Space Products

Space Products
Semelab products and processes for space applications
SEMELAB | experience and innovation
2
Contents
1. Introduction
.......................................................................................................................
4
2. Programmes Supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3. Innovations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
3.1 Improving the Space Weather Forecast with the LCC1- 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
3.2 SoLaRfets – Radiation Tolerant MosFETS
.....................................................................
7
3.3 Si3N4 via technology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
3.4 Wide-Bandgap devices
.................................................................................................
8
3.5 Diode – Leadless Chip Carriers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
3.6 Diamond Substrate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
4. Hi-Rel COTS – Commercial Considerations
5. Product Range
..................................................................
10
.................................................................................................................
11
6. Package Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
The following sections are extracted from Semelab document ‘High Reliability
and Screening Applications’ available at www.semelab.com/sml_downloads.
9. MIL-PRF-19500 - QR216, QR217 (Space)
......................................................................
17
9.1 Space Level Processed Discrete Semiconductors (QR216, QR217) . . . . . . . . . . . . . . . . . . . . . . . . . . .17
9.2 QR217 - Inspection levels:‘Space Level Processed’ Conformance
18
............................
9.3 QR216 - Screening: Space Level Processed’ Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
10. ESA - ESCC (Space)
..........................................................................................................
10.1 Chart F2 - Production Control
10.2 Chart F3 - Screening Tests
21
.................................................................................
22
.......................................................................................
23
10.3 Chart F4 - Qualification and Periodic Tests
11. Screening & Approval Comparison Tables
24
.............................................................
..................................................................
25
11.1 Comparison of Space Level Screening Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
11.2 Comparison of Space Level Die Lot Approval Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
11.3 Comparison of High-Rel Screening Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Issue 2 - (DMD) - 05/08
3
1. Introduction
Experience and Innovation In Semiconductor Technology
At SEMELAB, we research, design, manufacture and distribute
an innovative range of semiconductor products throughout
the world.
Our R&D teams have an excellent track record for developing
imaginative electronic solutions and our design engineers
have created a wealth of high performance products.
Our manufacturing divisions have ensured supreme quality
and reliability. And our sales teams and distribution partners
have opened international markets to some of the best
electronics solutions available.
Semelab has many years experience of the design and
manufacture of supplying semiconductor solutions for use in
space applications. All design and manufacturing is carried
out in Semelab’s UK custom built facility.
There are a wide range of discrete semiconductors available:
Bipolar, SoLaRfets, MOSfets, Jfets, Linear Regulators and Diodes.
These are available in many different package options: small
ceramic surface mount; multi pad ceramic surface mount;
power ceramic, metal hermetic packages. Details of the different
package outlines and range of products are included in the
following pages.
Also available are a range of standard and custom MCAs (Multi Chip Arrays). These integrate several
semiconductor die or other components into one package to provide a light weight, space saving
and improved-reliability alternative to discrete circuits. There are a range of package styles available
for small signal and power applications. These are cost effective solutions with little or no NRE and
similar lead times to standard discrete products. The different package styles are included in the
following pages.
Example circuit based on Semelab MCAs (picture courtesy of Comdev)
4
2. Programmes Supported
Over recent years many different Semelab products have been used in major Space programs
including the following:
ENVISAT
LCC1, Small Signal
IMMARSAT
LCC1, Small Signal, TO18, High Speed Zener, Schottky Diode
EMS
LCC1 Small Signal
ASTRA
LCC1, LCC2, Small Signal (dual)
SOHO CLUSTER
J-Fets
FIAR
TO59 – Biploar power
KOREA SAT
LCC1, Small Signal, J-fets, Zener, Schottky Diodes
SPOT / HELIOS
LCC1, Small Signal, J-fets, Diodes
SKYNET
TO18 / TO39 – Small Signal
ARTEMIS
LCC1, LCC2, LCC4
ODYSSEY
MCAs
MIMR
MCAs
GLOBAL STAR
MCAs - Analogue Arrays
MSG
MCAs
METOP
MCAs, Linear Regulators
ROSETTA
Small Signal LCC1
ATV
T018 / 39
ISS
Bipolar TO39 /TO66 , MCAs
SMART 1
Digital voter circuit, Dual Bipolar, LCC2
RAINBOW
MCA, Small Signal devices
SIRAL
Small Signal - JFET, LCC1
GALILEO
MCA, Small Signal devices
ARRIANE VEGA
Power Module
ALTIKA
SoLaRfet©, MCA
SKYNET
MCA, Small Signal devices
SENTINEL
MCA, LCC1, SoLaRfet© (Power MOSfets), Small Signal devices
BEPI-COLUMBO
LCC1, Small Signal device
5
3. Innovations
Semelab has always been at the forefront of innovation. For many years our R&D teams have been
coming up with imaginative electronic and packaging solutions. Over the years many of these solutions have become incorporated into our standard range of products with a wide and extensive
range of applications. This section gives details of some of our recent developments
3.1 Improving the Space Weather Forecast with the LCC1- 4
As spacecraft navigate the oceans of space, satellites encounter
severe storms in a ‘similar’ way as Earth based ocean going
vessels do.
A documented phenomenon known as Deep Dielectric Discharge,
associates high speed solar wind streams with the appearance of
large numbers of highly energetic electrons in the magnetosphere.
These high energy electrons are dangerous to the operation of
the spacecraft as they bury themselves into dielectric materials
deep within the satellite, (materials such as PCB materials, coaxial
cables etc).
The build-up of charge occurs when the total amount of high velocity electrons exceed 1MeV (1
Million electron Volts) during the storm event. The charge continues to build-up until the dielectric
strength of the material is exceeded. Once this happens an instantaneous electrical discharge occurs,
which is similar to a miniature lightening strike. This is a hazardous event capable of damaging
semiconductor and other sensitive devices.
Part of the solution is to incorporate design improvements to mitigate the effects of Deep Dielectric
Discharge. Semelab are currently offering LCC1-4 (Leadless Chip Carrier Number 1, 4 pads), which is
based on the ESA qualified ceramic chip carrier technology, but has an additional feature which
electrically connects the metal lid of the discrete device, to an additional solder pad at the base of
the package, so the lid can be electrically connected to a known potential, (usually ground),
therefore conducting away the charge as it occurs.
Deep Dielectric Discharge: LCC1- 4 package
LCC1- 4 package – internal view
The full range of products that are available in the standard LCC1 package are also available in the
Deep Dielectric Discharge LCC1-4 package. Section 4 contains details of products supplied in the past.
Contact Semelab Sales for further information.
6
3.2 SoLaRfets
The Semelab SoLaRfet has been specifically developed to
provide a radiation tolerant MosFET for use in space applications.
The development is an extension of one of our existing MosFET
processes which has been sold in high volumes over many years.
