DEVICE SPECIFICATIONS NI PXIe-2748 3 GHz 16 × 1 50 Ω Multiplexer (SP16T) This document lists specifications for the NI PXIe-2748 (NI 2748) multiplexer module. All specifications are subject to change without notice. Visit ni.com/manuals for the most current specifications. ............................................................................ Topology 16 × 1 multiplexer Contents About These Specifications...................................................................................................... 1 Input Characteristics................................................................................................................. 2 RF Performance Characteristics................................................................................................3 Dynamic Characteristics........................................................................................................... 4 Physical Characteristics............................................................................................................ 5 Environment..............................................................................................................................5 Shock and Vibration..................................................................................................................5 Diagrams................................................................................................................................... 5 Accessories................................................................................................................................7 Compliance and Certifications..................................................................................................8 Safety................................................................................................................................ 8 Electromagnetic Compatibility......................................................................................... 8 CE Compliance ................................................................................................................ 9 Online Product Certification............................................................................................. 9 Environmental Management............................................................................................. 9 About These Specifications Specifications characterize the warranted performance of the instrument under the stated operating conditions. Typical Specifications are specifications met by the majority of the instrument under the stated operating conditions and are tested at 23 °C ambient temperature. Typical specifications are not warranted. All voltages are specified in DC, ACpk, or a combination unless otherwise specified. Caution The protection provided by the NI 2748 can be impaired if it is used in a manner not described in this document. Input Characteristics All input characteristics are DC, ACrms, or a combination unless otherwise specified. Maximum ............................................................................ switching voltage 30 V ............................................................................ Maximum switching current 0.5 A (per channel) ............................................................................ Maximum carry current 0.5 A (per channel) Maximum RF power ............................................................................ 10 W Caution The switching power is limited by the maximum switching current and the maximum voltage. Channel-to-common switching power must not exceed 10 W. Note National Instruments recommends against switching active RF signals. As a relay actuates, the channel is momentarily unterminated. Some RF sources can be damaged by reflections if their outputs are not properly terminated. Refer to your RF source documentation for more information. Note Switching active RF signals below 0 dBm may degrade signal integrity and decrease relay life. For more information about switching active RF signals, visit ni.com/info and enter Info Code RFSwitching. Typical DC path resistance .................................................................... Initial <1 Ω End-of-life .................................................................... ≥2 Ω Path resistance is a combination of relay contact resistance and trace resistance. Contact resistance typically remains low for the life of a relay. At the end of relay life, the contact resistance rises rapidly above 1.0 Ω. 2 | ni.com | NI PXIe-2748 Specifications RF Performance Characteristics Characteristic ............................................................................ impedance (Z0) 50 Ω nominal Insertion loss .................................................................... ≤1 GHz 1.5 dB ≤3 GHz .................................................................... 3 dB Voltage standing wave ratio (VSWR) ≤1 .................................................................... GHz 1.4 ≤3 GHz .................................................................... 1.6 Typical isolation ≤1 GHz .................................................................... >60 dB ≤3 GHz .................................................................... >40 dB Typical channel-to-channel skew ............................................................................ <160 ps Refer to the following figures for typical insertion loss, typical VSWR, and typical isolation, respectively. Figure 1. Typical Insertion Loss Frequency (GHz) 0 0.5 1 1.5 2 2.5 3 0.00E+00 Typical Insertion Loss –5.00E–01 –1.00E+00 –1.50E+00 –2.00E+00 –2.50E+00 –3.00E+00 NI PXIe-2748 Specifications | © National Instruments | 3 Figure 2. Typical VSWR 1.50E+00 1.45E+00 1.40E+00 Typical VSWR 1.35E+00 1.30E+00 1.25E+00 1.20E+00 1.15E+00 1.10E+00 1.05E+00 1.00E+00 0 0.5 1 1.5 2 2.5 3 Frequency (GHz) Figure 3. Typical Isolation Frequency (GHz) 0 1 2 3 4 0 –10 –20 Typical Isolation –30 –40 –50 –60 –70 –80 –90 –100 Dynamic Characteristics ............................................................................ Maximum relay operate time 10 ms Note Certain applications may require additional time for proper settling. Refer to the NI Switches Help at ni.com/manuals for more information about including additional settling time. ............................................................................ Expected mechanical relay life 1 × 107 cycles 4 | ni.com | NI PXIe-2748 Specifications Physical Characteristics Relay ............................................................................ type Electromechanical, latching I/O connectors ............................................................................ 17 MCX jacks, gold plated PXI ............................................................................ Express power requirement 3.96 W at 3.3 V, 0.2 W at 12 V Dimensions (L × W × H) ............................................................................ 3U, one slot, PXI/cPCI module 21.6 cm × 2.0 cm × 13.0 cm (8.5 in. × 0.8 in. × 5.1 in.) Weight ............................................................................ 330 g (11.30 oz) Environment ............................................................................ Operating temperature 0 °C to 55 °C Storage temperature ............................................................................ -40 °C to 70 °C Relative humidity ............................................................................ 5% to 85%, noncondensing Pollution Degree ............................................................................ 2 Maximum altitude ............................................................................ 2,000 m Indoor use only. Shock and Vibration ............................................................................ Operational Shock 30 g peak, half-sine, 11 ms pulse (Tested in accordance with IEC 60068-2-27. Test profile developed in accordance with MIL-PRF-28800F.) Random Vibration Operating .................................................................... 5 Hz to 500 Hz, 0.3 grms Nonoperating .................................................................... 5 Hz to 500 Hz, 2.4 grms (Tested in accordance with IEC 60068-2-64. Nonoperating test profile exceeds the requirements of MIL-PRF-28800F, Class 3.) Diagrams The following figure shows the NI PXIe-2748 power-on state. NI PXIe-2748 Specifications | © National Instruments | 5 Figure 4. NI PXIe-2748 Power-On State CH0 CH1 CH2 CH3 CH4 CH5 CH6 CH7 COM CH8 CH9 CH10 CH11 CH12 CH13 CH14 CH15 The following figure shows the NI PXIe-2748 front panel connector. 6 | ni.com | NI PXIe-2748 Specifications Figure 5. NI PXIe-2748 Front Panel 3 GHz 16 x 1 50 Ω Multiplexer CH 0 CH 8 CH 1 CH 9 CH 2 CH 10 CH 3 CH 11 COM CH 4 CH 12 CH 5 CH 13 CH 6 CH 14 CH 7 CH 15 MAX 10W Accessories Visit ni.com for more information about the following accessories. NI PXIe-2748 Specifications | © National Instruments | 7 Table 1. NI Accessories for the NI PXIe-2748 Accessory Length Part Number MCX-MCX cable 0.3 m 188374-0R3 MCX-MCX cable 1.0 m 188374-01 MCX-BNC cable 0.3 m 188375-0R3 MCX-BNC cable 1.0 m 188375-01 MCX-SMB cable 0.3 m 188376-0R3 MCX-SMB cable 1.0 m 188376-01 MCX-SMA cable 0.3 m 188377-0R3 MCX-SMA cable 1.0 m 188377-01 Compliance and Certifications Safety This product is designed to meet the requirements of the following electrical equipment safety standards for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1, CSA 61010-1 Note For UL and other safety certifications, refer to the product label or the Online Product Certification section. Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement, control, and laboratory use: • EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity • EN 55011 (CISPR 11): Group 1, Class A emissions • EN 55022 (CISPR 22): Class A emissions • EN 55024 (CISPR 24): Immunity • AS/NZS CISPR 11: Group 1, Class A emissions • AS/NZS CISPR 22: Class A emissions • FCC 47 CFR Part 15B: Class A emissions • ICES-001: Class A emissions Note In the United States (per FCC 47 CFR), Class A equipment is intended for use in commercial, light-industrial, and heavy-industrial locations. In Europe, 8 | ni.com | NI PXIe-2748 Specifications Canada, Australia, and New Zealand (per CISPR 11), Class A equipment is intended for use only in heavy-industrial locations. Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection/analysis purposes. Note For EMC declarations, certifications, and additional information, refer to the Online Product Certification section. CE Compliance This product meets the essential requirements of applicable European Directives, as follows: • 2014/35/EU; Low-Voltage Directive (safety) • 2014/30/EU; Electromagnetic Compatibility Directive (EMC) Online Product Certification Refer to the product Declaration of Conformity (DoC) for additional regulatory compliance information. To obtain product certifications and the DoC for this product, visit ni.com/ certification, search by model number or product line, and click the appropriate link in the Certification column. Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers. For additional environmental information, refer to the Minimize Our Environmental Impact web page at ni.com/environment. This page contains the environmental regulations and directives with which NI complies, as well as other environmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the product life cycle, all NI products must be disposed of according to local laws and regulations. For more information about how to recycle NI products in your region, visit ni.com/environment/weee. 电子信息产品污染控制管理办法(中国 RoHS) 中国客户 National Instruments 符合中国电子信息产品中限制使用某些有害物 质指令(RoHS)。关于 National Instruments 中国 RoHS 合规性信息,请登录 ni.com/environment/rohs_china。(For information about China RoHS compliance, go to ni.com/environment/rohs_china.) NI PXIe-2748 Specifications | © National Instruments | 9 Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. © 2015 National Instruments. All rights reserved. 376209A-01 Jun15