Product Name / Description Part Number Trusted Platform Module Kit TPM 1.2 module N8115-19 NOTE: The kit is not available in China. The kit is not removable after attachment. "TPM Support" in BIOS setup menu must be activated prior to use of this product. To use Windows BitLocker drive encryption, be sure to keep the "recovery password" of BitLocker function. The recovery password is required to restore data for hardware replacement during a system error. 7.3 Internal Flash Memory Available socket: 1 Product Name / Description Part Number Internal Flash Memory Internal flash memory to enable software and tools in the EXPRESSBUILDER DVD without DVD media NOTE: - Before use, software and tools must be copied from the EXPRESSBUILDER DVD to the flash memory. - The following operations can be performed with the flash memory: - Installation of Windows server with express setup - Installation of Starter Pack—the package of NEC qualified drivers and system setting tools - Installation of NEC ESMPRO Agent and Universal RAID Utility - Performance of the Test and Diagnosis Tool N8115-07 7.4 Flash FDD Choose the Flash FDD if you need to prepare an alternative device for a floppy drive. Product Name / Description Part Number Flash FDD USB flash emulating USB floppy disk, Native capacity 1.44 MB N8160-96 NEC Corporation Revision 6.0 – January 28, 2015 34 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M NOTE: Up to one drive can be connected. 7.5 Front Bezel Product Name / Description Part Number Front Bezel Front bezel for R120e-1M N8146-47F NEC Corporation Revision 6.0 – January 28, 2015 35 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M 8 Add-on Components 8.1 17-inch LCD Console Drawer Category Drawer Drawer w/ KVM Cable Drawer Drawer w/o KVM Keypad Product Name / Description Part Number 17-inch LCD Console Drawer (8port) 17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM switch, 1U height Switch Unit Connection Cable Set (USB, 1.8m) 1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 3m) 3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 5m) 5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A 17inch LCD Console Unit 1U 17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m, 15-pin mini D-sub VGA cable 2 m 17inch LCD Console Drawer (1port) 17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8 m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m Keyboard Unit (JP) JP 108-keys Keyboard with 10-key for N8143-84F 17inch LCD Console Drawer (1port) Keyboard Unit (UK) UK 104-keys Keyboard with 10-key, for N8143-84F 17inch LCD Console Drawer (1port) N8143-77F K410-118(1A) K410-118(03) K410-118(05) N8143-76F N8143-84F N8143-85 N8143-87 NOTE: There are two VGA connectors on R120e-1M, one on the front side and one on the rear side. However, the front side only works when both are connected at the same time. 8.2 KVM Switch Category Product Name / Description Part Number KVM Switch Server Switch Unit (8 server) 1U USB 8 port KVM switch N8191-12F Switch Unit Connection Cable Set (USB,1.8m) 1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable 1.8 m 1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2 K410-118(1A) Cable KVM Cascading K410-118(03) K410-118(05) K410-119(1A) NOTE: There are two VGA connectors on R120e-1M, one on the front side and one on the rear side. However, the front side only works when both are connected at the same time. NEC Corporation Revision 6.0 – January 28, 2015 36 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M 8.3 Cable Management Arm Product Name / Description Part Number Cable Management Arm 1U Kit for R120e-1M N8143-96 NOTE: The extension bracket of inner rail must be attached when installing the Cable Management Arm. 8.4 Server Management License The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to Server Management for the standard management features. For more extensive remote KVM and remote media features, choose the following kit. Product Name / Description Part Number Remote KVM and Media License Kit N8115-04 License for one server. Remote KVM and remote media are enabled regardless of OS status. Remote KVM: Displays a graphics console on the web browser of the remote terminal (PC/server). Controls keyboard and mouse via the remote terminals' web browser Remote media: Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals (PC/server) as if accessing the local drives. NOTE: Remote KVM and remote media features are not available for virtual machines. NEC Corporation Revision 6.0 – January 28, 2015 37 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M References Server Management The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features listed in the table below. Standard Hardware monitoring Temperature/voltage/power/standard LAN/fan/degeneration (memory/hard drive) Hardware event log collection Boot monitoring Remote KVM Booting, BIOS/POST stall, OS stall, shutdown HW error, Boot error and OS panic (by SNMP, E-Mail) POST/BIOS setup, DOS utility (via LAN) Panic screen, Boot screen With Remote KVM and Media License kit Text-based screen (OS console) 2 2 GUI-based screen (OS console) - Remote console recording - Remote control Remote reset/power on-off/ dump (via LAN) OS shutdown 1 Remote media (CD/DVD/FD) - Server Management Command Line Protocol (DMTF compliant) Remote control