The structure of the device has been modified to enhance the
DC performance and give good SEU characteristics. The device
is ideally suited for fast switching applications in harsh
environments.
Semelab have also made developments in the substrate and package technology to further optimise
the performance of finished devices. Contact Semelab sales for further information.
110
ION
LET
ENERGY
MeV
Argon
14.1
150
42
Krypton
34
316
43
Xenon
55.9
459
43
100
90
80
VDS (V)
70
60
RANGE
um Si
Ar = 14.1 MeV mg-1 cm2
Kr = 34.0 MeV mg-1 cm2
Xe = 55.9 MeV mg-1 cm2
50
40
30
20
Argon
Krypton
Xenon
10
0
0
2
4
6
8
10
12
14
16
18
20
22
-VGS (V)
Single Event Effect Safe Operating Area
Radiation Tolerant MOSFET bridge in Si3N4 package
3.3 Si3N4 Via Technology
Semelab have always been at the forefront of packaging technology, being the first to bring a
number of what have now become industry standard packages to the market place. Semelab
have also developed module packages (ie MCA, Power MCA and others) for combining a number
of different discrete devices and/or technologies in a range of hybrid solutions.
The benefits of Semelab’s modular solutions over discrete devices include: Higher density; Lighter
weight; Easier interconnection; Little or No NRE; Lower
cost; Fast turnaround & improved reliability.
This trend continues with the recently introduced Si3N4
via technology module. The package combines state-ofthe-art Via technology with Si3N4 substrates to achieve
high power performance without the use of glass seals.
The package is semi-customable to enable multi-chip
arrays based on circuit requirements.
Example of the semi-customable Si3N4
7
3.4 Wide-Bandgap devices
There has been much interest in Wide-bandgap semiconductor
materials in recent years.Their exceptional electronic and thermal
properties make them ideally suited to applications that
require high temperature performance in a harsh environment.
Semelab is the first European supplier to fully characterise
Silicon Carbide Diodes up to 225 C. (see Semelab data sheet
SML10SIC06-1NJC). The benefits of the technology can be
clearly seen.
Key benefits of Silicon Carbide diode include low on state
losses (due to low VF and positive temperature coefficient);
reduction in switching losses (due to Zero reverse recovery);
high frequency operation and high-temperature performance.
The combination of these benefits makes it possible to achieve higher performance in a smaller
space when compared with standard Silicon devices. An additional benefit in space applications is
the inherent rad-hardness of the device.
20
200
18
180
TJ = 25ºC
16
160
TJ = 75ºC
140
TJ = 175ºC
IR Reverse Current (A)
IF Forward Current (A)
TJ = 125ºC
14
TJ = 225ºC
12
120
10
100
8
6
TJ = 25ºC
TJ = 125ºC
60
TJ = 175ºC
TJ = 225ºC
4
40
2
20
0
TJ = 75ºC
80
0
0
10
20
30
0
100
VF Forward Voltage (V)
200
300
400
500
600
VR Reverse Voltage (V)
Fig 1. SML10SIC06-1NJC - VF performance
Fig 2. SML10SIC06-1NJC - Tr
Wide Bandgap device - Silicon Carbon Diode
8
700
800
900
3.5 Diode Leadless Chip Carriers (DLCC)
Semelab have been supplying a range of devices (bipolar, MOSFET and diodes) in in the popular
range of LCC (leadless chip carriers) packages for many years. A recent addition has been the
development of the DLCC, a surface mount package specifically designed for diodes to achieve
optimum performance and space utilization.
The package is an alternative to existing standard
packages currently available on the market. The first
two packages in this range are the DLCC1 and the DLCC2.
The DLCC1 and DLCC2 packages have been developed
to cover the wide range of Small Signal and Medium
Power Diode chip types which are used extensively in
existing and new designs.
Benefits of the packages include a grounded lid to address the problem associated with the ‘Deep
Dielectric Discharge’ phenomenon (see 3.1 - Improving the Space Weather Forecast with the LCC1- 4);
and castellated design to achieve better ‘meniscus witness’ for improved overall system reliability.
3.6 Diamond Substrates
Semelab have many years experience in the supply of RF MOSFETs. The devices are manufactured
using a unique silicon Vertical DMOS process with gold metalisation which gives high performance
and maximum reliability at high power levels.
The diamond substrate was originally developed for use in the RF product range to enhance the
performance and reliability of the device even further. Both simulations and measurements have
shown a considerable improvement in a number of areas. The most significant of these is the
halving in value of the junction to case thermal resistance when compared with the Beryllium
Oxide substrate normally used.
Please contact Semelab sales for further information on the use of diamond substrates in products
for space use and also for information on Hermetic RF products.
Enhanced performance RF device using diamond substrate
9
4. Hi-Rel ‘COTS’ – Commercial Considerations
For many years there has been talk of COTS (commercial-off-the-shelf ) products for space use. There
has been much confusion over what this means. At Semelab we have only ever believed in supplying
High-Reliability devices for use in space applications. However, there are a number of commercial
considerations which can be applied enabling High-Rel products to be supplied in shorter lead times
and at a lower overall contract cost.
Semelab works with it’s customers to supply the most appropriate commercial solutions for the contract requirements, ensuring best value and continuity of supply.
4.1 Space Kanban
Semelab can work with it’s customers to supply ‘kanban’ solutions to meet production requirements.
By placing a longer term contract, all wafer or die can be procured and reserved ensuring consistency
of product over the full production time frame. In addition a reduction of ancillary costs can be
achieved by single lot radiation testing and SEM’s; and a reduction of the additional costs such as
‘pre-cap visual inspections’ and ‘buy offs’ by producing larger batch quantities. Semelab will then
hold fully completed stock in it’s bonded stores against the customer contract, available for immediate
call off. Invoicing for the product will be at the time of shipping. Contact the Semelab Sales Office for
further information.
Benefits of Space Kanban include:
- single wafer lot production
- reduced ancillary costs
- scope for re-scheduling
- invoicing at point of shipping.
4.2 ‘Off-the Shelf’ Product
Semelab have a number of space products which are manufactured on a regular basis. The ongoing
production of these parts means that there is often stock available ‘off-the-shelf’ for immediate
delivery. These products are available processed to Semelab’s QR217 (Space Level Full Quality
Conformance Inspection and QR216 (‘Space Level Discrete Component Screening). See Section 9
for full details of QR217, QR216. (Please note that in addition, LVT’s are sometimes available on these
parts, but not always)
Parts Include:
2N2222, 2N2369, 2N2484, 2N2857, 2N2894, 2N2907
2N4391, 2N4392, 2N4393
4.3 Wafer & Die Storage
To ensure long term availability of product supply Semelab can
procure any volume of wafer or die on behalf of a customer. This will
then go through immediate qualification and be held in storage for the
sole use of that customer. This practice has been successfully employed
by Semelab for many years.
