C-Band 7700 and Ku-Band 7900 Series RBUCs

C-Band / Ku-Band
C-Band 7700 and Ku-Band 7900 Series RBUCs
Features at a Glance
•
•
•
•
•
•
Ideally suited to rapid deploy or offshore applications
Includes entire feature set of existing BUC families
Uniquely designed cooling system
AC and DC powered versions
Suitable 48 VDC power supplies available as options
Available in single thread and 1+1
redundant configurations
Rugged
Design MTBF exceeds 100,000 hours. IP66 rating against
water and dust storms. Dual cooling fans for redundancy.
Sealed to 34 kPA (5 psi)
Most Comprehensive M&C
Ethernet (HTTP web server, Telnet and SNMP). RS232,
RS422/485 serial interface, FSK, dry contact closure,
RF power meter. Large selection of management protocols
also included.
Global Applications
Meets Electromagnetic Compatibility Directive 2004/108/EC
to satisfy worldwide requirements and is CE-marked.
Worldwide Support
Product photos are representative; actual product sold may vary slightly from
product photos on this datasheet.
7700 and 7900 Series
40 W to 200 W BUCs
for maritime, VSAT and SOTM
satellite uplink applications
OPTIONS
•1:1 redundant switching
•One-stop shop for complete satellite
system (refer to BUC accessories
data sheet)
•LAN Interface
•FSK to USB interface
•Reference Source
•Handheld Controller
•Remote Controller
•LNBs
•Waveguide Components
Backed by over 35 years of satellite communications
experience, and CPI’s worldwide 24-hour customer
support network that includes more than 20 regional
factory service centers.
811 Hansen Way, PO Box 51625
Palo Alto, CA 94303 USA
tel:
+1 (650) 846-3803
fax:
+1 (650) 424-1744
e-mail:[email protected]
website:www.cpii.com/satcom
C-Band / Ku-Band
Specifications 40 W Ku-band, 100 and 200 W C-band RBUCs
Ku-Band
Model Number
RF Power Rating
Platform
C-Band
7940
7710H
40 watts
100 watts
RF Output Connector
VSWR (max.)
AC powered
N-type
N-type
WR-75, PBR 120 flange
WR-137, CPR-137G flange
1.7:1 output, 1.5:1 input
1.7:1 output, 1.5:1 input
RF Output Frequency Range (GHz)
14.0 - 14.5
13.75 - 14.50
5.850 - 6.425
RF Input Frequency Range (MHz)
950 - 1450
950 - 1700
Transmit Attenuator Steps
13050
12800
5.850 - 6.425
950 - 1525
950 - 1750
950 - 1525
950 - 1750
7300 & 7375
7300, 7375,
7600 & 7675
7300 & 7375
7300, 7375,
7600 & 7675
0 dB to 15 dB in 1 dB steps
50 Ω
50 Ω
-31 dBm nominal
-31 dBm nominal
IF Input Power @1 dB GCP, CW
and max. gain
Gain @0 dB Attenuation
5.850 - 6.725
0 dB to 15 dB in 1 dB steps
IF Input Impedence
RF Output Power @1 dB GCP, CW
(min)
200 watts
DC powered
RF Input Connector
LO Frequency (MHz)
7720H
45.5 dBm
45.0 dBm
77 dB nom.
50.0 dBm
49.5 dBm
5.850 - 6.425
53.0 dBm
84 dB nom.
87 dB nom.
±0.75 dB max. over any 40 MHz band;
±1.50 dB max. over full band
±0.75 dB max. over any 40 MHz band;
±1.50 dB max. over full band
Gain Stability Over
any 50°C Temperature Range
±1.50 dB max. when frequency set
±1.50 dB max. when frequency set
Gain Stability Over Full
Temperature Range (freq. set)
±2.0 dB max.
±2.0 dB max.
Gain Stability Over Full
Temperature Range (freq. not set)
±3.0 dB max.
Gain Flatness
Intermodulation
-25 dBc with respect to each of two carriers @6 dB OBO
±4.0 dB max.
52.5 dBm
±3.0 dB max.
±3.0 dB max.
