APM-40 SERIES AC/DC Power Module 40W, Industrial & Medical Safety FEATURES ►Fully Encapsulated Plastic Case for PCB, Chassis and DIN-Rail Mounting Version ►Universal Input 85~264VAC, 47~440Hz ►Protection Class II as per IEC/EN 60536 ►I/O Isolation 4000VAC with Reinforced Insulation ►Operating Temp. Range -40℃ to +80℃ ►Overload/Voltage/Temp. and Short Circuit Protection ►EMI Emission meets EN55011/22 Class B & FCC Level B ►EMC Immunity meets EN61000-4-2,3,4,5,6,8,11 ►UL/cUL/IEC/EN 60950-1 and UL508 Safety Approval ►Medical Safety meets 2xMOPP per 3rd Edition of IEC/EN 60601-1 & ANSI/AAMI ES60601-1 ►CE Marking with EMC and LVD PRODUCT OVERVIEW The new MINMAX APM-40 series is a range of fully encapsulated AC/DC power modules. These high performance products feature an extended operating temperature range of -40°C to +80°C. Universal input voltage 85-264VAC and UL/IEC/EN safety approvals including medical safety and UL508 listing qualify these power supplies modules for applications in products with worldwide markets.EMI-filter meets EN55022, class B and FCC,part15, class B. The APM-40 series power modules provide an economical solution for many space critical applications in commercial, medical and industrial electronic equipment. Model Selection Guide Model Number Output Voltage Output Current Input Current 115VAC, 60Hz 230VAC, 50Hz Max. @Max. Load VDC mA mA(typ.) APM-40S05 5 8000 716 APM-40S12 12 3330 APM-40S15 15 2660 APM-40S24 24 APM-40D12 APM-40D15 Max. capacitive Load Efficiency (typ.) @Max. Load, 115VAC μF % 429 8000 81 689 414 3900 84 680 408 3900 85 1660 687 413 680 84 ±12 ±1660 687 413 1500# 84 ±15 ±1330 680 408 1000# 85 # For each output Input Specifications Parameter Model Min. Typ. Max. Unit AC Voltage Input Range 85 --- 264 VAC Input Frequency Range 47 --- 440 Hz 120 --- 370 VDC All Models DC Voltage Input Range No-Load Power Consumption Inrush Current (Cold Start at 25℃) E-mail:[email protected] 2015/05/22 REV:2 --- --- 0.3 W 115VAC --- --- 30 A 230VAC --- --- 60 A Tel:886-6-2923150 Page 1 of 5 APM-40 SERIES AC/DC Power Module 40W, Industrial & Medical Safety Output Specifications Parameter Conditions Output Voltage Accuracy Line Regulation Min. Typ. --±2.0 Vin=Min. to Max. @Full Load --±0.5 Single Output Model --±1.0 Io=0% to 100% Dual Output Models --±2.0 No minimum Load Requirement 5V Output Models 1.5 --0-20 MHz Bandwidth Other Output Models 1.0 --Zener diode clamp 120 ----±0.02 ----85VAC, Hiccup Mode, auto-recovery 105 --(long term overload condition may cause damage) Hiccup mode, indefinite (Automatic Recovery) Load Regulation Minimum Load Ripple & Noise(3) Over Voltage Protection Temperature Coefficient Overshoot Current Limitation Short Circuit Protection Max. Unit --------- %Vom. % % % 1.8 1.3 ----5 %VPP of Vo %VPP of Vo % of Vo %/℃ % --- % Inom. General Specifications Parameter I/O Isolation Voltage Leakage Current I/O Isolation Resistance Switching Frequency Conditions Min. Typ. Max. Unit Reinforced Insulation, Rated For 60 Seconds 4000 --1000 ------- --80 --130 25 80 200,000 ------------- VACrms μA MΩ KHz ms ms Hours 500 VDC 115VAC, 60Hz 230VAC, 50Hz MIL-HDBK-217F@25℃, Ground Benign Hold-up Time MTBF (calculated) Protection Class II According IEC/EN 60536 IEC/EN 60950-1 CB Report, UL/cUL 60950-1, CSA-C22.2 No.60950-1, UL508 listed certificate IEC/EN 60601-1 3rd Edition CB Report, ANSI/AAMI ES60601-1 2XMOPP, CAN/CSA-C22.2 No.60601-1 certificate Safety Approvals EMC Specifications Parameter Standards & Level Performance Conduction EN55011, EN55022, EN61000-6-4, EN61000-6-3, FCC part 15 Radiation EN60601-1-2, EN55024, EN61000-6-2, EN61000-6-1 ESD EN61000-4-2 Air ± 8kV , Contact ± 4kV Radiated immunity EN61000-4-3 10V/m Fast transient EN61000-4-4 ±2kV Surge EN61000-4-5 ±1kV EN61000-4-6 10Vrms Conducted immunity EN61000-4-8 30A/m PFMF EN61000-4-11 30% 10ms Dips EN61000-4-11 >95% 5000ms Interruptions EMI EMS Class B A A A A A A A B Environmental Specifications Parameter Conditions Min. Max. Temperature Range (operational) Power Derating Storage Temperature Range Over Temperature Protection Humidity (non condensing) Cooling Lead Temperature (1.5mm from case for 10Sec.) Ambient Above +60℃ -40℃ +80℃ 1.5W / ℃ +95℃ E-mail:[email protected] 2015/05/22 REV:2 -40℃ Shutdown at 90℃ (automatic recovery at approx. 