High Reliability & Screening Options

Semelab Limited
High Reliability and Screening Options
DOC 2624 ISS 8
Contents
1. Introduction................................................................................................ 1
2. Quality Approvals ...................................................................................... 2
3. Material Qualification ................................................................................ 3
3.1 Header/Cap/Wire Approval Procedures...................................................................... 3
3.2 Die Approval Procedure............................................................................................... 4
4. CECC (Discrete Products)......................................................................... 5
4.1 Inspection Levels for CECC Fully Assessed Devices............................................... 5
4.2 CECC Screening Options ............................................................................................ 7
4.3 CECC processed devices (QR208, QR209) ................................................................ 8
5. BS (Linear Products) ................................................................................. 9
5.1 Inspection Levels for BS Fully Assessed Devices.................................................... 9
5.2 BS Screening Options (Linear IC’s).......................................................................... 11
6. BS & CV (Discrete Products) ...................................................................12
6.1 BS and CV processed devices (Bipolar) .................................................................. 12
7. DSCC / 883B (Linear Products) ...............................................................13
7.1 Inspection Levels for DSCC SMD listed Devices .................................................... 13
7.2 Screening Sequence for DSCC SMD listed devices ............................................... 15
7.3 MIL-883B Processed Integrated Circuits (QR214, QR215) ..................................... 16
8. MIL-PRF-19500 - QR205, QR204 (Aerospace)........................................ 17
8.1 QR205 - Inspection levels: ‘Mil Processed’ Quality Conformance ........................ 18
8.2 QR204 - Screening Sequences ‘Mil Processed’ Components ............................... 20
9. MIL-PRF-19500 - QR216, QR217 (Space) .............................................. 21
9.1 Space Level Processed Discrete Semiconductors (QR216, QR217) ..................... 21
9.2 QR217 - Inspection levels: ‘Space Level Processed’ Conformance ..................... 22
9.3 QR216 - Screening: Space Level Processed’ Components ................................... 24
10. ESA - ESCC (Space) ................................................................................ 25
10.1 Chart F2 - Production Control ................................................................................ 26
10.2 Chart F3 - Screening Tests ..................................................................................... 27
10.3 Chart F4 - Qualification and Periodic Tests.......................................................... 28
11. Screening & Approval Comparison Tables ........................................... 29
11.1 Comparison of Space Level Screening Options ................................................... 29
11.2 Comparison of Space Level Die Lot Approval....................................................... 30
11.3 Comparison of Hi-Rel Screening options .............................................................. 31
DOC 2624 iss 8a (DMD) 01/09
DOC 2624 ISS 8
1. Introduction
Experience and Innovation In Semiconductor Technology
At SEMELAB, we research, design, manufacture and distribute an innovative range of
semiconductor products throughout the world.
Our R&D teams have an excellent track record for developing imaginative electronic
solutions. Our design engineers have created a wealth of high performance products. Our
manufacturing divisions have ensured supreme quality and reliability. And our sales teams
and distribution partners have opened international markets to some of the best electronics
solutions available.
We hold the necessary Qualification Approvals needed to serve the Military and Hi-Rel
Industries now including QML Approval for a series of Linear Integrated Circuits and QML
Approval for our laboratory test house capabilities. The test facilities are available to qualify
and screen third party products, including Hybrid products not made by the Group. We have
the ability and considerable experience of most test methods currently demanded.
We specialise in the fabrication of very high quality products especially intended for use in
high reliability applications. We have supplied many millions of discrete and linear integrated
circuits into all forms of high reliability equipment such as:
• Space
• Aircraft
• Communications
• Defence
•
Transportation
•
Harsh Environment
Satellite Vehicles
Launchers
Support & defence
Military
Civil
Air Traffic Control
Secure Communication Links
Military links
Naval Links
Broadcast Transmitters
Underwater Repeaters
Guided weapons
Electronic Counter Measures
Command & Control
Radar
Railway Signalling Systems
Traction Systems
Automatic Signalling Systems
Oil Rig Installations
Drill Head Sensors
Atomic Event Detectors
--- everywhere, when there is a need for cost effective ultra reliable products.
This is SEMELAB: design innovation, backed by numerous approvals and manufacturing
strength and led by a total commitment to quality.
1
DOC 2624 ISS 8
2. Quality Approvals
Description
SML Facilities
Approval (Y/N)
SEMELAB
Approval
Number
SML Devices Types
Approved
Remarks
BS9000
British Standards for
Linear ICs and
Discrete
Semiconductors
Y detailed
approval for
many products
1360/M
Linear ICs and
Discrete
Semiconductors
Replaced in many areas by CECC or DSCC.
Approved suppliers and products listed in
PD9002
BS EN ISO
9001:2000
International
Standard for Quality
Assurance
management of all
phases in the
provision of goods
and services.
Replaces most old
"national" systems.
Y
FM36235
refers to all
product types
The whole Semelab facility and all
Products conform to these norms.
CECC 50000
European Military
Quality Approval
system for Discrete
Semiconductors
Y
detailed approval
for many products
M1040 IECQ
iss2
Small signal
discretes,
Power discretes
European QPL. Generally in decline
CECC 90000
European Military
Quality Approval
system for ICs.
Y
detailed approval
for many products
M1040 IECQ
iss2
Linear ICs.
European QPL. Generally in decline
DSCC QPL
approval
US Manufacturing
approval accepted
everywhere
Y
detailed approval
for large range
of linear ICs.
Cage NO.
U3158
Linear ICs
Detailed product approval by DSCC
(commonly called MIL/883B for linear ICs)
DSCC QML
approval
US Manufacturing
approval accepted
everywhere
Y
DSCC -VQ03-003050 &
DSCC-VQ03-003049
Linear ICs
(lvl Q certification)
Laboratory
Suitability
Will generally replace many of the older approval
systems on International Military Systems.
ESCC 5000,
ESCC 9000
European Space
Components
Coordination
Y
QPL No 253
2N2880 - more to
follow
Product built & supplied in accordance
with generic ESCC specifications
General reciprocal
listing arrangement
Y
All product types
Reciprocal QPL listing between
Europe and North America
SCHEME
Current Schemes
STANAG 4093
Schemes being phased out
AQAP-1
Applies in UK and
related areas.
Replaced Defence
Standard 05/21
Y
GAMT1
French Military
approved products
list
Y
detailed approval
for many products
MUAHAG
European - Military
users and
Harmonisation
Advisory Group
Y
detailed approval
for many products
NATO
NATO system –
applies to NATO
systems
MOD
Registration
No.2M8S02
Being superseded by BS/EN/ISO 9001
A large number
Discretes (vol 7)
Linears (vol 9)
French Market - should be replaced by
BS/EN/ISO9001
Components generally for European Military
equipment makers - should be replaced by
BS/EN/ISO9001
Y
listed for many
products
Manufacturer
Code 3158
Several hundred
discrete products
Tending towards being a legacy system now
Legacy Schemes
CV
Very early UK
approvals system for
Military and GPO
types
some parts
replaced by BS
types, CECC or
CVxxxx-0 parts
Legacy system – generally replaced
by BS or CECC types
DEF Specs
Precursor of Defence
Standard
Specifications
Many types
all built to order.
Replaced by Defence Standard Specifications.
Generally already phased out.
Defence
Standards
(many)
Relate to materials,
components and
processes for UK
Military use
Y
for many products
but under
ISO9001:2000
RRE, RSRE
& SRDE
Specifications
Specifications drawn
up in support of
MOD projects
Y
Discrete products
Legacy system little used now. The most
common DEF Stan relating to Semiconductors is
DEF STAN 05/21 - replaced by ISO 9001:2000
Discrete products
Legacy system little used now.
for many types
2
DOC 2624 ISS 8
3. Material Qualification
Piece Part – Qualification and pre-assembly approval process flow.
Before contemplating the assembly of any qualified semiconductor product, it is essential
that all the materials used in the construction of the parts be obtained from fully qualified and
trustworthy suppliers - those with a long continuous and successful supply history. Little used
or untried or suspect materials are thoroughly checked and qualified as being suitable for
their intended application before use.
In this case, mechanical piece parts are subject to an exhaustive series of tests culminating
in sample assemblies being built to establish lack of flaws and lack of unwanted difficulties
during assembly.
