Test Name
Total Units Total Device
Tested
Hours
Conditions
High Temperature TA = 85 °C, IF = 12.6mA
Operating Life
VF(AVG) = 1.92 V
185
Failures1
572,913
10
Predicted Failure Rate at If = 7.0 mA (typical)
Predicted Performance
60% Confidence
MTTF
FIT
Predicted Performance
90% Confidence
MTTF
FIT
Ambient
Temp.
MTTF2
FIT3
(°C)
(Hours)
(109 Hours)
(Hours)
(109 Hours)
(Hours)
(109 Hours)
70
469,180
2,131
407,451
2,454
304,563
3,283
60
910,459
1,098
790,672
1,265
591,015
1,692
50
1,838,090
544
1,596,257
626
1,193,178
838
40
3,874,759
258
3,364,967
297
2,515,261
398
30
8,564,092
117
7,437,336
134
5,559,294
180
25
12,978,687
77
11,271,113
89
8,424,983
119
Notes:
1. End point failure criteria is a catastrophic failure or when the product demonstrates a drop in optical power of greater than 2 dBm at IF =
12mA.
2. MTTF is the total devices hours divided by either the number of failures or unity if there are no failures.
3. Failure in time (FIT) is equal to the number of failures expected in one billion device hours. For example, 1 FIT = 1 failure per
1,000,000,000 devices hours.
Optek reserves the right to make changes at any time in order to improve design and to supply the best product possible.
OPTEK Technology Inc.— 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (800) 341-4747 FAX: (972) 323– 2396 [email protected] www.optekinc.com
A subsidiary of
TT electronics plc
Issue 3.0
03.04
Application Bulletin 224
OPV300 Series VCSEL Reliability Data
OPV300 Series
Mechanical and Environmental Tests
Examination or Test
MIL-STD-883 (Unless otherwise stated)
Method
Details
11 Parts
Group 1
Mechanical Shock
2002
1,500 G at 0.5ms, 5 times per axis
Vibration
2007
Condition A
20-2,000 Hz, 4 min/cycle, 4 cycles/axis
Results
LTPD Reject Pass
20
End point testing for Group 1
11 Parts
Group 2
Thermal Shock
1011
0-100 °C
Solderability
2003
Steam aging not required
10 parts
Accelerated Aging Life Test
(Central Office Rating)
Output power maintained at 1.1mW. TC = 70°C
(TA may be adjusted to obtain TC value.
End point testing for Group 3
5,000 Hour read point
Group 4
25 parts
Accelerated Aging Life Test
(Uncontrolled Env. Rating)
Biased at rated power. TC = 85°C , 0.8mW
End point testing for Group 4
5,000 Hour read point
Group 5
11 Parts
High Temp Storage
1008
11
0
11
0
10
0
25
20
End point testing for Group 2
Group 3
0
20
TA = 125°C (2,000 hours total)
Mid point testing for Group 5
1,000 Hours
0
11
End point testing for Group 5
2,000 Hours
0
11
Group 6
11 Parts
Low Temp Storage
TA = -40°C (2,000 hours total)
Mid point testing for Group 6
1,000 hour mid point
0
11
End point testing for Group 6
2,000 hour end point
0
11
OPTEK Technology Inc.— 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (800) 341-4747 FAX: (972) 323– 2396 [email protected] www.optekinc.com
20
Issue 3.0
03.04
Page 2 of 3
Application Bulletin 224
OPV300 Series VCSEL Reliability Data
Examination or Test
MIL-STD-883 (Unless otherwise stated)
Method
11 Parts
Group 7
Temperature Cycling
(Central office rating)
Details
1011
Results
LTPD Reject Pass
20
-40 - 70 °C, 500 cycles
End point testing for Group 7
11 Parts
Group 8
Temperature Cycling
(Uncontrolled Env. Rating)
1010
5,000 Hour read point
Group 9
11 Parts
103
11 Parts
Moisture Resistance
20 cycles with 10 sub-cycles
0
11
0
11
0
5
20
20
End point testing for Group 10
5 Parts
1004
11
MIL-STD-202
85°C/85% Relative Humidity; 1,000 hours
Group 10
Water Vapor Content
0
20
End point testing for Group 9
Group 11
11
-40 - 85 °C, 500 cycles
End point testing for Group 8
Damp Heat
0
-
5,000 PPM Max H2O
End point testing for Group 11
OPTEK Technology Inc.— 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (800) 341-4747 FAX: (972) 323– 2396 [email protected] www.optekinc.com