PNK-10013 - Premier Magnetics

TABLE 1: ELECTRICAL SPECIFICATIONS AT 25 OC
FIGURE 1: SCHEMATIC DIAGRAM
1
PARAMETER
PRIMARY INDUCTANCE (1-2).
66 KHZ @ 0.40Vrms.
SPEC LIMITS
MIN.
TYP.
MAX.
UNITS
2264
uH
2272
2280
PRIMARY 2/2
3
12
LEAKAGE INDUCTANCE (1-2).
10 KHZ @ .1V,
-------
--------
52
uH
PRIMARY 1/2
SECONDARY
2
HIPOT: 60Hz for 1 sec.
3000
PRIMARY and BIAS to SECONDARY.
--------
--------
Vrms
4
10
BIAS
5
FIGURE 2: PHYSICAL DIMENSIONS INCHES (mm).
12
11
10
P
M
PIN #1
WHITE DOT
1
2
9
8
7
PNK-10013
YYWW
CORE
TAPE
3
4
5
6
1.165
(29.6)
MAX
1.140
(28.96)
MAX
Flux
Band.
Connect
to pin #4.
1.102
(28.0)
.300
(7.62)
Typ.
0.024
(0.6)
Dia.
0.149
(3.8)
1
2
0.295
(7.5)
3
4
5
6
NOTES:
1) Design to comply with the requirements of UL/CSA/
IEC60950-1.
2) Design to comply with the requirements of UL/CSA/IEC
Class B insulation system.
3) All materials per Premier Magnetics UL file #E177139.
4) All units comply with the requirements of the EU RoHS
Directive.
5) Connect the flux band to terminal pin #4 with #24 AWG
TIW lead wire.
1.004
(25.5)
12
11
10
9
8
7
REV.
DESCRIPTION OF CHANGES
BY
08/09/13
Original release.
KC
RoHS
UNLESS OTHERW ISE SPECIFIED
DIMENSIONS ARE IN INCHES.
DIMENSIONAL TOLERANCES ARE:
DECIMALS
ANGLES
.XX + .02
+5O
.XXX + .015
DRAW ING NOT TO SCALE.
TRANSFOMER CONTROL DRAWING
PREMIER P/N: PNK-10013
REVISION: 08/09/13
ENGR: PETER PHAM
REF:
QA: Kevin Clark
SHEET: 1 OF 1