TECH. CORP. SPECIFICATIONS CUSTOMER : CTW1281 SAMPLE CODE : SE128128WRF011H01Q MASS PRODUCTION CODE : PE128128WRF011H01Q SAMPLE VERSION : 02 SPECIFICATIONS EDITION : 005 DRAWING NO. (Ver.) : LMD- PE128128WRF011H01Q (Ver:002) PACKAGING NO. (Ver.) : PKG-PE128128WRF011H01Q (Ver:001) Customer Approved Date: Approved Checked Designer 廖志豪 Rex Liao 張慶源 Yuan Chang 李健弘 Lambert Lee POWERTIP 2010.01.29 □ Preliminary specification for design input ■ Specification for sample approval TW RD APR POWERTIP TECH. CORP. Headquarters: th No.8, 6 Road, Taichung Industrial Park, TEL: 886-4-2355-8168 E-mail: [email protected] FAX: 886-4-2355-8166 Http://www.powertip.com.tw Taichung, Taiwan 台中市 407 工業區六路 8 號 NO.PT-A-005-8 History of Version Date (mm / dd / yyyy) Ver. Edi. Description Page Design by 03/12/2009 01 001 New Drawing - Lambert 05/18/2009 01 002 Modify B/L & FPC length 4,8 Appendix Lambert 06/11/2009 01 003 First sample - Lambert Lee 004 Second sample Modify Driver Condition Modify LCM driving voltage 4 5 Lambert Lee 005 Changed back to Edi 003 Modify Driver Condition Modify LCM driving voltage 4 5 Lambert Lee 09/01/2009 12/24/2009 02 02 Total : 26 Page PE128128WRF011H01Q Page2 SAMPLE Ver.02 SPEC Edi.005 Contents 1. SPECIFICATIONS 1.1 1.2 1.3 1.4 1.5 1.6 Features Mechanical Specifications Absolute Maximum Ratings DC Electrical Characteristics Optical Characteristics Backlight & LED Characteristics 2. MODULE STRUCTURE 2.1 Counter Drawing 2.2 Interface Pin Description 2.3 Timing Characteristics 3. QUALITY ASSURANCE SYSTEM 3.1 3.2 Quality Assurance Flow Chart Inspection Specification 4. RELIABILITY TEST 4.1 Reliability Test Condition 5. PRECAUTION RELATING PRODUCT HANDLING 5.1 Safety 5.2 Handling 5.3 Storage 5.4 Terms of Warranty Appendix : 1. LCM drawing 2. LCM Packaging Note: For detailed information please refer to IC data sheet: Sitronix ST7571 PE128128WRF011H01Q Page3 SAMPLE Ver.02 SPEC Edi.005 1. SPECIFICATIONS 1.1 1.2 Features Item Standard Value Display Type 128 * 128 Dots LCD Type FSTN, Positive, White, Transflective Driver Condition LCD Module : 1/128 Duty , 1/12 Bias Viewing Direction 6 O’clock Backlight Type White LED B/L Interface 3 / 4-line Serial interface Driver IC ST7571 (4 Gray Scale) ROHS THIS PRODUCT CONFORMS THE ROHS OF PTC Detail information please refer web side : http://www.powertip.com.tw/news/LatestNews.asp Mechanical Specifications Item Standard Value Unit Outline Dimension 36.6 (L) * 42.7 (w) * 2.8 (H) mm Viewing Area 33.5 (L) * 33.5 (w) mm Active Area 28.785 (L) * 28.785 (w) mm Note : For detailed information please refer to LCM drawing PE128128WRF011H01Q Page4 SAMPLE Ver.02 SPEC Edi.005 1.3 Absolute Maximum Ratings Module 1.4 Item Symbol Condition Min. Max. Unit System Power Supply Voltage VDD - -0.3 +3.6 V Operating Temperature TOP - -20 70 °C Storage Temperature TST - -30 80 °C Storage Humidity HD Ta < 40 °C 20 90 %RH DC Electrical Characteristics VSS = 0V, Ta = 25°C Module Item Symbol Condition Min. Typ. Max. Unit Logic Supply Voltage VDD - 2.4 2.8 3.3 V “H” Input Voltage VIH - 0.7*VDD - VDD V “L” Input Voltage VIL - VSS - 0.3*VDD V “H” Output Voltage VOH - 0.7*VDD - VDD V “L” Output Voltage VOL - VSS - 0.3*VDD V VDD= 2.8V;VOP= 11.7V; Pattern= Full display - 0.5 - mA VDD= 2.8V;VOP= 