30-60 WATT MEDICAL & ITE POWER SUPPLIES DESCRIPTION PMP60 SERIES (LVD) The PMP60 series of AC/DC switching power supplies are for 30-60 watts of continuous output power. They are enclosed in a 94V-1 rated polyphenylene-oxide case with an IEC320/C14 inlet to mate with interchangeable cord for world-wide use. All models meet EN55011, EN55022 and FCC class B emission limits, and are designed for medical and ITE applications, not for life supporting equipment. RoHS FEATURES z z z z z z z z z z 12 standard desktop models Single, dual or triple outputs Optional output connectors Optional on/off switch 100% burn-in W i d e i n p u t r a n g e 8 5 - 2 6 4 VA C Input surge current protection Overvoltage protection Overcurrent protection Single output models compliant with CEC and E n e r g y St a r E f f i c i e n c y l e v e l I V r e q u i r e m e n t s * No load power consumption less than 0.5 W * Average active efficiency ≧85% z Compliant with RoHS requirement SAFETY STANDARD APPROVALS UL 60601-1, CSA C22.2 No. 601.1 File No. E178020 TÜV EN 60601-1 UL 60950-1, CSA C22.2 No. 60950-1 (except PMP60-14 by UL) TÜV EN 60950-1 GENERAL SPECIFICATIONS INPUT SPECIFICATIONS Input voltage: 85-264 VAC Input frequency: 47-63 Hz Input current: 1.22 A (rms) for 100 VAC 200 μA max. @ 264 VAC, 63 Hz (Touch current) Overvoltage protection: Overcurrent protection: Temperature coefficient: Transient response: 85% minimum on single output models, Hold-up time: 10 ms minimum at 110 VAC Line regulation: ±0.5% maximum at full load Inrush current: 50 A @ 115 VAC or 100 A @ 230 VAC, at Withstand voltage: OUTPUT SPECIFICATIONS Output voltage /current: Maximum output power: Ripple and noise: 40 KHz-130 KHz Efficiency: 68-74% minimum on the others 0.68 A (rms) for 240 VAC Earth leakage current: Switching frequency: See rating chart. See rating chart. 66 mVp-p maximum on 3.3 V output, 100 mVp-p maximum on 5 V output and 1% maximum on other voltage outputs (12 V, 15 V …, 48 V etc.) Provided on output #1 only, set at 112-140% of its nominal output voltage All outputs protected to short circuit conditions All outputs ±0.04% /℃ maximum Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 us after a 25% step load change MTBF: 25℃ cold start 4000 VAC from input to output, 1500 VAC from input to ground, 500 VAC from output to ground 150,000 hours minimum at full load at 25℃ ambient, calculated per MIL-HDBK-217F EMC Performance (IEC60601-1-2) EN55011 / EN55022: Class B conducted, class B radiated FCC: Class B conducted, class B radiated VCCI: Class B conducted, class B radiated EN61000-3-2: Harmonic distortion, class A and D EN61000-3-3: Line flicker EN61000-4-2: ESD, ±8 KV air and ±6 KV contact EN61000-4-3: Radiated immunity, 3 V/m for 80-2500 MHz EN61000-4-4: Fast transient/burst, ±2 KV EN61000-4-5: Surge, ±1 KV diff., ±2 KV com EN61000-4-6: Conducted immunity, 3 Vrms EN61000-4-8: Magnetic field immunity, 3 A/m EN61000-4-11: Voltage dip immunity, 30% reduction for 500 ENVIRONMENTAL SPECIFICATIONS ms, 60% reduction for 100 ms and >95% Operating temperature: Storage temperature: Relative humidity: Derating: reduction for 10 ms 0℃ to +60℃ -40℃ to +85℃ 5% to 95% non-condensing Derate from 100% at +40℃ linearly to 50% at +60℃ 47 UNIVERSAL INPUT PMP60 MEDICAL & ITE SERIES OUTPUT VOLTAGE/CURRENT RATING CHART Model PMP60-12 PMP60-13 PMP60-13-1 PMP60-14 PMP60-16 PMP60-17 PMP60-18 PMP60-23 PMP60-30 PMP60-31 PMP60-32 PMP60-36 V1 11-13 13-17 17-21 21-27 27-33 33-39 46-50 +5.0 +3.3 +5.0 +5.0 +5.0 V V V V V V V V V V V V Output Min. current 0A 0A 0A 0A 0A 0A 0A 1A 1A 1A 1A 1A #1 Max. current 5.46 A 4.62 A 3.53 A 2.86 A 2.23 A 1.82 A 1.31 A 5.0 A 6.0 A 5.0 A 5.0 A 5.0 A Tol. ±5% ±5% ±5% ±5% ±3% ±3% ±3% ±5% ±5% ±5% ±5% ±5% V2 +12 V +5 V +12 V +15 V +24 V Output #2 Min. Max. current current (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) 0.5 A 3.0 A 0.5 A 3.0 A 0.5 A 3.0 A 0.4 A 2.3 A 0.3 A 1.5 A Tol. V3 ±5% ±5% ±5% ±5% ±5% +12 V -12 V -15 V +12 V Output #3 Min. Max. current current (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) 0.1 A 0.7 A 0.1 A 0.7 A 0.1 A 0.7 A 0.1 A 0.7 A Tol. ±10% ±10% ±10% ±10% Max. Output Power 60 W 60 W 60 W 60 W 60 W 60 W 60 W 40 W 30 W 40 W 40 W 40 W NOTES: 1. The output voltages of a multiple output model may go outside of the stated tolerance when an output load current is out of stated limits. All models may be operated at no-load without damage. 2. Ripple and noise is maximum peak-to-peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage and output load ranges, and with a 10 μF tantalum capacitor in parallel with a 0.1 μF ceramic capacitor across the output. MECHANICAL SPECIFICATIONS OUTPUT POWER DERATING CURVE NOTES: 1. Dimensions shown in inches [mm] 2. Tolerance 0.02 [0.5] maximum 3. Weight: 600 grams (1.33 lbs.) approx. 4. Output connector is 5 pin DIN plug, mating with Switchcraft P/N 57GB5F receptacle or equivalent. 5. Refer to Section titled “OPTIONAL OUPUT CONNECTORS“ for optional output connectors. Add the suffix assigned for a selected connector to a wanted model number, e.g. PMP60-12-B2, for ordering. 6. To order a model with on / off switch, add suffix “ S “ to the model number, e.g. PMP60-12-B2-S PIN CHART PIN MODEL PMP60-12 PMP60-14 PMP60-13 PMP60-16 PMP60-13-1 PMP60-17 PMP60-18 PMP60-23 PMP60-30 PMP60-31 PMP60-32 1 2 3 4 5 V1 Return V1 Return +V1 V1 Return +V1 Common Return Common Return V1 N.C. V2 Common Return Common Return V1 V3 V2 PMP60-36 48