PB Ordering information Unit type PBA10F PB 1 A 2 10 F 3 5 Recommended Noise Filter NAC-06-472 R -O 4 High voltage pulse noise type : NAP series Low leakage current type : NAM series *The Noise Filter is recommended *to connect with several devices. -O 6 1Series name 2Single output 3Output wattage 4Universal input 5Output voltage 6Optional C :with Coating G :Low leakage current E :Low leakage current and EMI class A T :Vertical terminal block J :Connector type N :with Cover (UL508 is pending for approval) N1 :with DIN rail V :Output voltage setting potentiometer externally Cover is optional MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT PBA10F-5 10 5V 2A PBA10F-12 10.8 12V 0.9A PBA10F-24 12 24V 0.5A SPECIFICATIONS MODEL VOLTAGE[V] PBA10F-5 PBA10F-12 PBA10F-24 AC85 - 264 1f or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage *3) ACIN 100V 0.30typ (Io=100%) CURRENT[A] ACIN 200V 0.20typ (Io=100%) FREQUENCY[Hz] 50/60 (47 - 440) or DC INPUT ACIN 100V 74typ 76typ 77typ EFFICIENCY[%] ACIN 200V 74typ 76typ 77typ ACIN 100V 15typ (Io=100%) INRUSH CURRENT[A] ACIN 200V 30typ (Io=100%) LEAKAGE CURRENT[mA] 0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN) VOLTAGE[V] 5 12 24 CURRENT[A] 2 0.9 0.5 LINE REGULATION[mV] 20max 48max 96max LOAD REGULATION[mV] 40max 100max 150max 0 to +50C *1 80max 120max 120max RIPPLE[mVp-p] -10 - 0C *1 140max 160max 160max 0 to +50C *1 120max 150max 150max RIPPLE NOISE[mVp-p] OUTPUT -10 - 0C *1 160max 180max 180max 0 to +50C 50max 120max 240max TEMPERATURE REGULATION[mV] -10 to +50C 60max 150max 290max *2 20max 48max 96max DRIFT[mV] START-UP TIME[ms] 200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage. HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 - 5.50 10.0 - 13.2 19.2 - 27.0 OUTPUT VOLTAGE SETTING[V] 5.00 - 5.15 12.00 - 12.48 24.00 - 24.96 OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically PROTECTION OVERVOLTAGE PROTECTION[V] 5.75 - 7.00 15.0 - 18.0 30.0 - 37.0 CIRCUIT AND OPERATING INDICATION LED (Green) OTHERS REMOTE ON/OFF None INPUT-OUTPUT AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) ISOLATION INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) OUTPUT-FG AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature) OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max ENVIRONMENT VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN SAFETY AND CONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B NOISE Low Voltage Directive, EMC Directive REGULATIONS CE MARKING HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Not built-in to active filter *4) (without terminal block (without ) CASE SIZE/WEIGHT D) / 150g maxmodel X78X68mm XHX *) (W Parallel operation with other is not cover possible. *1 Measured by 20MHz oscilloscope or Ripple-Noise 31 meter(equivalent to KEISOKU-GIKEN OTHERS * Derating is required when operated with cover. :RM101). COOLING METHOD Convection *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3 Derating is required. *4 When two or more units are used,they may not comply with the harmonic attenuator. Please Distribution: contact us for details. A-4 * A sound may occur from power supply at peak loading. RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 [email protected] www.rsg-electronic.de ■ ■ Änderungen vorbehalten / subject to change without notice ■ ■ ■ PBA10F PB Block diagram FUSE AC250V 2.5A NOISE FILTER AC IN 85 - 264V INRUSH CURRENT LIMIT RECTIFIER AND FILTER FG TRANSFORMER CONTROL INVERTER RECTIFIER AND FILTER DC OUT CURRENT SENSING Photocoupler CONTROL Photocoupler OVER VOLTAGE PROTECTION External view ¶ External size of option T,J,N,N1 and V is different from standard model and refer to 7 Option of instruction manual for details. 18 Voltage adjust 2.5 LED 16.5±2 12.2±1.5 68 Cover name plate M3 2-M3 Mounting hole 78 Cover (option) -V FG 11.5 9.5 AC(L) 34.5 7.5 70.5 +V AC(N) 15.1±1.5 49.5±0.5 Terminal cover 4 Point A:C102 22.6±1.5 Name plate 18 31 PBA10F 34.5 2-M3 Mounting hole ¶ Tolerance : ±1 ¶ Mass : 150g or less (without cover) ¶ PCB Material/thickness : CEM3 / 1.6mm ¶ Chassis material : Electric galvanizing steel board ¶ Dimensions in mm ¶ Mounting torque : 0.6N • m(6.3kgf • cm)max ¶ Screw tightening torque : M3 0.8N • m(8.5kgf • cm)max ¶ Please connect safety ground to the unit in 2-M3 holes. 36 ±0.5 11 Distribution: RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 [email protected] www.rsg-electronic.de ■ ■ Änderungen vorbehalten / subject to change without notice ■ ■ ■ A-5