MVAD065 Series www.murata-ps.com 65W 2" x 4" AC-DC Power Supply Converter DESCRIPTION The MVAD065 series switching power supplies utilize advanced component and circuit technologies to deliver high efficiency. Designed for Medical, Telecom, and Industrial applications to satisfy 1U height design considerations, the MVAD065 Series measures only 2.0” x 4.0” x 1.3”. All models offer universal AC input and compliance to worldwide safety and EMC standards. FEATURES ITE (2nd Ed.) and Medical (3rd ed.) MOPP safety approved 55-65W compact high density 2" x 4" standard footprint High efficiency up to 90% Remote Sense Universal AC input Low profile - 1U package Convection-cooled operation up to 65W Complies with 5000m altitude RoHS compliant Input power < 74W UL Class I and II approved Less than 0.3W no load input power Complies with ErP/Energy Star requirement excluding 5V output Available now at http://power.murata.com/acdc3d For full details go to For full details go to www.murata-ps.com/rohs ORDERING GUIDE Model Number MVAD065-05 MVAD065-12 MVAD065-18 MVAD065-24 MVAD065-48 Natural Convection Cooling 55W Main Output (V1) 5V 12V 18V 24V 48V 60W 65W INPUT CHARACTERISTICS Parameter Input Voltage Operating Range Input Frequency Turn-on Input Voltage Turn-off Input Voltage Input Current 5V Inrush Current Other Conditions Single phase DC Input rising at full load Input falling at full load 90Vac input, full load Min. 90 120 47 70 70 Typ. 120/230 50/60 75 60 At 264Vac, at 25°C cold start OUTPUT CHARACTERISTICS Main Output Model Number Load Current Voltage (V1) MVAD065-05 5V 0 to 11A MVAD065-12 12V 0 to 5.0A MVAD065-18 18V 0 to 3.34A MVAD065-24 24V 0 to 2.71A MVAD065-48 48V 0 to 1.36A Load Capacitance 0 to 2200μF 0 to 1000µF 0 to 680μF 0 to 560µF 0 to 330µF Parameter Conditions Transient Response Settling Time to 1% of Nominal Turn On Delay Output Voltage Rise Setpoint Accuracy Output Holdup Temperature Coefficient Ripple Voltage & Noise1 50% load step, 1A/µsec slew rate Min. 10 Units Vac Vdc Hz Vac A Apk Line, Load, Cross Regulation ± 2% ± 2% ± 2% ± 2% ± 2% MAIN OUTPUT CHARACTERISTICS After application of input power Monotonic, 0 to 100% load 120Vac, 40W, 25°C 115Vac, 100% load Max. 264 300 63 85 85 1.4 Typical Efficiency @230Vac full load 84% 88% 86% 89% 90% Max. Other ±5 500 200 1 50 ±1 ±0.5 5V 0.02 % µsec sec msec % msec %/°C % 1 Compensates for up to 400mV of lead drop with remote sense Remote Sense3 400 mV connected. Protected against short circuit and reverse connection. 1.Ripple and noise are measured with 0.1 uF of ceramic capacitance and 47 uF of electrolytic capacitance on each of the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short coaxial cable with 50ohm scope termination is used. 2.Unless otherwise specified all readings are taken at 120Vac input and 25°C ambient temperature. 3.0.4V lead drop is compensated in remote sense. REG.-Nr. C457 2 Units CB Test Certificate and Test Report www.murata-ps.com/rohs power.murata.com MVAD065.B01 Page 1 of 7 MVAD065 Series 65W 2" x 4" AC-DC Power Supply Converter ENVIRONMENTAL CHARACTERISTICS Parameter Conditions Min. Storage Temperature Range Operating Temperature Range Operating Humidity Operating Altitude MTBF Shock Vibration See thermal derating curves Start up Non-condensing For Class I ITE Equipment deployment Other Telcordia SR-332 M1C3 25°C Operating, IEC60068-2-27, half-sine 5G, 6ms, 3 times per face, 6 faces Typ. -40 -10 -20 10 -200 -200 1M Max. Units 85 70 °C 95 5000 2000 Complies Non-operating, IEC60068-2-27, half-sine, 30G, 18ms, 3 times per face, 6 faces Complies Operating, IEC60068-2-6, 1.0G, 10-150Hz, 10 minutes per axis, on all 3 axes Complies Non-operating, IEC60068-2-6, 2.0G, 10-150Hz, 10 minutes per axis, on all 3 