ETC HSMS-8101

Surface Mount Schottky Diodes
Reliability Data
HSMS-8101
HSMS-820X
HSMS-286A/6X
The following cumulative test
results have been obtained from
testing performed at HewlettPackard Communications Components Division in accordance
with the latest revision of
MIL-STD-750. Data was gathered
and/or mechanical specification
listed in the Hewlett-Packard
Communications Components
Designer’s Catalog.
from the product qualification,
reliability monitor, and
engineering evaluation.
For the purpose of this reliability
data sheet, a failure is any part
which fails to meet the electrical
1. Life Test
A. Demonstrated Performance
Test
Test Conditions
Units
Tested
Total
Device Hrs.
Total
Failed
Failure Rate
1%/1K Hrs.
High Temp. Rev.
Bias (HTRB)
VR = 80% VBR, TA = 150°C
127
127,000
0
0
High Temp.
Operating
Life (HTOL)
Pfm = 75 mW, TA = 65°C
VR = 80% VBR
129
129,000
0
0
High Temp.
Storage (HTS)
TA = 150°C
129
129,000
0
0
B. Failure Rate Prediction
The failure rate will depend on the
junction temperature of the
device. The estimated life at
different temperatures is calculated, using the Arrhenius plot
with activation energy of 1.05 eV,
and listed in the following table.
Point[1]
90% Confidence Level[2]
Junction
Temp.
TJ (°C)
MTTF
(Hours)
FIT[3]
MTTF
(Hours)
150
140
130
120
100
75
50
3.6 x 106
7.3 x 106
1.5 x 107
3.2 x 107
1.7 x 108
1.8 x 109
2.6 x 1010
278.0
137.0
67.0
31.0
6.0
0.56
0.04
1.6 x 106
3.2 x 106
6.5 x 106
1.4 x 107
7.4 x 107
7.8 x 108
1.1 x 1010
FIT[3]
625.0
312.0
153.0
71.0
14.0
1.3
0.09
2
400
350
4.0
3.0
300
JUNCTION TEMPERATURE, Tj (°C)
1.5
200
1.0
150
Ea = 1.05 eV
0.9
0.8
100
ACTIVATION ENERGY (eV)
2.0
250
0.7
0.6
50
25
10 2
10 3
10 4
10 5
10 6
10 7
10 8
10 9
0.5
MEAN TIME TO FAILURE, MTTF (HRS)
Notes:
1. The point MTTF is simply the total
device hours divided by the number of
failures.
2. The MTTF and failure rate represent the
performance level for which there is a
90% probability of the device doing
better than the stated value. The
confidence level is based on the
statistics of failure distribution. The
assumed distribution is exponential.
This particular distribution is commonly
used in describing useful life failures.
3. FIT is defined as Failure in Time, or
specifically, failures per billion hours.
The relationship between MTTF and FIT
is as follows: FIT = 109/(MTTF).
C. Example of Failure Rate Calculation
At 50°C with a device operating 8 hours a day, 5 days a week, the percent utilization is:
% Utilization = (8 hrs/day x 5 days/wk) ÷ 168 hrs/wk = 25%
Then the point failure rate per year is:
(4.0 x 10-11/1000 hrs.) x (25%) x (8760 hrs/yr) = 8.76 x 10-6% per year
Likewise, the 90% confidence level failure rate per year is:
(9.0 x 10-11/1000 hrs.) x (25%) x (8760 hrs/yr) = 1.97 x 10-5% per year
3
2. Environmental and Mechanical Tests
Test
MIL-STD-750
Reference
Test Conditions
Units
Tested
Total
Failed
Solderability
2026
215°C, 5 seconds
500
0
Solder Heat
2031
260°C, 10 seconds
426
0
Resistance to Solvent
1022
4 solvent groups
98
0
Autoclave
121°C, 15 PSIG, 96 hrs.
116
0
Moisture Resistance
85°C/85% RH, biased, 1000 hrs.
118
0
Thermal Shock
1056
-65/150°C, 5 min dwell,
200 cycles
163
0
Temperature Cycle
1051
-65/150°C, 10 min dwell,
200 cycles
169
0
140
0
Lead Integrity
3. Flammability Test:
Meets Needle Flame Test Category D (Flaming Time <3 sec.) under
material classification 94V0.
4. DOD-HDBK-1686A ESD Classification:
HSMS-8101/820X/286X/286A
Class I
www.hp.com/go/rf
For technical assistance or the location of
your nearest Hewlett-Packard sales
office, distributor or representative call:
Americas/Canada: 1-800-235-0312 or
408-654-8675
Far East/Australasia: Call your local HP
sales office.
Japan: (81 3) 3335-8152
Europe: Call your local HP sales office.
Data subject to change.
Copyright © 1998 Hewlett-Packard Co.
Obsoletes 5965-9142E
Printed in U.S.A.