MA01-HI SERIES DC/DC CONVERTER 1W, High Isolation,SIP-Package FEATURES ►Industrial Standard SIP-7 Package ►Ultra-high I/O Isolation 5200VDC ►Common Mode Transient Immunity : 15KV/µs ►Qualified for IGBT and High Isolation Applications ►Operating Ambient Temp. Range -40℃ to +95℃ ►UL/cUL/IEC/EN 60950-1 Safety Approval PRODUCT OVERVIEW The MINMAX MA01-HI series is a new range of isolated 1W DC/DC converter modules in SIP-package which feature a very high I/O-isolation voltage rated for 5200V.A very high common mode transient immunity qualifies these product for IGBT applications.There are 40 Models available for 5, 12, 15 or 24VDC input.These converters offer a cost-effective solution for all applications where a very high I/O –isolation is required. Model Selection Guide Model Number MA01-05S033HI MA01-05S05HI MA01-05S09HI MA01-05S12HI MA01-05S15HI MA01-05D05HI MA01-05D09HI MA01-05D12HI MA01-05D15HI Input Voltage (Range) VDC 5 ±10% MA01-05A1509HI MA01-12S033HI MA01-12S05HI MA01-12S09HI MA01-12S12HI MA01-12S15HI MA01-12D05HI MA01-12D09HI MA01-12D12HI MA01-12D15HI 12 ±10% MA01-12A1509HI MA01-15S033HI MA01-15S05HI MA01-15S09HI MA01-15S12HI MA01-15S15HI MA01-15D05HI MA01-15D09HI MA01-15D12HI MA01-15D15HI 15 ±10% MA01-15A1509HI MA01-24S033HI MA01-24S05HI MA01-24S09HI MA01-24S12HI MA01-24S15HI MA01-24D05HI MA01-24D09HI MA01-24D12HI MA01-24D15HI 24 ±10% MA01-24A1509HI E-mail:[email protected] 2015/07/31 REV:4 Output Voltage VDC 3.3 5 9 12 15 ±5 ±9 ±12 ±15 15 -9 3.3 5 9 12 15 ±5 ±9 ±12 ±15 15 -9 3.3 5 9 12 15 ±5 ±9 ±12 ±15 15 -9 3.3 5 9 12 15 ±5 ±9 ±12 ±15 15 -9 Output Current Max. mA 303 200 111 84 66 ±100 ±56 ±42 ±33 +33 -55 303 200 111 84 66 ±100 ±56 ±42 ±33 +33 -55 303 200 111 84 66 ±100 ±56 ±42 ±33 +33 -55 303 200 111 84 66 ±100 ±56 ±42 ±33 +33 -55 Tel:886-6-2923150 Page 1 of 4 Input Current @Max. Load mA(typ.) 286 286 266 261 254 282 269 262 254 @No Load mA(typ.) 35 Load Regulation Max. capacitive Load % (max.) 20 15 10 10 10 15 10 10 10 μF 1000 470 470 220 220 220# 220# 100# 100# 100 220 1000 470 470 220 220 220# 220# 100# 100# 100 220 1000 470 470 220 220 220# 220# 100# 100# 100 220 1000 470 470 220 220 220# 220# 100# 100# 100 220 # For each output 260 10 117 117 110 108 104 116 111 108 104 20 15 10 10 10 15 10 10 10 17 107 10 95 95 89 90 84 94 90 86 84 20 15 10 10 10 15 10 10 10 16 87 10 60 60 56 53 52 59 56 55 53 20 15 10 10 10 15 10 10 10 55 12 10 Efficiency (typ.) @Max. Load % 70 70 75 77 78 71 75 77 78 76 71 71 76 78 79 72 76 78 79 77 70 70 75 75 79 71 75 78 79 76 70 70 75 78 80 71 75 77 78 75 MA01-HI SERIES DC/DC CONVERTER 1W, High Isolation,SIP-Package Input Specifications Parameter Input Surge Voltage (1 sec. max.) Input Voltage Range Input Filter Model 5V Input Models 12V Input Models 15V Input Models 24V Input Models 5V Input Models 12V Input Models 15V Input Models 24V Input Models All Models Min. -0.7 -0.7 -0.7 -0.7 4.5 10.8 13.5 21.6 Conditions Min. ------- Typ. Max. 9 --18 --20 --30 --5 5.5 12 13.2 15 16.5 24 26.4 Internal Capacitor Unit VDC Output Specifications Parameter Output Voltage Setting Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise Temperature Coefficient Short Circuit Protection Typ. Max. --±5.0 Dual Output, Balanced Loads ±0.1 ±1.0 For Vin Change of 1% ±1.2 --Io=20% to 100% See Model Selection Guide 0-20MHz Bandwidth ----100 --±0.01 ±0.02 Continuous, Automatic Recovery Unit %Vnom. % % mV P-P %/℃ General Specifications Parameter Conditions Rated for 60 seconds Tested for 1 second 500 VDC 100KHz, 1V Typ. Max. ------------7 ------100 --MIL-HDBK-217F@25℃, Ground Benign 2,000,000 UL/cUL 60950-1 recognition (CSA certificate), IEC/EN 60950-1(CB-report) I/O Isolation Voltage I/O Isolation Resistance I/O Isolation Capacitance Common Mode Transient Immunity Switching Frequency MTBF (calculated) Safety Approvals Min. 5200 5700 10 --15 --- Unit VDC VDC GΩ pF KV/μs KHz Hours Environmental Specifications Parameter Operating Ambient Temperature Range (See Power Derating Curve) Case Temperature Storage Temperature Range Humidity (non condensing) Cooling Lead Temperature (1.5mm from case for 10Sec.) Conditions Min. Max. Unit Natural Convection -40 +85 ℃ +100 +125 95 ℃ ℃ % rel. H 260 ℃ ---55 --Natural Convection --- Power Derating Curve Output Power (%) 100 80 Natural Convection 20LFM 60 400LFM 40 20 0 ~ -40 50 60 70 80 Ambient Temperature C E-mail:[email protected] 2015/07/31 REV:4 Tel:886-6-2923150 Page 2 of 4 90 100 110 MA01-HI SERIES DC/DC CONVERTER 1W, High Isolation,SIP-Package Notes 1 2 3 4 5 6 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these modules; however they may not meet all specifications listed. We recommend to protect the converter by a slow blow fuse in the input supply line. Other input and output voltage may be available, please contact factory. That “natural convection” is about 20LFM but is not equal to still air (0 LFM). Specifications are subject to change without notice. Package Specifications Mechanical Dimensions Pin Connections 0.5 [0.02] 10.2 [0.40] 3.2 [0.13] 0.5 [0.02] 19.5 [0.77] 2.54 [0.10] 7.62 [0.30] Pin Single Output Dual Output 1 +Vin +Vin 2 -Vin -Vin 5 -Vout -Vout 6 No Pin Common 7 +Vout +Vout 2X2.54 2X[0.10] 7.1 [0.28] 18.5 [0.73] Bottom View 6 7 0.50 [0.02] 2.0 [0.08] 5 0.25 [0.01] 2 1 Physical Characteristics Case Size : 19.5x7.1x10.2mm (0.77x0.28x0.40 inches) Case Material : Non-Conductive Black Plastic (flammability to UL 94V-0 rated) Pin Material : Alloy 42 Weight : 2.4g E-mail:[email protected] 2015/07/31 REV:4 Tel:886-6-2923150 Page 3 of 4 ►All dimensions in mm (inches) ►Tolerance: X.X±0.5 (X.XX±0.02) X.XX±0.25 ( X.XXX±0.01) ►Pins ±0.05(±0.002) MA01-HI SERIES DC/DC CONVERTER 1W, High Isolation,SIP-Package Test Setup Peak-to-Peak Output Noise Measurement Test Use a Cout 0.33μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Vin +Out Copper Strip Single Output DC / DC Converter -Vin Cout -Out Scope Resistive Load Copper Strip +Vin +Out Copper Strip Dual Output DC / DC Converter Com. Copper Strip -Vin -Out Scope Cout Resistive Load Cout Scope Copper Strip Technical Notes Maximum Capacitive Load The MA01-HI series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 KHz) capacitor of a 2.2μF for the 5V input devices, a 1.0μF for the 12V,15V input devices and a 0.47μF for the 24V devices. + DC Power Source +Vin + +Out DC / DC Converter Load Cin - -Vin -Out Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 1.0μF capacitors at the output. + +Vin DC Power Source - + DC Power Source - +Out Single Output DC / DC Converter -Vin + Cout Load - + Out + Vin Dual Output DC / DC Com. Converter Cout1 Load1 - Vin Cout2 Load2 +Out Dual Output DC / DC Com. Converter DC Power Source -Out - Out +Vin -Vin -Out Cout Load Load Cout Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 100℃. The derating curves are determined from measurements obtained in a test setup. Position of air velocity probe and thermocouple 15mm / 0.6in 50mm / 2in Air Flow DUT 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected] Minmax Technology Co., Ltd. 2015/07/31 REV:4 Page 4 of 4