axes Complies Safety Warranty Outside Dimensions 2 years 2.0" x 4.0" x 1.3" (50.8mm x 101.6mm x 33.02mm) Weight MVAD065-05 / MVAD065-18 Other Conditions Latching (50% load) Latching (60% load) Hiccup mode m Hours IEC60950-1:2005 (2nd Edition); Am1:2009 UL60950-1 2nd Edition,2011-12-19, CSA C22.2 No. 60950-1-07, 2nd Edition,2011-12 EN60950-1:2006 + A11:2009 + A1:2010 + A12:2011 IEC60601-1:2005 + CORR.1(2006) + CORR.2(2007) ANSI/AAMI ES60601-1 (2005+C1:09 + A2:10), CSA-C22.2 No. 60601-1(2008), MOPP CE Marking per LVD PROTECTION CHARACTERISTICS Parameter MVAD065-05 Overvoltage Protection Other Overcurrent Protection % 0.285lbs (130g) typical 0.27lbs (123g) typical Min. 110 110 110 Typ. Conditions Min. Typ. Primary to Earth Ground (1xMOPP) Primary to Secondary (2xMOPP)4 Secondary to Earth Ground 240Vac, 60Hz, 25°C 264Vac, 60Hz, 25°C 264Vac, 60Hz, 25°C 1500 4000 500 Max. 190 160 160 Units %V1 Max. Units %A ISOLATION CHARACTERISTICS Parameter Isolation Leakage Current (under normal conditions) Touch Current Vac Vdc 300 350 100 µA EMISSIONS AND IMMUNITY Characteristic Standard Compliance Input Current Harmonics Voltage Fluctuation and Flicker IEC/EN 61000-3-2 IEC/EN 61000-3-3 EN 55022 FCC Part 15 IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 IEC/EN 61000-4-8 IEC/EN 61000-4-11 Class A Complies Class B, Class A (at Class II equipment) Class B, Class A (at Class II equipment) Level 4, Criterion A Level 2, Criterion A Level 3, Criterion A Level 4, Criterion A Level 2, Criterion A Level 2, Criterion A Level 3, Criterion B Conducted Emissions ESD Immunity Radiated Field Immunity Electrical Fast Transient Immunity Surge Immunity RF Conducted Immunity Magnetic Field Immunity Voltage dips, interruptions 4.At class I equipment. power.murata.com MVAD065.B01 Page 2 of 7 MVAD065 Series 65W 2" x 4" AC-DC Power Supply Converter EMI CONSIDERATIONS For optimum EMI performance, the power supply should be mounted to a metal plate grounded to all 4 mounting holes of the power supply. To comply with safety standards, this plate must be properly grounded to protective earth (see mechanical dimension notes). Pre-compliance testing has shown the standalone power supply to comply with EN55022 class A radiated emissions. Radiated emission results vary with system enclosure and cable routing paths. SAFETY CONSIDERATIONS 1.This power supply is a component level power supply intended for use in class I or class II applications. Secondary ground traces need to be suitably isolated from primary ground traces when used in class II applications. 2.When the power supply is used in class II equipment, all ground traces and components connected to the primary side are considered primary for spacing and insulation considerations. 3.Double pole/neutral fusing. PERFORMANCE DATA MVAD065-12 Efficiency (%) MVAD065-05 Efficiency (%) 95 93 91 89 87 85 83 81 79 77 75 93 91 89 87 85 83 81 90Vac 115Vac 230Vac 264Vac 79 77 75 73 0.00 2.00 4.00 6.00 8.00 10.00 Output Current (A) 12.00 MVAD065-18 Efficiency (%) 95 93 91 89 87 85 83 81 79 77 75 93 91 89 87 85 90Vac 115Vac 230Vac 264Vac 81 79 77 75 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 0.00 1.00 2.00 3.00 4.00 5.00 Output Current (A) 95 83 90Vac 115Vac 230Vac 264Vac 4.00 MVAD065-24 Efficiency (%) 90Vac 115Vac 230Vac 264Vac 0.00 0.50 1.00 1.50 2.00 2.50 3.00 Output Current (A) Output Current (A) MVAD065-48 Efficiency (%) 95 93 91 89 87 85 83 81 79 77 75 0.00 90Vac 115Vac 230Vac 264Vac 0.20 0.40 0.60 0.80 1.00 1.20 1.40 Output Current (A) power.murata.com MVAD065.B01 Page 3 of 7 MVAD065 Series 65W 2" x 4" AC-DC Power Supply Converter PERFORMANCE DATA Output power (%) Output power (W) Thermal Derating (Other) MVAD065-05 Thermal Derating 60 50 40 30 100 80 60 40 20 