3.1 Header / Cap / Wire Approval Procedures
Incoming Mechanical Piece Parts
Visual inspection
Dimensional Check
Corrosion Resistance
Mechanical Strength
Visual Die Sort (before sample assembly)
Sample piece parts submitted to Assembly
Vibration test
Temperature Cycling
Acceleration
Sealing (Leak) Tests
QA Inspection Tests
Solderability Tests
Operation
Electrical Tests
Qualified (Approved) Mechanical Piece Parts
Available for Assembly of Hi-Rel Products.
Notes: Approval procedures are performed on samples to approve each single lot of
material.
Each batch of assembled piece parts carries its own unique “date” code. Traceability to each
incoming batch of materials (all mechanical batches and die lots) is guaranteed from this
unique number.
3
DOC 2624 ISS 8
3.2 Die Approval Procedure
Incoming Wafer
Wafer Saw
Wash & Dry
Headers*
(qualified)
Break into individual die
Clean
Visual Die sort and Tray
Die Acceptance
Die Attach
Die Attach Inspection
Aluminium Wire Bond
Bond Inspection
Caps*
(Qualified)
100% Optical Inspection
Clean
Final Pre-Cap Inspection
Vacuum Bake
Final Seal
QA Inspection Tests
Seal Inspection
Operation
Final Acceptance
Electrical Yield Forecasting
QA Acceptance Tests
168 Hour Life Test
Final QA Acceptance of the Die Lot.
APPROVED DIE (available for production)
All assembled batches carry full traceability back to all incoming materials used via a unique
Lot ID assigned at the beginning of the manufacturing stage
Qualification can include an additional 1000 hour or 2000 hour electrical endurance test if
required. One of the major objectives is to ensure that the die lot’s performance stabilises
rapidly during the initial portion of this period and then remain unchanged throughout the
remainder of the test (and life). All die lots assigned for space use have 2000 hours electrical
endurance as standard
Die and mechanical piece parts intended for use in Ultra-Reliable applications e.g. Space
Vehicles are subject to more rigorous evaluation.
4
DOC 2624 ISS 8
4. CECC (Discrete Products)
Registration: M1040 IECQ iss2
SEMELAB offers one of the largest ranges of CECC approved products in Europe, including
small signal and power devices. These devices have undergone approval for use in new
applications as well as providing continuing support for existing applications.
All piece parts used in the manufacture of CECC released products undergo stringent
qualification procedures before they can be used. For further details contact our Quality
Manager ([email protected]).
Full forward and backward traceability is maintained on all CECC released devices
All CECC fully assessed devices are subject to groups A, B and C inspection carried out in
the Quality Assurance Department in Lutterworth. Assessment is available to levels E, F & L.
Ordering Information (example):BDS18CECC
BDS18CECC-B
full assessment level (without additional screening)
CECC full assessment level + sequence B screen
4.1 Inspection Levels for CECC Fully Assessed Devices
Group A - Lot by lot inspection
IL = inspection levels
AQL = Acceptable Quality Level (%)
Levels of Quality Assessment
Level E
Examination or test
IL
AQL
Observations
Level F & Level L
IL
AQL
Notes
SUB-GROUP A1
Visual Inspection
I
0.65
I
0.65
SUB-GROUP A2a
Non operatives
II
0.15
II
0.15
SUB-GROUP A2b
Electrical Measurements
II
0.40
primary dc characteristics
II
0.65
1.0
if < 4 tests
if ≥ 4 tests
SUB-GROUP A3
Electrical Measurements
II
0.65
other dc characteristics
I
I
2.5
4
if < 4 tests
if ≥ 4 tests
1
ac characteristics
S4
S4
4
6.5
if < 4 tests
if ≥ 4 tests
SUB-GROUP A4
Electrical Measurements
S4
5
DOC 2624 ISS 8
CECC (Discrete Products)
Group B - Lot by lot inspection
(continued)
IL = inspection level amb = ambient rated case = case rated
AQL in %
c = acceptance criterion n = sample size
Levels of Quality Assessment
Level E
Examination or test
Level F
Level L
n/c
IL
AQL
IL
AQL
SUB-GROUP B1
Dimensions
15/0 or 25/1
S2
2.5
S2
2.5
SUB-GROUP B2c
Verification of ratings
15/0 or 25/1
S4
4
NA
NA
SUB-GROUP B3
Lead bending if applicable
15/0 or 25/1
S3
2.5
S2
4
SUB-GROUP B4
Solderability
22/0 or 38/1
S4
2.5
S4
2.5
15/0 or 25/1
S4
2.5
NA
NA
see C5
see (1) below
38/1 or 52/2
S4
1.5
NA
NA
see C8
SUB-GROUP B5
Temperature Cycle. Acceleration.
Seal test or Damp Heat test
SUB-GROUP B8
Electrical endurance
Notes
see C2c
Unless otherwise stated in detail specification:
attributes information for B3, B4, B5, B8 in CECC specifications
SUB-GROUP CTR
Group C - Periodic Inspection
P = periodicity (months) na= not applied
Levels of Quality Assessment
E (p = 3 months)
Examination or test
n/c
notes
F (p = 3
months)
n/c
notes
L
P
n/c
SUB-GROUP C1
Dimensions
8/0 or 13/1
8/1
3
8/1
SUB-GROUP C2a
Electrical Measurements
15/0 or 25/1
13/1
3
13/1
SUB-GROUP C2b
Complementary characteristics
32/0 or 55/1
15/0 or 25/1
18/1
3
18/1
SUB-GROUP C2c
Verification of ratings
15/0 or 25/1
13/1
3
8/1
SUB-GROUP C3
Tensile / Torque (if applicable)
15/0 or 25/1
8/1
6
8/1
SUB-GROUP C4
Soldering heat
22/0 or 38/1
18/1
NA
NA
3
13/1
SUB-GROUP C5
Temperature Cycle. Acceleration.
Seal test or Damp Heat test
NA
versus T
versus I,V
see B5 in
CECC
NA
when not
in B2c
see B5 in
CECC
SUB-GROUP C6
Shock acceleration vibration
15/0 or 25/1
8/1
6
8/1
SUB-GROUP C7
Damp heat (if applicable)
15/0 or 25/1
18/1
NA
NA
SUB-GROUP C8
Electrical endurance
38/1 or 52/1
43/3
34/2
amb
case
3
3
32/3
25/2
SUB-GROUP C9
Storage at high temp
38/1 or 52/2
43/3
34/2
amb
case
NA
NA
SUB-GROUP CTR
Notes
See (1)
below
amb
case
Unless otherwise stated in detail specification: attributes information
for C3, C5, C6, C9. Measurement information before and after C8
(1) 2 chamber method. T=30 mins, 5 cycles. At maximum and minimum rated storage temperatures
6
DOC 2624 ISS 8
CECC (Discrete Products)
(continued)
4.2 CECC Screening Options
All CECC approved devices can be supplied as a standard full assessment level part or with
additional 100% screening to any of the four levels (A, B, C, D) in accordance to CECC
50000 Appendix VI
In addition, SEMELAB can supply screening on products where the full device approval does
not exist or is not held. Screening is again carried out in accordance with any of the four
levels within CECC 50000 Appendix VI and is carried out at our factory in Lutterworth.
Screening sequences are as laid out below:-
SEQUENCE A
SEQUENCE B
SEQUENCE C
SEQUENCE D
24 Hour High
Temperature
Storage
24 Hour High
Temperature
Storage
24 Hour High
Temperature
Storage
Rapid change of
Temperature
Rapid change of
Temperature
Rapid change of
Temperature
Acceleration
Test
Acceleration
Test
Acceleration
Test
Fine & Gross Leak
Test
Fine & Gross
Leak Test
Fine & Gross Leak
Test
Test & record
Electrical
Characteristics
Test
Electrical
Characteristics
Test
Electrical
Characteristics
168 Hour Burn-In
Electrical
Operation
(ambient rated) or
High Temperature
Reverse Bias
(case rated)
72 Hour Burn-In
Electrical
Operation
(ambient rated) or
High Temperature
Reverse Bias
(case rated)
48 Hour Burn-In
Electrical
Operation
(ambient rated) or
High Temperature
Reverse Bias
(case rated)
Test & record
Electrical
Characteristics
Test
Electrical
Characteristics
100% Internal
Visual Inspection
Test
Electrical
Characteristics
7
Test
Electrical
Characteristics
DOC 2624 ISS 8
CECC (Discrete Products)
(continued)
4.3 CECC Processed Devices
QR208: Conformance to the requirements of CECC 50000
QR209: Screening to the requirements of CECC 50000 App VI
QR208 and QR209 are based entirely on CECC 50000 quality conformance inspection
requirements and screening options.
