MULTILAYER CERAMIC CAPACITOR RoHS AD Series (X7R/X5R/Y5V/Z5U): Axial Leaded INTRODUCTION FEATURES Radial Leaded Multilayer Ceramic Capacitors are made with a superior epoxy coating for moisture and mechanical protection. The small size is suitable for a wide range of applications, including: data processing, telecommunications, instrumentation and industrial controls. • Epoxy Coating • Minature Size • Auto Insertable • Reliable PART NUMBER EXAMPLE AD10 XR 104 K 500 R Packing Code Temperature Coefficient Voltage Code Tolerance Code P=5.0+/-0.5mm T1=6.0+/-0.3mm W=52+/-1 L1=L2=24 SIZE CODE & CAPACITANCE RANGE Size Code AD10 Dimensions (mm) T (max) D (max) F (±0.8) 2.6 4.0 5.0 7.52 AD15 3.1 5.1 10 Voltage Vdc Voltage Code 6.3V 050 100 160 250 500 101 251 10V 16V 25V 50V 100V 250V 6.3V 10V 16V 25V 50V 100V 250V 500V X7R ( F) X5R ( F) 0.22~2.20 0.10~1.50 0.00022~0.33 0.00022~0.10 0.001~0.033 060 100 160 250 500 101 251 501 0.30~4.70 0.68~2.20 0.47~1.00 0.033~0.47 0.015~0.15 0.001~0.033 1.50~10.00 0.33~4.70 1.00 0.22 10.00~22.00 6.80~10.00 10.00 3.30 Y5V ( F) Z5U ( F) 4.70~22.00 2.20~10.00 1.00~4.70 0.47~2.20 0.10~1.00 0.22~1.00 47.00 22.00 10.00 4.70 2.20 CAPACITANCE CODE Code Capacitance 221 102 222 103 473 104 105 106 0.00022 F 0.001 F 0.00022 F 0.01 F 0.047 F 0.1 F 1.0 F 10 F Page 1 of 4 C1BD04 2012.03.08 MULTILAYER CERAMIC CAPACITOR RoHS AD Series (X7R/X5R/Y5V/Z5U): Axial Leaded TOLERANCE CODE Code Cap. TEMPERATURE COEFFICIENT Tol. C ±0.25pF D ±0.5pF F ±1% G ±2% J ±5% K ±10% M ±20% Z ±80%, -20% Code Temp. Charact. Temperature Range Capacitance Change CG C0G/NPO -55 ~ 125℃ 0±30 ppm/℃ X5R X5R -55 ~ 85℃ ±15℃ XR X7R -55 ~ 125℃ ±15℃ YV Y5V -30 ~ 85℃ +22℃, -82% ZU Z5U +10 ~ 85℃ +22℃, -56% * See other AD Series for COG/NPO TAPING & PACKAGING DIMENSIONS Tape Spec. Symbol Dimension (mm) Pitch of component P 5.08±0.51 Culmulative Tolerance of P ±0.15 Over 6 Consecutive Units. Tape Width Wt 6.0±1.0 Lead Wire Protrusion Le 1.0 max Lead Extension into Tape Li 1.5 max Offset Between Tapes T 0.8 max Width Between Tapes W 52.4±1.5 Lead Diameter d 0.483 Reel Spec. Centered Core Diameter Reel Diameter Core Width Recess Depth Arbor Hole Deflection from Nominal Position Symbol Dimension (mm) C ±0.76 D1 34.9-92.1 Standard 82 D2 360 max Standard 340 W1 67(+1.5, -0) R 9.5 min. Standard 16 H0 13.89-38.10 Standard 17 h 1.2 max Page 2 of 4 C1BD04 2012.03.08 MULTILAYER CERAMIC CAPACITOR RoHS AD Series (X7R/X5R/Y5V/Z5U): Axial Leaded ELECTRICAL CHARACTERISTICS X7R/X5R/Y5V/Z5U Parameter Specification Capacitance With the specified tolerance Measuring Condition X7R= 0.03max 25V X7R= 0.055max.(C min Y5V= 0.075max Z5U= 0.09max 16V X7R/X5R=0.05max. Y5V= 0.10max 10V X7R/X5R=0.05max. max Y5V= 0.125max be measured at 25 ℃ ± 2℃ at the ≧ 1.0uF) Shall frequency and voltage Dissipation Factor (tanδ) X7R/X5R/Y5V @ 1Hz ± 10%, 1±0.2Vrms Z5U @ 1Hz ± 10%, 0.5±0.2Vrms 6.3V X5R= 0.075max Withstanding Voltage No defects Insulation Resistance More than 10GΩ or 500M Ω‧μF whichever is less 16Vdc product: More than 10GΩ or 100MΩ‧μ F whichever is less Applied voltage: Rated veltage X 2.5 100V~500V Rated voltage (over) X 1.5 Duration: 1 to 5 sec. The charge/discharge current is less than 50mA Apply rated voltage for 1 minute at 25℃± 2℃ and 70% R.H. max . 