RoHS INTRODUCTION FEATURES Radial Leaded Multilayer Ceramic Capacitors are made with a superior epoxy coating for moisture and mechanical protection. The small size is suitable for a wide range of applications, including: data processing, telecommunications, instrumentation, and industrial controls. • Epoxy Coating • Minature Size • Auto Insertable • Reliable W PART NUMBER EXAMPLE 7.62 mm max RD 25 ZU 104 M 251 B XX H MIN 20mm Lead Forming Size code Temperature (Omit if no Forming) T W Packing Code Voltage Code H d d=0.5±0.05 Tolerance Code F SIZE CODE & CAPACITANCE RANGE Size Code Dimensions (mm) W H T RD2 ∗ 4.0 4.0 2.5 RD3 ∗ 5.0 5.0 3.0 Voltage Vdc 6.3V 10V 16V 25V 50V 100V 250V 6.3V 10V 16V 25V 50V 100V 250V 500V Voltage Code 060 100 160 250 500 101 251 060 100 160 250 500 101 251 501 X7R (µf) X5R Y5V Z5U (µf) (µf) (µf) 1.50 ~ 10.00 4.70 ~ 22.00 0.33 ~ 4.70 2.20 ~ 10.00 0.22 ~ 2.20 0.15 ~ 2.2 1.00 ~ 4.70 0.10 ~ 1.50 0.10 ~ 1.0 0.47 ~ 2.20 0.47 ~ 2.20 0.00022 ~ 0.33 0.10 ~ 1.00 0.1 ~ 1.00 0.1 ~ 1.00 0.00022 ~ 0.10 0.001 ~ 0.033 10.00 ~ 22.00 47 ~ 100.0 6.80 ~ 10.00 22 ~ 47.0 0.30 ~ 4.70 1.5 ~ 10.00 10 ~ 22 0.68 ~ 2.20 4.7 ~ 10 0.47 ~ 1.00 2.2 ~ 4.7 0.033 ~ 0.47 0.015 ~ 0.15 0.001 ~ 0.033 * 2 = 2.5mm ± 1mm Lead Spacing, F Dimension * 5 = 5.0mm ± 1mm Lead Spacing, F Dimension CAPACITANCE CODE EXAMPLES Code 221 Capacitance in µF Capacitance in pF 102 222 0.00022µF 0.001µF 0.0022µF 220pF 1,000pF 2,200pF 103 473 104 105 106 0.01µF 0.047µF 0.1µF 1.0µF 10µF 10,000pF 47,000pF 100,000pF 1,000,000pF 10,000,000pF Page 1 of 4 RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected] C1BD02 2015.07.28 RoHS TOLERANCE CODE Code Cap. TEMPERATURE COEFFICIENT Tol. C ±0.25pF D ±0.5pF F ±1% G ±2% J ±5% K ±10% M ±20% Z ±80%, -20% Code Temp. Charact. Temperature Range Capacitance Change CG C0G/NPO -55 ~ 125℃ 0±30 ppm/℃ X5R X5R -55 ~ 85℃ ±15% XR X7R -55 ~ 125℃ ±15% YV Y5V -30 ~ 85℃ +22%, -82% ZU Z5U +10 ~ 85℃ +22%, -56% * See other RD Series for COG/NPO TAPING & PACKAGING PACKAGING CODE Code Style Quantity B BULK 1000 A AMMO 3000 R REEL 3000 Lead Forming Code Stand off forming KO Kink Out KI Kink In LEAD LENGTH EXAMPLE (Bulk Only) Code 20 Length (mm) standard 04 10 16 30 4±1 10±1 16±1.5 1 30±3 Page 2 of 4 RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected] C1BD02 2015.07.28 RoHS ELECTRICAL CHARACTERISTICS X7R/X5R/Y5V/Z5U Parameter Specification Capacitance With the specified tolerance X7R= 0.03max 25V X7R= 0.055max.(C ≧ 1.0uF) min Y5V= 0.075max Z5U= 0.09max 16V X7R/X5R=0.05max. Y5V= 0.10max 10V X7R/X5R=0.05max. max Y5V= 0.125max Dissipation Factor (tanδ) Measuring Condition Shall be measured at 25 ℃ ± 2℃ at the frequency and voltage X7R/X5R/Y5V @ 1Hz ± 10%, 1±0.2Vrms Z5U @ 1Hz ± 10%, 0.5±0.2Vrms 6.3V X5R= 0.075max Withstanding Voltage No defects Insulation Resistance More than 10GΩ or 500M Ω‧μF whichever is less 16Vdc product: More than 10GΩ or 100MΩ‧μ F whichever is less Applied voltage: Rated veltage X 2.5 100V~500V Rated voltage (over) X 1.5 Duration: 1 to 5 sec. The charge/discharge current is less than 50mA Apply rated voltage for 1 minute at 25℃± 2℃ and 70% R.H. max . 