PD Series CHASSIS MOUNT, SINGLE AND DOUBLE STAGE EMI/RFI LINE FILTER. MECHANICAL DIMENSIONS (Unit: mm) 2X 5.00 L M4 THREAD TYP. L' G 60.0 N N' 85.3 MAX. FEATURES The PD series offers single and double stage filters in the same package particularly for high impedance loads. Designed for easy mounting, this low profile chassis mount filter offers current ratings up to 20 Amps at 250VAC. One size package offers both single and double stage filtering. (See PC series for Quick Connect Terminals) APPLICATIONS Computer & networking equipment, Measuring & control equipment, Data processing equipment, laboratory instruments, Switching power supplies, other electronic equipment. + 70.5 - 1.0 50.0 TECHNICAL DATA • • • • • Rated Voltage: 250VAC Rated Current: 1A, 3A, 5A, 6A, 10A, 15A, 20A Power Line Frequency: 60Hz Leakage Current: 0.8mA, 250VAC Hipot Rating (one minute) Line to Ground: 2250VDC Line to Line: 1450VDC • Temperature Range: -25C to +85C 28.5+- 0.5 Specifications subject to change without notice. Dimensions (mm). 145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076 e-mail: [email protected] • www.powerdynamics.com 29 PD Series Example & Ordering Code PD 05 CURRENT RATING (A): = = = = = = = TERMINAL: PS - 1 01✢ 03✢ 05✖ 06✢ 10✝ 15✖ 20✖ = PS SCREW SCHEMATIC: (ONE STAGE) =1 (TWO STAGE) =2 PD Series Attenuation Tables Non-Medical Applications Insertion loss in dB (50 Ohm circuit) ONE STAGE Current Rating Inductance in mH 5A 10A 15A 20A 1.7 1.2 0.9 0.5 TWO STAGE Comm. Mode(L-G) MHz Diff. mode(L-L) MHz .15 .5 1 5 10 30 .15 .5 1 5 10 30 17 16 14 7 27 24 19 17 31 28 22 22 42 34 32 32 46 36 33 34 42 40 41 50 7 9 10 7 37 36 32 27 37 35 28 28 46 40 37 36 42 42 38 39 37 38 40 46 Current Rating Inductance in mH 1A 3A 6A 10A 3.7 1.8 0.7 0.3 Comm. Mode(L-G) MHz Diff. mode(L-L) MHz .15 .5 1 5 10 30 .15 .5 1 5 10 30 46 38 21 4 74 68 51 32 73 80 62 50 58 58 66 66 51 53 69 58 27 48 51 48 7 5 15 6 52 53 30 18 46 62 75 54 54 51 55 55 47 44 49 48 32 38 41 41 SCHEMATICS N Cx Cy 2200pF x2 L L' N' L mH G N Cy 3300pF x2 Cx 0.3 F x3 L mH L mH L mH L' 10M Cx LOAD 10M Cx 0.1 F x2 LOAD LINE L G TWO STAGE L mH LINE ONE STAGE Cx N' L mH Single stage only Double stage only ✝ Available in single & double stage ✖ ✢ 30 145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076 e-mail: [email protected] • www.powerdynamics.com