POWERDYNAMICS HGN-337

HGN-337 IEC 60320 INLET SOCKET WITH SWITCH AND A FUSE HOLDER,
SNAP-IN MOUNT
MECHANICAL DIMENSIONS (Unit: mm)
52.0
Use only with a 250V fuse
40.0
0.80 TYP.
36.0
FEATURES
The HGN-337 power entry module feature a combination
IEC Connector, two pole on/off switch and fuse holder that
accepts both European 5 x 20mm or N. American
1/4” x 1 1/4” (3AG) fuse. The HGN-337 protects electronic
equipment from common-mode and differential-mode
interferences.
6.3 TYP.
These filters are also available for Medical equipment with
low leakage current to comply with UL 544 & UL2601.
APPLICATIONS
55.0
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
A+0.2
TECHNICAL DATA
• Rated Voltage: 125/250VAC
• Rated Current: 1A, 2A, 3A, 4A, 6A,
• Power Line Frequency: 50/60Hz
• Max. Leakage Current each
Line to Ground:
@ 250VAC 50Hz: 0.5mA, max
@ 250VAC 50Hz: 2µA*, max
• Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
• Temperature Range: -25C to +85C
3.00
49.0
49.5 +0.2
4X R1.5
36.5 +0.2
* Medical application
RECOMMENDED
PANEL CUTOUT
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
62
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com
HGN-337 Series Example & Ordering Code
HGN-337 - 1
=
=
=
=
=
CURRENT RATING (A):
SCHEMATIC:
M -
F
- 150
1
2
3
4
6
STANDARD TYPE
=
WITHOUT C(Y); C(X) ONLY
=M
BLANK
TERMINAL:
=F
QUICK CONNECT (6.3 x 0.8)
PANEL THICKNESS*:
0.06 (1.5MM)
0.062 (1.6MM)
0.08 (2.0MM)
= 150
= 160
= 200
* More panel thickness options are available upon request
Attenuation Tables & Schematics
Non-Medical Applications
Insertion loss in dB (50 Ohm circuit)
P
N'
2200pF
E'
2200pF
L(mH)
Fuse
L(mH)
Fuse
LOAD
Fuse
0.033 F
E
0.033 F
30
30
34
32
35
1M
30
L(mH)
N
LINE
Current
L
Comm. Mode(L-G) MHz
Diff. mode(L-L) MHz
Rating Value .01 .05 .15 .5 1 5 10 30 .01.05 .15 .5 1 5 10
1A 10.3mA 18 30 40 57 50 50 64 29
9 13 13 45 65 70 60
2A
4.6mA 11 25 35 49 49 70 60 30 10 14 16 40 60 70 60
3A
2.5mA 5 20 30 41 48 54 60 34 10 14 18 30 55 70 61
4A
1.2mA 5 12 21 35 40 50 70 32
9 14 19 20 45 70 60
6A
0.8mA 2 10 20 30 34 45 55 35
9 14 19 19 40 70 60
P'
-
Medical Applications
Insertion loss in dB (50 Ohm circuit)
32
30
28
18
13
41
38
33
23
19
51
40
38
30
27
48
42
38
32
29
37
36
30
32
29
31
30
23
30
29
22
21
18
22
25
9
9
9
9
9
11
11
15
13
18
15
11
14
19
21
50
42
38
19
19
67
67
55
44
47
82
82
82
82
84
71
75
76
79
82
37
38
35
40
50
E
P
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: [email protected] • www.powerdynamics.com
L(mH)
N'
E'
Fuse
LOAD
22
18
18
10
8
0.033 F
10.3mA
4.6mA
2.5mA
1.2mA
0.8mA
N
0.033 F
1A
2A
3A
4A
6A
Comm. Mode(L-G) MHz
Diff. mode(L-L) MHz
.01 .05 .15 .5 1 5 10 30 .01.05 .15 .5 1 5 10 30
1M
L
Value
LINE
Current
Rating
P'
63