16Vdc product: Measurement voltage is 25Vdc STORAGE 1. The storage conditions < 40℃, < 70% R.H. 2. After opening the package, please store in desiccators. ENVIRONMENTAL AND TEST CHARACTERISTICS Parameter Strength of termination Solderability of leads Specification Measuring Condition Termination not to be broken or loosened Force:2 LB min. Keep time:10±1 sec. Lead wire to be soldered vertically up to the coating end point. At least 75%of lead surface is covered Solder temperature: 260 ± 5℃ Dipping: 2 ± 0.5 sec. (Containing Ag 2~5%) (Flux shall be used) Page 3 of 4 RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected] C1BD02 2015.07.28 RoHS ELECTRICAL CHARACTERISTICS X7R/X5R/Y5V/Z5U Item Temperature Compensating Measuring Condition Measuring Condition Resistance to Soldering heat X7R/X5R= ±7.5% C Y5V= ± 20% Z5U= ± 20% X7R= 0.03max 25V X7R= 0.055max.(C ≧ 1.0uF) min Y5V= 0.075max Z5U= 0.09max D.F. 16V X7R/X5R=0.05max. Y5V= 0.10max 10V X7R/X5R=0.05max. max Y5V= 0.125max 6.3V X5R= 0.075max More than 10G or 500M ‧μF, whichever is less. I.R. 16V dc product: More than 10G or 100M ‧μF, whichever is less. Item Temperature Compensating The lead wire is immersed in the melted solder 1.5mm to 2mm form the main body at 260 ± 5℃ for 10 ± 0.5sec Let sit at room temperature for 48 ± 4hrs. Perform the five cycles according to the four heat treatments listed in the following then measure. table.Remove and let sit at room temperaturefor 48 ± 4hrs., then measure. Initial measurement for perform a Step 1 2 3 4 heat treatment at 150 +- 100 ℃ for 1 hours. Min. Max. Temp. Room Room Remove and let sit for 48 ± 4hrs.At Operating Operating (°C) Temp. Temp. Temp. Temp. room temperature. Time Perform the initial measurement. X7R= 0.06max X7R= 0.11max.(C≧1.0uF) 25V min Y5V= 0.1125max Z5U= 0.135max D.F. 16V X7R/X5R=0.10max. Y5V= 0.15max 10V X7R/X5R=0.10max. max Y5V= 0.1875max 6.3V X5R= 0.15max More than 1000G or 50M ‧μF, whichever is less. I.R. 16V dc product: More than 1000G or 10M ‧μF, whichever is less. 30±3 15 30±3 15 Initial measurement for perform a heat treatment at 150 +- 100 ℃ for 1 hours. Remove and let sit for 48 ± 4hrs.At room temperature. Perform the initial measurement. Measuring Condition Moisture resistance (Steady state) X7R/X5R= ±15% C Y5V= ± 30% Z5U= ± 30% Thermal shock Measuring Condition High temperature loading Apply the rated DC voltage at 40 ± 2℃ - 0 hrs. and 90 to 95% R.H. for 500 +24 Apply the 200% of rated DC voltage for - 0 hrs.at the maximum operating 1000 +48 temperature ± 2℃.Remove and let sit at Remove and let sit at room temperature room temperaturefor 48 ± 4hrs.,than measure. for 48 ± 4hrs, then measure. Initial measurement for perform a heat treatment at 150 +- 100 ℃ for 1 hours. Remove and let sit for 48 ± 4hrs.At room temperature. Perform the initial measurement. The charge/discharge current is less than 50mA. Initial measurement for Apply 200% of the rated DC voltage for 1 hour at the maximum operating temperature ± 2℃. Remove let sit at room temperature for 48 ± 4hrs. Perform the initial measurement. * 100% for 100V~500V Page 4 of 4 RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected] C1BD02 2015.07.28