-25 dBc with respect to each of two carriers @6 dB OBO
Spurious/Harmonic Output
-50 dBc max. @ 3 dB OBO
-50 dBc max. @ 3 dB OBO
AM/PM Conversion
2.0°/dB max @ 2 dB OPBO
2.0°/dB max @ 2 dB OPBO
Reference Frequency (external)
10 MHz
10 MHz
Ref. Frequency Input (external)
Multiplexed on N-type transmit IF input
Multiplexed on N-type transmit IF input
Reference Frequency Level
Reference Frequency Connector
Frequency Conversion
-10 to +5 dBm
-10 to +5 dBm
Via N-type transmit IF input
Via N-type transmit IF input
Non-inverting
Inverting
Maximum Phase Noise (SSB) of
Reference Frequency
-135 dBc/Hz at 100 Hz
-145 dBc/Hz at 1 kHz
-155 dBc/Hz at 10 kHz
-155 dBc/Hz at 100 kHz
-135 dBc/Hz at 100 Hz
-145 dBc/Hz at 1 kHz
-155 dBc/Hz at 10 kHz
-155 dBc/Hz at 100 kHz
Phase noise (SSB) of BUC with
reference frequency
defined above
-63 dBc/Hz at 100 Hz
-73 dBc/Hz at 1 kHz
-83 dBc/Hz at 10 kHz
-93 dBc/Hz at 100 kHz
-63 dBc/Hz at 100 Hz
-73 dBc/Hz at 1 kHz
-83 dBc/Hz at 10 kHz
-93 dBc/Hz at 100 kHz
Output Power Meter Range
15 dB
15 dB
Output Power Meter
Absolute Accuracy
±1.0 dB max. when compensation frequency set;
±2.0 dB max. when compensation frequency not set
±1.0 dB max. when compensation frequency set;
±2.0 dB max. when compensation frequency not set
Output Power Meter
Relative Accuracy
±0.5 dB max. when compensation frequency set;
±1.0 dB max. when compensation frequency not set
±0.5 dB max. when compensation frequency set;
±1.0 dB max. when compensation frequency not set
Power Meter Modes
CW and burst (>100 uS) with adjustable threshold
CW and burst (>100 uS) with adjustable threshold
Power Supply Voltage
+36 V to +72 V DC via external DC connector
Page 2 of 4
95 to 275 VAC
via Amphenol T 3110 000
176 to 275 VAC
via Amphenol T 3110 000
C-Band / Ku-Band
Specifications, continued 40 W Ku-band, 100 and 200 W C-band RBUCs
Ku-Band
Model Number
7940
Power Supply Minimum
Turn On Voltage
+41 V
Monitor and Control
Ethernet Interface
Digital data format RS232
Digital data format RS485
Digital connector
FSK data format
FSK data transmitter frequency
FSK data transmitter deviation
FSK data transmitter sense
FSK output level
FSK start tone time
FSK data receiver
nominal frequency
FSK data receiver locking range
FSK data receiver
input sensitivity
Temperature Range
Relative Humidity
Weatherproofing
Power Supply Consumption
Volume (L x W x H)
Weight
Page 3 of 4
C-Band
7710H
7720H
N/A
TCP/IP Protocol, 10/100 BaseT via 8 pin
62IN-16J-10-8S-622 connector to RJ45
Embedded HTTP Web server, Telnet, and SNMP
9600 bps, 8 bits, no parity, 1 stop bit, ASCII protocol
User selectable protocols
MIL-C-26482 12-14S socket
User selectable protocols
650 kHz ±1%
±60 kHz ±1%
+60 kHz=mark; –60 kHz=space
–8 dB nominal
10 ms min
TCP/IP Protocol, 10/100 BaseT via 8 pin
62IN-16J-10-8S-622 connector to RJ45
Embedded HTTP Web server, Telnet, and SNMP
9600 bps, 8 bits, no parity, 1 stop bit, ASCII protocol
User selectable protocols
MIL-C-26482 12-14S socket
User selectable protocols
650 kHz ±1%
±60 kHz ±1%
+60 kHz=mark; –60 kHz=space
–8 dB nominal
10 ms min
650 kHz
±30 kHz
650 kHz
±30 kHz
–15 dBm min
–15 dBm min
–40 to +55°C operating, –40 to +70°C non-operating
–40 to +55°C operating, –40 to +70°C non-operating
100% condensing
100% condensing
Sealed to 34 kPa
Sealed to 34 kPa
430 W typ, 570 W max.
560 W typ, 700 W max.
1000 W typ, 1200 W max.
323 x 182 x 150 mm
(12.7” x 7.2” x 5.9”)
402 x 198 x 170 mm
(15.8” x 7.8” x 6.7”)
490 x 220 x 220 mm
(19.3” x 8.7” x 8.7”)
8 kg (17.6 lbs)
13 kg (28.7 lbs)
23 kg (50.7 lbs)
C-Band / Ku-Band
Configuration Guide
40 W Ku-band, 100 and 200 W C-band RBUCs
Configure your 7000 Series RBUCs
Configuring your RBUC is easy. Much of the configuration is already predetermined.
Use the the C-band configuration line below if configuring a C-band BUC, or use the
Ku-band configuration line below if configuring model 7940 Ku-band BUC. All that
is left to determine is which model of C-band unit is required (if applicable), which
frequency range, and for the Ku-band only, the type of input power desired.
Box 1: C-Band only - Output Power Level/Model Number
- Enter “7710H” for 100 W model
- Enter “7720H” for 200 W model
Box 3: Output frequency range (within the C-band or Ku-band)
- Enter “S” for 5.850 to 6.425 GHz, or 14.00 to 14.50 GHz
- Enter “E” for 5.850 to 6.725 GHz, or 13.75 to 14.50 GHz
Box 4: Ku-Band only - Input power
- Enter “48” for 36-60 V DC input power
- Enter “AC” for AC power
C-Band
Ku-Band
_
1
/
2
7940
1
W
_
W
2
3
_ AC / EX
4
_
/
3
4
5
/ EX _
5
NI
6
Examples: 7710H-W/E-AC/EX indicates a 100 W C-band RBUC operating in
the 5.850 to 6.725 GHz frequency range. 7940-W/S-48/EX indicates a 40 W
Ku-band RBUC operating in the 14.0 - 14.5 GHz frequency range, with
48 V DC input.
Notes: Box 2 indicates a waveguide RF output connection. Box 5 indicates that
power is fed via an external connector. Box 6 indicates that this product is
a non-inverting BUC.
Quality Management
System - ISO 9001:2008
For more detailed information, please refer to the corresponding CPI technical description if one has been
published, or contact CPI. Specifications may change without notice as a result of additional data or product
refinement. Please contact CPI before using this information for system design.
MKT 378, ISSUE 3 dated JUN 2015, page 4 of 4