CF0505XT-1WR2 - RSG Electronic Components GmbH

FEATURES
● Miniature SMD package
● 3500VDC isolation
● Operating temperature range:
-50℃~+125℃
● Short circuit protection(automatic recovery)
● Internal SMD construction
● Industry standard pinout
● Components meet AEC-Q100 standards
● The production process meet TS16949
system requirements
CF0505XT-1WR2
1W, FIXED INPUT, ISOLATED &
UNREGULATED SINGLE OUTPUT
Patent Protected
APPLICATIONS
RoHS
The CF0505XT-1WR2 is designed for application where
isolated output is required from a distributed power system.It can
be used in automobile motor control and drive system.Such as
motor vehicle communication system controller, engine control
system, the ignition system, the motor voltage monitoring, the
electronic accelerator pedal, automobile tire pressure detection
system, doors and tail lights controller, air conditioning control
and battery management system (BMS), etc.
PART NUMBER SYSTEM
CF0505XT-1WR2
Rated Power
Package
Output Voltage
Input Voltage
Product Series
SELECTION GUIDE
Model
Input
Voltage(VDC)
Nominal
(Range)
Output
Voltage
(VDC)
Max.
Min.
5
(4.5-5.5)
5
200
20
CF0505XT-1WR2
Output Current
(mA)
Reflected
Max.
Ripple
Capacitive
Current
Load(µF)
@Max. Load @No Load
(mA,Typ.)
Input Current (mA,Typ.)
267
20
Efficiency
(%, Typ.)
220
15
75
INPUT SPECIFICATIONS
Item
Test Conditions
Min.
Typ.
Max.
Unit
Input Surge Voltage
(1 Sec. Max.)
5VDC Input
-0.7
--
9
VDC
Input Filter
Capacitor
OUTPUT SPECIFICATIONS
Item
Test Conditions
Min.
Typ.
Output Voltage Accuracy
Line Regulation
Max.
Unit
See tolerance envelope curve
For Vin change of ±1%
--
--
±1.2
%
Load Regulation
10% to 100% load
--
12
--
%
Temperature coefficient
100% load
--
--
±0.03
%/°C
Ripple & Noise*
20MHz Bandwidth
--
60
--
mVp-p
Short Circuit Protection
Continuous, automatic recovery
Note:* Ripple and noise tested with “parallel cable” method. See detailed operation instructions at DC-DC Application Notes.
COMMON SPECIFICATIONS
Item
Test Conditions
Min.
Typ.
Max.
Unit
Isolation Voltage
Input-Output, tested for 1 minute and leakage current less than 1 mA
3500
--
--
VDC
Isolation Resistance
Input-Output, test at 500VDC
1000
--
--
MΩ
Isolation Capacitance
Input-Output, 100KHz/0.1V
--
20
--
pF
Switching Frequency
Full load, nominal input
--
100
300
KHz
MTBF
MIL-HDBK-217F@25℃
3500
--
--
K hours
Case Material
Weight
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Epoxy Resin (UL94-V0)
-CF0505XT-1WR2
1.5
--
g
2013.09.30-A/0 Page 1 of 4
ENVIRONMENTAL SPECIFICATIONS
Item
Test Conditions
Min.
Storage Humidity
Non condensing
Operating Temperature
Power derating (≥105℃, see Figure 2)
Storage Temperature
Typ.
Max.
Unit
%
--
--
95
-50
--
125
-55
--
135
Temperature rise
Ta=25°C,100% Load
--
25
--
Lead Temperature
1.5mm from case for 10 seconds
--
--
300
Cooling
°C
Free air convection
EMC SPECIFICATIONS
EMI
CE
CISPR25/EN55025
ESD
ESD
ISO10605
CLASS 1(External Circuit Refer to Figure1)
Contact ±6KV
perf. Criteria B
EMC RECOMMENDED CIRCUIT
EMI Typical Recommended Circuit(CLASS 1):
Recommended typical circuit parameters :
LDM
+INPUT
+Vin
+Vo
Vin(V)
C1
EUT
-INPUT
GND
LOAD
EMI
C1
5
10µF
LDM
12µH
0V
(Figure1)
EMC TEST WAVEFORM (CLASS B APPLY CIRCUIT)
CF0505XT-1WR2 CE(Positive line)
CF0505XT-1WR2 CE(Negetive line)
PRODUCT TYPICAL CURVE
Tolerance E nv el ope Curve
Output Voltage
Accuracy (%)
+5%
Ra ted
Outp ut
Voltage
Typ ic
a l Lo a
d L in e
+2.5%
-2.5 %
-7.5 %
50
70
100
Outp ut Curren t Percent(%)
(Nominal Input Voltage)
Output Power Percent(%)
Te m p era t u re D e rat in g G ra p h
+10%
120
100
80
60
Safe Operating Area
40
20
0
-50 -40
0
40
80 105 125
Environment Temp.(℃ )
(Figure 2)
The copyright and authority for the interpretation of the products are reserved by MORNSUN
CF0505XT-1WR2
2013.09.30-A/0 Page 2 of 4
Efficiency VS Output Load curve
(Vin=Vin-nominal)
CF0505XT-1WR2
100
90
80
70
60
50
40
30
20
10
0
10
20
30 40 50 60 70 80
Total Output Current (%)
90 100
Recommended reflow soldering profile refer to IPC/JEDEC J-STD-020D standard, our products recommended reflow soldering profile as follow:
25 0
24 5
P e a k. Te m p 2 4 5 ℃( Ma x .)
