Data Sheets - Skyworks Solutions, Inc.

PRELIMINARY DATA SHEET
SKY13448-001: 0.1 – 3.0 GHz SPDT High Power Switch
(Single Bit Control) in a WLCSP Package
Applications
• LTE TDD/FDD transmit/receive
• GSM transmit
• Embedded modules
Features
• Broadband frequency range: 0.1 to 3.0 GHz
• Low insertion loss: 0.5 dB @ 2.7 GHz
• High isolation: 25 dB up to 2.7 GHz
• No external DC blocking capacitors required
• Single GPIO control line with VDD voltage regulator:
− VCTL = 1.65 to 2.70 V
− VDD = 2.45 to 3.00 V
• Small, 8-bump WLCSP, 200 μm diameter, 400 μm pitch (1.1 x
1.1 x 0.36 mm) package (MSL1, 260 °C per JEDEC J-STD-020)
Figure 1. SKY13448-001 Block Diagram
Description
The SKY13448-001 is a Single-Pole, Double-Throw (SPDT)
LTE/WCDMA/GSM transmit switch. Switching is controlled by an
integrated GPIO interface with a single control pin. Depending on
the logic voltage level applied to the control pin, the antenna port
is connected to one of the switched RF outputs (RF1 or RF2)
through a low insertion loss path, while the path between the
antenna port and the other RF port is in a high isolation state.
No external DC blocking capacitors are required as long as no DC
voltage is applied on any RF path.
The SKY13448-001 is provided in a compact 8-bump,
1.1 x 1.1 x 0.36 mm Wafer Level Chip Scale Package (WLCSP)
that meets requirements for board-level assembly. Bump
diameters are 200 microns with a minimum bump pitch of
400 microns.
A functional block diagram is shown in Figure 1. The pin
configuration and package are shown in Figure 2. Signal pin
assignments and functional pin descriptions are provided in
Table 1.
Figure 2. SKY13448-001 Pinout
(Top View, Bumps Facing Down)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201948C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 22, 2013
1
PRELIMINARY DATA SHEET • SKY13448-001 SPDT SWITCH
Table 1. SKY13448-001 Signal Descriptions
Pin #
Name
Description
Pin #
Name
Description
1
VDD
Supply voltage
5
RF1
RF I/O. Throw 1 of the switch.
2
V1
Digital control input
6
GND
Ground
3
GND
Ground
7
ANT
Antenna
4
RF2
RF I/O. Throw 2 of the switch.
8
GND
Ground
Table 2. SKY13448-001 Absolute Maximum Ratings
Parameter
Symbol
Minimum
Maximum
Units
Supply voltage
VDD
2.4
3.5
V
Digital control voltage
VCTL
–0.5
+3.0
V
RF input power
PIN
+39
dBm
GSM RF input power:
Low band
High band
PIN
+36
+34
dBm
dBm
WCDMA/CDMA2000/LTE TDD/FDD RF input power at ANT port
PIN
+26
dBm
Supply ripple
VPP
20
mVpp
Operating temperature
TOP
–35
+90
°C
Storage temperature
TSTG
–55
+150
°C
Electrostatic Discharge:
Human Body Model (HBM), Class 1C
Machine Model (MM), Class A
ESD
1000
100
V
V
Note:
Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY13448-001 are provided
in Table 2. Electrical specifications are provided in Tables 3
through 7.