via Web browser (without dedicated app) Remote batch 1 1 2.0 Alerting 2 Others Set automatic IP address via DNS/DHCP Remote wakeup Wake On LAN, Wake On Ring Centralized management Industry standard Monitoring and control of multiple servers 1 IPMI 2.0 Scheduling (without UPS) 1 2 The feature is not supported on VMware ESXi systems. The standard serial port is not available for the feature. NEC Corporation Revision 6.0 – January 28, 2015 38 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M OS Support Matrix for PCI Cards and Embedded Controllers Product Name - Embedded SATA non-RAID Controller - Embedded 1GbE NIC N8103-172 RAID Controller (512 MB, RAID 0/1) N8103-173 RAID Controller (512 MB, RAID 0/1/5/6) N8103-174 RAID Controller (1 GB,RAID 0/1/5/6) N8103-168 RAID Controller (1 GB,RAID 0/1/5/6) N8103-161 RAID Controller (1 GB,RAID 0/1/5/6) N8103-142 SAS Controller SAS Controller N8103-184 N8190-153 Fibre Channel Controller N8190-154 Fibre Channel Controller (2ch) N8190-157 Fibre Channel Controller N8190-158 Fibre Channel Controller (2ch) N8104-135 Dual Port 1000BASE-T Riser Card N8104-138 1000BASE-T adapter N8104-132 Dual Port 1000BASE-T Adapter N8104-133 Quad Port 1000BASE-T Adapter N8104-145 Dual Port 1000BASE-T Adapter N8104-136 Dual Port 10GBASE-T Riser Card N8104-137 Dual Port 10GBASE SFP+ Riser Card N8104-128 N8104-149 N8104-153 N8104-148 N8104-146 10GBASE adapter (SFP+/2ch) 10GBASE adapter (SFP+/2ch) Dual Port 10GBASE-T Adapter Dual Port 10GBASE SFP+ Adapter Single Port InfiniBand Adapter N8104-147 N8118-01 NEC Corporation ESXi 5.0 ESXi 5.1 ESXi 5.5 RHEL 5 x64 RHEL 5 RHEL 6 x64 RHEL 6 RHEL 7 WS 2008 x64 WS 2008 WS 2008 R2 WS 2012 WS 2012 R2 Part number - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Dual Port InfiniBand Adapter - - - - - - - - PCIe SSD Adapter 365GB - - - - - - - Revision 6.0 – January 28, 2015 - - - - - 39 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M Supported PCI Cards and Installable Slots Slots Part Number Product Name #1A #1B #1C #1D - - - - - - RAID Controller (1 GB,RAID 0/1/5/6) - - - N8103-168 RAID Controller (1 GB,RAID 0/1/5/6) - RAID Controller (1 GB,RAID 0/1/5/6) - N8103-142 SAS Controller - N8103-184 SAS Controller - N8190-153 Fibre Channel Controller - N8190-154 Fibre Channel Controller (2ch) - N8190-157 Fibre Channel Controller - N8190-158 Fibre Channel Controller (2ch) - - N8103-161 N8104-135 Dual Port 1000BASE-T Riser Card - - - N8104-138 1000BASE-T adapter - Dual Port 1000BASE-T Adapter - N8104-145 Dual Port 1000BASE-T Adapter - N8104-133 Quad Port 1000BASE-T Adapter - - N8104-132 N8104-136 Dual Port 10GBASE-T Riser Card - - - N8104-137 Dual Port 10GBASE SFP+ Riser Card - - - N8104-128 10GBASE adapter (SFP+/2ch) - N8104-153 Dual Port 10GBASE-T Adapter - N8104-148 Dual Port 10GBASE SFP+ Adapter - N8104-149 10GBASE adapter (SFP+/2ch) - N8104-146 Single Port InfiniBand Adapter - N8104-147 Dual Port InfiniBand Adapter - N8118-01 PCIe SSD Adapter 365GB - N8117-01A Serial Port Adapter - - N8103-172 RAID Controller (512 MB, RAID 0/1) N8103-173 RAID Controller (512 MB, RAID 0/1/5/6) N8103-174 NEC Corporation Revision 6.0 – January 28, 2015 - - - 40 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less. NEC Corporation Revision 6.0 – January 28, 2015 41 SYSTEM CONFIGURATION GUIDE – NEC Express5800R120e-1M Revision History Revision Date Description 6.0 January 28, 2015 5.1 November 21, 2014 5.0 October 16, 2014 4.0 July 18, 2014 3.0 January 16, 2014 2.0 October 25, 2013 1.0 September 13, 2013 New products added: SAS Controller / N8103-184 Part number changed: Flash FDD / N8160-96 Others: Supported N8104-153 Dual Port 10GBASE-T Adapter on Windows Server 2012 and Windows Server 2012 R2 New products added: 10GBASE Adapter (SFP+/2ch) / N8104-149 PCIe SSD Adapter 365GB / N8118-01 Part number changed: Fibre Channel Controller (2ch) / N8190-158A Discontinued product deleted: Dual Port 10Gb Converged Network Adapter / N8104-131 Others: Added Red Hat Linux 7 to the list of operating system supported Updated OS support matrix New products added: 450GB 15K Hot Plug 2.5-inch SAS HDD / N8150-442 600GB 15K Hot Plug 2.5-inch SAS HDD / N8150-443 Dual Port 10GBASE SFP+ Adapter / N8104-148 Dual Port 10GBASE-T Adapter / N8104-153 Others: Updated the Specification table (Regulatory and Safety) SAS HDD part numbers changed (added “B”) Added configuration limitations for N8190-157/158 Added a note for processors Updated the Maximum Memory Speed matrix Updated notes for 10Gb Network Adapters WS2012 R2 is added in the supported OS for iSCSI Added a note for InfiniBand Adapter WS2012 R2 is supported with N8103-142 SAS Controller Added a note for VGA connectors New products added: 800W Hot Plug Power Supply / N8181-118F Part number changed: Internal Slim DVD-ROM Drive / N8151-122 Others: Added Windows Server 2012 R2 and Red Hat Linux 5.9 to the list of operating system supported Updated OS support matrix New products added: Single Port InfiniBand Adapter / N8104-146 Dual Port InfiniBand Adapter / N8104-147 InfiniBand Cable 2m/FRD / K410-304(02) InfiniBand Cable 3m/FRD / K410-304(03) InfiniBand Switch 36 ports/FDR / NE3707-061 Redundant Power Supply Unit / NE3707-063 Others: Added VMware ESXi 5.5 to the list of operating system supported Updated OS support matrix Initial release NEC Corporation Revision 6.0 – January 28, 2015 42