RD22, RD25 - RFE International, Inc.

RoHS
INTRODUCTION
FEATURES
Radial Leaded Multilayer Ceramic Capacitors are
made with a superior epoxy coating for moisture
and mechanical protection. The small size is
suitable for a wide range of applications, including:
data processing, telecommunications,
instrumentation, and industrial controls.
• Epoxy Coating
• Minature Size
• Auto Insertable
• Reliable
W
PART NUMBER EXAMPLE
7.62
mm
max
RD 25 ZU 104 M 251 B XX
H
MIN
20mm
Lead Forming
Size code
Temperature
(Omit if no Forming)
T
W
Packing Code
Voltage Code
H
d
d=0.5±0.05
Tolerance Code
F
SIZE CODE & CAPACITANCE RANGE
Size
Code
Dimensions (mm)
W
H
T
RD2 ∗
4.0
4.0
2.5
RD3 ∗
5.0
5.0
3.0
Voltage
Vdc
6.3V
10V
16V
25V
50V
100V
250V
6.3V
10V
16V
25V
50V
100V
250V
500V
Voltage
Code
060
100
160
250
500
101
251
060
100
160
250
500
101
251
501
X7R
(µf)
X5R
Y5V
Z5U
(µf)
(µf)
(µf)
1.50 ~ 10.00 4.70 ~ 22.00
0.33 ~ 4.70 2.20 ~ 10.00
0.22 ~ 2.20
0.15 ~ 2.2
1.00 ~ 4.70
0.10 ~ 1.50
0.10 ~ 1.0
0.47 ~ 2.20 0.47 ~ 2.20
0.00022 ~ 0.33 0.10 ~ 1.00
0.1 ~ 1.00 0.1 ~ 1.00
0.00022 ~ 0.10
0.001 ~ 0.033
10.00 ~ 22.00 47 ~ 100.0
6.80 ~ 10.00 22 ~ 47.0
0.30 ~ 4.70
1.5 ~ 10.00
10 ~ 22
0.68 ~ 2.20
4.7 ~ 10
0.47 ~ 1.00
2.2 ~ 4.7
0.033 ~ 0.47
0.015 ~ 0.15
0.001 ~ 0.033
* 2 = 2.5mm ± 1mm Lead Spacing, F Dimension
* 5 = 5.0mm ± 1mm Lead Spacing, F Dimension
CAPACITANCE CODE EXAMPLES
Code
221
Capacitance
in µF
Capacitance
in pF
102
222
0.00022µF 0.001µF 0.0022µF
220pF
1,000pF
2,200pF
103
473
104
105
106
0.01µF
0.047µF
0.1µF
1.0µF
10µF
10,000pF 47,000pF 100,000pF
1,000,000pF 10,000,000pF
Page 1 of 4
RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected]
C1BD02
2015.07.28
RoHS
TOLERANCE CODE
Code
Cap.
TEMPERATURE COEFFICIENT
Tol.
C
±0.25pF
D
±0.5pF
F
±1%
G
±2%
J
±5%
K
±10%
M
±20%
Z
±80%, -20%
Code
Temp.
Charact.
Temperature
Range
Capacitance
Change
CG
C0G/NPO
-55 ~ 125℃
0±30 ppm/℃
X5R
X5R
-55 ~ 85℃
±15%
XR
X7R
-55 ~ 125℃
±15%
YV
Y5V
-30 ~ 85℃
+22%, -82%
ZU
Z5U
+10 ~ 85℃
+22%, -56%
* See other RD Series for COG/NPO
TAPING & PACKAGING
PACKAGING CODE
Code
Style
Quantity
B
BULK
1000
A
AMMO
3000
R
REEL
3000
Lead Forming
Code
Stand off forming
KO
Kink Out
KI
Kink In
LEAD LENGTH EXAMPLE (Bulk Only)
Code
20
Length
(mm) standard
04
10
16
30
4±1
10±1
16±1.5
1
30±3
Page 2 of 4
RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected]
C1BD02
2015.07.28
RoHS
ELECTRICAL CHARACTERISTICS
X7R/X5R/Y5V/Z5U
Parameter
Specification
Capacitance
With the specified tolerance
X7R= 0.03max
25V X7R= 0.055max.(C ≧ 1.0uF)
min Y5V= 0.075max
Z5U= 0.09max
16V X7R/X5R=0.05max.