21 7
Temperature (℃)
20 0
60 Sec Max
(> 2 1 7 ℃)
15 0
10 0
50
0
Time (sec .)
Note: The curve only applies to the hot air reflow soldering
DIMENSIONS, RECOMMENDED FOOTPRINT & PACKAGING
The copyright and authority for the interpretation of the products are reserved by MORNSUN
CF0505XT-1WR2
2013.09.30-A/0 Page 3 of 4
TEST CONFIGURATIONS
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with an inductor Lin and Capacitor Cin to simulate the source impedance .
Oscilloscope
Lin
Cin
Lin(4.7µH)
Current
Probe
DC DC
Load
Cin(220µF, ESR < 1.0Ω at 100 KHz)
DESIGN CONSIDERATIONS
1) Requirement for output load
To ensure this module can operate efficiently and reliably, the minimum output load could not be less than 10% of the full load. If the actual
output power is very small, please connect a resistor to the output in parallel to increase the load.
2) Overload Protection
Under normal operating conditions, the output circuit of these products have not overload protection. The simplest method is to add a breaker
circuit in the circuit.
3) Recommended circuit
If you want to further decrease the input/output ripple, an capacitor filtering network may be connected to the input and output ends of the
DC/DC converter, refer to Figure 3.
It should also be noted that the capacitance of the capacitor must be proper. If the capacitance is too large, a startup problem might arise.For
ensuring every channel of output can provide a safe and reliable operation , the recommended capacitance of the capacitor refer to Table 1.
+Vo
Vin
DC DC
Cin
Cout
GND
0V
(Figure 3)
EXTERNAL CAPACITOR TABLE (Table 1)
Vin
Cin
Vo
Cout
(VDC)
(µF)
(VDC)
(µF)
5
4.7
5
10
It’s not recommended to connect any external capacitor in the application field with less than 0.5 watt output.
4) Output Voltage Regulation and Over-voltage Protection Circuit
The simplest device for output voltage regulation, over-voltage and over-current protection is a linear regulator with overheat protection which is
connected to the input or output in series (Figure 4)and an capacitor filtering network.the recommended capacitance of the capacitor refer to Table 1,
linear regulator based on the actual voltage and current to make a reasonable selection.
Vin
GND
REG
REG
+Vo
DC DC
0V
(Figure 4)
5) It is not recommended to increase the output power capability by connecting two or more converters in parallel. The product is not
hot-swappable
Note:
1. Operation under minimum load will not damage the converter; However, they may not meet all specifications.
2. Max. Capacitive Load is tested at nominal input voltage and full load.
3. Unless otherwise noted, All specifications are measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load.
4. In this datasheet, all test methods are based on our corporate standards.
5. All characteristics are for listed models, and non-standard models may perform differently.Please contact our technical support for more detail.
6. Please contact our technical support for any specific requirement.
7. Specifications of this product are subject to changes without prior notice.
MORNSUN Science & Technology Co.,Ltd.
Address: No. 5, Kehui St. 1, Kehui development center, Science Ave., Guangzhou Science City, Luogang district, Guangzhou,P.R.China.
Tel: 86-20-38601850
Fax:86-20-38601272
E-mail: [email protected]
Http://www.mornsun-power.com
The copyright and authority for the interpretation of the products are reserved by MORNSUN
CF0505XT-1WR2
2013.09.30-A/0 Page 4 of 4