MVAD065-12 - power, Murata

MVAD065 Series
www.murata-ps.com
65W 2" x 4" AC-DC Power Supply Converter
DESCRIPTION
The MVAD065 series switching power supplies utilize advanced component and circuit technologies
to deliver high efficiency. Designed for Medical, Telecom, and Industrial applications to satisfy 1U
height design considerations, the MVAD065 Series measures only 2.0” x 4.0” x 1.3”. All models offer
universal AC input and compliance to worldwide safety and EMC standards.
FEATURES
„„
ITE (2nd Ed.) and Medical (3rd ed.) MOPP
safety approved
„„
55-65W compact high density
„„
2" x 4" standard footprint
„„
High efficiency up to 90%
„„
Remote Sense
„„
Universal AC input
„„
Low profile - 1U package
„„
Convection-cooled operation up to 65W
„„
Complies with 5000m altitude
„„
RoHS compliant
„„
Input power < 74W
„„
UL Class I and II approved
„„
Less than 0.3W no load input power
„„
Complies with ErP/Energy Star requirement
excluding 5V output
Available now at
http://power.murata.com/acdc3d
For full details go to
For
full details go to
www.murata-ps.com/rohs
ORDERING GUIDE
Model Number
MVAD065-05
MVAD065-12
MVAD065-18
MVAD065-24
MVAD065-48
Natural Convection Cooling
55W
Main Output (V1)
5V
12V
18V
24V
48V
60W
65W
INPUT CHARACTERISTICS
Parameter
Input Voltage Operating Range
Input Frequency
Turn-on Input Voltage
Turn-off Input Voltage
Input Current
5V
Inrush Current
Other
Conditions
Single phase
DC
Input rising at full load
Input falling at full load
90Vac input, full load
Min.
90
120
47
70
70
Typ.
120/230
50/60
75
60
At 264Vac, at 25°C cold start
OUTPUT CHARACTERISTICS
Main Output
Model Number
Load Current
Voltage (V1)
MVAD065-05
5V
0 to 11A
MVAD065-12
12V
0 to 5.0A
MVAD065-18
18V
0 to 3.34A
MVAD065-24
24V
0 to 2.71A
MVAD065-48
48V
0 to 1.36A
Load Capacitance
0 to 2200μF
0 to 1000µF
0 to 680μF
0 to 560µF
0 to 330µF
Parameter
Conditions
Transient Response
Settling Time to 1% of Nominal
Turn On Delay
Output Voltage Rise
Setpoint Accuracy
Output Holdup
Temperature Coefficient
Ripple Voltage & Noise1
50% load step, 1A/µsec slew rate
Min.
10
Units
Vac
Vdc
Hz
Vac
A
Apk
Line, Load, Cross
Regulation
± 2%
± 2%
± 2%
± 2%
± 2%
MAIN OUTPUT CHARACTERISTICS
After application of input power
Monotonic, 0 to 100% load
120Vac, 40W, 25°C
115Vac, 100% load
Max.
264
300
63
85
85
1.4
Typical Efficiency
@230Vac full load
84%
88%
86%
89%
90%
Max.
Other
±5
500 200
1
50
±1 ±0.5
5V
0.02
%
µsec
sec
msec
%
msec
%/°C
%
1
Compensates for up to 400mV
of lead drop with remote sense
Remote Sense3
400
mV
connected. Protected against short
circuit and reverse connection.
1.Ripple and noise are measured with 0.1 uF of ceramic capacitance and 47 uF of electrolytic capacitance on each
of the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short
coaxial cable with 50ohm scope termination is used.
2.Unless otherwise specified all readings are taken at 120Vac input and 25°C ambient temperature.
3.0.4V lead drop is compensated in remote sense.
REG.-Nr. C457
2
Units
CB
Test Certificate
and Test Report
www.murata-ps.com/rohs
power.murata.com
MVAD065.B01 Page 1 of 7
MVAD065 Series
65W 2" x 4" AC-DC Power Supply Converter
ENVIRONMENTAL CHARACTERISTICS
Parameter
Conditions
Min.
Storage Temperature Range
Operating Temperature Range
Operating Humidity
Operating Altitude
MTBF
Shock
Vibration
See thermal derating curves
Start up
Non-condensing
For Class I ITE Equipment deployment
Other
Telcordia SR-332 M1C3 25°C
Operating, IEC60068-2-27, half-sine 5G, 6ms,
3 times per face, 6 faces
Typ.
-40
-10
-20
10
-200
-200
1M
Max.