By working to these specifications SEMELAB are able to supply full CECC “look alike”
products, where no CECC specification exists, released under the company’s ISO9001:2000
approval. Standard processing is done in accordance with Group A (electrical) and Group B
(environmental) tests to full assessment level F. Group C tests and level E assessment
levels are optional and are available on customer request.
Part numbers for products processed to QR208 and QR209 have -QR added (and a letter
corresponding to the screening level if required). The marking for the device has the suffix ‘O’ added (and a letter corresponding to the screening level if screened).
Semelab are also able to process devices to existing CECC specifications where we have
not undergone an approval exercise. This is particularly useful when Semelab want to supply
products in a smaller volume that does not justify the cost of the full approval exercise.
Part numbers for parts processed to detailed specifications will have the suffix ‘-O’ added to
the original part number (and a letter corresponding to the screening level if required). The
marking for the device has the suffix ‘-O’ added (and a letter corresponding to the screening
level if screened).
Ordering Information (when no CECC specification exists):Part Number
Description
Marking (*)
2N5153-QR
QR208 gps A, B level F
2N5153-O
2N5153-QR-B
QR208 gps A, B level F + QR209 sequence B
Processed to CECC full assessment level F, Groups A, B
2N5153-O/B
Processed to CECC full assessment level F, Groups A, B
with screening in accordance with CECC 50000 App VI seq B
2N5153-QR-EB
QR208 gps A, B level E + QR209 sequence B
2N5153-O/B
Processed to CECC full assessment level E, Groups A, B
with screening in accordance with CECC 50000 App VI seq B
2N5153-QR-EBC
QR208 gps A, B, C level E + QR209 sequence B
2N5153-O/B
Processed to CECC full assessment level E, Groups A, B, C
with screening in accordance with CECC 50000 App VI seq B
* Where space permits
8
DOC 2624 ISS 8
5. BS (Linear Products)
Registration 1360/M.
SEMELAB offers a range of BS approved Linear IC’s including Voltage regulators, PWM’s
and Control IC’s. These families of devices have undergone approval for use in new
applications in addition to providing continuing support for existing applications.
Full forward and backward traceability is maintained on all BS released devices
All BS fully assessed devices are subject to groups A,B,C and D inspection carried out in the
Quality Assurance Department in Lutterworth. Screening is available to any of the four levels
defined in BS9400 (S1, S2, S3, S4)
The generic specifications for these devices are as follows:
BS9400
BS9430
BS9493
IC’s - Generic Data & Methods of Test
Linear Voltage Regulators
PWM and Control IC’s
Ordering Information (example):IP117K-BSS2 BS full assessment level + category S2 screening
5.1 Inspection Levels for BS Fully Assessed Devices
Group A - Lot by lot inspection
IL = inspection levels
AQL = Acceptable Quality Level (%)
Levels of Quality Assessment
Examination or test
IL
AQL
BS9400
SUB-GROUP A1
Visual Inspection
I
1.5
1.2.2
SUB-GROUP A2
Non operatives
II
0.15
SUB-GROUP A3a
Electrical Measurements
II
1.5
Static Characteristics Tamb=25°C
SUB-GROUP A3b
Electrical Measurements
II
1.5
Static Characteristics Tamb = Tmax
SUB-GROUP A3c
Electrical Measurements
II
1.5
Static Characteristics Tamb = Tmin
SUB-GROUP A4a
Electrical Measurements
S4
4%
Dynamic Characteristics Tamb = 25°C
9
Observations
DOC 2624 ISS 8
BS (Linear Products)
(continued)
Group B - Lot by lot inspection
IL = inspection levels
AQL = Acceptable Quality Level (%)
Levels of Quality Assessment
Examination or test
IL
AQL
BS 9400
SUB-GROUP B1
Dimensions
S2
6.5
1.2.3
SUB-GROUP B2a
Solderbility
S4
4.0
1.2.6.15.1
S4
4.0
1.2.6.13
1.2.6.14.1/2
SUB-GROUP B3
Lead bending
S3
6.5
1.2.6.16.2
SUB-GROUP B6
Acceleration steady state
S4
4.0
1.2.6.9
SUB-GROUP B7
Electrical Endurance
S4
1.5
1.2.7.2.2
SUB-GROUP B2b
Change of temp
followed by sealing
Observations
Unless otherwise stated in detail specification:
attributes information for B2a, B2b, B6, B7
SUB-GROUP B8
CTR Information
Group C - Periodic inspection
IL = inspection levels
AQL = Acceptable Quality Level (%)
Levels of Quality Assessment
Examination or test
IL
AQL
BS 9400
SUB-GROUP C1
Dimensions
S2
6.5
1.2.3
S2
6.5
1.2.6.8.1
1.2.6.6
1.2.6.5
SUB-GROUP C5
Electrical Endurance
S3
4.0
1.2.7.2.2
Duration = 2000 hrs
SUB-GROUP C6
CTR Information
S3
6.5
1.1.11
Unless otherwise stated in detail spec:
attributes information for C3 & C5
SUB-GROUP C3
Vibration followed by
Shock followed by
Damp Heat Cycle
10
Observations
DOC 2624 ISS 8
BS (Linear Products)
(continued)
5.2 BS Screening Options (Linear IC’s)
CATEGORY S1
CATEGORY S2
CATEGORY S3
CATEGORY S4
100% Internal
Visual Inspection
Level A
100% Internal
Visual Inspection
Level B
100% Internal
Visual Inspection
Level B
24 Hour High
Temperature
Storage
24 Hour High
Temperature
Storage
24 Hour High
Temperature
Storage
Rapid change of
Temperature
Rapid change of
Temperature
Rapid change of
Temperature
Acceleration Test
(Direction Y1, Y2)
Acceleration Test
(Direction Y1)
Acceleration Test
(Direction Y1)
Fine & Gross
Leak Test
Fine & Gross
Leak Test
Fine & Gross Leak
Test
Test
Electrical
Characteristics
Test
Electrical
Characteristics
Test
Electrical
Characteristics
240 Hour Duration
High Temperature
Burn-In
160 Hour Duration
High Temperature
Burn-In
160 Hour Duration
High Temperature
Burn-In
Shock
Test
Electrical
Characteristics
72 Hour Duration
High Temperature
Reverse Bias
Test
Electrical
Characteristics
Test
Electrical
Characteristics
Test
Electrical
Characteristics
Test
Electrical
Characteristics
Radiographic
Tests
(Accept / reject criteria at every stage strictly as defined by the BS Specifications).
11
DOC 2624 ISS 8
6. BS and CV (Discrete Products)
6.1 BS and CV processed devices (Bipolar)
Semelab is committed to the ongoing supply of a wide range of product types. This includes
many products where the original manufacturer has ceased production, which is the case on
many discrete products originally supplied against BS specifications.
Semelab can provide ‘look-alike’ devices against most BS specifications, processing devices
as shown below. Semelab can also supply many of the old type CV devices which have been
converted into the BS system.
Product is processed to the requirements of Group A (electrical) and Group B (mechanical
and environmental) tests of BS detail device specifications. Parts processed in accordance
with these specifications are marked with the suffix ‘-O’ added to the original part number.
Screening can also be carried out against the BS sequences A,B,C,D if required
Ordering Information (example):
Part Number
Description
Marking (*)
BFT69-O
Requirements of BS9365-F005 Groups A & B
BFT69-O
BFT69-O-B
Requirements of BS9365-F005 Groups A & B
BFT69-0/B
With screening in accordance with BS sequence B
CV7xxx-0
Requirements of BS 9300 Cxxx Groups A,B
CVxxx-O
* Where space permits
12
DOC 2624 ISS 8
7. DSCC / 883B (Linear Products)
Built on Semelab’s QML Qualified Production Lines
Cage Number U3158
SEMELAB offers a range of DSCC SMD listed and 883B processed voltage regulators,
PWM’s and Control IC’s. All manufacturing is carried out on our QML qualified lines in our
Lutterworth factory to the appropriate MIL-STD-883 specifications (5005 - Processing and
5004 - Screening).