10
5. Product Range
Semelab have provided many products types in the past for space applications:
BIPOLAR:
2N2219A
2N2222A
2N2222ACSM
TO39
TO18
LCC1
2N2222ADCSM
LCC2
2N2369A
TO18
2N2369ACSM
LCC1
2N2369ADCSM
2N2484
2N2484CSM
2N2484DCSM
2N2857
LCC2
TO18
LCC1
LCC2
TO18
2N2857CSM
2N2880
2N2894
2N2894DCSM
2N2905A
2N2907A
2N2907ACSM
LCC1
TO59
TO18
LCC2
TO39
TO18
LCC1
2N2907ADCSM
LCC2
2N2908X
2N2920
2N2920A
2N2920ADCSM
2N3019
TO53
TO77
TO77
LCC2
TO39
2N3019CSM
LCC1
2N3439
2N3467
TO39
TO39
ESCC 5201 003 02C
ESCC 5201 002 01B (&C)
ESCC 5201-002-05C
66-LC-0147 O1B
TPR-12-034
MA500 AJB
STR01-020-01
66-LC0147 LVL C
SCC 5201 002 04B
STR01-031 01B
66-LC-0190 02B
ESCC 5201 006 05B
ESCC 5201 006 04B
RA.1201.009.10
RA.1201.017.10
TPR-12-032
66-LC-0173-01 LVL B
ESCC 5201 006 04B (&C)
ESCC 5201 006 05B
RA.1201.009.10
RA.1201.017.10
TRP-12-032
66-LC-0173 01 LVL B (&C)
MIL-PRF-19500/317 (QR216/7)
SCC 5201 001 01B (&C)
66-LC-0170 LVL B
66-LC-0171 LVL B
SC 5201 014 01B (&C)
66-LC-0168
66-LC 0176
ESCC 5203 025
ESCC 5201 014 01C
QR216 & QR217
ESCC 5202 002 02B (&C)
ESCC 5202 001 01B
ESCC 5202 001 04B (&C)
66 LCO145 LVL B (&C)
MA-5000-AJC
STR-021-01
TPR-12-030
RA.1202.008.11A
ESCC 5201 001
1000 017 576
66-LC0189 02B
STR01-032
IGG-290-874 01B
SCC 5207 002 02B (&02C)
SCC 5207 002 03B
SCC 5207 002 12B
SCC 5201 011 02C
SCC 5201 011 03B
STR01-019-02B
SCC 5201 011 02C
SCC 5201 011 03B
STR01-019-02B
ESCC 5203 011 02B
ESCC 5208 009 01
11
LCC1
LCC2
SMD1
TO257
TO18
TO39
2N3501
2N3637
2N3700CSM
2N3764
2N3765
2N3810
2N3810DCSM
2N3822
2N3906CSM
2N5153
2N5153SMD05
TO39
TO39
LCC1
TO18
TO46
TO77
LCC2
TO18
LCC1
TO39
SMD05
2N5153U
2N5154X
2N5154XSMD05
TO39
TO39
SMD05
2N5154XSMD1
2N5672
SMD1
TO3
2N5954
2N6849
2N918
BDS16
BDS18
BDS20
BUL54AH
BUL54A-T257
FMMT92CSM
TO66
TO39
TO72
TO257
TO257
TO257
TO5
TO257
LCC1
ESCC 5201 013 02B
ESCC 5208 003 03B (&4B)
ESCC 5201 004 04B
MA.500.ACK
IGG-221-724
ESCC 5207 005 02B (&1C)
66-LC0169
IGG-232-777-02
ESCC 5204 002 05B
ESCC 5204 002 02B (&03B)
SCC 5204 002 XX
MIL-PRF-19500/545D (QR216/7)
ESCC 5204 002 05B
ESCC 5203 010 04B
ESCC 5203 010 04B
QR217 GPS A,B,C + QR216
QR217 GPS A,B,C + QR216
SCC 5203 004 03B
66-LC0131
IGG-221-826-01
ESCC 5206 003 01C
ESCC 5201 009 01B
T-120-01B (&1C)
T-121-01B (&1C)
SAH 0046-G200-W2
RA.1203.004.10-11
RA.1203.003.10-12
RA.1202.006.11
LCC6
LCC6
LCC20
LCC20
LCC20
LCC20
LCC20
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC20
LCC6
LCC6
LCC6
MCA 0102 TC - CDP 9.19
MCA 0102 UC - CDP 9.19
MCA 0102 VC - CDP 9.19
MCA 0102 WC - CDP 9.19
MCA 0102 1C - CDP 9.19
MCA 0102 2C - CDP 9.19
MCA 0102 3C - CDP 9.19
SE5000 / MCA0301 -01
SE5000 / MCA0301 -02
SE5000 / MCA0301 -03
SE5000 / MCA0301 -04
SE5000 / MCA0301 -05
SE5000 / MCA0301 -06
SE5000 / MCA0301 -07
SE5000 / MCA0301 -08
SE5000 / MCA0301 -09
SE5000 / MCA0301 -10
SE5000 / MCA0301 -11
SE5000 / MCA0301 -12
SE5000 / MCA0301 -13
SE5000 / MCA0301 -14
SE5000 / MCA0301 -15
IGG-160-1474-02C
SCD 201366-1
SCD 201366-3
SCD 201366-5
LCC1
LCC2
SMD1
MCA’S
MCA0102/T
MCA0102/U
MCA0102/V
MCA0102/W
MCA0102/X
MCA0102/Y
MCA0102/Z
MCA0301/A2
MCA0301/B
MCA0301/C2
MCA0301/D
MCA0301/E
MCA0301/F
MCA0301/G
MCA0301/H
MCA0301/J
MCA0301/K
MCA0301/L
MCA0301/M
MCA0301/N
MCA0301/P
MCA0301/Q
MCA0401/1
MCA0616/1
MCA0616/2
MCA0616/3
12
LCC6
LCC20
MCA0625/1
MCA0625/2
MCA0625/3
MCA0625/4
MCA0627/1
MCA0627/3
MCA2696/1
MCA2696/2
MCA2696/3
MCA2696/4
MCA2696/5
MCA2696/A2
MCA2696/B
MCA2696/C2
MCA2696/D
MCA2696/E
MCA2696/F
MCA2696/G
MCA2696/H
MCA2696/J
MCA2696/L
MCA2703/1
MCA3201/1A
MCA3201/1B
MCA3201/2B
MCA3201/3A
MCA3201/3B
MCA3201/4B
MCA4003/1
MCA4003/2
MCA4003/3
MCA5001/5
LCC20
LCC20
