NCP1246 Fixed Frequency Current Mode Controller for Flyback Converters The NCP1246 is a new fixed−frequency current−mode controller featuring the Dynamic Self−Supply. This function greatly simplifies the design of the auxiliary supply and the VCC capacitor by activating the internal startup current source to supply the controller during start−up, transients, latch, stand−by etc. This device contains a special HV detector which detect the application unplug from the AC input line and triggers the X2 discharge current. This HV structure allows the brown−out detection as well. It features a timer−based fault detection that ensures the detection of overload and an adjustable compensation to help keep the maximum power independent of the input voltage. Due to frequency foldback, the controller exhibits excellent efficiency in light load condition while still achieving very low standby power consumption. Internal frequency jittering, ramp compensation, and a versatile latch input make this controller an excellent candidate for the robust power supply designs. A dedicated Off mode allows to reach the extremely low no load input power consumption via “sleeping” whole device and thus minimize the power consumption of the control circuitry. Features • Fixed−Frequency Current−Mode Operation (65 kHz and 100 kHz frequency options) • Frequency Foldback then Skip Mode for Maximized Performance in • • • • • • • • • • • • www.onsemi.com MARKING DIAGRAM 8 SOIC−7 CASE 751U 46XXfff ALYWX G 1 46XXfff = Specific Device Code XX = A, B or AL fff = 065 or 100 A = Assembly Location L = Wafer Lot Y = Year W = Work Week G = Pb−Free Package PIN CONNECTIONS Latch 1 8 HV 6 VCC FB 2 CS 3 GND 4 5 DRV Light Load and Standby Conditions (Top View) Timer−Based Overload Protection with Latched (Option A) or Auto−Recovery (Option B) Operation High−voltage Current Source with Brown−Out Detection and ORDERING INFORMATION See detailed ordering and shipping information in the package Dynamic Self−Supply, Simplifying the Design of the VCC Circuitry dimensions section on page 38 of this data sheet. Frequency Modulation for Softened EMI Signature Adjustable Overpower Protection Dependant on the Bulk Voltage Latch−off Input Combined with the Overpower Protection Sensing Input VCC Operation up to 28 V, With Overvoltage Detection 500/800 mA Source/Sink Drive Peak Current Capability Typical Applications 10 ms Soft−Start, 4 ms Soft−Start (AL/BL Versions) • AC−DC Adapters for Notebooks, LCD, and Printers Internal Thermal Shutdown • Offline Battery Chargers No−Load Standby Power < 30 mW • Consumer Electronic Power Supplies X2 Capacitor in EMI Filter Discharging Feature • Auxiliary/Housekeeping Power Supplies These Devices are Pb−Free, Halogen Free/BFR Free • Offline Adapters for Notebooks and are RoHS Compliant © Semiconductor Components Industries, LLC, 2015 March, 2015 − Rev. 6 1 Publication Order Number: NCP1246/D NCP1246 TYPICAL APPLICATION EXAMPLE Figure 1. Flyback Converter Application Using the NCP1246 PIN FUNCTION DESCRIPTION Pin No Pin Name Function Pin Description 1 LATCH Latch−Off Input Pull the pin up or down to latch−off the controller. An internal current source allows the direct connection of an NTC for over temperature detection. 2 FB Feedback + Shutdown pin An optocoupler collector to ground controls the output regulation. The part goes to the low consumption Off mode if the FB input pin is pulled to GND. 3 CS Current Sense 4 GND − 5 DRV Drive output 6 VCC VCC input 8 HV High−voltage pin This Input senses the Primary Current for current−mode operation, and offers an overpower compensation adjustment. The controller ground Drives external MOSFET This supply pin accepts up to 28 Vdc, with overvoltage detection. The pin is connected to an external auxiliary voltage. It is not allowed to connect another circuit to this pin to keep low input power consumption. Connects to the rectified AC line to perform the functions of Start−up Current Source, Self−Supply, brown−out detection and X2 capacitor discharge function and the HV sensing for the overpower protection purposes. It is not allowed to connect this pin to DC voltage. www.onsemi.com 2 NCP1246 SIMPLIFIED INTERNAL BLOCK SCHEMATIC LATCH ON_CMP Figure 2. Simplified Internal Block Schematic www.onsemi.com 3 NCP1246 MAXIMUM RATINGS Rating Symbol Value Unit –0.3 to 20 ±1000 (peak) V mA VCCPower Supply voltage, VCC pin, continuous voltage Power Supply voltage, VCC pin, continuous voltage (Note 1) –0.3 to 28 ±30 (peak) V mA Maximum voltage on HV pin (Dc−Current self−limited if operated within the allowed range) –0.3 to 500 ±20 V mA Vmax Maximum voltage on low power pins (except pin 5, pin 6 and pin 8) (Dc−Current self−limited if operated within the allowed range) (Note 1) –0.3 to 10 ±10 (peak) V mA RqJ−A Thermal Resistance SOIC−7 Junction-to-Air, low conductivity PCB (Note 2) Junction-to-Air, medium conductivity PCB (Note 3) Junction-to-Air, high conductivity PCB (Note 4) 162 147 115 RqJ−C Thermal Resistance Junction−to−Case 73 °C/W TJMAX Operating Junction Temperature −40 to +150 °C Storage Temperature Range −60 to +150 °C > 2000 V ESD Capability, Machine Model per JEDEC Standard JESD22, Method A115A > 200 V ESD Capability, Charged Device Model per JEDEC Standard JESD22−C101D > 1000 V DRV (pin 5) Maximum voltage on DRV pin (Dc−Current self−limited if operated within the allowed range) (Note 1) VCC (pin 6) HV (pin 8) TSTRGMAX °C/W ESD Capability, HBM model (All pins except HV) per JEDEC Standard JESD22, Method A114E Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality should not be assumed, damage may occur and reliability may be affected. 1. This device contains latch-up protection and exceeds 100 mA per JEDEC Standard JESD78. 