7.1 Inspection Levels for DSCC SMD Listed Devices
Method 5005: Table I Group A electrical tests for class level B
Examination or test
Quality/accept
Observations
SUB-GROUP 1
Static Tests
116/0
Tamb = 25°C
SUB-GROUP 2
Static Tests
116/0
Tamb = Tmax
SUB-GROUP 3
Static Tests
116/0
Tamb = Tmin
SUB-GROUP 4
Dynamic Tests
116/0
Tamb = 25°C
SUB-GROUP 5
Dynamic Tests
116/0
Tamb = Tmax
SUB-GROUP 6
Dynamic Tests
116/0
Tamb = Tmin
SUB-GROUP 7
Functional Tests
116/0
Tamb = 25°C
SUB-GROUP 8a
Functional Tests
116/0
Tamb = Tmax
SUB-GROUP 8b
Functional Tests
116/0
Tamb = Tmin
SUB-GROUP9
Switching tests
116/0
Tamb = 25°C
SUB-GROUP10
Switching tests
116/0
Tamb = Tmax
SUB-GROUP11
Switching tests
116/0
Tamb = Tmin
1) The specific parameters to be included for tests in each subgroup shall be as specified in the applicable acquisition
document. Where no parameters have been identified in a particular subgroup or tests within a subgroup, no group A
testing is required for that subgroup or test to satisfy group A requirements.
2) When the (sub)lot size is less than the required sample size, each and every device in the (sub)lot shall be inspected and
all failed devices removed from the (sub)lot for final acceptance of that test, subgroup, or set of tests/subgroups.
Method 5005: Table IIb Group B tests for class level B
Test
note
MIL-STD-883
method
(3)
2015
Condition
Quantity/accept or
sample size/accept
Subgroup 2
Resistant to solvents
3/0
Subgroup 3
Solderability
(4)
2003
(5)
2011
temp 245°C ± 5°C
soldering
sample size
number = 22, c = 0
Subgroup 3
Bond strength
1) Thermo-compression
2) Ultrasonic / Wedge
3) Flip-chip
4) Beam lead
1) Test Condition C or D
2) Test Condition C or D
3) Test Condition F
4) Test Condition H
sample size
number = 15, c = 0
3) Resistance to solvents testing required only on devices using inks or paints as the marking or contrast.
4) Devices submitted for solderability shall be in the same lead finish as shipped product and must have been through the
temp/time exposure of burn in except for devices which have been hot solder dipped or have lead-tin fusing after burn-in.
5) Unless otherwise specified the sample size number for condition C or D is the number of bond pulls selected from a
minimum number of 4 devices and for condition F or H is the number of dice (not bonds).
13
DOC 2624 ISS 8
DSCC / 883B (Linear Products)
(continued)
Method 5005: Table III Group C (Die related tests) for class level B
Test
MIL-STD-883
method
Condition
Quantity/accept or
sample size/accept
Subgroup 1
a) Steady-state life test
1005
b) End-point electrical
parameters
Test condition to be specified (1000
hours at 125°C or equivalent in
accordance with table 1)
sample size
number = 45, c = 0
As specified in the applicable device
specification
Method 5005: Table IV Group D (package related tests) for class level B
Test (1)
Subgroup 1 (2)
Physical Dimensions
Subgroup 2
a) Lead Integrity (3)
b) Seal - Fine & Gross leak (5)
Subgroup 3 (4)
a) Thermal Shock
b) Temp Cycle
c) Moisture resistance
d) Visual Examination
e) Seal - Fine & Gross leak
f) End Point Electricals
Subgroup 4 (4)
a) Mechanical Shock
b) Vibration, variable frequency
c) Constant Acceleration
d) Seal - Fine & Gross leak
e) Visual examination
f) End point Electricals (6)
Subgroup 5 (2)
a) Salt Atmosphere
b) Visual Examination
c) Seal - Fine & Gross leak
Subgroup 6 (2)
a) Internal water-vapour content
Subgroup 7 (2)
a) Adhesion of Lead finish (12)
Subgroup 8 (2)
a) Lid Torque
MIL-STD883 method
Condition
Quantity/accept or
sample size/accept
sample size
number = 15, c = 0
2016
2004
1014
Test Condition B (lead fatigue)
As applicable
sample size
number = 45, c = 0
1011
1010
1004
Test condition B - 15 cycles min
Test Condition C. 100 cycles min
sample size
number = 15, c = 0
1014
2002
2007
2001
1014
In accordance with visual criteria
method 1004 and 1010
As applicable
As specified in the applicable device
specification
Test condition B minimum
Test condition A minimum
Test condition E minimum (Y1 only)
sample size
number = 15, c = 0
In accordance with meth 1010 or 1101
As specified in applicable device
specification
1009
1014
Test condition A minimum
In accordance with method 1009
sample size
number = 15, c = 0
1018
5000ppm max water content at 100°C
2025
3/0 or 5/1
sample size
number = 15, c = 0
2024
5/0
1) In line monitor data may be substituted for subgroups D1,D2,D6,D7 and D8 upon approval by the qualifying activity. The
monitors shall be performed by package type and to the specified subgroup test method.
2) Electrical reject devices from the same inspection lot may be used for samples.
3) The sample size number of 45, C=0 for lead integrity shall be based on the number of leads or terminals tested and shall be
taken from a minimum of 3 devices.
4) Seal tests need only be performed on packages having leads exiting through a glass seal.
5) Devices used in subgroup 3 can be used in subgroup 4.
6) End point electrical parameters may be performed after moisture resistance and prior to seal test.
7) Sample size based on number of leads.
14
DOC 2624 ISS 8
DSCC / 883B (Linear Products)
(continued)
7.2 Screening Sequences for DSCC SMD Listed Devices
Method 5004: Table 1 Class level B screening
Screen
MIL-STD-883
method
Condition
Requirement
Internal Visual (1)
2010
Test Condition B
100%
Stabilisation Bake
1008
24hrs @ condition C minimum
100%
100%
Temperature Cycling (2)
1010
Test Condition C
Constant Acceleration
2001
Test condition E minimum
Y1 orientation only
Visual Inspection
Initial (pre-burn-in) (3)
In accordance with applicable
electrical Parameters
Burn-In Test
100%
100%
100%
device specification
1015
160 hours at 125°C minimum
100%
Interim (Post Burn-In)
In accordance with applicable
100%
Electrical Parameters
device specification
Percentage Defect Allowable
5% all lots
Final Electrical Test
a) Static tests
1) 25°C
subgroup 1 table 1 5005
2) Maximum and Minimum
rated operating temperature
subgroup 2,3 table 1 5005
In accordance with applicable
device specification
100%
100%
b) Dynamic or functional tests
1) 25°C
subgroup 4,7 table 1 5005
2) Minimum and Maximum
rated operating temperature
subgroup 5,6,8 table 1 5005
100%
100%
100%
c) Switching tests at 25°C
subgroup 9 table 1 5005
Seal (4)
1014
100%
a) Fine
b) Gross
Qualification or quality (5)
conformance inspection test
sample selection
5005
External Visual
2009
In accordance with applicable
device specification
sample
100%
1) Test samples for group B, bond strength may be selected prior to or following internal visual, prior to sealing provided all
other specification requirements are satisfied. Test method 2010 applies in full except when method 5004, alt 1 or 2 is in effect.
2) This may be replaced with thermal shock method 1111, test condition A, minimum.
3) When specified in the applicable device specification, 100% of devices shall be tested for parameters requiring deltas.
4) Fine & Gross leak tests shall be performed separately or together between constant acceleration and external visual. All
device lots having any physical processing steps performed following seal shall be retested for hermeticity and visual defects.
5) Samples shall be selected for testing in accordance with the specific device class and lot requirement of method 5005.