16Vdc product: Measurement voltage is 25Vdc STORAGE 1. The storage conditions < 40℃, < 70% R.H. 2. After opening the package, please store in desiccators. ENVIRONMENTAL AND TEST CHARACTERISTICS Parameter Specification Measuring Condition Termination not to be broken or loosened Strength of termination Solderability of leads Force:4 LB min. Keep time:10 ±1 sec. Lead wire to be soldered vertically up to the coating end point. At least 75%of lead surface is covered Solder temperature: 250 5 Dipping: 2 0.5 sec. (containing Ag2~5%) (Flux shall be used) Page 3 of 4 C1BD04 2012.03.08 MULTILAYER CERAMIC CAPACITOR RoHS AD Series (X7R/X5R/Y5V/Z5U): Axial Leaded ELECTRICAL CHARACTERISTICS X7R/X5R/Y5V/Z5U Item Temperature Compensating Measuring Condition Resistance X7R/X5R= ±7.5% C Y5V= ± 20% Z5U= ± 20% X7R= 0.03max X7R= 0.055max.(C ≧1.0uF) 25V min Y5V= 0.075max Z5U= 0.09max D.F. 16V X7R/X5R=0.05max. Y5V= 0.10max 10V X7R/X5R=0.05max. max Y5V= 0.125max 6.3V X5R= 0.075max More than 10G or 500M ‧μF, whichever is less. I.R. 16V dc product: More than 10G or 100M ‧μF, whichever is less. Item Temperature Compensating to Soldering Measuring Condition heat The lead wire is immersed in the melted solder 1.5mm to 2mm form the main body at 260 ± 5℃ for 10 ± 0.5sec Let sit at room temperature for 48 ± 4hrs. Perform the five cycles according to the four heat treatments listed in the following then measure. table. Remove and let sit at room temperaturefor 48 ± 4hrs., then measure. Initial measurement for perform a +0 Step 1 2 3 4 heat treatment at 150 - 10 ℃ for 1 hours. Min. Max. Temp. Room Room Remove and let sit for 48 ± 4hrs.At Operating Operating (℃) Temp. Temp. Temp. Temp. room temperature. Time Perform the initial measurement. X7R= 0.06max X7R= 0.11max.(C≧1.0uF) 25V min Y5V= 0.1125max Z5U= 0.135max D.F. 16V X7R/X5R=0.10max. Y5V= 0.15max 10V X7R/X5R=0.10max. max Y5V= 0.1875max 6.3V X5R= 0.15max More than 1000G or 50M ‧μF, whichever is less. I.R. 16V dc product: More than 1000G or 10M ‧μF, whichever is less. 30±3 15 30±3 15 Initial measurement for perform a heat treatment at 150 +- 100 ℃ for 1 hours. Remove and let sit for 48 ± 4hrs. At room temperature. Perform the initial measurement. Measuring Condition Moisture resistance (Steady state) X7R/X5R= ±15% C Y5V= ± 30% Z5U= ± 30% Thermal shock Measuring Condition High temperature loading Apply the rated DC voltage at 40 ± 2℃ - 0 hrs. and 90 to 95% R.H. for 500 +24 Apply the 200% of rated DC voltage for - 0 hrs. at the maximum operating 1000 +48 temperature ± 2℃. Remove and let sit at Remove and let sit at room temperature room temperaturefor 48 ± 4hrs., than measure. for 48 ± 4hrs, then measure. Initial measurement for perform a heat treatment at 150 +- 100 ℃ for 1 hours. Remove and let sit for 48 ± 4hrs.At room temperature. Perform the initial measurement. The charge/discharge current is less than 50mA. Initial measurement for Apply 200% of the rated DC voltage for 1 hour at the maximum operating temperature ± 2℃. Remove let sit at room temperature for 48 ± 4hrs. Perform the initial measurement. * 100% for 100V~500V Page 4 of 4 C1BD04 2012.03.08