Units
85
70
°C
95
5000
2000
Complies
Non-operating, IEC60068-2-27, half-sine,
30G, 18ms, 3 times per face, 6 faces
Complies
Operating, IEC60068-2-6, 1.0G, 10-150Hz, 10
minutes per axis, on all 3 axes
Complies
Non-operating, IEC60068-2-6, 2.0G,
10-150Hz, 10 minutes per axis, on all 3 axes
Complies
Safety
Warranty
Outside Dimensions
2 years
2.0" x 4.0" x 1.3" (50.8mm x 101.6mm x 33.02mm)
Weight
MVAD065-05 / MVAD065-18
Other
Conditions
Latching (50% load)
Latching (60% load)
Hiccup mode
m
Hours
IEC60950-1:2005 (2nd Edition); Am1:2009
UL60950-1 2nd Edition,2011-12-19, CSA C22.2 No. 60950-1-07, 2nd Edition,2011-12
EN60950-1:2006 + A11:2009 + A1:2010 + A12:2011
IEC60601-1:2005 + CORR.1(2006) + CORR.2(2007)
ANSI/AAMI ES60601-1 (2005+C1:09 + A2:10), CSA-C22.2 No. 60601-1(2008), MOPP
CE Marking per LVD
PROTECTION CHARACTERISTICS
Parameter
MVAD065-05
Overvoltage Protection
Other
Overcurrent Protection
%
0.285lbs (130g) typical
0.27lbs (123g) typical
Min.
110
110
110
Typ.
Conditions
Min.
Typ.
Primary to Earth Ground (1xMOPP)
Primary to Secondary (2xMOPP)4
Secondary to Earth Ground
240Vac, 60Hz, 25°C
264Vac, 60Hz, 25°C
264Vac, 60Hz, 25°C
1500
4000
500
Max.
190
160
160
Units
%V1
Max.
Units
%A
ISOLATION CHARACTERISTICS
Parameter
Isolation
Leakage Current (under normal conditions)
Touch Current
Vac
Vdc
300
350
100
µA
EMISSIONS AND IMMUNITY
Characteristic
Standard
Compliance
Input Current Harmonics
Voltage Fluctuation and Flicker
IEC/EN 61000-3-2
IEC/EN 61000-3-3
EN 55022
FCC Part 15
IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
IEC/EN 61000-4-8
IEC/EN 61000-4-11
Class A
Complies
Class B, Class A (at Class II equipment)
Class B, Class A (at Class II equipment)
Level 4, Criterion A
Level 2, Criterion A
Level 3, Criterion A
Level 4, Criterion A
Level 2, Criterion A
Level 2, Criterion A
Level 3, Criterion B
Conducted Emissions
ESD Immunity
Radiated Field Immunity
Electrical Fast Transient Immunity
Surge Immunity
RF Conducted Immunity
Magnetic Field Immunity
Voltage dips, interruptions
4.At class I equipment.
power.murata.com
MVAD065.B01 Page 2 of 7
MVAD065 Series
65W 2" x 4" AC-DC Power Supply Converter
EMI CONSIDERATIONS
For optimum EMI performance, the power supply should be mounted to a metal plate grounded to all 4 mounting holes of the power supply. To comply with
safety standards, this plate must be properly grounded to protective earth (see mechanical dimension notes). Pre-compliance testing has shown the standalone power supply to comply with EN55022 class A radiated emissions. Radiated emission results vary with system enclosure and cable routing paths.
SAFETY CONSIDERATIONS
1.This power supply is a component level power supply intended for use in class I or class II applications. Secondary ground traces need to be suitably isolated from primary ground traces when used in class II applications.
2.When the power supply is used in class II equipment, all ground traces and components connected to the primary side are considered primary for
spacing and insulation considerations.
3.Double pole/neutral fusing.
PERFORMANCE DATA
MVAD065-12 Efficiency (%)
MVAD065-05 Efficiency (%)
95
93
91
89
87
85
83
81
79
77
75
93
91
89
87
85
83
81
90Vac
115Vac
230Vac
264Vac
79
77
75
73
0.00
2.00
4.00
6.00
8.00
10.00
Output Current (A)
12.00
MVAD065-18 Efficiency (%)
95
93
91
89
87
85
83
81
79
77
75
93
91
89
87
85
90Vac
115Vac
230Vac
264Vac
81
79
77
75
0.00
0.50
1.00
1.50
2.00
2.50
3.00
3.50
0.00
1.00
2.00
3.00
4.00
5.00
Output Current (A)
95
83
90Vac
115Vac
230Vac
264Vac
4.00
MVAD065-24 Efficiency (%)
90Vac
115Vac
230Vac
264Vac
0.00
0.50
1.00
1.50
2.00
2.50
3.00
Output Current (A)
Output Current (A)
MVAD065-48 Efficiency (%)
95
93
91
89
87
85
83
81
79
77
75
0.00
90Vac
115Vac
230Vac
264Vac
0.20
0.40
0.60
0.80
1.00
1.20
1.40
Output Current (A)
power.murata.com
MVAD065.B01 Page 3 of 7
MVAD065 Series
65W 2" x 4" AC-DC Power Supply Converter
PERFORMANCE DATA
Output power (%)
Output power (W)
Thermal Derating (Other)
