C-Band / Ku-Band C-Band 7700 and Ku-Band 7900 Series RBUCs Features at a Glance • • • • • • Ideally suited to rapid deploy or offshore applications Includes entire feature set of existing BUC families Uniquely designed cooling system AC and DC powered versions Suitable 48 VDC power supplies available as options Available in single thread and 1+1 redundant configurations Rugged Design MTBF exceeds 100,000 hours. IP66 rating against water and dust storms. Dual cooling fans for redundancy. Sealed to 34 kPA (5 psi) Most Comprehensive M&C Ethernet (HTTP web server, Telnet and SNMP). RS232, RS422/485 serial interface, FSK, dry contact closure, RF power meter. Large selection of management protocols also included. Global Applications Meets Electromagnetic Compatibility Directive 2004/108/EC to satisfy worldwide requirements and is CE-marked. Worldwide Support Product photos are representative; actual product sold may vary slightly from product photos on this datasheet. 7700 and 7900 Series 40 W to 200 W BUCs for maritime, VSAT and SOTM satellite uplink applications OPTIONS •1:1 redundant switching •One-stop shop for complete satellite system (refer to BUC accessories data sheet) •LAN Interface •FSK to USB interface •Reference Source •Handheld Controller •Remote Controller •LNBs •Waveguide Components Backed by over 35 years of satellite communications experience, and CPI’s worldwide 24-hour customer support network that includes more than 20 regional factory service centers. 811 Hansen Way, PO Box 51625 Palo Alto, CA 94303 USA tel: +1 (650) 846-3803 fax: +1 (650) 424-1744 e-mail:[email protected] website:www.cpii.com/satcom C-Band / Ku-Band Specifications 40 W Ku-band, 100 and 200 W C-band RBUCs Ku-Band Model Number RF Power Rating Platform C-Band 7940 7710H 40 watts 100 watts RF Output Connector VSWR (max.) AC powered N-type N-type WR-75, PBR 120 flange WR-137, CPR-137G flange 1.7:1 output, 1.5:1 input 1.7:1 output, 1.5:1 input RF Output Frequency Range (GHz) 14.0 - 14.5 13.75 - 14.50 5.850 - 6.425 RF Input Frequency Range (MHz) 950 - 1450 950 - 1700 Transmit Attenuator Steps 13050 12800 5.850 - 6.425 950 - 1525 950 - 1750 950 - 1525 950 - 1750 7300 & 7375 7300, 7375, 7600 & 7675 7300 & 7375 7300, 7375, 7600 & 7675 0 dB to 15 dB in 1 dB steps 50 Ω 50 Ω -31 dBm nominal -31 dBm nominal IF Input Power @1 dB GCP, CW and max. gain Gain @0 dB Attenuation 5.850 - 6.725 0 dB to 15 dB in 1 dB steps IF Input Impedence RF Output Power @1 dB GCP, CW (min) 200 watts DC powered RF Input Connector LO Frequency (MHz) 7720H 45.5 dBm 45.0 dBm 77 dB nom. 50.0 dBm 49.5 dBm 5.850 - 6.425 53.0 dBm 84 dB nom. 87 dB nom. ±0.75 dB max. over any 40 MHz band; ±1.50 dB max. over full band ±0.75 dB max. over any 40 MHz band; ±1.50 dB max. over full band Gain Stability Over any 50°C Temperature Range ±1.50 dB max. when frequency set ±1.50 dB max. when frequency set Gain Stability Over Full Temperature Range (freq. set) ±2.0 dB max. ±2.0 dB max. Gain Stability Over Full Temperature Range (freq. not set) ±3.0 dB max. Gain Flatness Intermodulation -25 dBc with respect to each of two carriers @6 dB OBO ±4.0 dB max. 52.5 dBm ±3.0 dB max. ±3.0 dB max. -25 dBc with respect to each of two carriers @6 dB OBO Spurious/Harmonic Output -50 dBc max. @ 3 dB OBO -50 dBc max. @ 3 dB OBO AM/PM Conversion 2.0°/dB max @ 2 dB OPBO 2.0°/dB max @ 2 dB OPBO Reference Frequency (external) 10 MHz 10 MHz Ref. Frequency Input (external) Multiplexed on N-type transmit IF input Multiplexed on N-type transmit IF input Reference Frequency Level Reference Frequency Connector Frequency Conversion -10 to +5 dBm -10 to +5 dBm Via N-type transmit IF input Via N-type transmit IF input Non-inverting Inverting Maximum Phase Noise (SSB) of Reference Frequency -135 dBc/Hz at 100 Hz -145 dBc/Hz at 1 kHz -155 dBc/Hz at 10 kHz -155 dBc/Hz at 100 kHz -135 dBc/Hz at 100 Hz -145 dBc/Hz at 1 kHz -155 dBc/Hz at 10 kHz -155 dBc/Hz at 100 kHz Phase noise (SSB) of BUC with reference frequency defined above -63 dBc/Hz at 100 Hz -73 dBc/Hz at 1 kHz -83 dBc/Hz at 10 kHz -93 dBc/Hz at 100 kHz -63 dBc/Hz at 100 Hz -73 dBc/Hz at 1 kHz -83 dBc/Hz at 10 kHz -93 dBc/Hz at 100 kHz Output Power Meter Range 15 dB 15 dB Output Power Meter Absolute Accuracy ±1.0 dB max. when compensation frequency set; ±2.0 dB max. when compensation frequency not set ±1.0 dB max. when compensation frequency set; ±2.0 dB max. when compensation frequency not set Output Power Meter Relative Accuracy ±0.5 dB max. when compensation frequency set; ±1.0 dB max. when compensation frequency not set ±0.5 dB max. when compensation frequency set; ±1.0 dB max. when compensation frequency not set Power Meter Modes CW and burst (>100 uS) with adjustable threshold CW and burst (>100 uS) with adjustable threshold Power Supply Voltage +36 V to +72 V DC via external DC connector Page 2 of 4 95 to 275 VAC via Amphenol T 3110 000 176 to 275 VAC via Amphenol T 3110 000 C-Band / Ku-Band Specifications, continued 40 W Ku-band, 100 and 200 W C-band RBUCs Ku-Band Model Number 7940 Power Supply Minimum Turn On Voltage +41 V Monitor and Control Ethernet Interface Digital data format RS232 Digital data format RS485 Digital connector FSK data format FSK data transmitter frequency FSK data transmitter deviation FSK data transmitter sense FSK output level FSK start tone time FSK data receiver nominal frequency FSK data receiver locking range FSK data receiver input sensitivity Temperature Range Relative Humidity Weatherproofing Power Supply Consumption Volume (L x W x H) Weight Page 3 of 4 C-Band 7710H 7720H N/A TCP/IP Protocol, 10/100 BaseT via 8 pin 62IN-16J-10-8S-622 connector to RJ45 Embedded HTTP Web server, Telnet, and SNMP 9600 bps, 8 bits, no parity, 1 stop bit, ASCII protocol User selectable protocols MIL-C-26482 12-14S socket User selectable protocols 650 kHz ±1% ±60 kHz ±1% +60 kHz=mark; –60 kHz=space –8 dB nominal 10 ms min TCP/IP Protocol, 10/100 BaseT via 8 pin 62IN-16J-10-8S-622 connector to RJ45 Embedded HTTP Web server, Telnet, and SNMP 9600 bps, 8 bits, no parity, 1 stop bit, ASCII protocol User selectable protocols MIL-C-26482 12-14S socket User selectable protocols 650 kHz ±1% ±60 kHz ±1% +60 kHz=mark; –60 kHz=space –8 dB nominal 10 ms min 650 kHz ±30 kHz 650 kHz ±30 kHz –15 dBm min –15 dBm min –40 to +55°C operating, –40 to +70°C non-operating –40 to +55°C operating, –40 to +70°C non-operating 100% condensing 100% condensing Sealed to 34 kPa Sealed to 34 kPa 430 W typ, 570 W max. 560 W typ, 700 W max. 1000 W typ, 1200 W max. 323 x 182 x 150 mm (12.7” x 7.2” x 5.9”) 402 x 198 x 170 mm (15.8” x 7.8” x 6.7”) 490 x 220 x 220 mm (19.3” x 8.7” x 8.7”) 8 kg (17.6 lbs) 13 kg (28.7 lbs) 23 kg (50.7 lbs) C-Band / Ku-Band Configuration Guide 40 W Ku-band, 100 and 200 W C-band RBUCs Configure your 7000 Series RBUCs Configuring your RBUC is easy. Much of the configuration is already predetermined. Use the the C-band configuration line below if configuring a C-band BUC, or use the Ku-band configuration line below if configuring model 7940 Ku-band BUC. All that is left to determine is which model of C-band unit is required (if applicable), which frequency range, and for the Ku-band only, the type of input power desired. Box 1: C-Band only - Output Power Level/Model Number - Enter “7710H” for 100 W model - Enter “7720H” for 200 W model Box 3: Output frequency range (within the C-band or Ku-band) - Enter “S” for 5.850 to 6.425 GHz, or 14.00 to 14.50 GHz - Enter “E” for 5.850 to 6.725 GHz, or 13.75 to 14.50 GHz Box 4: Ku-Band only - Input power - Enter “48” for 36-60 V DC input power - Enter “AC” for AC power C-Band Ku-Band _ 1 / 2 7940 1 W _ W 2 3 _ AC / EX 4 _ / 3 4 5 / EX _ 5 NI 6 Examples: 7710H-W/E-AC/EX indicates a 100 W C-band RBUC operating in the 5.850 to 6.725 GHz frequency range. 7940-W/S-48/EX indicates a 40 W Ku-band RBUC operating in the 14.0 - 14.5 GHz frequency range, with 48 V DC input. Notes: Box 2 indicates a waveguide RF output connection. Box 5 indicates that power is fed via an external connector. Box 6 indicates that this product is a non-inverting BUC. Quality Management System - ISO 9001:2008 For more detailed information, please refer to the corresponding CPI technical description if one has been published, or contact CPI. Specifications may change without notice as a result of additional data or product refinement. Please contact CPI before using this information for system design. MKT 378, ISSUE 3 dated JUN 2015, page 4 of 4