LCC20
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC6
LCC16
LCC6
LCC6
LCC20
LCC6
LCC6
LCC20
LCC20
LCC6
LCC6
LCC6
SCD 201366-7
SCD 201366-9
SCD 201366-11
SCD 201366-13
SCD 201366-15
SCD 201366-17
RA.0812.002.11B
RA.0812.002.12B
RA.0812.002.13B
RA.0812.002.14B
RA.0812.002.15B
TL-AM-1201-16B
TL-AM-1201-17B
TL-AM-1201-18B
TL-AM-1201-19B
TL-AM-1201-20B
TL-AM-1201-21B
TL-AM-1201-22B
TL-AM-1201-23B
TL-AM-1201-24B
TL-AM-1201-25B
96-LC0071-01
CDP 9.90.01
CDP 9.90.02
CDP 9.90.04
CDP 9.90.05
CDP 9.90.06
CDP 9.90.07
SCD-200301-1
SCD-157592-3
SCD-157603-5
SCD 157592-1
1N4003Q
1N4148
LCC2
LCC1
1N4150
1N4151
1N4572
1N4626
1N5617
1N5711
45CKQ100
60CKQ045
BAS70
BAT54
LCC1
LCC1
LCC1
LCC1
LCC1
LCC1
TO258
TO258
LCC1
LCC1
BZX55C15
LCC1
BZX55C33
BZX55C3V3
LCC1
LCC1
BZX55C3V9
BZX55C5V6
LCC1
LCC1
65-LC-0124
65-LC-0119
SCD 157769
TPR-04-066
65-LC-0134-01
65-LC-0134-02
65-LC-0132-08
65-LC-0145-01
65-LC-0133
QR217 GPS A,B,C QR216
PO-PS-IGG-PL-0100
PO-PS-IGG-PL-0063
SCD 201444-01
65-LC0118
PO-PS-IGG-PL-0189
SCD 157558 (CDP926E O1)
65-LC-0120-20
TPR-04-059-20
65-LC0120-28
65-LC0120-04
TPR-04-059-04
65-LC-0120-06
65-LC-0120-10
LCC6
LCC20
DIODES
13
LCC1
LCC2
TO258
BZX55C7V5
HP5082-2800
HP5082-2810
MP2835
LCC1
LCC1
LCC1
LCC1
65-LC-0120-13
65-LC-0136-01 (&02)
65-LC-0135-01 (&02)
65-LC-0150
2N4391
TO18
2N4392
2N4392CSM
TO18
LCC1
2N4393
2N4393CSM
TO18
LCC1
2N4416
2N5116
TO72
TO18
ESCC 5205 003 01B (&01C)
MA 5000 AKW 01B
66-LC-0197
ESCC 5205 003 02B (&02C)
ESCC 5205 003 02B
RA.1205.071.10
TL-AM-023
30600050/022
ESCC 5205 003 03B (&03C)
65-LC-0153-01B 97
30600051/022
ESCC 5205 004 01B (&01C)
66-LC-0180-01
TO39
cer-dip
TO257
TO257
TO257
ESCC 5206 003 01B (&C)
INM-232-312
INM-232-313
IGG-232-394
INM-232-314
TO39
T257
LCC4
ESCC 9102 005 06B
44-LC-0152
TLAM 0814 03B
SML150FBH12ESA
custom
SML150HBH06ESA
custom
150A 1200V IGBT
Hermetic Module
150A 600V 3 phase
IGBT Bridge - Hermetic Module
LCC1
JFETS
LCC1
TO18
MOSFETS
2N6849
IRFG110
IRFY044
IRFY140
IRFY240
TO257
REGULATORS
LM117H
LM137
LM137
LCC4
MODULES
SoLaRfet
SFA001
custom
SML12SF24SMD
SMD1
Radiation Tolerant MOSFET
bridge in Si3N4 package
Radiation Tolerant FET
14
6. Package Drawings
0.31 rad.
(0.012)
2.54 ± 0.13
(0.10 ± 0.005)
0.76 ± 0.15
(0.03 ± 0.006)
2
1
1.91 ± 0.10
(0.075 ± 0.004)
3.05 ± 0.13
(0.12 ± 0.005)
A=
3
2
1
4
A
6
0.23 rad.
(0.009)
5
A
0.31 rad.
(0.012)
A = 1.27 ± 0.13
(0.05 ± 0.005)
6.22 ± 0.13
(0.245 ± 0.005)
1.40
(0.055)
max.
1.02 ± 0.10
(0.04 ± 0.004)
LCC1
1.40 ± 0.15
(0.055 ± 0.006)
1.65 ± 0.13
(0.065 ± 0.005)
4.32 ± 0.13
(0.170 ± 0.005)
2.29 ± 0.20
(0.09 ± 0.008)
3
0.64 ± 0.06
(0.025 ± 0.003)
2.54 ± 0.13
(0.10 ± 0.005)
0.51 ± 0.10
(0.02 ± 0.004)
LCC2
1.40 ± 0.15
(0.055 ± 0.006)
5.59 ± 0.13
(0.22 ± 0.005)
9.14 (0.360)
8.64 (0.340)
1.27 (0.050)
1.07 (0.040)
# 2.16 (0.085)
12 13 14 15 16
0.25 ± 0.03
(0.01 ± 0.001)
3
1.27 ± 0.05
(0.05 ± 0.002)
0.23 rad.
(0.009)
0.64 ± 0.08
(0.025 ± 0.003)
2
4
1
7.62 (0.300)
7.12 (0.280)
0.23 min.
(0.009)
11
17
10
18
9
1
8
2
7
6
5
4
0.33 (0.013)
Rad.
0.08 (0.003)
3
2.03 ± 0.20
(0.08 ± 0.008)
1.02 ± 0.20
(0.04 ± 0.008)
LCC3
0.43 (0.017)
0.18 (0.007 Rad.
1.65 (0.065)
1.40 (0.055)
1.39 (0.055)
1.15 (0.045)
LCC4
0.30
(0.012)
Rad.
4 plcs
8.89 (0.350)
12
13
14
15
9.09 (0.358)
8.69 (0.342)
1.14 – 0.15
(0.045 – 0.006)
19
16
11
18
10
9
1
2
8
7
6
5
4
20
3
1
18
17
0.23
(0.009)
Rad.
18 plcs
4
0.711 (0.028)
0.559 (0.022)
9.09 (0.358)
8.69 (0.342)
0.65 (0.025)
typ.
1.27 (0.050)
typ.
7.24 (0.285)
0.76 (0.030)
0.51 (0.020)
14
3
8
13
2.54
(0.100)
1.14(0.045)
typ
2.36 (0.093)
1.96 (0.077)
3.81 ± 0.13
(0.15 ± 0.005)
1.39 (0.055)
1.02 (0.040)
1.40
(0.055)
Nom.
