Drive Application Software Application Set Application Set Title Drive Product File Name for (AS) Date / Revision Analog Speed Ref PowerFlex 700S AS_PF700S_AnalogSpdRef.dno 11/15/2002 01 Attention: This document and related file(s) are designed to supplement configuration of the listed drive product. The information provided does not replace the drive products user manual and is intended for qualified personnel only. Description: Analog speed reference with 3wire start/stop control Limitations: Options & Notes: 1, See option in the parameter table 2, Default configuration for 3 wire control through digital inputs may be changed to 2 wire control or for operation through 20-COMM-x module. Drive Input & Output Connections: Inputs Function DI 1 Start DI 2 Stop DI 3 DI 4 NA DI 5 NA DI 6 NA AI 1 Speed Reference AI 2 AI 3 NA Outputs Function DO 1 DO 2 DO 3 NA AO 1 AO 2 AO 3 NA AS_PF700S_AnalogSpdRef.doc Form Revision – A Page 1 of 2 Description 0-10v Description Drive Application Software Application Set Parameter Configurations Changes from Default Parameter Settings Par Name Value b0 = 0 153 Control Options b6 = 1 b8 = 1 16 Speed Ref Sel Speed Ref 1 10 Speed Ref 1 11 Spd Ref1 Divide **** Optional - 32 33 838 839 840 802 804 805 808 810 811 Accel Time Decel Time DigIn1 Sel DigIn2 Sel DigIn3 Sel Anlg In1 Scale AI 1 Filt Gain Anlg In1 BW Anlg In2 Scale AI 2 Filt Gain Anlg In2 BW 10 10 Start Normal Stop Not Used 10 0.25 50 10 0.25 50 30 Rev Speed Lim 0 31 Fwd Speed Lim Dflt= 2175 AS_PF700S_AnalogSpdRef.doc Form Revision – A Page 2 of 2 Link 800 100 Description Bipolar SRef Stop in Torq – Stop function if in torque control mode 3WireControl Base Speed reference 0 to 100% of Motor base speed Speed Reference scale Use to scale the sections machine speed to the desired value (or Motor Rpm). At 100% speed the motor will run base speed. The speed reference value is scaled so 1pu = base speed motor Rpm. Set scaling of speed reference in p11 to 100 and then use p38 [Speed Ref Scale] to scale the final speed reference. A setting of 1 in p38 will = mtr base speed. A setting of 1.1 in p38 will = 110% mtr base speed. Etc. Example(1750*1.1=1925rpm) Set per application requirements Set per application requirements Start input for 3wire control Stop input for 3wire control Scale AI1 for 0 to 10v = 0 to 100 (% Speed) Light filtering Light filtering Scale AI1 for 0 to 10v = 0 to 100% Light filtering Light filtering Forward operation only Adjust as need to allow required speed – should be within 10% of max speed required