2. As mounted on a 80 x 100 x 1.5 mm FR4 substrate with a single layer of 50 mm2 of 2 oz copper traces and heat spreading area. As specified for a JEDEC 51-1 conductivity test PCB. Test conditions were under natural convection or zero air flow. 3. As mounted on a 80 x 100 x 1.5 mm FR4 substrate with a single layer of 100 mm2 of 2 oz copper traces and heat spreading area. As specified for a JEDEC 51-2 conductivity test PCB. Test conditions were under natural convection or zero air flow. 4. As mounted on a 80 x 100 x 1.5 mm FR4 substrate with a single layer of 650 mm2 of 2 oz copper traces and heat spreading area. As specified for a JEDEC 51-3 conductivity test PCB. Test conditions were under natural convection or zero air flow. www.onsemi.com 4 NCP1246 ELECTRICAL CHARACTERISTICS (For typical values TJ = 25°C, for min/max values TJ = −40°C to +125°C, VHV = 125 V, VCC = 11 V unless otherwise noted) Characteristics Test Condition Symbol Min Typ Max Unit VHV(min) − 30 40 V VCC = 0 V VCC = VCC(on) − 0.5 V Istart1 Istart2 0.2 5 0.5 8 0.8 11 mA Off−state leakage current VHV = 500 V, VCC = 15 V Istart(off) 10 25 50 mA Off−mode HV supply current VHV = 141 V, VHV = 325 V, VCC loaded by 4.7 mF cap IHV(off) − − 45 50 60 70 mA HV current source regulation threshold VCC(reg) 8 11 − V Turn−on threshold level, VCC going up HV current source stop threshold VCC(on) 11.0 12.0 13.0 V HV current source restart threshold VCC(min) 9.5 10.5 11.5 V Turn−off threshold VCC(off) 8.5 8.9 9.3 V HIGH VOLTAGE CURRENT SOURCE Minimum voltage for current source operation Current flowing out of VCC pin SUPPLY Overvoltage threshold VCC(ovp) 25 26.5 28 V Blanking duration on VCC(off) and VCC(ovp) detection tVCC(blank) − 10 − ms VCC decreasing level at which the internal logic resets VCC(reset) 4.8 7.0 7.7 V VCC level for ISTART1 to ISTART2 transition VCC(inhibit) 0.2 0.8 1.25 V DRV open, VFB = 3 V, 65 kHz DRV open, VFB = 3 V, 100 kHz ICC1 ICC1 1.3 1.3 1.85 1.85 2.2 2.2 mA Cdrv = 1 nF, VFB = 3 V, 65 kHz Cdrv = 1 nF, VFB = 3 V, 100 kHz ICC2 ICC2 1.8 2.3 2.6 2.9 3.0 3.5 ICC3 0.67 0.9 1.13 ICC4 0.3 0.6 0.9 Internal current consumption (Note 5) Off mode (skip or before start−up) Fault mode (fault or latch) BROWN−OUT Brown−Out thresholds VHV going up VHV going down VHV(start) VHV(stop) 102 94 111 103 120 112 V Brown−Out thresholds (AL/BL Versions) VHV going up VHV going down VHV(start) VHV(stop) 92 84 101 93 110 102 V tHV 43 − 86 ms VHV(hyst) 1.5 3.5 5 V Timer duration for line cycle drop−out X2 DISCHARGE Comparator hysteresis observed at HV pin HV signal sampling period Tsample − 1.0 − ms Timer duration for no line detection tDET 21 32 43 ms Discharge timer duration tDIS 21 32 43 ms fOSC 58 87 65 100 72 109 kHz tONmax(65kHz) tONmax(100kHz) 11.5 7.5 12.3 8.0 13.1 8.5 ms OSCILLATOR Oscillator frequency Maximum on time for TJ = 25°C to +125°C only fOSC = 65 kHz fOSC = 100 kHz 5. Internal supply current only, currents sourced via FB pin is not included (current is flowing in GND pin only). 6. Guaranteed by design. 7. CS pin source current is a sum of Ibias and IOPC, thus at VHV = 125 V is observed the Ibias only, because IOPC is switched off. www.onsemi.com 5 NCP1246 ELECTRICAL CHARACTERISTICS (For typical values TJ = 25°C, for min/max values TJ = −40°C to +125°C, VHV = 125 V, VCC = 11 V unless otherwise noted) Characteristics Test Condition Symbol Min Typ Max Unit Maximum on time fOSC = 65 kHz fOSC = 100 kHz tONmax(65kHz) tONmax(100kHz) 11.3 7.4 12.3 8.0 13.1 8.5 ms Maximum duty cycle (corresponding to maximum on time at maximum switching frequency) fOSC = 65 kHz fOSC = 100 kHz DMAX − 80 − % Frequency jittering amplitude, in percentage of FOSC Ajitter ±4 ±6 ±8 % Frequency jittering modulation frequency Fjitter 85 125 165 Hz Feedback voltage threshold below which frequency foldback starts VFB(foldS) 1.8 2.0 2.2 V Feedback voltage threshold below which frequency foldback is complete VFB(foldE) 0.8 0.9 1.0 V VFB = Vskip(in) + 0.1 fOSC(min) 23 27 32 kHz Rise time, 10 to 90% of VCC VCC = VCC(min) + 0.2 V, CDRV = 1 nF trise − 40 70 ns Fall time, 90 to 10% of VCC VCC = VCC(min) + 0.2 V, CDRV = 1 nF tfall − 40 70 ns Current capability VCC = VCC(min) + 0.2 V, CDRV = 1 nF DRV high, VDRV = 0 V DRV low, VDRV = VCC OSCILLATOR FREQUENCY FOLDBACK Minimum switching frequency OUTPUT DRIVER mA IDRV(source) IDRV(sink) − − 500 800 − − VCC = VCCmax – 0.2 V, DRV high, RDRV = 33 kW, Cload = 220 pF VDRV(clamp) 11 13.5 16 V VCC = VCC(min) + 0.2 V, RDRV = 33 kW, DRV high VDRV(drop) − − 1 V Input Pull−up Current VCS = 0.7 V Ibias − 1 − mA Maximum internal current setpoint VFB > 3.5 V VILIM 0.66 0.70 0.74 V Propagation delay from VIlimit detection to DRV off VCS = VILIM tdelay − 80 110 ns tLEB 200 250 320 ns VCS(stop) 0.95 1.05 1.15 V tBCS 90 120 150 ns tSSTART 8 2.8 11 4.0 14 5.2 ms VI(freeze) 275 300 325 mV Scomp(65kHz) Scomp(100kHz) − − −32.5 −50 − − mV / ms RFB(up) 15 20 25 kW Clamping voltage (maximum gate voltage) High−state voltage drop CURRENT SENSE Leading Edge Blanking Duration for VILIM Threshold for immediate fault protection activation Leading Edge Blanking Duration for VCS(stop) (Note 6) Soft−start duration From 1st pulse to VCS = VILIM AL/BL Versions Frozen current setpoint INTERNAL SLOPE COMPENSATION Slope of the compensation ramp FEEDBACK Internal pull−up resistor TJ = 25°C 5. Internal supply current only, currents sourced via FB pin is not included (current is flowing in GND pin only). 6. Guaranteed by design. 7. CS pin source current is a sum of Ibias and IOPC, thus at VHV = 125 V is observed the Ibias only, because IOPC is switched off. www.onsemi.com 6 NCP1246 ELECTRICAL CHARACTERISTICS (For typical values TJ = 25°C, for min/max values TJ = −40°C to +125°C, VHV = 125 V, VCC = 11 V unless otherwise noted) Characteristics Test Condition Symbol Min Typ Max Unit KFB 4.7 5 5.3 − VFB(ref) 4.5 5 5.5 V VFB(freeze) 1.35 1.5 1.65 V VFB going down VFB going up Vskip(in) Vskip(out) 0.63 0.72 0.70 0.80 0.77 0.88 V The voltage above which the part enters the on mode VCC > VCC(off), VHV = 60 V VON − 2.2 − V The voltage below which the part enters the off mode VCC > VCC(off) VOFF 0.35 0.40 0.45 V VCC > VCC(off), VHV = 60 V VHYST 500 − − mV Pull−up current in off mode VCC > VCC(off) IOFF − 5 − mA Go To Off mode timer VCC > VCC(off) tGTOM 100 150 300 ms tfault 108 128 178 ms tautorec 0.85 1.00 1.35 s KOPC − 0.54 − mA / V FEEDBACK VFB to internal current setpoint division ratio Internal pull−up voltage on the FB pin (Note 6) Feedback voltage below which the peak current is frozen SKIP CYCLE MODE Feedback voltage thresholds for skip mode REMOTE CONTROL ON FB PIN Minimum hysteresis between the VON and VOFF OVERLOAD PROTECTION Fault timer duration Autorecovery mode latch−off time duration OVERPOWER PROTECTION VHV to IOPC conversion ratio Current flowing out of CS pin (Note 7) VHV = 125 V VHV = 162 V VHV = 325 V VHV = 365 V IOPC(125) IOPC(162) IOPC(325) IOPC(365) − − − 105 0 20 110 130 − − − 150 mA FB voltage above which IOPC is applied VHV = 365 V VFB(OPCF) 2.12 2.35 2.58 V FB voltage below which is no IOPC applied VHV = 365 V VFB(OPCE) − 2.15 − V High threshold VLatch going up VOVP 2.35 2.5 2.65 V Low threshold VLatch going down VOTP 0.76 0.8 0.84 LATCH−OFF INPUT Current source for direct NTC connection During normal operation During soft−start VLatch = 0 V Blanking duration on high latch detection 65 kHz version 100 kHz version INTC INTC(SSTART) 65 130 95 190 105 210 tLatch(OVP) 35 20 50 35 70 50 ms tLatch(OTP) − 350 − ms ILatch = 0 mA ILatch = 1 mA Vclamp0(Latch) Vclamp1(Latch) 1.0 1.8 1.2 2.4 1.4 3.0 V TJ going up TTSD − 150 − °C TJ going down TTSD(HYS) − 30 − °C Blanking duration on low latch detection Clamping voltage V mA TEMPERATURE SHUTDOWN Temperature shutdown Temperature shutdown hysteresis 5. Internal supply current only, currents sourced via FB pin is not included (current is flowing in GND pin only). 