The state of the SKY13448-001 is determined by the logic
provided in Table 8.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
January 22, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201948C
PRELIMINARY DATA SHEET • SKY13448-001 SPDT SWITCH
Table 3. SKY13448-001 Electrical Specifications (1 of 2) (Note 1)
(VDD = 2.85 V, TOP = +25 °C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
(Note 2)
Min
Typical
Max
Units
2.45
2.65
3.00
V
0
+1.65
0
+1.80
+0.45
+2.70
V
V
10
μA
DC Specifications
Supply voltage
VDD
Control voltage:
Low
High
VCTL_L
VCTL_H
Current on V1 pin
I_CTL
Supply current
IDD
VDD = 2.65 V, V1 =
VCTL_H
DC supply turn-on/turn-off time
tON
Measured from 50% of
final VDD supply voltage to
final RF power ± 1 dB
20
μs
RF path switching time
tSW
From one active state to
another active state
transition, measured from
50% of final control
voltage to final RF input
power ± 1 dB
2
μs
IL
0.8 to 1.0 GHz
0.8 to 1.0 GHz (ETC)
1.0 to 2.2 GHz
1.0 to 2.2 GHz (ETC)
2.2 to 2.7 GHz
2.2 to 2.7 GHz (ETC)
PIN = +35 dBm
μA
35
RF Specifications
Insertion loss (RF1 or RF2 to ANT pin)
Noise Figure (RF1 or RF2 to ANT pin)
NF
0.8 to 1.0 GHz (ETC)
1.0 to 2.2 GHz (ETC)
2.2 to 2.7 GHz (ETC)
Isolation
ISO
0.8 to 1.0 GHz (ETC)
1.0 to 2.2 GHz (ETC)
2.2 to 2.7 GHz (ETC)
Voltage Standing Wave Ratio, all ports
VSWR
Referenced to 50 Ω,
0.8 to 6.0 GHz
0.35
0.70
dB
dB
dB
dB
dB
dB
0.55
0.60
0.70
dB
dB
dB
0.55
0.40
0.60
0.50
32
27
25
37
30
27
1.15:1
dB
dB
db
1.3:1
–
Large Signal Specifications
LTE/WCDMA harmonics
(RF1 or RF2 to ANT pin)
fo = 815 to 915 MHz,
PIN = +24 dBm,
VSWR = 2.5:1:
3rd harmonics
–80
dBm
All other harmonics up to
12.75 GHz
–65
dBm
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201948C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 22, 2013
3
PRELIMINARY DATA SHEET • SKY13448-001 SPDT SWITCH
Table 3. SKY13448-001 Electrical Specifications (2 of 2) (Note 1)
(VDD = 2.85 V, TOP = +25 °C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted)
Parameter
Symbol
Test Condition
(Note 2)
Min
Typical
Max
Units
fo = 824 to 915 MHz,
PIN = +34 dBm, load
VSWR = 2.5:1, all other
harmonics up to
12.75 GHz
–50
–45
dBm
fo = 1710 to 1910 MHz,
PIN = +31 dBm, load
VSWR = 2.5:1, all other
harmonics up to
12.75 GHz
–50
–45
dBm
Large Signal Specifications (continued)
GSM harmonics (RF1 or RF2 to ANT pin):
Low band
High band
rd
3 Order Intermodulation Distortion
2nd Order Intermodulation Distortion
IMD3
IMD2
CW carrier = +20 dBm;
Bands 1, 2, 3, 5, 8, CW
blocker on ANT port with
PIN = –15 dBm (see
Table 4 for carrier and
interferer frequencies)
–110
dBm
CW carrier = +24 dBm;
Bands 1 & 2, WLAN CW
blocker = –20 dBm (see
Table 5 for carrier and
interferer frequencies)
–100
dBm
CW carrier = +23 dBm;
Band 7, WLAN CW blocker
= –5 dBm (see Table 5 for
carrier and interferer
frequencies)
–110
dBm
fTX: CW carrier =
+20 dBm, Bands 1, 2, 3,
5, 8, CW blocker on ANT
port with
PIN = –15 dBm (see
Table 6 for carrier and
interferer frequencies)
–100
dBm
fTX: CW carrier =
+24 dBm; bands 5 & 8,
WLAN CW blocker on ANT
port with
PIN = 0 dBm (see Table 7
for carrier and interferer
frequencies)
–100
dBm
fTX: CW carrier =
+23 dBm; band 7, WLAN
CW blocker on ANT port =
–30 dBm (see Table 7 for
carrier and interferer
frequencies)
–110
dBm
Note 1: Performance is guaranteed only under the conditions listed in this Table.