Y5V= 0.10max
10V X7R/X5R=0.05max.
max Y5V= 0.125max
Dissipation Factor
(tanδ)
Measuring Condition
Shall be measured at 25 ℃ ± 2℃ at the
frequency and voltage
X7R/X5R/Y5V
@ 1Hz ± 10%, 1±0.2Vrms
Z5U
@ 1Hz ± 10%, 0.5±0.2Vrms
6.3V X5R= 0.075max
Withstanding Voltage
No defects
Insulation Resistance
More than 10GΩ or 500M Ω‧μF
whichever is less
16Vdc product:
More than 10GΩ or 100MΩ‧μ F
whichever is less
Applied voltage:
Rated veltage X 2.5
100V~500V Rated voltage (over) X 1.5
Duration: 1 to 5 sec.
The charge/discharge current is less
than 50mA
Apply rated voltage for 1 minute
at 25℃± 2℃ and 70% R.H. max
.
16Vdc product:
Measurement voltage is 25Vdc
STORAGE
1. The storage conditions < 40℃, < 70% R.H.
2. After opening the package, please store in desiccators.
ENVIRONMENTAL AND TEST CHARACTERISTICS
Parameter
Strength of
termination
Solderability of
leads
Specification
Measuring Condition
Termination not to be broken or loosened
Force:2 LB min.
Keep time:10±1 sec.
Lead wire to be soldered vertically up to
the coating end point.
At least 75%of lead surface is covered
Solder temperature: 260 ± 5℃
Dipping: 2 ± 0.5 sec.
(Containing Ag 2~5%)
(Flux shall be used)
Page 3 of 4
RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected]
C1BD02
2015.07.28
RoHS
ELECTRICAL CHARACTERISTICS
X7R/X5R/Y5V/Z5U
Item
Temperature Compensating
Measuring Condition
Measuring Condition
Resistance to Soldering heat
X7R/X5R= ±7.5%
C Y5V= ± 20%
Z5U= ± 20%
X7R= 0.03max
25V X7R= 0.055max.(C ≧ 1.0uF)
min Y5V= 0.075max
Z5U= 0.09max
D.F. 16V X7R/X5R=0.05max.
Y5V= 0.10max
10V X7R/X5R=0.05max.
max Y5V= 0.125max
6.3V X5R= 0.075max
More than 10G or 500M ‧μF,
whichever is less.
I.R. 16V dc product:
More than 10G or 100M ‧μF,
whichever is less.
Item
Temperature Compensating
The lead wire is immersed in the melted solder 1.5mm to 2mm form the main body
at 260 ± 5℃ for 10 ± 0.5sec
Let sit at room temperature for 48 ± 4hrs. Perform the five cycles according to the
four heat treatments listed in the following
then measure.
table.Remove and let sit at room
temperaturefor 48 ± 4hrs., then measure.
Initial measurement for perform a
Step
1
2
3
4
heat treatment at 150 +- 100 ℃ for 1 hours.
Min.
Max.
Temp.
Room
Room
Remove and let sit for 48 ± 4hrs.At
Operating
Operating
(°C)
Temp.
Temp.
Temp.
Temp.
room temperature.
Time
Perform the initial measurement.
X7R= 0.06max
X7R=
0.11max.(C≧1.0uF)
25V
min Y5V= 0.1125max
Z5U= 0.135max
D.F. 16V X7R/X5R=0.10max.
Y5V= 0.15max
10V X7R/X5R=0.10max.
max Y5V= 0.1875max
6.3V X5R= 0.15max
More than 1000G or 50M ‧μF,
whichever is less.
I.R. 16V dc product:
More than 1000G or 10M ‧μF,
whichever is less.
30±3
15
30±3
15
Initial measurement for perform a heat
treatment at 150 +- 100 ℃ for 1 hours. Remove
and let sit for 48 ± 4hrs.At room
temperature.
Perform the initial measurement.
Measuring Condition
Moisture resistance
(Steady state)
X7R/X5R= ±15%
C Y5V= ± 30%
Z5U= ± 30%
Thermal shock
Measuring Condition
High temperature loading
Apply the rated DC voltage at 40 ± 2℃
- 0 hrs.
and 90 to 95% R.H. for 500 +24
Apply the 200% of rated DC voltage for
- 0 hrs.at the maximum operating
1000 +48
temperature ± 2℃.Remove and let sit at
Remove and let sit at room temperature room temperaturefor 48 ± 4hrs.,than
measure.
for 48 ± 4hrs, then measure.
Initial measurement for perform a heat
treatment at 150 +- 100 ℃ for 1 hours.
Remove and let sit for 48 ± 4hrs.At
room temperature.
Perform the initial measurement.
The charge/discharge current is less
than 50mA.
Initial measurement for Apply 200% of
the rated DC voltage for 1 hour at the
maximum operating temperature ± 2℃.
Remove let sit at room temperature for
48 ± 4hrs.
Perform the initial measurement.
* 100% for 100V~500V
Page 4 of 4
RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail [email protected]
C1BD02