9
1.39 (0.055)
2.54 (0.064)
1.52 (0.100)
1.15( 0.045)
Dimensions in mm (inches)
LCC6/8/18
LCC20
7.54 (0.296)
0.89
(0.035)
min.
2.41 (0.095)
2.41 (0.095)
10.69 (0.421)
10.39 (0.409)
5.72 (.225)
2
0.76
(0.030)
min.
3
10.16 (0.400)
1
0.76
(0.030)
min.
3.05 (0.120)
0.127 (0.005)
3.70 (0.146)
3.41 (0.134)
3.175 (0.125)
Max.
4.14 (0.163)
3.84 (0.151)
min.
3.70 (0.146)
3.41 (0.134)
1
3.60 (0.142)
Max.
3
2
16.02 (0.631)
15.73 (0.619)
0.76 (0.030)
0.127 (0.005)
0.127 (0.005)
16 PLCS
0.50(0.020)
7.26 (0.286)
9.67 (0.381)
9.38 (0.369)
0.50 (0.020)
max.
11.58 (0.456)
11.28 (0.444)
SMD05
SMD1
15
0.50 (0.020)
0.26 (0.010)
Package Drawings
13.59 (0.535)
13.84 (0.545)
6.32 (0.249)
6.60 (0.260)
1.02 (0.040)
1.27 (0.050)
30.35 (1.195)
31.40 (1.235)
16.89 (0.665)
17.40 (0.685)
13.59 (0.535)
13.84 (0.545)
20.07 (0.790)
20.32 (0.800)
3.53 (0.139)
Dia.
3.78 (0.149)
1
2
3
0.89 (0.035)
1.14 (0.045)
TO257
TO254
6.86 (0.270)
6.09 (0.240)
2
19.05 (0.750)
12.70 (0.500)
1
12.7 (0.500)
min.
5.08 (0.200)
BSC
5.84 (0.230)
5.31 (0.209)
4.95 (0.195)
4.52 (0.178)
21.21 (0.835)
20.70 (0.815)
2.54 (0.100)
Nom.
4.19 (0.165)
3.94 (0.155)
Dia.
1 2 3
0.48 (0.019)
0.41 (0.016)
dia.
1.14 (0.707)
0.88 (0.035)
3
17.96 (0.707)
17.70 (0.697)
17.65 (0.695)
17.39 (0.685)
13.84 (0.545)
13.58 (0.535)
3.81 (0.150)
BSC
3.81 (0.150)
BSC
5.33 (0.210)
4.32 (0.170)
3.56 (0.140)
BSC
1.65 (0.065)
1.39 (0.055)
Typ.
TO258
TO18
38.00
(1.5)
min.
6.35 (0.25)
9.15 (0.36)
10.67 (0.42)
11.18 (0.44)
1.52 (0.06)
3.43 (0.135)
1
2
22.23
(0.875)
max.
0.97 (0.060)
1.10 (0.043)
16.64 (0.655)
17.15 (0.675)
38.61 (1.52)
39.12 (1.54)
8.51 (0.34)
9.40 (0.37)
3
7.75 (0.305)
8.51 (0.335)
2
5.08 (0.200)
typ.
1
29.9 (1.177)
30.4 (1.197)
0.41 (0.016)
0.53 (0.021)
dia.
45°
0.89
max.
(0.035)
0.71 (0.028)
0.86 (0.034)
0.74 (0.029)
1.14 (0.045)
6.10 (0.240)
6.60 (0.260)
25.15 (0.99)
26.67 (1.05)
3
(case)
2.54
(0.100)
3.84 (0.151)
4.09 (0.161)
7.92 (0.312)
12.70 (0.50)
TO5
TO3
40.76
37.97
35.70
25.00
27.27
32.80
25.43
34.34
2.54 11 PLCS
5.02
27.940
3.955
2.430
0.780
PIN 1 IDENT
7.745
3.20
3.83
2.50
DIMENSIONS IN mm
TOLERANCE ± 0.125 mm
SM Power MCA
Power MCA
16
Ø0.570-0.650
9. MIL-PRF-19500 – QR216, QR217 (Space)
9.1 Space Level Processed Discrete Semiconductors (MIL-PRF-19500)
QR217: ‘Space Level’ Full Quality Conformance Inspection.
QR216: ‘Space Level’ Discrete Component Screening
SEMELAB’s QR217 and QR216 processing specifications, in conjunction with the company’s ISO
9001:2000 approval present a viable alternative to American MIL-PRF-19500 space level parts
supplied from a European manufacturer.
QR217 (quality conformance) is based on the quality conformance inspection requirements of
MIL-PRF-19500 groups A (table V), B (table VIa), C (table VII) and also ESA / ESCC 5000 (chart F4) lot
validation tests.
QR216 (screening) is based on the screening requirements of MIL-PRF-19500 (table IV) and also
ESA /ESCC 5000 (chart F3). Details of QR217 and QR216 are included in the following pages.
All manufacture and processing is carried out on our approved High-Rel assembly line in
Lutterworth and product is released under our ISO 9001:2000 defence standard approval.
The ‘standard’ JQRS part is processed to the Semelab data sheet, screened to QR216 and has
conformance testing to Q217 groups A and B. Available options and the associated part number
extensions are shown below. These are chargeable and must be specified at order stage.
The extensions on the Semelab part numbers used reflect these additional items.
Ordering Information: (example)
Part Number
Description
Marking (*)
2N2369-JQRS
QR217 groups A,B Screening to QR216
2N2369-JQRS
Additional options:
Customer Pre-Cap Visual Inspection
Customer Buy-Off visit
Data Pack
-CVP
-CVB
-DA
Group B charge
Group B destructive mechanical samples
-GRPB
-GBDM (12 pieces)
Group C charge
Group C destructive electrical samples
Group C destructive mechanical samples
-GRPC
-GCDE (12 pieces)
-GCDM (6 pieces)
Solderability Samples
Scanning Electron Microscopy
Radiography (X-ray)
Total Dose Radiation Test
-SS
-SEM
-XRAY
-RAD
Notes:
1) All ‘Additional Options’ are chargeable and must be specified at order stage.
