120-135 WATT MEDICAL & ITE POWER SUPPLIES DESCRIPTION PMP135 SERIES The PMP135 series of AC/DC switching power supplies are for 120-135 watts of continuous output power. They are enclosed in a 94V-1 rated polyphenylene-oxide case with an IEC320/C14 or IEC320/C18 inlet to mate with interchangeable cord for world-wide use. All models meet EN55011, EN55022 and FCC class B emission limits, and are designed for medical and ITE applications, not for life-supporting equipment. FEATURES z z z z z z z z z Low safety ground leakage current Class I models are to be certified to medical and ITE safety standards, Class II models to m e d i c a l s t a n d a r d s o n l y. W i d e i n p u t r a n g e 9 0 t o 2 6 4 VA C Optional output connectors 100% burn-in Overvoltage protection Overcurrent protection C o m p l i a n t w i t h C E C a n d E n e r g y St a r E f f i c i e n c y level V requirements * No load power consumption less than 0.5 W * Average active efficiency greater than 87% Compliant with RoHS requirements SAFETY STANDARD APPROVALS PENDING GENERAL SPECIFICATIONS Switching frequency: 90-160 KHz INPUT SPECIFICATIONS Power factor: 0.98 Typical at 115 VAC Input voltage: 90-264 VAC Efficiency: 87% min. at full load Input frequency: 47-63 Hz Hold-up time: 15 ms minimum at 110 VAC Input current: 1.60 A (rms) for 115 VAC Line regulation: ±0.5% maximum at full load 0.80 A (rms) for 230 VAC Inrush current: 80 A @ 115 VAC or 160 A @ 230 VAC, at Withstand voltage: 4000 VAC from input to output, Earth leakage current: 200 μA max. @ 264 VAC, 63 Hz Touch current: 100 μA max. @ 264 VAC, 63 Hz 25℃ cold start 1500 VAC from input to ground, 500 VAC from output to ground MTBF: 150,000 hours at full load at 25℃ambient , calculated per MIL-HDBK-217F OUTPUT SPECIFICATIONS Output voltage /current: See rating chart. EMC Performance (IEC60601-1-2) Maximum output power: Ripple and noise: Overvoltage protection: See rating chart. EN55011 /EN55022: 1% peak to peak maximum at the full load FCC: Class B conducted, class B radiated Provided and set at 115-140% of its nominal output voltage Protected to short circuit conditions VCCI: Class B conducted, class B radiated ±0.04% /℃ maximum Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 us after a 25% step load change Overcurrent protection: Temperature coefficient: Transient response: ENVIRONMENTAL SPECIFICATIONS Operating temperature: Storage temperature: Relative humidity: Derating: 0℃ to +60℃ -40℃ to +85℃ 5% to 95% non-condensing Derate from 100% at +40℃ linearly to 50% at +60℃ Class B conducted, class B radiated EN61000-3-2: Harmonic distortion, class A and D EN61000-3-3: Line flicker EN61000-4-2: ESD, ±8 KV air and ±6 KV contact EN61000-4-3: Radiated immunity, 3 V/m EN61000-4-4: Fast transient/burst, ±2 KV EN61000-4-5: Surge, ±1 KV diff., ±2 KV com. EN61000-4-6: Conducted immunity, 3 Vrms EN61000-4-8: Magnetic field immunity, 3 A/m EN61000-4-11: Voltage dip immunity, 30% reduction for 500 ms, 60% reduction for 100 ms and >95% reduction for 10 ms 53 UNIVERSAL INPUT PMP135 MEDICAL & ITE SERIES OUTPUT VOLTAGE/CURRENT RATING CHART Model Class I PMP135-12 PMP135-12-1 PMP135-13 PMP135-13-1 PMP135-13-3 PMP135-14 PMP135-15 PMP135-16 PMP135-17 PMP135-18 (1) Average Active Efficiency (typical) Max. Power @ 115 / 230 Vac 120 W 88 / 89 % 120 W 87 / 89 % 130 W 87 / 89 % 135 W 88 / 89 % 135 W 87 / 89 % 135 W 88 / 90 % 135 W 88 / 90 % 135 W 89 / 90 % 135 W 89 / 91 % 135 W 90 / 91 % Output Class I I PMP135F-12 PMP135F-12-1 PMP135F-13 PMP135F-13-1 PMP135F-13-3 PMP135F-14 PMP135F-15 PMP135F-16 PMP135F-17 PMP135F-18 V1 12 V 13 V 14 V - 16 V 18 V - 19 V 20 V - 21 V 24 V - 25 V 28 V - 29 V 30 V - 32 V 36 V - 38 V 46 V - 50 V Min. Current 0A 0A 0A 0A 0A 0A 0A 0A 0A 0A Max. Current 10.00 A 9.23 A 9.29 A 7.50 A 6.75 A 5.63 A 4.83 A 4.50 A 3.75 A 2.94 A Tol. ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% ±5% Ripple & (2) Noise 120 mV 130 mV 150 mV 180 mV 200 mV 240 mV 280 mV 300 mV 360 mV 480 mV NOTES: 1. Class I models are equipped with IEC320/C14 inlet, and class II models with IEC320/C18 inlet. 2. Ripple and noise is maximum peak-to-peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage and output load ranges, and with a 10 μF tantalum capacitor in parallel with a 0.1 μF ceramic capacitor across the output. MECHANICAL SPECIFICATIONS OUTPUT POWER DERATING CURVE PMP135-13-1,13-3,14,15,16,17,18 140 135 130 PMP135-13 120 PMP135-12,12-1 100 80 67.5W 65.0W 60.0W 60 40 NOTES: 1. Dimensions shown in inches [mm] 2. Tolerance 0.02 [0.5] maximum 3. Weight: 681 grams (1.505 lbs.) approx. 4. Refer to Section titled “OPTIONAL OUTPUT CONNECTORS”. Add the suffix assigned for a selected connector to a wanted model number, e.g. PMP135-14-B1, for ordering. 5. The length of output cable for PMP135-12, PMP135-12-1, PMP135-13, PMP135F-12, PMP135F-12-1, and PMP135F-13 is 37.4 (950) 20 0 10 20 30 40 50 60 PIN CHART PIN MODEL PMP135-12 PMP135F-12 PMP135-12-1 PMP135F-12-1 PMP135-13 PMP135F-13 PMP135-13-1 PMP135F-13-1 PMP135-13-3 PMP135-14 PMP135-15 PMP135-16 PMP135-17 PMP135-18 PMP135F-13-3 PMP135F-14 PMP135F-15 PMP135F-16 PMP135F-17 PMP135F-18 1 2 3 4 V1 Return +V1 V1 Return +V1 54