Issue Date: 2005-12-05 Amendment 1 2006-04-03 Page 1 of 2 Report Reference # E135803-A19-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): Power Supplies for Information Technology Equipment Including Electrical Business Equipment QQGQ2, QQGQ8 Component Recognition Power Supply GSM11-XYZ-XXXG, where X represents the output voltage which may be any number from 3.3 thru 28; Y indicates the type of input connector used which may be the letters A, B, P or T; Z indicates the type of output connector used which may be the letters A thru Z; Models may or may not be followed by -XXX, where XXX may be any number from 001 thru 999. The -XXX suffix are used for value added configurations that have no impact on safety; and G indicates compliance to RoHS (RoHS compliance has not been evaluated by UL.) Input: 100-240 V ac, 0.3 A, 50/60 Hz Output: 2.2 A or 11 W maximum or see table for standard output voltage models. MODEL GSM11-3 GSM11-5 GSM11-9 GSM11-12 GSM11-15 GSM11-24 GSM11-28 Standards: OUTPUT 3.3 V dc 2.2 A 5.1 V dc 2.2 A 9 V dc 1.22 A 12 V dc 0.92A 15 V dc 0.74A 24 V dc 0.46 A 28 V dc 0.0.4A UL 60950-1:2003, First Edition CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003 Applicant Name and Address: CONDOR D C POWER SUPPLIES INC 2311 STATHAM PKY OXNARD CA 93033 This Report includes the following parts, in addition to this cover page: 1. Specific Technical Criteria 2. Enclosures Copyright © 2006 Underwriters Laboratories Inc. Issue Date: 2005-12-05 Amendment 1 2006-04-03 Page 2 of 2 Report Reference # E135803-A19-UL-1 This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Test Report By: Reviewed By: Ahmad Daoudi Engineering Project Handler Underwriters Laboratories Inc. Beatrice Undorte Senior Staff Engineer Underwriters Laboratories Inc. Copyright © 2006 Underwriters Laboratories Inc. Issue Date: 2005-12-05 Amendment 1 2006-04-03 Page 1 of 4 Report Reference # E135803-A19-UL-1 SPECIFIC TECHNICAL CRITERIA UL 60950-1, First Edition Information technology equipment - SafetyPart 1: General Requirements Report Reference No ........................: E135803-A19-UL-1 Compiled by .....................................: Ahmad Daoudi Reviewed by ....................................: Beatrice Undorte Date of issue ....................................: 2005-12-05 Standards .........................................: UL 60950-1:2003, First Edition CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003 Test procedure .................................: Component Recognition Non-standard test method ...............: N/A Test item description .......................: Power Supply Trademark ........................................: CONDOR Model and/or type reference ............: GSM11-XYZ-XXXG, where X represents the output voltage which may be any number from 3.3 thru 28; Y indicates the type of input connector used which may be the letters A, B, P or T; Z indicates the type of output connector used which may be the letters A thru Z; Models may or may not be followed by -XXX, where XXX may be any number from 001 thru 999. The -XXX suffix are used for value added configurations that have no impact on safety; and G indicates compliance to RoHS (RoHS compliance has not been evaluated by UL.) Rating(s) ...........................................: Input: 100-240 V ac, 0.3 A, 50/60 Hz Output: 2.2 A or 11 W maximum or see table for standard output voltage models. MODEL GSM11-3 GSM11-5 GSM11-9 GSM11-12 GSM11-15 GSM11-24 GSM11-28 OUTPUT 3.3 V dc 2.2 A 5.1 V dc 2.2 A 9 V dc 1.22 A 12 V dc 0.92A 15 V dc 0.74A 24 V dc 0.46 A 28 V dc 0.0.4A Underwriters Laboratories Inc. Issue Date: 2005-12-05 Amendment 1 2006-04-03 Page 2 of 4 Report Reference # E135803-A19-UL-1 Particulars: test item vs. test requirements Equipment mobility .................................................... : for building-in Operating condition ................................................... : continuous Mains supply tolerance (%) ....................................... : +6%, -10% Tested for IT power systems ..................................... : No IT testing, phase-phase voltage (V) .......................... : Single Class of equipment ................................................... : Class II (double insulated) Mass of equipment (kg) ............................................ : 0.045 Protection against ingress of water ........................... : IP X0 Possible test case verdicts: - test case does not apply to the test object ............. : N / A - test object does meet the requirement ................... : Pass - test object does not meet the requirement ............. : Fail (acceptable only if a corresponding, less stringent national requirement is "Pass") General remarks: - "(see Enclosure #)" refers to additional information appended to the Test Report - "(see appended table)" refers to a table appended to the Test Report - Throughout the Test Report a point is used as the decimal separator Underwriters Laboratories Inc. Issue Date: 2005-12-05 Amendment 1 2006-04-03 Page 3 of 4 Report Reference # E135803-A19-UL-1 GENERAL PRODUCT INFORMATION: CA1.0 Report Summary CA1.1 N/A CB1.0 Product Description CB1.1 GSM11-XYZG Series power supplies are switching type power supplies where enclosures are not provided. Maximum wattage output of these power supplies are depended on ambient temperature and type of cooling. See Installation Instructions in the Manual Enclosure. CC1.0 Model Differences CC1.1 The GSM11-XYZG Series are Class II power supplies and differ only in secondary circuits for the different outputs. CD1.0 Additional Information CD1.1 The schematics for these models are kept in file at the CB Testing Laboratory mentioned in the first page of this test report, and can be provided by the applicant upon request by CBTLs. CE1.0 Technical Considerations CE1.2 The product was submitted and tested for use at the maximum ambient temperature (Tma) permitted by the manufacturer’s specification of: 50°C CE1.4 The product is intended for use on the following power systems: TN CE1.7 The product was investigated to the following additional standards: EN 60950-1:2001 (which includes all European national differences, including those specified in this test report). CE1.14 The following are available from the Applicant upon request: Specific data sheets for LEDs that are used for indicating purposes and assumed to be inherently Class 1 operating in the 400 - 700 nm wavelength range. CF1.0 Engineering Conditions of Acceptability CF1.1 For use only in or with complete equipment where the acceptability of the combination is determined by Underwriters Laboratories Inc. When installed in an end-product, consideration must be given to the following: CF1.5 The following secondary output circuits are SELV: All CF1.7 The following secondary output circuits are at non-hazardous energy levels: All CF1.12 The maximum investigated branch circuit rating is: 20 A CF1.13 The investigated Pollution Degree is: 2 CF1.23 The equipment is suitable for direct connection to: AC mains supply CF2.0 This component has been judged on the basis of the required spacings in the First Edition of the Underwriters Laboratories Inc. Issue Date: 2005-12-05 Amendment 1 2006-04-03 Page 4 of 4 Report Reference # E135803-A19-UL-1 Standards for Information Technology Equipment - Safety-, Part 1: General Requirements, UL 60950-1 and CSA C22.2 No. 60950-1, which covers the end use product for which the component is designed., CF2.1 The component shall be installed in compliance with the enclosure, mounting, spacing, casualty markings and segregation requirements of the end- use application., CF2.2 Consideration should be given to measuring the temperature on power electronic components and transformer windings when the power supply is installed in the end-use equipment., CF2.3 The input/output connectors are not acceptable for field connections, they are only intended for connection to mating connectors of internal wiring inside the end-use machine. CF2.4 The component is Class II and should not be bonded to ground in the end-use equipment., CF2.5 The temperature test was performed in a raised ambient of 50°C., CF2.6 The Main Power Transformer (T2), comply with Class F (155°C) limits., CF2.7 The power supply was evaluated as reinforced insulation between primary and secondary., CF2.8 This power supply has been evaluated as Class II, continuous operation, ordinary equipment. CF2.9 This power supply was tested with only one internal fuse, rated T1A, 250V. Underwriters Laboratories Inc.