2) When Group B or C is required, additional electrical and mechanical destructive samples must be ordered
3) All destructive samples are marked the same as other production parts unless otherwise requested.
pages extracted from ‘Semelab - High Reliability and Screening Options’
17
MIL-PRF-19500 – QR216, QR217 (Space)
(continued)
9.2 QR217 Inspection Levels for ‘Space Level Processed’ Products
QR217: Group A - Electrical Tests
*small lot conformance
Subgroup
Description
1
Visual + mechanical Inspection
Sample*
20
Reject
0
2
DC electrical tests at 25°C
20
0
3
DC electrical tests. Hot & Cold temps as per device datasheet
45
0
4
AC electrical tests at 25°C
45
0
5
Safe Operating Area (Power Transistors)
Endpoint electrical measurements
8
0
The specified parameters to be included in each subgroup shall be as per Semelab Data Sheet. Where no parameters are specified
in a particular subgroup or test within a subgroup, no Group A testing is required for that subgroup or test to satisfy Group A
requirements. A single sample may be used for all subgroup testing. These tests are considered non-destructive.
QR217: Group B - Short term Environmental & Endurance Tests *small lot conformance
Test
note
Subgroup 1
Physical Dimensions
Subgroup 2
Solderability
Resistant to solvents
(3)
(3)
Subgroup 3
Thermal shock
(liquid to liquid)
Temperature Cycling
(air to air)
MIL-STD-750
method
Sample*
Reject
d=destructive
2066
As per specification
2026
1022
(minimum 3 devices)
(Separate samples can be used)
1056
Test condition B (25 cycles)
(glass diodes only)
1051
Hermetic seal
(a) Fine Leak
(b) Gross leak
Condition
8
0
6d leads
6d devices
6d
0
6d
0
Test condition C or max stg temp,
whichever is less. 100 cyles.
1071
Test condition H.
<0.01cc. max = 5 x 10-9 atm cc/s,
>0.01cc. max = 1 x 10-8 atm cc/s
2075
Visual criteria in accordance
with qualified design.
Bond strength
2037
(minimum 6 devices)
12 wires d
0
Die Shear
2017
Parts from bond strength (min=6)
6d
0
1027
1037
340hrs at specified bias conditions
12
0
As per SEMELAB specification
6
0
340hrs high temperature storage
As specified
12
0
Electrical Measurement
Internal visual design
verification
Subgroup 4 / 5
Steady-state operation life
or Intermittent operation life
or Blocking life
(4)
(5)
Electrical Measurements
Subgroup 6
Thermal resistance
As specified
3131 and
SML 7404
Subgroup 7
High temperature life
(non operating)
1032
Electrical Measurements
(Minimum quantity of destructive samples required is 12 pieces)
(Full notes for numbered references are at the end of group C table)
pages extracted from ‘Semelab - High Reliability and Screening Options’
18
MIL-PRF-19500 – QR216, QR217 (Space)
(continued)
QR217: Group C - Long term Environmental & Endurance Tests
Test
note
Subgroup 1
Physical Dimensions
MIL-STD-750
method
Condition
*small lot conformance
Sample*
Reject
d=destructive
2066
Dimensions per case outline specified
6
0
1056
Test condition B (25 cycles)
6d
0
Temperature Cycling
(air to air)
1051
Test condition C or max stg temp,
whichever is less.
(45 cycles inc. screening)
Shock
2016
Non operating, 1500G, 0.5ms, 5
blows in each orientation, X1, Y1, Z1
(Y1 only for axial glass diodes)
Vibration
(Variable frequency)
2056
Hermetic seal
(a) Fine Leak
1071
Test condition H.
<0.01cc. max = 5 x 10-9 atm cc/s,
>0.01cc. max = 1 x 10-8 atm cc/s
b) Test condition C
Moisture resistance
1021
Omit initial conditioning
Terminal strength
2036
As specified
see (2)
6d
0
6
0
12d
0
see (2)
3d
5d
0
1
Subgroup 2 & 3
Thermal Shock
(glass strain)
(b) Gross leak
Electrical Measurement
Subgroup 4
Salt atmosphere
(corrosion)
As specified
(2)
Subgroup 5
Thermal resistance
Subgroup 6
Steady-state operation life
1041
Covered by MIL883 ongoing
Group D programme
3131 and
SML 7404
As per SEMELAB specification
1026
or Intermittent operation life
or Blocking life
1036
1000hrs at max operating
junction temp
As specified
Electrical Measurements
Subgroup 7
Internal Gas Analysis
(corrosion)
(2)
Covered by MIL883 ongoing
Group D programme
(Minimum quantity of destructive samples required is 18 pieces)
1) Individual subgroups may be performed on representative parts from the same package family.
2) Group C subgroup 4 and 7 are covered by MIL883B ongoing group D programme. If customers require these subgroups to
be done on the specific batch being covered, an additional ‘Grp C extra’ charge applies and an additional 11 destructive
samples must be ordered. This must be specified at order stage.
3) Electrical reject devices from the same inspection lot may be used for all subgroups when electrical end point measurements
are not required.
4) Post burn-in electrical rejects may be used.
5) If a given inspection lot undergoing Group B inspection has been selected to satisfy Grp C inspection requirements, the 340
hour life test may be continued to 1000 hrs to satisfy the Group C life test requirements. In such cases, either the 340 hour end
point measurements must be made as a basis for Group B lot acceptance or the 1000 hour end point measurement shall be
used as the basis for both Group B and Group C acceptance.
6) Internal Visual Design Verification may be omitted if the devices have been manufactured by Semelab as sample pre-cap visual
inspection will have been performed.
pages extracted from ‘Semelab - High Reliability and Screening Options’
19
MIL-PRF-19500 – QR216, QR217 (Space)
(continued)
9.3 QR216: ‘Space Level’ Discrete Component Screening
QR216: Discrete Component Screening (with reference to MIL-STD-750)
Description
MIL-STD-750
method
1
Internal Visual (Pre-cap) Inspection
2069, 207, 2072
2
Customer Pre Cap Visual Inspection
2069, 2070, 2072
Customer specified option (chargeable)
100%
3
High temperature stabilisation bake
1032
24 hrs min at rated maximum
storage temperature
100%
20 cycles at -55°C to +175°C or max
storage temp (whichever is lower)
with minimum 10 minutes dwell time
100%
20,000G force in Y1axis for 1 min duration
(see note 2)
100%
(full yielded quantity)
100%
4
5
Temperature Cycling
Constant acceleration
Conditions
JQR-S
100%
1051
2006
6
Particle Impact Noise Detection (PIND)
7
Device Serialisation
2052
Device serialisation is carried through to shipping.
8
Interim electrical
Read & Record
100%
9
High temperature reverse bias
a) Bipolar
b) Power MOSFET
c) Diodes
Test Condition A
Test Condition B
Test Condition A
100%
Read & Record, Drift Check
100%
1039
1042
Test Condition B - 240 hrs min
Test Condition A - 240 hrs min
100%
1038
Test Condition B - 240 hrs min (4)
Read & Record, Drift check (1)
100%
1071
100%
100%
1039
1042
1038
10 Interim electrical (note 3)
11 Power burn-in
a) Bipolar
b) Power MOSFET
c) Diodes
12 Final electricals (note 3)
13 a) Hermeticity – Fine
b) Hermeticity - Gross
1071
Test condition H. Max leak rate =5x10-8 atm cc/s,
(5x10-7 atm cc/s for internal cavity <0.3cc)
Condition C
14 Radiographic tests (X-Ray)
2076
(May be performed at any time after serialization)
15 External Visual Inspection
2071
Notes:
1) QR217 Group A subgroups 2 and 3 end point tests as per device detail spec.