Note 2: ETC = Extreme Test Conditions (VDD = 2.45 V to 3.00 V and TOP = –20 °C to +85 °C)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
January 22, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201948C
PRELIMINARY DATA SHEET • SKY13448-001 SPDT SWITCH
Table 4. 3rd Order Intermodulation Distortion Frequencies, No WLAN Blocker
fBLOCK 1
(MHz)
fTX
(MHz)
IMD3 Band
fBLOCK 3
(MHz)
fBLOCK 2
(MHz)
Minimum
Maximum
Minimum
Maximum
Minimum
Maximum
Band 1
1920
1980
1730
1790
95.0
5950
6130
Band 2
1850
1910
1770
1830
40.0
5630
5810
Band 3
1710
1785
1615
1690
47.5
5225
5450
Band 5
824
849
779
804
22.5
2517
2592
Band 8
880
915
835
870
22.5
2685
2790
Table 5. 3rd Order Intermodulation Distortion Frequencies, WLAN Blocker
fBLOCK 1
(MHz)
fTX
(MHz)
IMD3 WLAN
Minimum
Maximum
Minimum
Maximum
Band 1 (measured at frequencies where 2fTX – fBLOCK = 1575 MHz,
PBLOCK = –20 dBm, and PTX = +24 dBm)
1920
1980
5150
5850
Band 2 (measured at frequencies where 2fTX – fBLOCK = 1575 MHz,
PBLOCK = –20 dBm, and PTX = +24 dBm)
1850
1910
5150
5850
Band 7 (measured at frequencies where 2620 MHz < 2fTX – fBLOCK <
2690 MHz, PBLOCK = –5 dBm, and PTX = +23 dBm)
2500
2570
2400
2485
Table 6. 2nd Order Intermodulation Distortion Frequencies, No WLAN Blocker
fTX
(MHz)
IMD2 Band
Minimum
Maximum
Band 1
1920
1980
Band 2
1850
Band 3
1710
fBLOCK 1 Minimum
(MHz)
fBLOCK 2
(MHz)
Minimum
Maximum
190
3650
3770
1910
80
3620
3740
1785
95
3325
3475
Band 5
824
849
45
1603
1653
Band 7
2500
2570
120
4880
5020
Band 8
880
915
45
1715
1785
Band 10
1710
1770
400
3020
3140
Table 7. 2nd Order Intermodulation Distortion Frequencies, WLAN Blocker
fBLOCK 1
(MHz)
fTX
(MHz)
IMD3 WLAN
Minimum
Maximum
Minimum
Maximum
Band 5 (WLAN: measured IMD2 at fBLOCK – fTX = 1575 MHz)
824
849
2400
2485
Band 7 (WLAN: measured IMD2 at fBLOCK – fTX = 1575 MHz, PBLOCK = 0 dBm, and PTX =
+24 dBm )
880
915
2400
2485
Band 8 (measured at frequencies where 2620 MHz < fBLOCK – fTX < 2690 MHz, PBLOCK =
–30 dBm, and PTX = +23 dBm)
2500
2570
5150
5850
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201948C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 22, 2013
5
PRELIMINARY DATA SHEET • SKY13448-001 SPDT SWITCH
Table 8. SKY13448-001 Truth Table
Note:
State
Active Path
V1
(Bump 2)
0
ANT to RF1
0
1
ANT to RF2
1
“1” = 1.65 V to 2.70 V. “0” = –0 V to +0.45 V.
Evaluation Board Description
The SKY13448-001 Evaluation Board is used to test the
performance of the SKY13448-001 SPDT Switch. An Evaluation
Board schematic diagram is provided in Figure 3. An assembly
drawing for the Evaluation Board is shown in Figure 4.
Package and Handling Information
Instructions on the shipping container label regarding exposure to
moisture after the container seal is broken must be followed.
Otherwise, problems related to moisture absorption may occur
when the part is subjected to high temperature during solder
assembly.
Wafer Level Chip Scale Packages: SMT Process Guidelines and
Handling Considerations, document number 201676.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
Package Dimensions
Package dimensions for the SKY13448-001 die are shown in
Figure 5, and tape and reel dimensions are provided in Figure 6.
The SKY13448-001 is rated to Moisture Sensitivity Level 1 (MSL1)
at 260 °C. It can be used for lead or lead-free soldering. For
additional information, refer to the Skyworks Application Note,
Figure 3. SKY13448-001 Evaluation Board Schematic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
January 22, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201948C
PRELIMINARY DATA SHEET • SKY13448-001 SPDT SWITCH
Figure 4. SKY13448-001 Evaluation Board Assembly Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201948C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 22, 2013
7
PRELIMINARY DATA SHEET • SKY13448-001 SPDT SWITCH
Figure 5. SKY13448-001 Package Dimensions
Figure 6. SKY13448-001 Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
January 22, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201948C
PRELIMINARY DATA SHEET • SKY13448-001 SPDT SWITCH
Ordering Information
Model Name
SKY13448-001 0.1-2.7 GHz GPIO SPDT Switch in a
WLCSP Package
Manufacturing Part Number
SKY13448-001
Evaluation Board Part Number
SKY13448-001-EVB
Copyright © 2012, 2013 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of
Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands
and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com,
are incorporated by reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201948C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • January 22, 2013
9