User Data Sheet

Drive Application Software
Application Set
Application Set Title
Drive Product
File Name for (AS)
Date / Firmware Rev.
Analog Speed Ref
PowerFlex 700S AC Drive Phase II
AS_PF700SII_AnalogSpdRef_A.dno
02/03/06
3.01
Attention:
This document and related file(s) are designed to
supplement configuration of the listed drive product. The
information provided does not replace the drive products
user manual and is intended for qualified personnel only.
Description:
Analog speed reference with 3Wire Start/Stop Control.
Limitations:
Options &
Notes:
1. See option in the parameter table.
2. Default configuration for 3Wire Control through digital inputs may be changed to 2Wire
Control or for operation through 20-COMM-x module.
Drive Input & Output Connections:
Inputs
Function
DI 1
DI 2
DI 3
DI 4
Start
DI 5
Stop
DI 6
HW Enable
AI 1
Speed Reference
AI 2
AI 3
Outputs
Function
DO 1
DO 2
DO 3
AO 1
AO 2
AO 3
AS_PF700SII_AnalogSpdRef_A.doc
Form Revision – A
Page 1 of 2
Description
0-10v
Description
Drive Application Software
Application Set
Parameter Configurations
Changes from Default Parameter Settings
Par
Name
Value
b0 = 0
153
Control Options
b6 = 1
b8 = 1
27
Speed Ref A Sel
Speed Ref 1
10
Speed Ref 1
11
Spd Ref1 Divide
****
Optional -
32
33
828
829
802
804
805
808
810
811
30
Accel Time
Decel Time
DigIn4 Sel
DigIn5 Sel
Anlg In1 Scale
AI 1 Filt Gain
Anlg In1 Filt BW
Anlg In2 Scale
AI 2 Filt Gain
Anlg In2 Filt BW
Min Spd Ref Lim
10
10
Start
Normal Stop
10
0.25
50
10
0.25
50
0
31
Max Spd Ref Lim
Dflt= 2170
AS_PF700SII_AnalogSpdRef_A.doc
Form Revision – A
Page 2 of 2
Link
800
100
Description
Bipolar SRef
Stop in Torq – Stop function if in torque control mode
3Wire Control
Base Speed reference
0 to 100% of Motor base speed
Speed Reference scale
Use to scale the sections machine speed to the
desired value (or Motor Rpm). At 100% speed the
motor will run base speed. The speed reference
value is scaled so 1pu = base speed motor Rpm.
Set scaling of speed reference in p11 to 100 and then
use p38 [Speed Ref Scale] to scale the final speed
reference. A setting of 1 in p38 will = mtr base speed.
A setting of 1.1 in p38 will = 110% mtr base speed.
Etc. Example(1750*1.1=1925rpm)
Set per application requirements
Set per application requirements
Start input for 3wire control
Stop input for 3wire control
Scale AI1 for 0 to 10v = 0 to 100 (% Speed)
Light filtering
Light filtering
Scale AI1 for 0 to 10v = 0 to 100%
Light filtering
Light filtering
Forward operation only
Adjust as need to allow required speed – should be
within 10% of max speed required