100 WATT MEDICAL & ITE POWER SUPPLIES DESCRIPTION PM100 SERIES The PM100 series of compact, open PCB constructed, AC-DC (LVD) switching power supplies are capable of delivering 100 watts of RoHS continuous output power at convection cooling. They are suited for medical, information technology and industrial applications, but not for life-supporting medical equipment. Approval to both EN60601-1 and EN60950-1 safety standards improves design-in time and reduces end equipment compliance costs. FEATURES z Medical and ITE approvals z Compact size 2” × 4” × 1.26” z High power density 10 W/cubic inch z 100 W output with convection cooling up to +50℃ z Low earth leakage current z EN55011 /55022 class B emissions UL 60601-1, CSA C22.2 No. 601.1 z RoHS compliant File No. E178020 SAFETY STANDARD APPROVALS INPUT SPECIFICATIONS Input voltage: TÜV EN 60601-1 90-132 /180-264 VAC (Universal mains supply operation) Input frequency: 47-63 Hz Input current: 1.9 A (rms) for 100-120 VAC UL 60950-1, CSA C22.2 No. 60950-1 1.1 A (rms) for 200-240 VAC Earth leakage current: TÜV EN 60950-1 150 μA max. @ 264 VAC, 63 Hz GENERAL SPECIFICATIONS OUTPUT SPECIFICATIONS Output voltage/current: See rating chart. Total output power: 100 watts maximum Ripple and noise: 150 mV peak to peak on 5.0 V model, 1% peak to peak on other models Overvoltage protection: 100 KHz (typical) Efficiency: 88-90% @ 230 VAC full load Hold-up time: 12 ms minimum at 110 VAC Line regulation: ±0.2% maximum at full load Inrush current: 40 A @ 115 VAC or 80 A @ 230 VAC, at 25℃ Withstand voltage: 4000 VAC from input to output, cold start Provided on output; set at 110-140% of its nominal output voltage Overcurrent protection: Switching frequency: 1500 VAC from input to ground, All outputs protected to short circuit 500 VAC from output to ground conditions Temperature coefficient: All outputs ±0.04% /℃ maximum Transient response: Maximum excursion of 4% or better on all MTBF: 270,000 hours at full load at 25℃ ambient temperature, calculated per MIL-HDBK-217F EMC Performance models, recovering to 1% of final value EN55011 /EN55022: FCC: Class B conducted, class B radiated Class B conducted, class B radiated VCCI: Class B conducted, class B radiated EN61000-3-2: Harmonic distortion, class A EN61000-3-3: Line flicker ENVIRONMENTAL SPECIFICATIONS EN61000-4-2: ESD, ±8 KV air and ±6 KV contact Operating temperature: -10℃ to +70℃ EN61000-4-3: Radiated immunity, 3 V/m Storage temperature: -40℃ to +85℃ EN61000-4-4: Fast transient/burst, ±2 KV Relative humidity: 5% to 95% non-condensing EN61000-4-5: Surge, ±1 KV diff., ±2 KV com. Derating: Derate from 100% at +50℃ linearly to EN61000-4-6: Conducted immunity, 3 Vrms 50% at +70℃ EN61000-4-8: Magnetic field immunity, 3 A/m Convection EN61000-4-11: Voltage dip immunity, 30% reduction for 500 ms (criteria A @ 230 VAC, criteria B @ 100 VAC), 60% reduction for 100 ms (criteria B), >95% reduction for 10 ms (Criteria A) within 500 us after a 25% step load change Cooling: 9 UNIVERSAL INPUT PM100 MEDICAL & ITE SERIES OUTPUT VOLTAGE/CURRENT RATING CHART Output (1) Model PM100-10A PM100-12A PM100-13A PM100-13-1A PM100-14A PM100-15A PM100-17A PM100-18A NOTES: 1. 2. V1 5V 12 V 15 V 18 V 24 V 28 V 36 V 48 V Min. Current 0A 0A 0A 0A 0A 0A 0A 0A Max. Current 20.00 A 8.34 A 6.70 A 5.56 A 4.20 A 3.58 A 2.78 A 2.10 A Tol. ±2 % ±2 % ±2 % ±2 % ±2 % ±2 % ±2 % ±2 % Ripple & (2) Noise 150 mV 120 mV 150 mV 180 mV 240 mV 280 mV 360 mV 480 mV Max. Power 100 W 100 W 100 W 100 W 100 W 100 W 100 W 100 W Average Active Efficiency (typical) @ 115/230 Vac 85/88% 86/89% 86/89% 86/89% 87/90% 87/90% 87/89% 87/89% Safety approvals are for PCB form only. To order models with metallic L-bracket or box, change suffix “A” to “B” for L-bracket form, to “C” for enclosed form (see Outline Drawing of Cased Internal Switchers), e.g. PM100-14C. Ripple and noise is maximum peak-to-peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage and output load ranges, and with a 10 μF tantalum capacitor in parallel with a 0.1 μF ceramic capacitor across the output. MECHANICAL SPECIFICATIONS OUTPUT POWER DERATING CURVE NOTES: 1. Dimensions shown in inches [mm] 2. Tolerance 0.02 [0.5] maximum 3. Connector P1: Molex header 09-65-2038 or equivalent, mating with Molex housing 09-50-1031 or equivalent. 4. Connector P2: Molex header 09-65-2068 or equivalent, mating with Molex housing 09-50-1061 or equivalent. 5. To ensure compliance with level B emissions, connect the three “* “ marked mounting holes with metallic standoffs to chassis. 6. Weight: 190 grams (0.44 lbs.) approx. PIN CHART PIN 1 2 3 4 5 6 V1 Return V1 Return V1 Return +V1 +V1 +V1 MODEL PM100-10A PM100-13-1A PM100-17A PM100-12A PM100-14A PM100-18A PM100-13A PM100-15A 10