2) 10000G force for devices with power rating >10 watts at Tc=25°C.
3) PDA (percentage defects allowable) is 10% between steps 8 & 10 and 10 & 12.
4) Zener diodes shall be subjected to high temperature reverse bias at 80 - 85 percent of nominal VZ for VZ > 10 V.
Omit test for devices with VZ ≤ 10 V. For JQRS case mounted rectifiers condition A is required.
pages extracted from ‘Semelab - High Reliability and Screening Options’
20
100%
10. ESA/ESCC - Space Level Product
Semelab’s Space Quality Level Products are based on the testing procedures specified in the generic
ESCC 5000 issue 3 and in the corresponding Detail Specifications.
All manufacture and processing is carried out on our approved High-Rel assembly line in our
Lutterworth factory and product is released under our ISO 9001:2000 defence standard approval.
The table below shows the additional options which may be required by the customer. All items
must be agreed and specified at order stage.
The following pages show the generic chart F2 (component lot manufacturing), chart F3 (screening)
and chart F4 (Validation) requirements.
Additional options:
Customer Pre-Cap Visual Inspection
Customer Buy-Off visit
Data Pack
-CVP
-CVB
-DA
Lot Validation Testing (subgroup 1) charge
LVT1 destructive samples (electrical)
LVT1 destructive samples (mechanical)
-LVT1
-L1DE (normally 15 pieces)
-L1DM (normally 15 pieces)
Lot Validation Testing (subgroup 2) charge
LVT2 destructive samples (electrical)
-LVT2
-L2D (normally 15 pieces)
Lot Validation Testing (subgroup 3) charge
LVT3 destructive samples (electrical)
-LVT3 (normally 5 pieces)
Scanning Electron Microscopy (SEM)
Radiography (X-ray)
Total Dose Radiation tests
-SEM
-XRAY
-RAD
Notes:
1) All ‘Additional Options’ must be specified at order stage
2) All ‘Additional Options’ are chargeable
3) All destructive samples are marked the same as other production parts unless otherwise requested.
pages extracted from ‘Semelab - High Reliability and Screening Options’
21
ESA/ESCC (Space Level Flow)
(continued)
10.1 Chart F2 - Production Control (ESCC 5000 issue 3)
Component Lot manufacturing
Wafer Lot Acceptance
para 5.3.1
Process Monitoring Review
para 5.3.2
SEM Inspection
para 5.3.3
Total Dose Rad Testing (1,4)
Special In - Process controls
para 5.2.1
Internal Visual inspection (Pre-cap inspection)
para 5.2.1
Bond Strength (Pre-cap inspection)
(1)
para 5.2.1
Die Shear (Pre-cap inspection)
(1)
para 5.2.1
Encapsulation (Pre-cap inspection)
(1)
para 5.2.1
Dimension Check
(1)
para 5.2.3
Weight
(2)
To Chart F3 (Screening)
Notes:
1) Performed on a sample basis.
2) Guaranteed but not tested.
3) If specified in the detail specification.
4) If specified in the detail specification and required in the Purchase Order.
pages extracted from ‘Semelab - High Reliability and Screening Options’
22
(1,3)
10.2 ESA/ESCC - Chart F3 Screening (ESCC 5000 issue 3)
Components from Production Control
para 8.5
High Temperature Stabilisation Bake
Electrical Test
para 8.6.1
(11)
Temperature Cycling
Acceleration
(10)
para 8.7
Particle Impact Noise Detection (PIND)
para 8.22
Verification of Safe Operating Area
para 8.9.1
Electrical Measurements, Serialisation
and Parameter Drift Values
(1)
para 8.20
High Temperature Reverse Bias Burn-In
(2)
para 8.9.1
Parameter Drift Values
HTRB Final and Power Burn-In Intial Measurements
(1)
para 8.21
Power Burn-In
(2)
para 8.9.1
Parameter Drift Values (Final Measurements)
(4)
para 8.9.2
High and Low Temperature Electrical Measurements
(2,3)
(4,5)
Hot Solder Dip (if applicable) (6)
para 8.3
Radiographic Inspection
(9)
para 8.8.1&2
Seal (Fine & Gross Leak)
para 8.9.3
Room Temperature Electrical Measurements (inc AC)
para 6.4.1
Check for Lot Failure
(8)
para 8.10
External Visual Inspection
(8)
para 8.16
Solderability
(4,7)
(4,5)
To Chart F4 (Validation Testing)
Notes:
1) All components shall be serialised prior to Initial Electrical Measurement.
2) If specified in detail spec.
3) Can be performed at any time prior to initial measurements of Parametric Drift values.
4) The Lot Failure criteria of paragraph 6.4 applies to this test.
5) Performed on a sample basis.
6) Can be performed at any time prior to Room Temp Electrical Measurements during screening (prior to Seal test).
7) Measurements of parametric Drift Values need not be repeated in Room Temperature Electrical measurements.
8) Check for Lot Failure shall take into account all electrical parameter failures that may occur during screening.
Tests in accordance with paragraph 8.9.1, 8.9.2, 8.9.3 subsequent to HTRB Burn-In.
9) Radiographic Inspection may be performed at any point during Screening Tests.
10) Not specified in ESCC 5000 iss 3, but performed by Semelab to MIL-STD-750 method 2006.
11) Not specified in ESCC 5000 iss 3, but performed by Semelab as a process monitor.
pages extracted from ‘Semelab - High Reliability and Screening Options’
23
ESA/ESCC (Space Level Flow)
(continued)
10.3 Chart F4 - Validation Testing (ESCC 5000 issue 3)
Components for Validation
LVT1
(Subgroup 1)
Mechanical & Environmental
LVT2
(Subgroup 1)
Endurance
LVT3
(Subgroup 3)
Assembly Capability
15 Components
15 Components
15 Components
5 Components
Mechanical Shock
para 8.11
Thermal Shock (2)
para 8.11
Vibration
para 8.12
Temp Cycling (3)
para 8.6.2
Operating Life (4)
2000 hours
data points:
0, 1000, 2000hrs
para 8.19
Terminal Strength
para 8.18
Constant
Acceleration
para 8.13
Moisture
Resistance
para 8.15
Immediate & End
Ppoint Electrical End
Measurements
para 8.9.4
Internal Visual
Inspection
para 8.1
Seal
para 8.8.1 & 8.8.2
Seal
para 8.8.1 & 8.8.2
Seal
para 8.8.1 & 8.8.2
Bond Strength
para 8.2.1
Immediate & End
Ppoint Electrical End
Measurements
para 8.9.4
Immediate & End
Ppoint Electrical End
Measurements
para 8.9.4
External Visual
Inspection
para 8.10
Die Shear
para 8.2.2
External Visual
Inspection
para 8.10
External Visual
Inspection
para 8.10
Permanence of
Marking
para 8.17
LVT1 (Subgroup 1)
Lot Validation
LVT2 (Subgroup 2)
Lot Validation
LVT3 (Subgroup 3)
Lot Validation
Notes:
1) ESCC 5000 iss 3 table F4 - Qualification & Periodic Testing becomes ‘Validation Testing’ for non qualified parts.