11.7V; Pattern= Horizontal line*1 - 0.7 1.1 mA -20°C - 13.9 - 25°C 11.5 11.7 11.9 70°C - 11.0 - Supply current LCM driving voltage IDD VOP *1 V NOTE: *1 The Maximum current display *2 The VOP test point is V0~XV0. PE128128WRF011H01Q Page5 SAMPLE Ver.02 SPEC Edi.005 1.5 Optical Characteristics LCD Panel: 1/128 Duty,1/12 Bias,VOP = 11.7,Ta =25℃ FSTN LCD panel Item Response time Viewing angle Rise Fall Top Bottom Left Right Symbol Condition Min. Typ. Max. Tr Tf θY+ θYθXθX+ Ta = 25°C θX, θY = 0° - 120 265 35 35 40 40 180 398 - CR ≥ 2 unit ms Deg. Note2 Note1 Contrast ratio CR Ta = 25°C θX , θY = 0° 2 4 - Note3 Average Brightness Pattern=white display (With B/L ) IV IF= 30 mA 105 145 - cd/m2 Note4 Uniformity (With B/L) △B IF= 30 mA 70 - - % Note4 Note4: 1:△B=B(min) / B(max)*100% 2:Measurement Condition for Optical Characteristics: a:Environment: 25℃±5℃ / 60±20%R.H,no wind,dark room below 10 Lux at typical lamp current and typical operating frequency. b:Measurement Distance: 500 ± 50 ㎜ ,(θ= 0°) c:Equipment: TOPCON BM-7 fast,(field 1°),after 10 minutes operation. d:The uncertainty of the C.I.E coordinate measurement ±0.01,Average Brightness ± 4% 1 2 3 VIEW AREA 6 5 4 7 8 θθ 9 500 ㎜ LCM Colorimeter=BM-7 fast PE128128WRF011H01Q Page6 SAMPLE Ver.02 SPEC Edi.005 Note 1. Optical characteristics-2 Viewing angle Rear (12H) φ=90° Top (θ=0°) θL θR θ+ θ- Left (9H) φ=180° Right (3H) φ =0° Front (6H) φ=270° Viewing angle PE128128WRF011H01Q Page7 SAMPLE Ver.02 SPEC Edi.005 Note 2. Optical characteristics-3 Fig.2 Definition of response time Positive Type No selected waveform No selected waveform Selected waveform Transmittance 10% 90% 100% Tf Tr Negative Type No selected waveform No selected Selected waveform Transmittance 100% 90% 10% Tr PE128128WRF011H01Q Tf Page8 SAMPLE Ver.02 SPEC Edi.005 Electrical characteristics-2 ※2 Drive waveform Vop: Drive voltage 1/B: Bias N: Duty fF: Frame frequency fD: Drive frequency (1) Selected waveform 1 2 3 N 1 3 2 V Vop/B Vop/B V 1/fD 1/fF (2) Non- Selected wave form 1 2 3 N 1 2 3 (1-2/B)Vop Vop/B Vop/ (1-2/B)Vop 1/fF 1/fD Note: Frame frequency is defined as follows: Common side supply voltage peak - to - peak /2 = 1 period PE128128WRF011H01Q Page9 SAMPLE Ver.02 SPEC Edi.005 Note 3. : Definition of Vth Selected waveform 100 73% Transmittanc No selected waveform 50% Vth1 Vth2 Drive Active voltage range View direction Drive waveform Transmittance Vth1 10° (Selected waveform) 50% Vth2 40° (No selected waveform) 73% ※1 Contrast ratio = (Brightness in OFF state) / (Brightness in ON state) Outline of Electro-Optical Characteristics Measuring System Photo Detector θ Human Active Temperatur e Control Chamber ψ LCD Panel Transmissive Measuring System: Autronic DMS-803 PE128128WRF011H01Q Page10 SAMPLE Ver.02 SPEC Edi.005 1.6 Backlight & LED Characteristics Maximum Ratings Item Symbol Conditions Forward Current IF Power Dissipation PD Min. Max. Unit Ta =25℃ 40 mA Ta =25℃ 120 mW Electrical / Optical Characteristics Item Symbol Forward Voltage Average Brightness (without LCD) Color of CIE Coordinate (Without LCD) Conditions Min. Typ. Max. Unit VF 3.1 3.3 3.5 V IV 500 700 X 0.260 - 0.315 Y 0.260 - 0.315 IF= 30 mA Color cd/m2 - White A K PE128128WRF011H01Q Page11 SAMPLE Ver.02 SPEC Edi.005 2. MODULE STRUCTURE 