User Data Sheet

Drive Application Software
Application Set
Application Set Title
Drive Product
File Name for (AS)
Date / Revision
Analog Speed Ref
PowerFlex 700S
AS_PF700S_AnalogSpdRef.dno
11/15/2002
01
Attention:
This document and related file(s) are designed to
supplement configuration of the listed drive product. The
information provided does not replace the drive products
user manual and is intended for qualified personnel only.
Description:
Analog speed reference with 3wire start/stop control
Limitations:
Options &
Notes:
1, See option in the parameter table
2, Default configuration for 3 wire control through digital inputs may be changed to 2 wire
control or for operation through 20-COMM-x module.
Drive Input & Output Connections:
Inputs
Function
DI 1
Start
DI 2
Stop
DI 3
DI 4
NA
DI 5
NA
DI 6
NA
AI 1
Speed Reference
AI 2
AI 3
NA
Outputs
Function
DO 1
DO 2
DO 3
NA
AO 1
AO 2
AO 3
NA
AS_PF700S_AnalogSpdRef.doc
Form Revision – A
Page 1 of 2
Description
0-10v
Description
Drive Application Software
Application Set
Parameter Configurations
Changes from Default Parameter Settings
Par
Name
Value
b0 = 0
153 Control Options
b6 = 1
b8 = 1
16
Speed Ref Sel
Speed Ref 1
10
Speed Ref 1
11
Spd Ref1 Divide
****
Optional -
32
33
838
839
840
802
804
805
808
810
811
Accel Time
Decel Time
DigIn1 Sel
DigIn2 Sel
DigIn3 Sel
Anlg In1 Scale
AI 1 Filt Gain
Anlg In1 BW
Anlg In2 Scale
AI 2 Filt Gain
Anlg In2 BW
10
10
Start
Normal Stop
Not Used
10
0.25
50
10
0.25
50
30
Rev Speed Lim
0
31
Fwd Speed Lim
Dflt= 2175
AS_PF700S_AnalogSpdRef.doc
Form Revision – A
Page 2 of 2
Link
800
100
Description
Bipolar SRef
Stop in Torq – Stop function if in torque control mode
3WireControl
Base Speed reference
0 to 100% of Motor base speed
Speed Reference scale
Use to scale the sections machine speed to the
desired value (or Motor Rpm). At 100% speed the
motor will run base speed. The speed reference
value is scaled so 1pu = base speed motor Rpm.
Set scaling of speed reference in p11 to 100 and then
use p38 [Speed Ref Scale] to scale the final speed
reference. A setting of 1 in p38 will = mtr base speed.
A setting of 1.1 in p38 will = 110% mtr base speed.
Etc. Example(1750*1.1=1925rpm)
Set per application requirements
Set per application requirements
Start input for 3wire control
Stop input for 3wire control
Scale AI1 for 0 to 10v = 0 to 100 (% Speed)
Light filtering
Light filtering
Scale AI1 for 0 to 10v = 0 to 100%
Light filtering
Light filtering
Forward operation only
Adjust as need to allow required speed – should be
within 10% of max speed required