15
DOC 2624 ISS 8
DSCC / 883B (Linear Products)
(continued)
7.3 MIL883B Processed Integrated Services (QR214, QR215)
QR215: ‘MIL Processed /883B’ Full Quality Conformance Inspection for
Linear Integrated Circuits A and B, C and D optional)
QR214: ‘MIL Processed /883B’ Linear Integrated Circuit Component Screening
Semelab are able to supply additional non SMD listed linear products fully processed in
accordance with the MIL-STD-883B specification flow and methods. Semelab’s QR214 and
QR215 are based on MIL-STD-883E, METHOD 5005 quality conformance, inspection
requirements and METHOD 5004 screening methods.
Semelab QR215 (quality conformance) covers the control procedures for group A
(electrical), group B (environmental), group C (die related) and group D (package related)
tests. It is based on METHOD 5005 conformance procedures and MIL-STD-883E test
methods
Semelab QR214 (screening) is based on METHOD 5004 screening procedures and
MIL-STD-883E test methods.
Ordering Information:
Devices screened in accordance with Semelab QR214 and QR215 are identified using the
standard product part number with the addition of the suffix “–8QRB”.
Example: LM117H built and screened to the MIL883B flows Method 5005 and Method 5004
in accordance with QR214 and QR215 is: LM117H-8QRB
Device Marking:xxx-8QRB for products equivalent to MIL883B parts - e.g. LM117H-8QRB + SML + DC
16
DOC 2624 ISS 8
8. MIL-PRF-19500 – QR205, QR204 (Aerospace)
QR205: ‘Mil Processed’ Full Quality Conformance Inspection (MIL-PRF-19500)
QR204: ‘Mil Processed’ Discrete Component Screening (MIL-PRF-19500)
SEMELAB’s QR205 and QR204 processing specifications, in conjunction with the company’s
ISO 9001:2000 approval present a viable alternative to the American MIL approved parts
from a European manufacturer.
Semelab QR205 (quality conformance) is based on the quality conformance inspection
requirements of MIL-PRF-19500 groups A (table V), B (table VIb), C (table VII).
Semelab QR204 (screening options) is based on the screening options and requirements of
MIL-PRF-19500 (table IV).
Full details of Semelab QR205 and QR204 are included in the following pages, showing
sample sizes and test methods used.
All manufacture and processing is carried out on our approved High-Rel assembly line in our
Lutterworth factory and product is released under the company’s ISO 9001:2000 defence
standard approval.
The table below shows part number examples and corresponding processing options and
marking. The device marking will also contain the SEMELAB identifier (SML) plus the date
code where space permits.
Ordering Information: (examples)
Part Number
Description
Marking (*)
2N2369-JQR
QR205 groups A,B
2N2369-JQR
2N2369-JQRB
QR205 groups A,B
2N2369-JQRB
Screening to QR204 level B
2N2369-JQRA
QR205 groups A,B
2N2369-JQRA
Screening to QR204 level A
* Where space permits
Additional options:
Group C charge
Group C destructive electrical samples
Group C destructive mechanical samples
-GRPC
-GCDE
-GCDM
(12 pieces)
(6 pieces)
Notes:
1) All ‘Additional Options’ are chargeable and must be specified at order stage.
2) When Group C is required, additional electrical and mechanical destructive samples must be ordered.
3) All destructive samples are marked the same as other production parts unless otherwise requested.
17
DOC 2624 ISS 8
MIL-PRF-19500 – QR205, QR204 (Aerospace)
(continued)
8.1 Inspection Levels: ‘Mil Processed’ Quality Conformance (ref: MIL-PRF-19500)
QR205: Group A - Electrical Tests
Subgroup
Description
1
Visual + mechanical Inspection
2
3
* small lot conformance
LTPD
Sample*
Reject
5
45
0
DC electrical tests at 25°C
5
116
0
DC electrical tests. Hot & Cold temps as per device datasheet
30
45
0
4
AC electrical tests at 25°C
30
45
0
5
Safe Operating Area (Power Transistors)
a) DC
b) Clamped Inductive
c) Unclamped Inductive
Endpoint electrical measurements
30
45
0
The specified parameters to be included in each subgroup shall be as per the detail specification. Where no parameters are
specified in a particular subgroup or test within a subgroup, no Group A testing is required for that subgroup or test to satisfy
Group A requirements. A single sample may be used for all subgroup testing. These tests are considered non-destructive.
QR205: Group B - Short term Environmental & Endurance Tests * small lot conformance
Test
Subgroup 1
Solderability
Note
MIL-STD-750
method
Condition
Sample*
Reject
d=destructive
(1)
(3)
Resistant to solvents
1
d
2026
(minimum 3 devices)
1022
(separate samples can be used)
3 devices
4 leads
1051
No dwell required at 25°C. Test
condition C1 (45 cycles including
screening), temp extreme, ≥10m
6
0
12
0
d
Subgroup 2
Temperature Cycling
(air to air)
hermetic seal
(a) Fine Leak
Test condition H.
1071
-9
<0.01cc. max = 5 x 10 atm cc/s,
-8
(b) Gross leak
>0.01cc. max = 1 x 10 atm cc/s
Electrical Measurements
Subgroup 3 & 4
Steady-state operation life
or
Intermittent operation life
or
Blocking life
Electrical Measurements
(4)
Bond Strength
(6)
Internal visual design
verification
Subgroup 5
Thermal Resistance
1027
340hrs at specified bias
conditions
1037
-
(5,6)
2037
As specified
(3 devices minimum)
11 wires
d
0
d
2075
Visual criteria in accordance with
qualified design.
3
3131
6
0
3101
For Transistors
For Diodes
1032
340hrs high temperature storage
12
0
Subgroup 6
High temperature life
(non operating)
Electrical Measurements
As specified
(Minimum qty of destructive samples required is 6.
(Full notes for numbered references are at the end of group C table)
18
DOC 2624 ISS 8
MIL-PRF-19500 – QR205, QR204 (Aerospace)
(continued)
QR205: Group C - Periodic Inspection (chargeable option on request) * small lot conformance
Test
Note MIL-STD-750
method
Condition
Sample *
Reject
d=destructive
Subgroup 1
2066
Dimensions per case outline specified
6
0
Thermal shock
(glass strain)
1056
Test condition A, except for devices
> 10W at T=25 which is condition B
6
d
0
Temperature Cycling
(air to air)
1051
Test condition C or max stg temp,
whichever is less (25 cycles)
Shock
2016
Non-operating, 1500G, 0.5ms,
5 blows in each orientation, X1, Y1, Z1
Vibration
(variable frequency)
2056
Constant acceleration
2006
6
0
Physical dimensions
Subgroup 2 & 3
Hermetic Seal
1 minute min. in X1,Y1,Z1 orientation Y1
at 20000G min except at 10000G min if
device ≥15W at TC=25°C
Test condition H.
(a) Fine Leak
1071
-9
<0.01cc. max = 5 x 10 atm cc/s,
-8
>0.01cc. max = 1 x 10 atm cc/s
(b) Gross leak
b) Test condition C
Moisture resistance
1021
Omit initial conditioning
Terminal strength
2036
As specified
Electrical Measurements
Subgroup 4
As specified
(2)
1041
Salt atmosphere
(corrosion)
Covered by MIL883 ongoing
group D programme
Subgroup 5
Thermal Resistance
Subgroup 6
Steady-state op life
or
Intermittent operation life
or
Blocking life
3131
For Transistors
3101
For Diodes
1026
1000hrs at max operating junction temp
1036
As specified
(4)
d
12
0
Electrical Measurements
Subgroup 7
Internal Gas Analysis
(2)
Covered by MIL883B ongoing
Group D programme
(Quantity of Destructive samples that must be ordered is 18 devices)
1) Electrical reject devices from the same inspection lot may be used for all subgroups when electrical end point
measurements are not required.
2) Group C subgroup 4 and 7 are covered by MIL883B ongoing group D programme. These are not available on specific
batches under QR205. If required, see QR217
3) The LTPD for solderability test applies to the number of leads inspected except in no case shall less than three devices be
used to provide the number of leads required.
4) If a given inspection lot undergoing Group B inspection has been selected to satisfy Group C inspection requirements, the
340 hour life test may be continued to 1000 hours in order to satisfy the Group C life test requirements. In such cases,
either the 340 hour end point measurements must be made as a basis for Group B lot acceptance or the 1000 hour end
point measurement shall be used as the basis for both Group B and Group C acceptance.