20 10 0 0 -10 10 30 50 70 Ambient temp. ( ) -10 10 30 50 70 Ambient temp. ( ) Inrush waveform (AC264V 25°C) power.murata.com MVAD065.B01 Page 4 of 7 MVAD065 Series 65W 2" x 4" AC-DC Power Supply Converter MECHANICAL DIMENSIONS – MVAD065-05 ONLY Output Voltage Adjust Pot for Factory Use Φ0.156±0.05 4 Places Maximum Screw Head DIAMETER Maximum earth ground contact area PCB top and bottom DIAMETER Φ0.236" (6.0) ※1 Preferred screw type M3 (Metric screw threads) No.4-40UNC (United thread Standard) All dimensions in inches (mm). tolerance is +/-0.02’ (0.5) Mounting holes H1 and H2 should be earth-grounded for EMI purpose Mounting holes H2 is earth ground connection This power supply requires mounting on standoffs minimum 0.2' (5.0) in height Dimensions: 2.0" x 4.0" x 1.3" (50.8mm x 101.6mm x 33.02mm) INPUT/OUTPUT CONNECTOR AND SIGNAL SPECIFICATION AND MATING CONNECTORS PIN Description Input Connector CN1 : Molex 26-62-4030 1 AC Line (V-) 3 AC Neutral (V+) Spade Connector: #250 GND Earth Ground Output Connector CN2 : Molex 26-60-4060 1, 2 V1 3, 4 DC Return 5 -Remote Sense (NC) 6 +Remote Sense Mating Housing Crimp terminal/pins Molex 09-50-8031 with locking ramp Molex 6838 Series Molex 09-50-8061 with locking ramp Molex 6838 Series power.murata.com MVAD065.B01 Page 5 of 7 MVAD065 Series 65W 2" x 4" AC-DC Power Supply Converter MECHANICAL DIMENSIONS – MVAD065-12x ONLY All dimensions in inches (mm). tolerance is +/-0.02’ (0.5) Mounting holes H1 and H2 should be earth-grounded for EMI purpose Mounting holes H2 is earth ground connection This power supply requires mounting on standoffs minimum 0.2' (5.0) in height Dimensions: 2.0" x 4.0" x 1.3" (50.8mm x 101.6mm x 33.02mm) INPUT/OUTPUT CONNECTOR AND SIGNAL SPECIFICATION AND MATING CONNECTORS PIN Description Input Connector CN1 : Molex 26-62-4030 1 AC Line (V-) 3 AC Neutral (V+) Spade Connector: #250 GND Earth Ground Output Connector CN2 : Molex 26-60-4060 1, 2 V1 3, 4 DC Return 5 -Remote Sense (NC) 6 +Remote Sense Mating Housing Crimp terminal/pins Molex 09-50-8031 with locking ramp Molex 6838 Series Molex 09-50-8061 with locking ramp Molex 6838 Series power.murata.com MVAD065.B01 Page 6 of 7 MVAD065 Series 65W 2" x 4" AC-DC Power Supply Converter MECHANICAL DIMENSIONS – MVAD065-xx 24V and 48V MODELS All dimensions in inches (mm). tolerance is +/-0.02’ (0.5) Mounting holes H1 and H2 should be earth-grounded for EMI purpose Mounting holes H2 is earth ground connection This power supply requires mounting on standoffs minimum 0.2' (5.0) in height Dimensions: 2.0" x 4.0" x 1.3" (50.8mm x 101.6mm x 33.02mm) INPUT/OUTPUT CONNECTOR AND SIGNAL SPECIFICATION AND MATING CONNECTORS PIN Description Input Connector CN1 : Molex 26-62-4030 1 AC Line (V-) 3 AC Neutral (V+) Spade Connector: #250 GND Earth Ground Output Connector CN2 : Molex 26-60-4060 1, 2 V1 3, 4 DC Return 5 -Remote Sense (NC) 6 +Remote Sense Mating Housing Crimp terminal/pins Molex 09-50-8031 with locking ramp Molex 6838 Series Molex 09-50-8061 with locking ramp Molex 6838 Series Murata Manufacturing Co., Ltd. Power Device Product Division Nagaokakyo-shi, Kyoto 617-8555 Japan ISO 9001 and 14001 REGISTERED This product is subject to operating requirements and the Life and Safety Critical Application Policy. Click here to view policy. Please contact us regarding restricted materials compliance beyond the RoHS directive. Murata makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify Murata, its affiliated companies, and its representatives against any damages arising out of the use of any Murata products in safety-critical applications. Specifications are subject to change without notice. © 2015 Murata Manufacturing Co., Ltd. All Rights Reserved. power.murata.com MVAD065.B01 Page 7 of 7