6. Guaranteed by design. 7. CS pin source current is a sum of Ibias and IOPC, thus at VHV = 125 V is observed the Ibias only, because IOPC is switched off. Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product performance may not be indicated by the Electrical Characteristics if operated under different conditions. www.onsemi.com 7 NCP1246 TYPICAL CHARACTERISTIC 32 40 38 30 36 Istart(off) (mA) VHV(min) (V) 34 32 30 28 26 24 28 26 24 22 22 20 −50 −25 0 25 50 75 100 20 −50 125 0 25 50 75 100 125 TEMPERATURE (°C) Figure 3. Minimum Current Source Operation VHV(min) Figure 4. Off−State Leakage Current Istart(off) 50 8.8 45 8.7 IHV(off) @ VHV = 325 V 8.6 35 Istart2 (mA) 40 IHV(off) (mA) −25 TEMPERATURE (°C) IHV(off) @ VHV = 141 V 8.5 8.4 30 8.3 25 8.2 −25 0 25 50 75 100 8.1 −50 125 −25 0 25 50 75 100 TEMPERATURE (°C) TEMPERATURE (°C) Figure 5. Off−Mode HV Supply Current IHV(off) Figure 6. High Voltage Startup Current Flowing Out of VCC Pin Istart2 120 120 118 118 116 116 114 114 VHV(stop) (V) VHV(start) (V) 20 −50 112 110 108 112 110 108 106 106 104 104 102 102 100 −50 −25 0 25 50 75 100 125 125 100 −50 −25 0 25 50 75 100 125 TEMPERATURE (°C) TEMPERATURE (°C) Figure 7. Brown−out Device Start Threshold VHV(start) Figure 8. Brown−out Device Stop Threshold VHV(stop) www.onsemi.com 8 NCP1246 0.75 310 0.74 308 0.73 306 0.72 304 VI(freeze) (mV) VILIM (V) TYPICAL CHARACTERISTIC 0.71 0.70 0.69 302 300 298 0.68 296 0.67 294 0.66 292 0.65 −50 −25 0 25 50 75 100 290 −50 125 −25 0 25 50 75 100 125 TEMPERATURE (°C) TEMPERATURE (°C) Figure 9. Maximum Internal Current Setpoint VILIM Figure 10. Frozen Current Setpoint VI(freeze) for the Light Load Operation 110 1.15 1.13 100 1.11 90 1.07 tdelay (ns) VCS(stop) (V) 1.09 1.05 1.03 1.01 80 70 60 0.99 50 0.97 0.95 −50 −25 0 25 50 75 100 40 −50 125 −25 0 25 50 75 100 TEMPERATURE (°C) TEMPERATURE (°C) Figure 11. Threshold for Immediate Fault Protection Activation VCS(stop) Figure 12. Propagation Delay tdelay 125 130 300 290 125 280 IOPC(365) (mA) tLEB (ns) 270 260 250 240 230 220 120 115 110 105 210 200 −50 −25 0 25 50 75 100 100 −50 125 −25 0 25 50 75 100 TEMPERATURE (°C) TEMPERATURE (°C) Figure 13. Leading Edge Blanking Duaration tLEB Figure 14. Maximum Overpower Compensating Current IOPC(365) Flowing Out of CS Pin www.onsemi.com 9 125 NCP1246 24 5.20 23 5.15 22 5.10 5.05 21 VFB(ref) (V) RFB(up) (kW) TYPICAL CHARACTERISTIC 20 19 18 5.00 4.95 4.90 4.85 17 4.80 16 4.75 15 −50 −25 0 25 50 75 100 4.70 −50 125 −25 0 25 50 75 100 TEMPERATURE (°C) TEMPERATURE (°C) Figure 15. FB Pin Internal Pull−up Resistor RFB(up) Figure 16. FB Pin Open Voltage VFB(ref) 125 0.85 2.65 0.84 2.60 0.83 0.82 VOTP (V) VOVP (V) 2.55 2.50 2.45 0.81 0.80 0.79 0.78 0.77 2.40 0.76 −25 0 25 50 75 100 0.75 −50 125 0 25 50 75 100 TEMPERATURE (°C) Figure 17. Latch Pin High Threshold VOVP Figure 18. Latch Pin Low Threshold VOTP 110 220 105 210 100 200 95 90 85 180 170 160 75 150 −25 0 25 50 75 100 125 125 190 80 70 −50 −25 TEMPERATURE (°C) INTC(SSTART) (mA) INTC (mA) 2.35 −50 140 −50 −25 0 25 50 75 100 125 TEMPERATURE (°C) TEMPERATURE (°C) Figure 19. Current INTC Sourced from the Latch Pin, Allowing Direct NTC Connection Figure 20. Current INTC(SSTART) Sourced from the Latch Pin, During Soft−Start www.onsemi.com 10 NCP1246 70 100 69 99 68 98 67 97 fOSC (kHz) fOSC (kHz) TYPICAL CHARACTERISTIC 66 65 64 96 95 94 63 93 62 92 61 91 60 −50 −25 0 25 50 75 100 90 −50 125 −25 0 25 50 75 100 TEMPERATURE (°C) TEMPERATURE (°C) Figure 21. Oscillator fOSC for the 65 kHz Version Figure 22. Oscillator fOSC for the 100 kHz Version 12.8 125 8.4 12.7 8.3 12.6 8.2 tONmax (ms) tONmax (ms) 12.5 12.4 12.3 12.2 8.1 8.0 12.1 7.9 12.0 11.9 −50 −25 0 25 50 75 100 7.8 −50 125 −25 0 25 50 75 100 125 TEMPERATURE (°C) TEMPERATURE (°C) Figure 23. Maximum ON Time tONmax for the 65 kHz Version Figure 24. Maximum ON Time tONmax for the 100 kHz Version 85 30 84 29 83 28 fOSC(min) (ms) DMAX (%) 82 81 80 79 27 26 25 78 24 77 23 76 75 −50 −25 0 25 50 75 TEMPERATURE (°C) 100 125 22 −50 Figure 25. Maximum Duty Ratio DMAX −25 0 25 50 75 TEMPERATURE (°C) 100 Figure 26. Minimum Switching Frequency fOSC(min) www.onsemi.com 11 125 NCP1246 TYPICAL CHARACTERISTIC 2.20 1.00 2.15 0.98 0.96 0.94 VFB(foldE) (V) VFB(foldS) (V) 2.10 2.05 2.00 1.95 0.90 0.88 0.86 1.90 0.84 1.85 1.80 −50 0.92 0.82 −25 0 25 50 75 100 125 0.80 −50 −25 0 25 TEMPERATURE (°C) Figure 27. FB Pin Voltage Below Which Frequency Foldback Starts VFB(foldS) 0.88 0.75 0.86 Vskip(on) (V) Vskip(in) (V) 0.71 0.69 0.67 125 0.82 0.80 0.78 0.76 0.65 0.74 −25 0 25 50 75 100 125 0.72 −50 −25 TEMPERATURE (°C) 2.35 2.50 2.30 2.45 2.25 VFB(OPCE) (V) 2.40 2.55 2.40 2.35 2.30 100 125 2.10 2.20 2.00 2.15 1.95 50 75 2.15 2.05 25 50 2.20 2.25 0 25 Figure 30. FB Pin Skip−Out Level Vskip(out) 2.60 −25 0 TEMPERATURE (°C) Figure 29. FB Pin Skip−In Level Vskip(in) VFB(OPCF) (V) 100 0.84 0.73 2.10 −50 75 Figure 28. FB Pin Voltage Below Which Frequency Foldback Complete VFB(foldE) 0.77 0.63 −50 50 TEMPERATURE (°C) 75 100 125 1.90 −50 TEMPERATURE (°C) −25 0 25 50 75 100 TEMPERATURE (°C) Figure 31. FB Pin Level VFB(OPCF) Above Which is the Overpower Compensation Applied Figure 32. FB Pin Level VFB(OPCE) Below Which is No Overpower Compensation Applied www.onsemi.com 12 125 NCP1246 13.0 11.5 12.8 11.3 12.6 11.1 12.4 10.9 VCC(min) (V) VCC(on) (V) TYPICAL CHARACTERISTIC 12.2 12.0 11.8 10.7 10.5 10.3 11.6 10.1 11.4 9.9 11.2 9.7 11.0 −50 −25 