5) Internal Design Verification may be omitted if the devices have been manufactured by Semelab as sample pre-cap visual
inspection will have been performed.
6) Samples from Subgroup 1 can be used.
19
DOC 2624 ISS 8
MIL-PRF-19500 – QR205, QR204 (Aerospace)
(continued)
8.2 Screening Sequences: ‘Mil Processed’ Products (MIL-PRF-19500)
QR204: Discrete Component Screening (with reference to MIL-STD-750)
Description
MIL-STD-750
method
1
Internal Visual
(Precap) Inspection
2069
2070
2072
2
High temperature
stabilisation bake
1032
3
Temperature
Cycling
4
Constant
acceleration
8
Device Serialisation
9
Interim electrical
10
11
Conditions
JQR-A
JQR-B
100%
N/A
24 hrs min at rated maximum
storage temperature
100%
100%
1051
20 cycles at -55°C to +175°C or
max storage temp (whichever is
lower) with a minimum cycle time of
16 minutes
100%
100%
2006
20,000G force in Y1axis for 1 min
duration (see note 2)
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
(for drift calculations only)
High temperature
reverse bias
a) Bipolar
1039
Test Condition A
b) Power MOSFET
1042
Test Condition B
c) Diodes
1038
Test Condition A
Interim electrical
Group A (read & record)
Power burn-in
a) Bipolar
1039
Test Condition B - 160 hrs min
b) Power MOSFET
1042
Test Condition A - 160 hrs min
c) Diodes
1038
Test Condition B - 96 hrs min
d) Case mounted
1038
Test Condition A – 48 hrs min
12
Rectifiers
13
Final electrical
Group A
Read & Record +Drift check (1)
Hermeticity
1071
Test condition H.
-9
a) Fine
<0.01cc. max = 5 x 10 atm cc/s,
14
-8
>0.01cc. max = 1 x 10 atm cc/s
b) Gross
1071
Condition C
Notes:
1) Group A end point tests are DC functional / parametric at 25°C (subgroup 2) of QR205.
2) 10000G force for devices with power rating >10 watts at Tc=25°C.
3) PDA (percentage defects allowable) is 10% between steps 9 & 11 and 11 & 13.
20
DOC 2624 ISS 8
9. MIL-PRF-19500 – QR216, QR217 (Space)
9.1 Space Level Processed Discrete Semiconductors (MIL-PRF-19500)
QR217: ‘Space Level’ Full Quality Conformance Inspection.
QR216: ‘Space Level’ Discrete Component Screening
SEMELAB’s QR217 and QR216 processing specifications, in conjunction with the company’s
ISO 9001:2000 approval present a viable alternative to American MIL-PRF-19500 space
level parts supplied from a European manufacturer.
QR217 (quality conformance) is based on the quality conformance inspection requirements
of MIL-PRF-19500 groups A (table V), B (table VIa), C (table VII) and also ESA / ESCC 5000
(chart F4) lot validation tests.
QR216 (screening) is based on the screening requirements of MIL-PRF-19500 (table IV) and
also ESA /ESCC 5000 (chart F3). Details of QR217 and QR216 are included in the following
pages.
All manufacture and processing is carried out on our approved High-Rel assembly line in
Lutterworth and product is released under our ISO 9001:2000 defence standard approval.
The ‘standard’ JQRS part is processed to the Semelab data sheet, screened to QR216 and
has conformance testing to Q217 groups A and B. Available options and the associated part
number extensions are shown below. These are chargeable and must be specified at order
stage. The extensions on the Semelab part numbers used reflect these additional items.
Ordering Information: (example)
Part Number
Description
2N2369-JQRS
QR217 groups A,B
Marking (*)
Screening to QR216
2N2369-JQRS
* Where space permits
Additional options:
Customer Pre-Cap Visual Inspection
Customer Buy-Off visit
Data Pack
-CVP
-CVB
-DA
Group B charge
Group B destructive mechanical samples
-GRPB
-GBDM
(12 pieces)
Group C charge
Group C destructive electrical samples
Group C destructive mechanical samples
-GRPC
-GCDE
-GCDM
(12 pieces)
(6 pieces)
Solderability Samples
Scanning Electron Microscopy
Radiography (X-ray)
Total Dose Radiation Test
-SS
-SEM
-XRAY
-RAD
Notes:
1) All ‘Additional Options’ are chargeable and must be specified at order stage.
2) When Group B or C is required, additional electrical and mechanical destructive samples must be ordered
3) All destructive samples are marked the same as other production parts unless otherwise requested.
21
DOC 2624 ISS 8
MIL-PRF-19500 – QR216, QR217 (Space)
(continued)
9.2 QR217 Inspection Levels for ‘Space Level Processed’ Products
QR217: Group A - Electrical Tests
Subgroup
Description
1
2
* small lot conformance
Sample*
Reject
Visual + mechanical Inspection
20
0
DC electrical tests at 25°C
20
0
3
DC electrical tests. Hot & Cold temps as per device datasheet
45
0
4
AC electrical tests at 25°C
45
0
5
Safe Operating Area (Power Transistors)
8
0
Endpoint electrical measurements
The specified parameters to be included in each subgroup shall be as per Semelab Data Sheet. Where no parameters are
specified in a particular subgroup or test within a subgroup, no Group A testing is required for that subgroup or test to satisfy
Group A requirements. A single sample may be used for all subgroup testing. These tests are considered non-destructive.
QR217: Group B - Short term Environmental & Endurance Tests * small lot conformance
Test
note
MIL-STD-750
method
Condition
Sample*
Reject
d=destructive
Subgroup 1
Physical Dimensions
2066
As per specification
8
0
2026
(minimum 3 devices)
6 leads
0
1022
(Separate samples can be used)
d
1056
Test condition B (25 cycles),
(glass diodes only)
1051
Test condition C or max stg temp,
whichever is less. 100 cycles.
Subgroup 2
Solderability
Resistant to solvents
(3)
(3)
d
6 devices
Subgroup 3
Thermal shock
(liquid to liquid)
Temperature Cycling
(air to air)
Hermetic seal
(a) Fine Leak
d
0
d
0
6
Test condition H.
1071
-9
<0.01cc. max = 5 x 10 atm cc/s,
-8
(b) Gross leak
>0.01cc. max = 1 x 10 atm cc/s
Electrical Measurements
Internal visual design
verification
(4)
bond strength
Die Shear
Subgroup 4 / 5
Steady-state operation life
or
Intermittent operation life
or
Blocking life
Electrical Measurements
Subgroup 6
Thermal resistance
2075
Visual criteria in accordance with
qualified design.
2037
(minimum 6 devices)
6
12 wires
d
d
0
2017
Parts from bond strength (min=6)
6
0
1027
340hrs at specified bias conditions
12
0
For Transistors
For Diodes
6
0
340hrs high temperature storage
As specified
12
0
(5)
1037
As specified
3131
3101
Subgroup 7
High temperature life
(non operating)
1032
Electrical Measurements
(Minimum quantity of destructive samples required is 12 pieces)
(Full notes for numbered references are at the end of group C table)
22
DOC 2624 ISS 8
MIL-PRF-19500 – QR216, QR217 (Space)
(continued)
QR217: Group C - Periodic Inspection (chargeable option on request ) * small lot conformance
Test
note MIL-STD-750
method
Condition
Sample *
Reject
d=destructive
Subgroup 1
2066
Dimensions per case outline specified
6
0
Thermal shock
(glass strain)
1056
Test condition B (25 cycles),
6
d
0
Temperature Cycling
(air to air)
1051
Test condition C or max storage
temperature, whichever is less
(45 cycles including screening)
Shock
2016
Non-operating, 1500G, 0.5ms,
5 blows in each orientation, X1, Y1, Z1
(Y1 only for axial glass diodes)
Vibration
(variable frequency)
2056
Constant acceleration
2006
Physical dimensions
Subgroup 2 & 3
Hermetic Seal
1 minute min. in X1,Y1,Z1
at 20000G min except at 10000G min
if device ≥10W at TC=25°C
Test condition H.
