60320 INLET SOCKET WITH SWITCH, VOLTAGE SELECT AND A FUSE HGN-339 IEC HOLDER, SNAP-IN MOUNT MECHANICAL DIMENSIONS (Unit: mm) 52.0 110 40.0 220 36.0 FEATURES The HGN-339 incorporates features such as 2-pole on/off switch, IEC Connector, a fuse holder that accepts European 5 x 20mm or N. American 1/4” x 1 1/4” (3AG) fuse, and a voltage selector (110V/220V). It is designed for use in equipment intended for export enabling the fast change to other voltages. These filters are also available for Medical equipment with low leakage current to comply with UL 544 & UL2601. 0.8 TYP. 3.0 49.0 ** A+0.2 APPLICATIONS Computer & networking equipment, Measuring & control equipment, Data processing equipment, laboratory instruments, Switching power supplies, other electronic equipment. 55.0 TECHNICAL DATA • • • • Rated Voltage: 125/250VAC Rated Current: 1A, 2A, 3A, 4A, 6A Power Line Frequency: 50/60Hz Max. Leakage Current each Line to Ground: @ 250VAC 50Hz: 0.5mA, max @ 250VAC 50Hz: 2µA*, max • Hipot Rating (one minute) Line to Ground: 2250VDC Line to Line: 1450VDC • Temperature Range: -25C to +85C 6.3 TYP. 49.5 +0.2 4X R1.5 36.5+0.2 * Medical application RECOMMENDED PANEL CUTOUT Specifications subject to change without notice. Dimensions (mm). See Appendix A for recommended power cord. See PDI full line catalog for detailed specifications on power cords. 64 145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076 e-mail: [email protected] • www.powerdynamics.com HGN-339 Series Example & Ordering Code HGN-339 - 1 = = = = = CURRENT RATING (A): SCHEMATIC: M - - 150 1 2 3 4 6 STANDARD TYPE = WITHOUT C(Y); C(X) ONLY =M TERMINAL: F BLANK QUICK CONNECT (6.3 x 0.8) PANEL THICKNESS*: =F = 150 = 160 = 200 0.06 (1.5MM) 0.062 (1.6MM) 0.08 (2.0MM) * More panel thickness options are available upon request Attenuation Tables & Schematics Non-Medical Applications Insertion loss in dB (50 Ohm circuit) P Fuse E' 2200pF Fuse L(mH) N' 2200pF 220V 110V LOAD 0.033 F E 1M 55 60 60 64 60 L(mH) N 30 0.033 F 1A 2A 3A 4A 6A L Comm. Mode(L-G) MHz Diff. mode(L-L) MHz Value .01 .05 .15 .5 1 5 10 30 .01.05 .15 .5 1 5 10 10.3mA 19 34 42 53 57 50 55 55 15 5 5 33 47 71 70 4.6mA 6 18 26 37 44 54 51 60 23 8 10 20 33 68 70 2.5mA 12 18 25 37 45 53 65 60 16 5 10 24 35 64 65 1.2mA 6 16 23 34 40 54 56 65 11 4 4 20 33 63 66 0.8mA 6 15 21 30 35 50 55 60 16 6 6 15 28 60 65 LINE Current Rating P' Medical Applications Insertion loss in dB (50 Ohm circuit) 32 30 28 18 13 41 38 33 23 19 51 40 38 30 27 48 42 38 32 29 37 36 30 32 29 31 30 23 30 29 22 21 18 22 25 9 9 9 9 9 11 11 15 13 18 15 11 14 19 21 50 42 38 19 19 67 67 55 44 47 82 82 82 82 84 71 75 76 79 82 37 38 35 40 50 E P 145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076 e-mail: [email protected] • www.powerdynamics.com L(mH) N' E' 220V Fuse LOAD 22 18 18 10 8 Fuse 0.033 F 10.3mA 4.6mA 2.5mA 1.2mA 0.8mA L(mH) N 1M 1A 2A 3A 4A 6A Comm. Mode(L-G) MHz Diff. mode(L-L) MHz .01 .05 .15 .5 1 5 10 30 .01.05 .15 .5 1 5 10 30 0.033 F L Value LINE Current Rating 110V P' 65