2.1 Counter Drawing 2.1.1 LCM Mechanical Diagram * See Appendix 2.1.2 Block Diagram C127 C64 128 X 128 Dots C63 C0. S0 C63 C0. S127 S0 S127 C64 C127 ST7571 A0 CSB SCLK SDA 4 RES VDD XV0 VG VSS V0 VM0 VD1 PS0 PS1 PS2 VPP VE LEDK LEDA PE128128WRF011H01Q 4 5 3 2 2 B/L Page12 SAMPLE Ver.02 SPEC Edi.005 2.2 Interface Pin Description Pin No Symbol 1 NC 2 LEDA Backlight LED Anode input pin. 3 LEDK Backlight LED cathode input pin 4 NC 5 VE 6 VPP 7 VG Connect a capacitor to VSS 8 VD1 Connect a capacitor to VSS 9 XV0 Connect a capacitor to V0 10 V0 Connect a capacitor to XV0 11 VM0 Connect a capacitor to VSS 12 VDD Power supply for system. 13 VSS System ground 14 VDD Power supply for system. 15 SDA serial input data 16 SCLK serial clock input 17 VDD Power supply for system. 18 A0 Register select input pin 19 RST Reset input pin 20 CSB Chip select input pins 21 PS2 PS0 PS1 PS2 Interface mode 22 PS1 L L L 23 PS0 L H L 24 NC PE128128WRF011H01Q Function Dummy Dummy When writing OTP, VE should be pull low. If not used, please let it open When writing OTP, it needs external power supply voltage If not used, please let it open D/C Data R/W Serial clock 3 Line Serial - SDA Write only SCLK 4 Line Serial A0 SDA - SCLK Dummy Page13 SAMPLE Ver.02 SPEC Edi.005 2.3 Timing Characteristics PE128128WRF011H01Q Page14 SAMPLE Ver.02 SPEC Edi.005 PE128128WRF011H01Q Page15 SAMPLE Ver.02 SPEC Edi.005 RESET TIMING PE128128WRF011H01Q Page16 SAMPLE Ver.02 SPEC Edi.005 3. QUALITY ASSURANCE SYSTEM 3.1 Quality Assurance Flow Chart Item Customer Sales Info Marketing & Design R&D Manufactu Product Inventory Purchase ring control control Q.A Survey Request Project Inquiry evaluation Project Validation NG OK Quote Contract Design check Sample test Sample Approval NG Verification NG OK Sample approval OK Pilot Pilot Run & Mass Product NG Verification OK Specification preparation Mass production OK Ship Out PE128128WRF011H01Q run & Reliability test Inspection NG Shipment Ship out Page17 SAMPLE Ver.02 SPEC Edi.005 Item Customer Sales Info Claim R&D Q.A Manufact Product Inventory Purchase uring control control Failure analysis Sales Service Analysis report Corrective action Tracking 1. ISO 9001 Maintenance Activities Q.A 3. Equipment calibration Activity 5. Standardization Management PE128128WRF011H01Q Page18 2. Process improvement proposal 4. Education And Training Activities SAMPLE Ver.02 SPEC Edi.005 3.2 Inspection Specification PE128128WRF011H01Q Page19 SAMPLE Ver.02 SPEC Edi.005 PE128128WRF011H01Q Page20 SAMPLE Ver.02 SPEC Edi.005 PE128128WRF011H01Q Page21 SAMPLE Ver.02 SPEC Edi.005 PE128128WRF011H01Q Page22 SAMPLE Ver.02 SPEC Edi.005 PE128128WRF011H01Q Page23 SAMPLE Ver.02 SPEC Edi.005 PE128128WRF011H01Q Page24 SAMPLE Ver.02 SPEC Edi.005 4. RELIABILITY TEST 4.1 Reliability Test Condition NO. TEST ITEM 1 High Temperature Storage Test 2 Low Temperature Storage Test 3 High Temperature / High Humidity Storage Test 4 Temperature Cycling Storage Test 5 ESD Test 6 Vibration Test (Packaged) 7 Drop Test (Packaged) (Ver.B01) TEST CONDITION Keep in +80 ±2℃ 96 hrs Surrounding temperature, then storage at normal condition 4hrs. Keep in -30 ±2℃ 96 hrs Surrounding temperature, then storage at normal condition 4hrs. Keep in +60 ℃ / 90% R.H duration for 96 