Detailed Drawing - Power Dynamics, Inc.

PC Series
CHASSIS MOUNT, SINGLE AND DOUBLE STAGE EMI/RFI LINE FILTER.
MECHANICAL DIMENSIONS (Unit: mm)
0.8 TYP.
+
70.5 - 1.0
50.0
+
28.5 - 0.5
FEATURES
The PC series offers superior performance in suppressing
Line-to-Line and Line-to-Ground noise. Designed for easy
mounting, this low profile Chassis mount filter is PDI’s most
popular filter offering current ratings up to 20 Amps at
250VAC. One size package offers both single and double
stage filtering.
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
3.5x2.0 TYP.
2x 5.00
L'
L
60.0
6.35 TYP. G
N
N'
TECHNICAL DATA
•
•
•
•
•
Rated Voltage: 250VAC
Rated Current: 1A, 3A, 5A, 6A, 10A, 15A, 20A
Power Line Frequency: 60Hz
Leakage Current: 0.8mA, 250VAC
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
• Temperature Range: -25C to +85C
70.7 MAX.
Specifications subject to change without notice. Dimensions (mm).
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com
25
PC Series Example & Ordering Code
PC 05
CURRENT RATING (A):
=
=
=
=
=
=
=
TERMINAL:
Q - 1
01✢
03✢
05✖
06✢
10✝
15✖
20✖
QUICK CONNECT
SCHEMATIC:
=Q
ONE STAGE
=1
TWO STAGE
=2
PC Series Attenuation Tables
Non-Medical Applications
Insertion loss in dB (50 Ohm circuit)
TWO STAGE
ONE STAGE
Current
Rating
Inductance
in mH
5A
10A
15A
20A
1.7
1.2
0.9
0.5
Comm. Mode(L-G) MHz
Diff. mode(L-L) MHz
.15 .5 1 5 10 30 .15 .5 1 5 10 30
17
16
14
7
27
24
19
17
31
28
22
22
42
34
32
32
46
36
33
34
42
40
41
50
7
9
10
7
37
36
32
27
37
35
28
28
46
40
37
36
42
42
38
39
37
38
40
46
Current
Rating
Inductance
in mH
1A
3A
6A
10A
3.7
1.8
0.7
0.3
Comm. Mode(L-G) MHz
Diff. mode(L-L) MHz
.15 .5 1 5 10 30 .15 .5 1 5 10 30
46
38
21
4
74
68
51
32
73
80
62
50
58
58
66
66
51
53
69
58
27
48
51
48
7
5
15
6
52
53
30
18
46
62
75
54
54
51
55
55
47
44
49
48
32
38
41
41
SCHEMATICS
G
10M
N
Cx
0.1 F
x2
Cx
Cy
2200pF
x2
L'
LOAD
LINE
L
N'
L mH
L
G
N
Cy
3300pF
x2
Cx
0.3 F
x3
L mH
L mH
L mH
L'
10M
Cx
LOAD
TWO STAGE
L mH
LINE
ONE STAGE
Cx
N'
L mH
Single stage only
Double stage only
✝
Available in single & double stage
✖
✢
26
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com