(a) Fine Leak
1071
-9
<0.01cc. max = 5 x 10 atm cc/s,
-8
>0.01cc. max = 1 x 10 atm cc/s
(b) Gross leak
b) Test condition C
Moisture resistance
1021
Omit initial conditioning
Terminal strength
2036
As specified
Electrical Measurements
Subgroup 4
As specified
(2)
see (2)
1041
Salt atmosphere
(corrosion)
Covered by MIL883 ongoing
6
d
0
6
0
group D programme
Subgroup 5
Thermal Resistance
Subgroup 6
Steady-state op life
or
Intermittent operation life
or
Blocking life
3131
For Transistors
3101
For Diodes
1026
1000hrs at max operating junction temp
1036
As specified
(5)
d
12
0
Electrical Measurements
Subgroup 7
Internal Gas Analysis
(2)
see (2)
Covered by MIL883B ongoing
Group D programme
d
0
d
1
3
5
(Minimum quantity of destructive samples required is 18 pieces)
1)
2)
3)
4)
5)
6)
Individual subgroups may be performed on representative parts from the same package family.
Group C subgroup 4 and 7 are covered by MIL883B ongoing group D programme. If customers require these
subgroups to be done on the specific batch being covered, an additional ‘Grp C extra’ charge applies and an
additional 11 destructive samples must be ordered. This must be specified at order stage.
Electrical reject devices from the same inspection lot may be used for all subgroups when electrical end point
measurements are not required.
Post burn-in electrical rejects may be used.
If a given inspection lot undergoing Group B inspection has been selected to satisfy Grp C inspection requirements,
the 340 hour life test may be continued to 1000 hrs to satisfy the Group C life test requirements. In such cases, either
the 340 hour end point measurements must be made as a basis for Group B lot acceptance or the 1000 hour end
point measurement shall be used as the basis for both Group B and Group C acceptance.
Internal Visual Design Verification may be omitted if the devices have been manufactured by Semelab as sample
pre-cap visual inspection will have been performed.
23
DOC 2624 ISS 8
MIL-PRF-19500 – QR216, QR217 (Space)
(continued)
9.3 QR216: ‘Space Level’ Discrete Component Screening
QR216: Discrete Component Screening (with reference to MIL-STD-750)
MIL-STD750 method
Description
JQR-S
2069, 2070
2072
1
Internal Visual
Inspection
2
Customer Pre Cap Visual
Inspection
2069, 2070
2072
Customer specified option (chargeable)
100%
3
High temperature
stabilisation bake
1032
24 hrs min at rated maximum storage
temperature
100%
4
Temperature Cycling
1051
20 cycles at -55°C to +175°C or max storage
temp (whichever is lower) with minimum 10
minutes dwell time
100%
5
Constant acceleration
2006
20,000G force in Y1axis for 1 min duration
(see note 2)
100%
6
Particle Impact Noise
Detection (PIND)
2052
(full yielded quantity)
100%
7
Device Serialisation
Device serialisation is carried through to shipping.
8
Interim electrical
Read & Record
9
10
(Pre-cap)
Conditions
100%
High temperature reverse
bias
a) Bipolar
1039
Test Condition A
b) Power MOSFET
1042
Test Condition B
c) Diodes
1038
Test Condition A
Interim electrical (note 3)
100%
100%
Read & Record, Drift Check
100%
Power burn-in
a) Bipolar
1039
Test Condition B - 240 hrs min
b) Power MOSFET
1042
Test Condition A - 240 hrs min
c) Diodes
1038
Test Condition B - 240 hrs min (4)
11
12
Final electricals (note 3)
13
a) Hermeticity – Fine
b) Hermeticity - Gross
100%
Read & Record, Drift check (1)
100%
1071
Test condition H.
100%
1071
<0.01cc. max = 5 x 10 atm cc/s,
-9
100%
-8
>0.01cc. max = 1 x 10 atm cc/s
Condition C
14
Radiographic tests (X-Ray)
2076
15
External Visual Inspection
2071
Notes:
1)
2)
3)
4)
(May be performed at any time after serialization)
100%
QR217 Group A subgroups 2 and 3 end point tests as per device detail spec.
10000G force for devices with power rating >10 watts at Tc=25°C.
PDA (percentage defects allowable) is 5% between steps 8 & 10 and 10 & 12.
Zener diodes shall be subjected to high temperature reverse bias at 80 - 85 percent of nominal VZ for VZ > 10 V.
Omit test for devices with VZ ≤ 10 V. For JQRS case mounted rectifiers condition A is required.
24
DOC 2624 ISS 8
10. ESA/ESCC - Space Level Product
Semelab’s Space Quality Level Products are based on the testing procedures specified in
the generic ESCC 5000 issue 3 and in the corresponding Detail Specifications.
All manufacture and processing is carried out on our approved High-Rel assembly line in our
Lutterworth factory and product is released under our ISO 9001:2000 defence standard
approval.
The table below shows the additional options which may be required by the customer. All
items must be agreed and specified at order stage.
The following pages show the generic chart F2 (component lot manufacturing), chart F3
(screening) and chart F4 (Validation) requirements.
Additional options:
Customer Pre-Cap Visual Inspection
Customer Buy-Off visit
Data Pack
-CVP
-CVB
-DA
Lot Validation Testing (subgroup 1) charge
LVT1 destructive samples (electrical)
LVT1 destructive samples (mechanical)
-LVT1
-L1DE
-L1DM
(normally 15 pieces)
(normally 15 pieces)
Lot Validation Testing (subgroup 2) charge
LVT2 destructive samples (electrical)
-LVT2
-L2D
(normally 15 pieces)
Lot Validation Testing (subgroup 3) charge
LVT3 destructive samples (mechanical)
-LVT3
(normally 5 pieces)
Scanning Electron Microscopy (SEM)
Radiography (X-ray)
Total Dose Radiation tests
-SEM
-XRAY
-RAD
Notes:
1) All ‘Additional Options’ must be specified at order stage
2) All ‘Additional Options’ are chargeable
3) All destructive samples are marked the same as other production parts unless otherwise requested.
25
DOC 2624 ISS 8
ESA/ESCC (Space Level Flow)
(continued)
10.1 Chart F2 - Production Control (ESCC 5000 issue 3)
Component Lot manufacturing
Wafer lot Acceptance
para 5.3.1
Process monitoring Review
para 5.3.2
SEM Inspection
(1,3)
para 5.3.3
Total Dose Rad Testing
(1,4)
Special In - Process controls
Para 5.2.1
Internal Visual inspection (Pre-cap Inspection)
Para 5.2.1
Bond Strength(Pre-cap Inspection)
(1)
Para 5.2.1
Die Shear(Pre-cap Inspection)
(1)
Para 5.2.1
Encapsulation (Pre-cap Inspection)
(1)
Para 5.2.1
Dimension check
(1)
Para 5.2.3
Weight
(2)
To Chart F3 (Screening)
Notes: 1)
2)
3)
4)
Performed on a sample basis.
Guaranteed but not tested.
If specified in the detail specification.
If specified in the detail specification and required in the Purchase Order.
26
DOC 2624 ISS 8
10.2 ESA/ESCC - Chart F3 Screening (ESCC 5000 issue 3)
Components from Production Control
para 8.5
High Temperature Stabilisation Bake
Electrical Test
para 8.6.1
(11)
Temperature Cycling
Acceleration
(10)
para 8.7
Particle Impact Noise Detection (PIND)
para 8.22
Verification of Safe Operating Area
para 8.9.1
Electrical Measurements, Serialisation and Parameter
Drift Values (Initial Measurements)
(1)
para 8.20
High Temperature Reverse Bias Burn-In
(2)
para 8.9.1
Parameter Drift Values
HTRB Final and Power Burn-In Initial Measurements
(4)
para 8.21
Power Burn-In
(2)
para 8.9.1
Parameter Drift Values (Final Measurements)
(4)
para 8.9.2
High and Low Temperature Electrical Measurements
(2,3)
(4,5)
Hot Solder Dip (if applicable)
(6)
para 8.3
Radiographic Inspection
(9)
para 8.8.1&2
Seal (Fine & Gross Leak)
para 8.9.3
Room Temp Electrical Measurements (including AC)
para 6.4.1
Check for Lot Failure
para 8.10
External Visual Inspection
para 8.16
Solderability
(4,7)
(8)
(4,5)
To Chart F4 (Validation Testing)
Notes:
1)
2)
3)
4)
5)
6)
7)
8)
All components shall be serialised prior to Initial Electrical Measurement.
