Drive Application Software Application Set Application Set Title Drive Product File Name for (AS) Date / Firmware Rev. Analog Speed Ref with Reverse PowerFlex 700S AC Drive Phase II AS_PF700SII_AnalogSpdRefwRev_A.dno 02/03/06 3.01 Attention: This document and related file(s) are designed to supplement configuration of the listed drive product. The information provided does not replace the drive products user manual and is intended for qualified personnel only. Description: Analog speed reference with 3Wire Start/Stop Control and reverse. Limitations: Options & Notes: 1. See option in the parameter table. 2. Default configuration for 3Wire Control through digital inputs may be changed to 2Wire Control or for operation through 20-COMM-x module. Drive Input & Output Connections: Inputs Function DI 1 DI 2 DI 3 Reverse DI 4 Start DI 5 Stop DI 6 HW Enable AI 1 Speed Reference AI 2 AI 3 Outputs Function DO 1 DO 2 DO 3 AO 1 AO 2 AO 3 AS_PF700SII_AnalogSpdRefwRev_A.doc Form Revision – A Page 1 of 2 Description 0-10v Description Drive Application Software Application Set Parameter Configurations Changes from Default Parameter Settings Par Name Value b0 = 0 153 Control Options b6 = 1 b8 = 1 27 Speed Ref A Sel Speed Ref 1 10 Speed Ref 1 11 32 33 827 828 829 802 804 805 808 810 811 Spd Ref1 Divide Accel Time Decel Time DigIn3 Sel DigIn4 Sel DigIn5 Sel Anlg In1 Scale AI 1 Filt Gain Anlg In1 BW Anlg In2 Scale AI 2 Filt Gain Anlg In2 BW 100 10 10 Reverse Start Normal Stop 10 0.25 50 10 0.25 50 30 Min Spd Ref Lim Dflt= -2170 31 Max Spd Ref Lim Dflt= 2170 Link 800 AS_PF700SII_AnalogSpdRefwRev_A.doc Form Revision – A Page 2 of 2 Description Bipolar SRef Stop in Torq – Stop function if in torque control mode 3Wire Control Base Speed reference 0 to 100% of Motor base speed Scales the Speed Reference to a per unit value Set per application requirements Set per application requirements Reverse Reference Input Start input for 3Wire Control Stop input for 3Wire Control Scale AI1 for 0 to 10v = 0 to 100 (% Speed) Light filtering Light filtering Scale AI1 for 0 to 10v = 0 to 100% Light filtering Light filtering Adjust as need to allow required speed – should be within 10% of max speed required Adjust as need to allow required speed – should be within 10% of max speed required