0 25 50 75 100 9.5 −50 125 −25 TEMPERATURE (°C) 0 25 50 75 100 125 TEMPERATURE (°C) Figure 33. VCC Turn−on Threshold Level, VCC Going Up HV Current Source Stop Threshold VCC(on) Figure 34. HV Current Source Restart Threshold VCC(min) 9.4 7.3 7.2 9.2 7.1 VCC(reset) (V) VCC(off) (V) 9.0 8.8 8.6 7.0 6.9 6.8 6.7 8.4 6.6 8.2 6.5 8.0 −50 −25 0 25 50 75 100 6.4 −50 125 −25 TEMPERATURE (°C) 25 50 75 100 125 TEMPERATURE (°C) Figure 35. VCC Turn−off Threshold (UVLO) VCC(off) Figure 36. VCC Decreasing Level at Which the Internal Logic Resets VCC(reset) 2.0 3.2 ICC1(100kHz) 1.9 ICC2(100kHz) 3.0 1.9 2.8 ICC2 (mA) ICC1 (mA) 0 ICC1(65kHz) 1.8 1.8 2.4 1.7 2.2 1.7 −50 −25 0 25 50 TEMPERATURE (°C) 75 100 125 ICC2(65kHz) 2.6 2.0 −50 Figure 37. Internal Current Consumption when DRV Pin is Unloaded −25 0 25 50 75 TEMPERATURE (°C) 100 125 Figure 38. Internal Current Consumption when DRV Pin is Loaded by 1 nF www.onsemi.com 13 NCP1246 TYPICAL CHARACTERISTIC 4.0 1.10 3.9 1.08 1.06 3.8 Tsample (ms) VHV(hyst) (V) 1.04 3.7 3.6 3.5 1.02 1.00 0.98 0.96 3.4 0.94 3.3 0.92 3.2 −50 −25 0 25 50 75 100 0.90 −50 125 0 25 50 75 100 125 TEMPERATURE (°C) TEMPERATURE (°C) Figure 39. X2 Discharge Comparator Hysteresis Observed at HV Pin VHV(hyst) Figure 40. HV Signal Sampling Period Tsample 2.6 0.45 2.6 0.44 0.43 2.5 0.42 VOFF (V) 2.5 VON (V) −25 2.4 2.4 0.41 0.40 0.39 0.38 2.3 0.37 2.3 0.36 2.2 −50 −25 0 25 50 75 100 0.35 −50 125 −25 0 25 50 75 100 125 TEMPERATURE (°C) TEMPERATURE (°C) Figure 41. FB Pin Voltage Level Above Which is Entered On Mode VON Figure 42. FB Pin Voltage Level Below Which is Entered Off Mode VOFF 300 150 280 145 260 240 tGTOM (ms) tfault (ms) 140 135 130 220 200 180 160 140 125 120 120 −50 −25 0 25 50 75 100 125 100 −50 −25 0 25 50 75 100 TEMPERATURE (°C) TEMPERATURE (°C) Figure 43. Fault Timer Duration tfault Figure 44. Go To Off Mode Timer Duration tGTOM www.onsemi.com 14 125 NCP1246 APPLICATION INFORMATION Functional Description For loads that are between approximately 32% and 10% of full rated power, the converter operates in frequency foldback mode (FFM). If the feedback pin voltage is lower than 1.5 V the peak switch current is kept constant and the output voltage is regulated by modulating the switching frequency for a given and fixed input voltage VHV. Effectively, operation in FFM results in the application of constant volt−seconds to the flyback transformer each switching cycle. Voltage regulation in FFM is achieved by varying the switching frequency in the range from 65 kHz (or 100 kHz) to 27 kHz. For extremely light loads (below approximately 6% full rated power), the converter is controlled using bursts of 27 kHz pulses. This mode is called as skip mode. The FFM, keeping constant peak current and skip mode allows design of the power supplies with increased efficiency under the light loading conditions. Keep in mind that the aforementioned boundaries of steady−state operation are approximate because they are subject to converter design parameters. The NCP1246 includes all necessary features to build a safe and efficient power supply based on a fixed−frequency flyback converter. The NCP1246 is a multimode controller as illustrated in Figure 45. The mode of operation depends upon line and load condition. Under all modes of operation, the NCP1246 terminates the DRV signal based on the switch current. Thus, the NCP1246 always operates in current mode control so that the power MOSFET current is always limited. Under normal operating conditions, the FB pin commands the operating mode of the NCP1246 at the voltage thresholds shown in Figure 45. At normal rated operating loads (from 100% to approximately 33% full rated power) the NCP1246 controls the converter in fixed frequency PWM mode. It can operate in the continuous conduction mode (CCM) or discontinuous conduction mode (DCM) depending upon the input voltage and loading conditions. If the controller is used in CCM with a wide input voltage range, the duty−ratio may increase up to 50%. The build−in slope compensation prevents the appearance of sub−harmonic oscillations in this operating area. Low consumption off mode OFF ON Fixed Ipeak 0V PWM at fOSC FFM Skip mode 0.4 V 0.7 V 1.1 V 0.8 V 1.5V 2.0 V 2.2 V 3.5 V VFB Figure 45. Mode Control with FB pin voltage decreases below the 0.4 V the controller will enter the low consumption off mode. The controller can start if the FB pin voltage increases above the 2.2 V level. See the detailed status diagrams for the both versions fully latched A and the autorecovery B on the following figures. The basic status of the device after wake–up by the VCC is the off mode and mode is used for the overheating protection mode if the thermal shutdown protection is activated. There was implemented the low consumption off mode allowing to reach extremely low no load input power. This mode is controlled by the FB pin and allows the remote control (or secondary side control) of the power supply shut−down. Most of the device internal circuitry is unbiased in the low consumption off mode. Only the FB pin control circuitry and X2 cap discharging circuitry is operating in the low consumption off mode. If the voltage at feedback pin www.onsemi.com 15 NCP1246 VHV > VHV(NOAC) < VOFF) * GTOMtimer*(VCC > VCCoff) BO+TSD Reset Latch=0 VCC fault Soft Start (VCC < VCCoff (VCC > VCCon)*BO Efficient operating mode BO+TSD Stop VCC > VCCoff SSend Skip in Running Skip mode Dynamic Self−Supply Skip out (if not enoughgh auxiliary voltage is present) www.onsemi.com Extra Low Consumption (VFB (VFB > VON)*Latch BO Latch Latch=1 (VCC < VCCoff 16 Off Mode Latch=X (VFB > VON)*Latch No AC AC present + discharged BO OVP+OTP+VCCovp+VCSstop (VILIM +MaxDC)*tfault X2 cap Discharge Latch=0 VCC > VCCreset Power On Reset Latch=0 Regulated Self−Supply VCC > VCCreset Figure 46. Operating Status Diagram for the Fully Latched Version A of the Device NCP1246 VHV > V VCC > VCCoff (VCC > VCCon)*BO Efficient operating mode BO+TSD Stop BO Autorecovery Latch AutoRec=1 Soft Start VCC fault VCC < SSend Skip in VCCoff Running Skip mode present) Skip out Dynamic Self−Supply (if not enough auxiliary voltage is www.onsemi.com BO+TSD Reset Latch=0 AutoRec=0 BO+tautorec Extra Low Consumption (VFB > VON)*Latch*AutoRec BO Latch Latch=1 VCSstop VCC < VCCoff 17 Off Mode Latch=X AutoRec=X BO OVP+OTP+VCCovp (VFB > VON)*AutoRec (VILIM + MaxDC)*tfault (VFB < VOFF) * GTOMtimer*(VCC > VCCoff) AC present + discharged (VFB > VON)*Latch No AC HV(NOAC) X2 cap Discharge Latch=0 AutoRec=0 VCC < VCCreset Power On Reset Latch=0 AutoRec=0 Regulated Self−Supply VCC > VCCreset Figure 47. Operating Status Diagram for the Autorecovery Version B of the Device NCP1246 Even though the Dynamic Self−Supply is able to maintain the VCC voltage between VCC(on) and VCC(min) by turning the HV start−up current source on and off, it can only be used in light load condition, otherwise the power dissipation on the die would be too much. As a result, an auxiliary voltage source is needed to supply VCC during normal operation. The Dynamic Self−Supply is useful to keep the controller alive when no switching pulses are delivered, e.g. in brown−out condition, or to prevent the controller from stopping during load transients when the VCC might drop. The NCP1246 accepts a supply voltage as high as 28 V, with an overvoltage threshold VCC(ovp) that latches the controller off. The information about the fault (permanent Latch or Autorecovery) is kept during the low consumption off mode due the safety reason. The reason is not to allow unlatch the device by the remote control being in off mode. Start−up of the Controller At start−up, the current source turns on when the voltage on the HV pin is higher than VHV(min), and turns off when VCC reaches VCC(on), then turns on again when VCC reaches VCC(min), until the input voltage is high enough to ensure a proper start−up, i.e. when VHV reaches VHV(start). The controller actually starts the next time VCC reaches VCC(on). The controller then delivers pulses, starting with a soft−start period tSSTART during which the peak current linearly increases before the current−mode control takes over. VHV V HV(start) V HV(min) Waits next VCC(on) before starting time VCC V CC(on) V CC(min) HV current source = I start1 HV current source = Istart2 V CC(inhibit) time DRV Figure 48. VCC Start−up Timing Diagram www.onsemi.com 18 time NCP1246 For safety reasons, the start−up current is lowered when VCC is below VCC(inhibit), to reduce the power dissipation in case the VCC pin is shorted to GND (in case of VCC capacitor failure, or external pull−down on VCC to disable the controller). There is only one condition for which the current source doesn’t turn on when VCC reaches VCC(inhibit): the voltage on HV pin is too low (below VHV(min)). threshold and an autorecovery brown−out protection; both of them independent of the ripple on the input voltage. It is allowed only to work with an unfiltered, rectified ac input to ensure the X2 capacitor discharge function as well, which is described in following. The brown−out protection thresholds are fixed, but they are designed to fit most of the standard ac−dc conversion applications. When the input voltage goes below VHV(stop), a brown−out condition is detected, and the controller stops. The HV current source maintains VCC at VCC(min) level until the input voltage is back above VHV(start). HV Sensing of Rectified AC Voltage The NCP1246 features on its HV pin a true ac line monitoring circuitry. It includes a minimum start−up HV timer elapsed VHV VHV(start) VHV(stop) time HV stop tHV Brown-out detected Waits next VccON before starting VCC time VCC(on) VCC(min) Brown-out condition resets the Internal Latch DRV time time Figure 49. Ac Line Drop−out Timing Diagram When VHV crosses the VHV(start) threshold, the controller can start immediately. When it crosses VHV(stop), it triggers a timer of duration tHV, this ensures that the controller doesn’t stop in case of line cycle drop−out. www.onsemi.com 19 NCP1246 X2 Cap Discharge Feature In case of the dc signal presence on the high voltage input, the direct sample of the high voltage obtained via the high voltage sensing structure and the delayed sample of the high voltage are equivalent and the comparator produces the low level signal during the presence of this signal. No edges are present at the output of the comparator, that’s why the detection timer is not reset and dc detect signal appears. The minimum detectable slope by this ac detector is given by the ration between the maximum hysteresis observed at HV pin VHV(hyst),max and the sampling time: The X2 capacitor discharging feature is offered by usage of the NCP1246. This feature save approx. 16 mW – 25 mW input power depending on the EMI filter X2 capacitors volume and it saves the external components count as well. The discharge feature is ensured via the start−up current source with a dedicated control circuitry for this function. The X2 capacitors are being discharged by current defined as Istart2 when this need is detected. There is used a dedicated structure called ac line unplug detector inside the X2 capacitor discharge control circuitry. See the Figure 50 for the block diagram for this structure and Figures 51, 52, 53 and 54 for the timing diagrams. The basic idea of ac line unplug detector lies in comparison of the direct sample of the high voltage obtained via the high voltage sensing structure with the delayed sample of the high voltage. The delayed signal is created by the sample & hold structure. The comparator used for the comparison of these signals is without hysteresis inside. The resolution between the slopes of the ac signal and dc signal is defined by the sampling time TSAMPLE and additional internal offset NOS. These parameters ensure the noise immunity as well. The additional offset is added to the picture of the sampled HV signal and its analog sum is stored in the C1 storage capacitor. If the voltage level of the HV sensing structure output crosses this level the comparator CMP output signal resets the detection timer and no dc signal is detected. The additional offset NOS can be measured as the VHV(hyst) on the HV pin. If the comparator output produces pulses it means that the slope of input signal is higher than set resolution level and the slope is positive. If the comparator output produces the low level it means that the slope of input signal is lower than set resolution level or the slope is negative. There is used the detection timer which is reset by any edge of the comparator output. It means if no edge comes before the timer elapses there is present only dc signal or signal with the small ac