hrs Surrounding temperature, then storage at normal condition 4hrs. (Excluding the polarizer) -30℃ → +25℃ → +80℃ → +25℃ (30mins) (5mins) (30mins) (5mins) 10 Cycle Surrounding temperature, then storage at normal condition 4hrs. Air Discharge: Contact Discharge: Apply 2 KV with 5 times Apply 250 V with 5 times Discharge for each polarity +/discharge for each polarity +/1. Temperature ambiance : 15℃∼35℃ 2. Humidity relative : 30%∼60% 3. Energy Storage Capacitance(Cs+Cd) : 150pF±10% 4. Discharge Resistance(Rd) : 330Ω±10% 5. Discharge, mode of operation : Single Discharge (time between successive discharges at least 1 sec) (Tolerance if the output voltage indication : ±5%) 1. Sine wave 10∼55 Hz frequency (1 min/sweep) 2. The amplitude of vibration :1.5 mm 3. Each direction (X、Y、Z) duration for 2 Hrs Packing Weight (Kg) 0 ~ 45.4 Drop Height (cm) 122 45.4 ~ 90.8 76 90.8 ~ 454 61 Over 454 46 Drop Direction :※1 corner / 3 edges / 6 sides each 1time PE128128WRF011H01Q Page25 SAMPLE Ver.02 SPEC Edi.005 5. PRECAUTION RELATING PRODUCT HANDLING 5.1 SAFETY 5.1.1 5.1.2 If the LCD panel breaks , be careful not to get the liquid crystal to touch your skin. If the liquid crystal touches your skin or clothes , please wash it off immediately by using soap and water. 5.2 HANDLING 5.2.1 5.2.2 5.2.3 5.2.4 5.2.5 5.2.6 5.2.7 5.2.8 5.2.9 Avoid any strong mechanical shock which can break the glass. Avoid static electricity which can damage the CMOS LSI—When working with the module , be sure to ground your body and any electrical equipment you may be using. Do not remove the panel or frame from the module. The polarizing plate of the display is very fragile. So , please handle it very carefully, do not touch , push or rub the exposed polarizing with anything harder than an HB pencil lead (glass , tweezers , etc.) Do not wipe the polarizing plate with a dry cloth , as it may easily scratch the surface of plate. Do not touch the display area with bare hands , this will stain the display area. Do not use ketonics solvent & aromatic solvent. Use with a soft cloth soaked with a cleaning naphtha solvent. To control temperature and time of soldering is 320 ± 10°C and 3-5 sec. To avoid liquid (include organic solvent) stained on LCM 5.3 STORAGE 5.3.1 5.3.2 5.3.3 Store the panel or module in a dark place where the temperature is 25°C ± 5°C and the humidity is below 65% RH. Do not place the module near organics solvents or corrosive gases. Do not crush , shake , or jolt the module. 5.4 TERMS OF WARRANTY 5.4.1 5.4.2 Applicable warrant period The period is within thirteen months since the date of shipping out under normal using and storage conditions. Unaccepted responsibility This product has been manufactured to your company’s specification as a part for use in your company’s general electronic products. It is guaranteed to perform according to delivery specifications. For any other use apart from general electronic equipment, we cannot take responsibility if the product is used in nuclear power control equipment, aerospace equipment , fire and security systems or any other applications in which there is a direct risk to human life and where extremely high levels of reliability are required. PE128128WRF011H01Q Page26 SAMPLE Ver.02 SPEC Edi.005