MVAD065-05 Thermal Derating
60
50
40
30
100
80
60
40
20
20
10
0
0
-10
10
30
50
70
Ambient temp. ( )
-10
10
30
50
70
Ambient temp. ( )
Inrush waveform (AC264V 25°C)
power.murata.com
MVAD065.B01 Page 4 of 7
MVAD065 Series
65W 2" x 4" AC-DC Power Supply Converter
MECHANICAL DIMENSIONS – MVAD065-05 ONLY
Output Voltage Adjust Pot
for Factory Use
Φ0.156±0.05
4 Places
Maximum Screw Head DIAMETER
Maximum earth ground contact area
PCB top and bottom
DIAMETER Φ0.236" (6.0)
※1 Preferred screw type
M3 (Metric screw threads)
No.4-40UNC (United thread Standard)
All dimensions in inches (mm). tolerance is +/-0.02’ (0.5)
Mounting holes H1 and H2 should be earth-grounded for EMI purpose
Mounting holes H2 is earth ground connection
This power supply requires mounting on standoffs minimum 0.2' (5.0) in height
Dimensions: 2.0" x 4.0" x 1.3" (50.8mm x 101.6mm x 33.02mm)
INPUT/OUTPUT CONNECTOR AND SIGNAL SPECIFICATION AND MATING CONNECTORS
PIN
Description
Input Connector CN1 : Molex 26-62-4030
1
AC Line (V-)
3
AC Neutral (V+)
Spade Connector: #250
GND
Earth Ground
Output Connector CN2 : Molex 26-60-4060
1, 2
V1
3, 4
DC Return
5
-Remote Sense (NC)
6
+Remote Sense
Mating Housing
Crimp terminal/pins
Molex 09-50-8031 with locking ramp
Molex 6838 Series
Molex 09-50-8061 with locking ramp
Molex 6838 Series
power.murata.com
MVAD065.B01 Page 5 of 7
MVAD065 Series
65W 2" x 4" AC-DC Power Supply Converter
MECHANICAL DIMENSIONS – MVAD065-12x ONLY
All dimensions in inches (mm). tolerance is +/-0.02’ (0.5)
Mounting holes H1 and H2 should be earth-grounded for EMI purpose
Mounting holes H2 is earth ground connection
This power supply requires mounting on standoffs minimum 0.2' (5.0) in height
Dimensions: 2.0" x 4.0" x 1.3" (50.8mm x 101.6mm x 33.02mm)
INPUT/OUTPUT CONNECTOR AND SIGNAL SPECIFICATION AND MATING CONNECTORS
PIN
Description
Input Connector CN1 : Molex 26-62-4030
1
AC Line (V-)
3
AC Neutral (V+)
Spade Connector: #250
GND
Earth Ground
Output Connector CN2 : Molex 26-60-4060
1, 2
V1
3, 4
DC Return
5
-Remote Sense (NC)
6
+Remote Sense
Mating Housing
Crimp terminal/pins
Molex 09-50-8031 with locking ramp
Molex 6838 Series
Molex 09-50-8061 with locking ramp
Molex 6838 Series
power.murata.com
MVAD065.B01 Page 6 of 7
MVAD065 Series
65W 2" x 4" AC-DC Power Supply Converter
MECHANICAL DIMENSIONS – MVAD065-xx 24V and 48V MODELS
All dimensions in inches (mm). tolerance is +/-0.02’ (0.5)
Mounting holes H1 and H2 should be earth-grounded for EMI purpose
Mounting holes H2 is earth ground connection
This power supply requires mounting on standoffs minimum 0.2' (5.0) in height
Dimensions: 2.0" x 4.0" x 1.3" (50.8mm x 101.6mm x 33.02mm)
INPUT/OUTPUT CONNECTOR AND SIGNAL SPECIFICATION AND MATING CONNECTORS
PIN
Description
Input Connector CN1 : Molex 26-62-4030
1
AC Line (V-)
3
AC Neutral (V+)
Spade Connector: #250
GND
Earth Ground
Output Connector CN2 : Molex 26-60-4060
1, 2
V1
3, 4
DC Return
5
-Remote Sense (NC)
6
+Remote Sense
Mating Housing
Crimp terminal/pins
Molex 09-50-8031 with locking ramp
Molex 6838 Series
Molex 09-50-8061 with locking ramp
Molex 6838 Series
Murata Manufacturing Co., Ltd. Power Device Product Division
Nagaokakyo-shi, Kyoto 617-8555 Japan
ISO 9001 and 14001 REGISTERED
This product is subject to operating requirements and the Life and
Safety Critical Application Policy. Click here to view policy.
Please contact us regarding restricted materials compliance beyond
the RoHS directive.
Murata makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or
sell equipment constructed in accordance therewith. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might
cause harm, and take appropriate remedial actions. Buyer will fully indemnify Murata, its affiliated companies, and its representatives against any damages arising out of the use of any Murata products in safety-critical applications. Specifications are subject to change without notice.
© 2015 Murata Manufacturing Co., Ltd. All Rights Reserved.
power.murata.com
MVAD065.B01 Page 7 of 7