ripple at the HV pin. This type of the ac detector detects only the positive slope, which fulfils the requirements for the ac line presence detection. S min + V HV(hyst),max (eq. 1) T sample Than it can be derived the relationship between the minimum detectable slope and the amplitude and frequency of the sinusoidal input voltage: V max + V HV(hyst),max 2 @ p @ f @ T sample + 5 2 @ p @ 35 @ 1 @ 10 −3 (eq. 2) + 22.7 V The minimum detectable AC RMS voltage is 16 V at frequency 35 Hz, if the maximum hysteresis is 5 V and sampling time is 1 ms. The X2 capacitor discharge feature is available in any controller operation mode to ensure this safety feature. The detection timer is reused for the time limiting of the discharge phase, to protect the device against overheating. The discharging process is cyclic and continues until the ac line is detected again or the voltage across the X2 capacitor is lower than VHV(min). This feature ensures to discharge quite big X2 capacitors used in the input line filter to the safe level. It is important to note that it is not allowed to connect HV pin to any dc voltage due this feature. e.g. directly to bulk capacitor. During the HV sensing or X2 cap discharging the VCC net is kept above the VCC(off) voltage by the Self−Supply in any mode of device operation to supply the control circuitry. During the discharge sequence is not allowed to start−up the device. www.onsemi.com 20 NCP1246 Figure 50. The ac Line Unplug Detector Structure Used for X2 Capacitor Discharge System Figure 51. The ac Line Unplug Detector Timing Diagram www.onsemi.com 21 NCP1246 Figure 52. The ac Line Unplug Detector Timing Diagram Detail with Noise Effects www.onsemi.com 22 NCP1246 Figure 53. HV Pin ac Input Timing Diagram with X2 Capacitor Discharge Sequence When the Application is Unplugged Under Extremely Low Line Condition www.onsemi.com 23 NCP1246 Figure 54. HV Pin ac Input Timing Diagram with X2 Capacitor Discharge Sequence When the Application is Unplugged Under High Line Condition The Low Consumption Off Mode Only the X2 cap discharge and Self−Supply features is enabled in the low consumption off mode. The X2 cap discharging feature is enable due the safety reasons and the Self−Supply is enabled to keep the VCC supply, but only very low VCC consumption appears in this mode. Any other features are disabled in this mode. The information about the latch status of the device is kept in the low consumption off mode and this mode is used for the TSD protection as well. The protection timer GoToOffMode tGTOM is used to protect the application against the false activation of the low consumption off mode by the fast drop outs of the FB pin voltage below the 0.4 V level. E.g. in case when is present high FB pin voltage ripple during the skip mode. There was implemented the low consumption off mode allowing to reach extremely low no load input power as described in previous chapters. If the voltage at feedback pin decreases below the 0.4 V the controller enters the off mode. The internal VCC is turned−off, the IC consumes extremely low VCC current and only the voltage at external VCC capacitor is maintained by the Self−Supply circuit. The Self−Supply circuit keeps the VCC voltage at the VCC(reg) level. The supply for the FB pin watch dog circuitry and FB pin bias is provided via the low consumption current sources from the external VCC capacitor. The controller can only start, if the FB pin voltage increases above the 2.2 V level. See Figure 55 for timing diagrams. www.onsemi.com 24 NCP1246 Figure 55. Start−up, Shutdown and AC Line Unplug Time Diagram Oscillator with Maximum On Time and Frequency Jittering The NCP1246 includes an oscillator that sets the switching frequency 65 kHz or 100 kHz depending on the version. The maximum on time is 12.3 ms (for 65 kHz version) or 8 ms (for 100 kHz version) with an accuracy of ±7%. The maximum on time corresponds to maximum duty cycle of the DRV pin is 80% at full switching frequency. In order to improve the EMI signature, the switching frequency jitters ±6 % around its nominal value, with a triangle−wave shape and at a frequency of 125 Hz. This frequency jittering is active even when the frequency is decreased to improve the efficiency in light load condition. Figure 56. Frequency Modulation of the Maximum Switching Frequency www.onsemi.com 25 NCP1246 Low Load Operation Modes: Frequency Foldback Mode (FFM) and Skip Mode frequency foldback mode to provide the natural transformer core anti−saturation protection. The frequency jittering is still active while the oscillator frequency decreases as well. The current setpoint is fixed to 300 mV in the frequency foldback mode if the feedback voltage decreases below the VFB(freeze) level. This feature increases efficiency under the light loads conditions as well. In order to improve the efficiency in light load conditions, the frequency of the internal oscillator is linearly reduced from its nominal value down to fOSC(min). This frequency foldback starts when the voltage on FB pin goes below VFB(foldS), and is complete when VFB reaches VFB(foldE). The maximum on−time duration control is kept during the Figure 57. Frequency Foldback Mode Characteristic Figure 58. Current Setpoint Dependency on the Feedback Pin Voltage When the FB voltage reaches Vskip(in) while decreasing, skip mode is activated: the driver stops, and the internal consumption of the controller is decreased. While VFB is below Vskip(out), the controller remains in this state; but as soon as VFB crosses the skip out threshold, the DRV pin starts to pulse again. www.onsemi.com 26 NCP1246 Figure 59. Skip Mode Timing Diagram Clamped Driver resulting voltage is applied to the CS pin. It is applied to one input of the PWM comparator through a 250 ns LEB block. On the other input the FB voltage divided by 5 sets the threshold: when the voltage ramp reaches this threshold, the output driver is turned off. The maximum value for the current sense is 0.7 V, and it is set by a dedicated comparator. Each time the controller is starting, i.e. the controller was off and starts – or restarts – when VCC reaches VCC(on), a soft−start is applied: the current sense setpoint is increased by 15 discrete steps from 0 (the minimum level can be higher than 0 because of the LEB and propagation delay) until it