If specified in detail spec.
Can be performed at any time prior to initial measurements of Parametric Drift values.
The Lot Failure criteria of paragraph 6.4 applies to this test.
Performed on a sample basis.
Can be performed at any time prior to Room Temp Electrical Measurements during screening (prior to Seal test).
Measurements of parametric Drift Values need not be repeated in Room Temperature Electrical measurements.
Check for Lot Failure shall take into account all electrical parameter failures that may occur during screening.
tests in accordance with paragraph 8.9.1, 8.9.2, 8.9.3 subsequent to HTRB Burn-In.
9) Radiographic Inspection may be performed at any point during Screening Tests.
10) Not specified in ESCC 5000 iss 3, but performed by Semelab to MIL-STD-750 method 2006.
11) Not specified in ESCC 5000 iss 3, but performed by Semelab as a process monitor.
27
DOC 2624 ISS 8
ESA/ESCC (Space Level Flow)
(continued)
10.3 Chart F4 - Validation Testing (ESCC Generic Specification 5000 issue 3)
Components for Validation
LVT 1
(Subgroup 1)
LVT 2
(Subgroup 2)
LVT 3
(Subgroup 3)
Mechanical & Environmental
Endurance
Assembly Capability
5 Components
15 Components
15 Components
15 Components
Mechanical Shock
para 8.11
Thermal Shock (2)
para 8.14
Vibration
para 8.12
Temp Cycling (3)
para 8.6.2
Operating Life (4)
2000 hours
data points:
0,1000, 2000 hrs
para 8.19
Constant
Acceleration
para 8.13
Moisture
Resistance
para 8.15
Immediate & End
Point electrical
Measurements
para 8.9.4
Internal Visual
Inspection
para 8.1
Seal
para 8.8.1 & 8.8.2
Seal
para 8.8.1 & 8.8.2
Seal
para 8.8.1 & 8.8.2
Bond Strength
para 8.2.1
Immediate & End
Point electrical
Measurements
para 8.9.4
Immediate & End
Point electrical
Measurements
para 8.9.4
External Visual
Inspection
para 8.10
Die Shear
para 8.2.2
External Visual
Inspection
para 8.10
External Visual
Inspection
para 8.10
Permanence
of Marking
para 8.17
LVT 1 (Subgroup 1)
Lot Validation
LVT 2 (Subgroup 2)
Lot Validation
Terminal Strength
para 8.18
LVT 3 (Subgroup 3)
Lot Validation
Notes:
1)
2)
3)
4)
ESCC 5000 iss 3 table F4 - Qualification & Periodic Testing becomes ‘Validation Testing’ for non qualified parts.
Only applicable to axial diodes.
Not applicable to axial lead glass diodes.
Variance in Test method based on product type.
Ordering Information:
1)
2)
3)
4)
Order for Subgroup 1 (includes subgroups 2 & 3) requires order for 50 (30+15+5) destructive samples.
Order for Subgroup 2 (includes subgroup 3) requires order for 20 (15+5) destructive samples.
Order for Subgroup 3 requires order for 5 destructive samples.
Other Ordering Options are available - please contact Semelab Sales.
28
DOC 2624 ISS 8
11. Screening & Approval Comparison Tables
11.1 Comparison of Space Level Screening Options
Space Level Flow Comparison Table
GENERIC
Screening Stage:
QR216
ESCC
JANS*
JQRS
•
•
•
OPT
OPT
OPT
24 hrs
24 hrs
24hrs
Temperature cycling
20 cycles
20 cycles
20
cycles
Thermal impedance
OPT
-
Serialization
•
•
•
•
•
•
•
•
•
•
•
Interim Electrical Measurements
-
-
-
HTRB
•
•
•
•
•
•
Electrical Measurements
-
-
-
Parametric Drift measurements (Read and Record / Drift)
•
•
•
min 168 hrs
max 264 hrs
240 hrs
240hrs
-
-
-
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Pre-cap Visual
Customer pre-cap Visual
High Temp Storage (Stabilization Bake)
■
Constant Acceleration
PIND
Fine/Gross Leak
Interim Electrical Measurements (Read and Record / Drift)
Burn-In
Electrical Measurements
Parameter Drift Measurements (Read and Record)
PDA Calculations
Read and Record Test Data
Other Electrical Parameters (Temp, Dynamic)
Fine/Gross Leak
Radiography
External Visual Inspection
*JANS part not available from Semelab.
Notes:
if specified in detail specification.
■ not specified in ESCC 5000 iss 3, but performed by Semelab.
29
DOC 2624 ISS 8
Screening & Approval Comparison Tables
11.2 Comparison of Space Level die lot approval procedures.
The table below shows a comparison of operations carried out for die approval within the
generic approval systems (MIL-PRF-19500 space level and ESA / ESCC 5000. It must be
noted that SEM and RHA total dose evaluation are options which must be specified if
required carry an additional charge
Space Level/ Die Lot Acceptance Table
GENERIC
Die Lot Acceptance
SML
ESCC
JANS
JQR-S
Selected Wafer
•
•
•
Probe Test (100%)
•
•
•
Glassivation / Metalisation Inspection
•
•
•
Visual Inspection (100%)
•
•
•
Sample Assembly (10 pcs)
•
•
•
Stabilization
•
•
•
Temperature Cycling
•
•
•
Electrical Test (read/record)
•
•
•
HTRB
•
•
•
Electrical Test (read/record)
•
•
•
Steady State Life (1000 hrs)
•
•
•
Electrical Test (read/record)
•
•
•
Wire Bond Evaluation
•
•
•
Die Shear Evaluation
•
•
•
SEM
OPT
OPT
OPT
RHA Total Dose Evaluation
OPT
OPT
OPT
30
DOC 2624 ISS 8
Screening & Approval Comparison Tables
11.3 Comparison of High-Rel Screening Options (Discrete Devices)
The table below shows the comparison of screening options available within the CECC, BS
and MIL approvals. Comparison is also shown with Semelab’s in-house QR204 options.
CECC / QR209
•
•
•
B
•
•
•
•
10
10
cycles cycles
5
5
5
cycles cycles cycles
Temperature Cycle
A
C
D
•
JAN*
TX
High Temp Storage
D
MIL
JAN*
TXV
•
C
JQRB
Pre-cap Visual
B
QR204
JQRA
A
BS 9300
•
•
•
•
•
•
10
cycles
20
cycles
20
cycles
20
cycles
20
cycles
•
•
•
•
•
•
•
•
•
•
Fine Leak test
•
•
•
•
•
•
•
•
•
•
Gross Leak Test
•
•
•
•
•
•
•
•
•
•
±
±
±
±
•
•
•
•
±
±
±
±
Constant Acceleration
Particle impact noise
detection (PIND)
Device Serialisation
•
Variables Electrical test
•
•
•
•
•
168
72
48
160
72
48
48
hrs∗
hrs∗
hrs∗
hrs∗
hrs∗
hrs∗
hrs∗
Attributes Electrical tests
Burn-In (HTRB)
•
Variables Electrical test
•
•
•
•
168
72
48
160
72
48
48
160
160
160
160
hrs∗
hrs∗
hrs∗
hrs∗
hrs∗
hrs∗
hrs∗
hrs
hrs
hrs
hrs
±
±
±
±
•
•
•
•
Attributes Electrical tests
Burn-In (Power)
•
Variables Electrical test
Attributes Electrical tests
•
•
•
•
•
•
•
•
Radiographic tests
•
Test Performed
±
Test Performed if required by device detail specification
24 hours for PNP devices. 48 hours for NPN devices
∗
High Temp Reverse Bias for Case rated devices
Power Burn-in for Ambient rated Devices
CECC / QR209
: Screening carried out in accordance with CECC 50000 Appendix 6
BS
: Screening carried out in accordance with BS9300 section 1.2.10
QR216
: Screening carried out in accordance with Semelab QR216
QR204
: Screening carried out in accordance with Semelab QR204
MIL
: Screening carried out in accordance with MIL-PRF-19500 (Table 2)
* full JANTX, JANTXV not available from Semelab
31
DOC 2624 ISS 8