67℃) --Natural Convection --- Tel:886-6-2923150 Page 2 of 5 95% rel. H 260℃ APM-40 SERIES AC/DC Power Module 40W, Industrial & Medical Safety Notes 1 This product is not designed for use in critical life support systems, equipment used in hazardous environment, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. Specifications typical at Ta=+25℃, resistive load, 115VAC, 60Hz input voltage, after warm-up time rated output current unless otherwise noted. Ripple & Noise measured with a 0.1μF/50V MLCC and a 1μF/50V Aluminum electrolytic. Safety approvals cover frequency 47-63 Hz. We recommend to protect the converter by a slow blow fuse in the input supply line. Other input and output voltage may be available, please contact factory. That “natural convection” is about 20LFM but is not equal to still air (0 LFM). Specifications are subject to change without notice. 2 3 4 5 6 7 8 Package Specifications PCB Mounting Mechanical Dimensions Pin Connections 12.7 [0.50] 6 4 0.7 [0.03] 3 Pin Single Output Dual Output 1 AC (N) AC (N) 2 AC (L) AC (L) 3 +Vout +Vout 4 No Pin No Pin 5 -Vout Common 6 No Pin No Pin 7 NC -Vout [ 7 5 6.0 [0.24] 15.24 [0.60] 12.7 [0.50] 1.0 0.04] 15.24 [0.60] 30.0 [1.18] 15.9 [0.63] 88.9 [3.50] 81.3 [3.20] 31.6 [1.24] NC: No Connection 53.3 [2.10] Mounting M4.0 Thread Bottom View 2 1 5.0 [0.20] ►All dimensions in mm 55.88 [2.20] 63.5 [2.50] Physical Characteristics Case Size : 88.9x63.5x30.0mm (3.50x2.50x1.18 inches) Case Material : Plastic resin (flammability to UL 94V-0 rated) Pin Material : Copper Alloy with Gold Plate Over Nickel Subplate Weight : 310g E-mail:[email protected] 2015/05/22 REV:2 Tel:886-6-2923150 Page 3 of 5 ►Tolerance: ►Pin (inches) ±0.5 (±0.02) diameter 1.0 ±0.1 (0.04±0.004) APM-40 SERIES AC/DC Power Module 40W, Industrial & Medical Safety Package Specifications Chassis Mounting (order code suffix C) Mechanical Dimensions Connections Indication LED 2 Top view 1 63.8 [2.51] 7 6 5 4 3 50.0 [1.97] 4 x 3.5 DCON POWER "GOOD" INDICATOR Pin Single Output Dual Output 1 AC (N) AC (N) 2 AC (L) AC (L) 3 +Vout +Vout 4 NC NC 5 -Vout Common 6 NC NC 7 NC -Vout 100.0 [3.94] 112.0 [4.41] NC: No Connection 92.0 [3.62] 16.8 [0.66] 5.0 [0.20] 34.1 [1.34] 10.0 [0.39] Physical Characteristics Case Size : 112.0x63.8x34.1mm (4.41x2.51x1.34 inches) Case Material : Plastic resin (flammability to UL 94V-0 rated) Weight : 320g Package Specifications with DIN Rail Mounting Bracket Mechanical Dimensions 7 6 5 4 3 Indication LED Top view 2 1 63.8 [2.51] 3.5 50.0 [1.97] 4x DCON POWER "GOOD" INDICATOR 100.0 [3.94] 112.0 [4.41] 34.1 [1.34] 11.0 [0.43] 3.0 [0.12] 5.0 [0.20] 10.0 [0.39] 16.8 [0.66] 92.0 [3.62] Physical Characteristics Case Size : 112.0x63.8x34.1mm (4.41x2.51x1.34 inches) Case Material : Plastic resin (flammability to UL 94V-0 rated) Weight : 374g E-mail:[email protected] 2015/05/22 REV:2 Tel:886-6-2923150 Page 4 of 5 ►All dimensions in mm ►Tolerance: (inches) ±0.5 (±0.02) APM-40 SERIES AC/DC Power Module 40W, Industrial & Medical Safety DIN-Rail Mounting Bracket (Order code for Kit : AC-DIN-02) Order Code Table PCB Mounting APM-40S05 Chassis Mounting APM-40S05C With DIN Rail Mounting by two Order Code APM-40S05C AC-DIN-02 APM-40S12 APM-40S12C APM-40S12C AC-DIN-02 APM-40S15 APM-40S15C APM-40S15C AC-DIN-02 APM-40S24 APM-40S24C APM-40S24C AC-DIN-02 APM-40D12 APM-40D12C APM-40D12C AC-DIN-02 APM-40D15 APM-40D15C APM-40D15C AC-DIN-02 APM-40S05 APM-40S05C APM-40S05C AC-DIN-02 Minmax Technology Co., Ltd. 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected] 2015/05/22 REV:2 Page 5 of 5