reaches VILIM (after a duration of tSSTART), or until the FB loop imposes a setpoint lower than the one imposed by the soft−start (the two comparators outputs are OR’ed). The supply voltage for the NCP1246 can be as high as 28 V, but most of the MOSFETs that will be connected to the DRV pin cannot accept more than 20 V on their gate. The driver pin is therefore clamped safely below 16 V. This driver has a typical capability of 500 mA for source current and 800 mA for sink current. Current−Mode Control With Slope Compensation and Soft−Start NCP1246 is a current−mode controller, which means that the FB voltage sets the peak current flowing in the inductance and the MOSFET. This is done through a PWM comparator: the current is sensed across a resistor and the www.onsemi.com 27 NCP1246 Figure 60. Soft−Start Feature In order to allow the NCP1246 to operate in CCM with a duty cycle above 50%, the fixed slope compensation is internally applied to the current−mode control. The slope appearing on the internal voltage setpoint for the PWM comparator is −32.5 mV/ms typical for the 65 kHz version, and −50 mV/ms for the 100 kHz version. The slope compensation can be observable as a value of the peak current at CS pin. The internal slope compensation circuitry uses a sawtooth signal synchronized with the internal oscillator is subtracted from the FB voltage divided by KFB. Under some conditions, like a winding short−circuit for instance, not all the energy stored during the on time is transferred to the output during the off time, even if the on time duration is at its minimum (imposed by the propagation delay of the detector added to the LEB duration). As a result, the current sense voltage keeps on increasing above VILIM, because the controller is blind during the LEB blanking time. Dangerously high current can grow in the system if nothing is done to stop the controller. That’s what the additional comparator, that senses when the current sense voltage on CS pin reaches VCS(stop) ( = 1.5 x VILIM ), does: as soon as this comparator toggles, the controller immediately enters the protection mode. www.onsemi.com 28 NCP1246 Figure 61. Slope Compensation Block Diagram Figure 62. Slope Compensation Timing Diagram Internal Overpower Protection Unfortunately, due to the inherent propagation delay of the logic, the actual peak current is higher at high input voltage than at low input voltage, leading to a significant difference in the maximum output power delivered by the power supply. The power delivered by a flyback power supply is proportional to the square of the peak current in discontinuous conduction mode: P OUT + 1 @ h @ L P @ F SW @ I P 2 2 (eq. 3) www.onsemi.com 29 NCP1246 Figure 63. Needs for Line Compensation For True Overpower Protection would be in the same order of magnitude. Therefore the compensation current is only added when the FB voltage is higher than VFB(OPCE). However, because the HV pin is being connected to ac voltage, there is needed an additional circuitry to read or at least closely estimate the actual voltage on the bulk capacitor. To compensate this and have an accurate overpower protection, an offset proportional to the input voltage is added on the CS signal by turning on an internal current source: by adding an external resistor in series between the sense resistor and the CS pin, a voltage offset is created across it by the current. The compensation can be adjusted by changing the value of the resistor. But this offset is unwanted to appear when the current sense signal is small, i.e. in light load conditions, where it Figure 64. Overpower Protection Current Relation to Feedback Voltage www.onsemi.com 30 NCP1246 Figure 65. Overpower Protection Current Relation to Peak of Rectified Input Line AC voltage Figure 66. Block Schematic of Overpower Protection Circuit line unplug detector. The sensed HV pin voltage peak value is validated when no HV edges from comparator are present after last falling edge during two sample clocks. See Figure 67 for details. A 3 bit A/D converter with the peak detector senses the ac input, and its output is periodically sampled and reset, in order to follow closely the input voltage variations. The sample and reset events are given by the output from the ac www.onsemi.com 31 NCP1246 Overcurrent Protection with Fault timer release are the brown−out condition or the VCC power on reset. The timer is reset when the CS setpoint goes back below VILIM before the timer elapses. The fault timer is also started if the driver signal is reset by the maximum on time. The controller also enters the same protection mode if the voltage on the CS pin reaches 1.5 times the maximum internal setpoint VCS(stop) (allows to detect winding short−circuits) or there appears low VCC supply. See Figures 68 and 69 for the timing diagram. In autorecovery mode if the fault has gone, the supply resumes operation; if not, the system starts a new burst cycle. The overload protection depends only on the current sensing signal, making it able to work with any transformer, even with very poor coupling or high leakage inductance. When an overcurrent occurs on the output of the power supply, the FB loop asks for more power than the controller can deliver, and the CS setpoint reaches VILIM. When this event occurs, an internal tfault timer is started: once the timer times out, DRV pulses are stopped and the controller is either latched off (latched protection, option A) or this latch can be released in autorecovery mode (option B), the controller tries to restart after tautorec. Other possibilities of the latch www.onsemi.com 32 NCP1246 VHVSAMPLE TSAMPLE VHV(hyst) time 1st HV edge resets the watch dog and starts the peak detection of HV pin signal Comparator Output time Sample clock time Watch dog signal 2nd sample clock pulse after last HV edge initiates the watch dog signal 2nd sample clock pulse after last HV edge initiates the watch dog signal time Peak detector Reset Reset Sample Sample time IOPC time Figure 67. Overpower Compensation Timing Diagram www.onsemi.com 33 NCP1246 PROTECTION MODES AND THE LATCH MODE RELEASES Event Timer Protection Next Device Status Release to Normal Operation Mode Overcurrent VILIM > 0.7 V Fault timer Latch Autorecovery – B version Brown−out VCC < VCC(reset) Maximum on time Fault timer Latch Autorecovery – B version Brown−out VCC < VCC(reset) Winding short Vsense > VCS(stop) Immediate reaction Latch Autorecovery – B version Brown−out VCC < VCC(reset) Low supply VCC < VCC(off) 10 ms timer Latch Autorecovery – B version Brown−out VCC < VCC(reset) External OTP, OVP 55 ms (35 ms at 100 kHz) Latch Brown−out VCC < VCC(reset) High supply VCC > VCC(ovp) 10 ms timer Latch Brown−out VCC < VCC(reset) Brown−out VHV < VHV(stop) HV timer Device stops (VHV > VHV(start))&( VCC > VCC(on)) Internal TSD 10 ms timer Device stops, HV start−up current source stops (VHV > VHV(start)) & ( VCC > VCC(on)) & TSDb Off mode VFB < VOFF 150 ms timer Device stops and internal VCC is turned off (VHV > VHV(start)) & ( VCC > VCC(on)) & ( VFB > VON) www.onsemi.com 34 NCP1246 VCC(on) VCC(min) Figure 68. Latched Timer−Based Overcurrent Protection (Option A) www.onsemi.com 35 NCP1246 VCC(on) VCC(min) Figure 69. Timer−Based Protection Mode with Autorecovery Release from Latch−off (Option B) www.onsemi.com 36 NCP1246 Latch−Off Input Figure 70. Latch Detection Schematic The Latch pin is dedicated to the latch−off function: it includes two levels of detection that define a working window, between a high latch and a low latch: within these two thresholds, the controller is allowed to run, but as soon as either the low or the high threshold is crossed, the controller is latched off. The lower threshold is intended to be used with an NTC thermistor, thanks to an internal current source INTC. An active clamp prevents the voltage from reaching the high threshold if it is only pulled up by the INTC current. To reach the high threshold, the pull−up current has to be higher than the pull−down capability of the clamp (typically 1.5 mA at VOVP). To avoid any false triggering, spikes shorter than 50 ms (for the high latch and 65 kHz version) or 350 ms (for the low latch) are blanked and only longer signals can actually latch the controller. C LATCH max + t SSTART Reset occurs when a brown−out condition is detected or the VCC is cycled down to a reset voltage, which in a real application can only happen if the power supply is unplugged from the ac line. Upon startup, the internal references take some time before being at their nominal values; so one of the comparators could toggle even if it should not. Therefore the internal logic does not take the latch signal into account before the controller is ready to start: once VCC reaches VCC(on), the latch pin High latch state is taken into account and the DRV switching starts only if it is allowed; whereas the Low latch (typically sensing an over temperature) is taken into account only after the soft−start is finished. In addition, the NTC current is doubled to INTC(SSTART) during the soft−start period, to speed up the charging of the Latch pin capacitor. The maximum value of Latch pin capacitor is given by the following formula (The standard start−up condition is considered and the NTC current is neglected): min @ I NTC(SSTART) min V clamp0 min + 8.0 @ 10 −3 @ 130 @ 10 −6 F + 1.04 mF (eq. 4) 1.0 + 364 nF(ALVersion) www.onsemi.com 37 NCP1246 VCC(on) VCC(min) Figure 71. Latch Timing Diagram Temperature Shutdown low power consumption. There is kept the VCC supply to keep the TSD information. When the temperature falls below the low threshold, the start−up of the device is enabled again, and a regular start−up sequence takes place. See the status diagrams at the Figures 46 and 47. The NCP1246 includes a temperature shutdown protection with a trip point typically at 150°C and the typical hysteresis of 30°C. When the temperature rises above the high threshold, the controller stops switching instantaneously, and goes to the off mode with extremely ORDERING INFORMATION 5 Ordering Part No. Overload Protection Switching Frequency NCP1246AD065R2G Latched 65 kHz NCP1246BD065R2G Autorecovery 65 kHz NCP1246ALD065R2G Latched 65 kHz NCP1246BLD065R2G Autorecovery 65 kHz NCP1246AD100R2G Latched 100 kHz NCP1246BD100R2G Autorecovery 100 kHz NCP1246ALD100R2G Latched 100 kHz NCP1246BLD100R2G Autorecovery 100 kHz Package Shipping† SOIC−7 (Pb−Free) 2500 / Tape & Reel †For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging Specifications Brochure, BRD8011/D. www.onsemi.com 38 NCP1246 PACKAGE DIMENSIONS SOIC−7 CASE 751U ISSUE E −A− 8 NOTES: 1. DIMENSIONING AND TOLERANCING PER ANSI Y14.5M, 1982. 2. CONTROLLING DIMENSION: MILLIMETER. 3. DIMENSION A AND B ARE DATUMS AND T IS A DATUM SURFACE. 4. DIMENSION A AND B DO NOT INCLUDE MOLD PROTRUSION. 5. MAXIMUM MOLD PROTRUSION 0.15 (0.006) PER SIDE. 5 −B− S 0.25 (0.010) B M M 1 4 DIM A B C D G H J K M N S G C R X 45 _ J −T− SEATING PLANE H 0.25 (0.010) K M D 7 PL M T B S A MILLIMETERS MIN MAX 4.80 5.00 3.80 4.00 1.35 1.75 0.33 0.51 1.27 BSC 0.10 0.25 0.19 0.25 0.40 1.27 0_ 8_ 0.25 0.50 5.80 6.20 INCHES MIN MAX 0.189 0.197 0.150 0.157 0.053 0.069 0.013 0.020 0.050 BSC 0.004 0.010 0.007 0.010 0.016 0.050 0_ 8_ 0.010 0.020 0.228 0.244 S SOLDERING FOOTPRINT* 1.52 0.060 7.0 0.275 4.0 0.155 0.6 0.024 1.270 0.050 SCALE 6:1 mm Ǔ ǒinches *For additional information on our Pb−Free strategy and soldering details, please download the ON Semiconductor Soldering and Mounting Techniques Reference Manual, SOLDERRM/D. ON Semiconductor and are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of SCILLC’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marking.pdf. SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. SCILLC does not convey any license under its patent rights nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur. Should Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the part. SCILLC is an Equal Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner. PUBLICATION ORDERING INFORMATION LITERATURE FULFILLMENT: Literature Distribution Center for ON Semiconductor P.O. Box 5163, Denver, Colorado 80217 USA Phone: 303−675−2175 or 800−344−3860 Toll Free USA/Canada Fax: 303−675−2176 or 800−344−3867 Toll Free USA/Canada Email: [email protected] N. American Technical Support: 800−282−9855 Toll Free USA/Canada Europe, Middle East and Africa Technical Support: Phone: 421 33 790 2910 Japan Customer Focus Center Phone: 81−3−5817−1050 www.onsemi.com 39 ON Semiconductor Website: www.onsemi.com Order Literature: http://www.onsemi.com/orderlit For additional information, please contact your local Sales Representative NCP1246/D