2) Only applicable to axial diodes.
3) Not applicable to axial lead glass diodes.
4) Variance in Test method based on product type.
Ordering Information:
1) Order for Subgroup 1 (includes subgroups 2 & 3) requires order for 50 (30+15+5) destructive samples.
2) Order for Subgroup 2 (includes subgroup 3) requires order for 20 (15+5) destructive samples.
3) Order for Subgroup 3 requires order for 5 destructive samples.
4) Other Ordering Options are available - please contact Semelab Sales
pages extracted from ‘Semelab - High Reliability and Screening Options’
24
11. Screening & Approval Comparison Tables
11.1 Comparison of Space Level Screening Options
Space Level Flow Comparison Table
GENERIC
Screening
QR216
ESCC
JANS*
JQRS
OPT
OPT
OPT
24 hrs
24 hrs
24hrs
Temperature cycling
20 cycles
20 cycles
20 cycles
Thermal impedance
OPT
Pre-cap Visual
Customer pre-cap Visual
High Temp Storage (Stabilization Bake)
Constant Acceleration
-
_
PIND
Fine/Gross Leak ∑
Serialization
Interim Electrical Measurements
-
-
-
-
-
-
min 168 hrs
max 264 hrs
240 hrs
240hrs
-
-
-
Interim Electrical Measurements (Read and Record / Drift)
HTRB
Electrical Measurements
Parametric Drift measurements (Read and Record / Drift)
Burn-In
Electrical Measurements
Parameter Drift Measurements (Read and Record)
PDA Calculations
Read and Record Test Data
Other Electrical Parameters (Temp, Dynamic)
Fine/Gross Leak
Radiography
External Visual Inspection
Notes:
if specified in detail specification.
_ not specified in ESCC 5000 iss 3, but performed by Semelab.
pages extracted from ‘Semelab - High Reliability and Screening Options’
25
*JANS part not available from Semelab.
Screening & Approval Comparison Tables
11.2 Comparison of Space Level Die Lot Approval Procedures.
The table below shows a comparison of operations carried out for die approval within the generic
approval systems (MIL-PRF-19500 space level and ESA / ESCC 5000. It must be noted that SEM and
RHA total dose evaluation are options which must be specified if required carry an additional charge.
Space Level/ Die Lot Acceptance Table
GENERIC
Die Lot Acceptance
SML
ESCC
JANS
JQR-S
SEM
OPT
OPT
OPT
RHA Total Dose Evaluation
OPT
OPT
OPT
Selected Wafer
Probe Test (100%)
Glassivation / Metallization Inspection
Visual Inspection (100%)
Sample Assembly (10 pcs)
Stabilization
Temperature Cycling
Electrical Test (read/record)
HTRB
Electrical Test (read/record)
Steady State Life (1000 hrs)
Electrical Test (read/record)
Wire Bond Evaluation
Die Shear Evaluation
pages extracted from ‘Semelab - High Reliability and Screening Options’
26
Screening & Approval Comparison Tables
11.3 Comparison of High-Rel Screening Options (Discrete Devices)
The table below shows the comparison of screening options available within the CECC, BS and MIL
approvals. Comparison is also shown with Semelab’s in-house QR204 options.
CECC / QR209
A
B
C
BS 9300
D
A
B
C
QR204
D
MIL
JQRA JQRB JAN* JAN*
TXV TX
Pre-cap Visual
High Temp Storage
Temperature Cycle
5
5
5
cycles cycles cycles
10
10
10
cycles cycles cycles
20
20
20
20
cycles cycles cycles cycles
Constant Acceleration
Particle impact noise
detection (PIND)
Fine Leak test
Gross Leak Test
Device Serialisation
Variables Electrical test
±
±
±
±
±
±
±
±
160
hrs*
160
hrs*
160
hrs*
160
hrs*
±
±
±
±
Attributes Electrical tests
Burn-In (HTRB)
168
hrs*
172
hrs*
48
hrs*
160
hrs*
72
hrs*
48
hrs*
48
hrs*
Variables Electrical test
Attributes Electrical tests
Burn-In (Power)
168
hrs*
172
hrs*
48
hrs*
160
hrs*
72
hrs*
48
hrs*
Variables Electrical test
48
hrs*
Attributes Electrical tests
Radiographic tests
* full JANTX, JANTXV not available from Semelab
Test Performed
± Test Performed if required by device detail specification
24 hours for PNP devices. 48 hours for NPN devices
* High Temp Reverse Bias for Case rated devices
Power Burn-in for Ambient rated Devices
CECC / QR209
BS
QR216
QR204
MIL
: Screening carried out in accordance with CECC 50000 Appendix 6
: Screening carried out in accordance with BS9300 section 1.2.10
: Screening carried out in accordance with Semelab QR216
: Screening carried out in accordance with Semelab QR204
: Screening carried out in accordance with MIL-PRF-19500 (Table 2)
pages extracted from ‘Semelab - High Reliability and Screening Options’
27
Experience and Innovation in Semiconductor Solutions
Specialists in
• Chip design and wafer fabrication
• Plastic packaged devices
• Ceramic surface mount products
• Metal packaged devices
• Power modules
• Standard and custom products
• Screening and qualification
• Continuity of supply
Your Semelab Distributor:
ISO 9001
FM36235
M/0103/CECC/UK
Semelab Plc
Coventry Road,
Lutterworth,
Leicestershire. LE17 4JB
UK
BS 9000
1360/M
DSCC
Qualified
Manufacturers
List
Defence
Supply
Center
Columbus
European
Space Agency
MOD
Registration
VQC-03-003050
VQC-03-003049
Cage
Code U3158
Qualification 253
2M8S02
Tel: +44 (0) 1455 556565
Fax: +44 (0) 1455 552612
Email: [email protected]
Web: www.semelab.co.uk
www.semelab.com
Members of the
Component
Obsolescence
Group