notice of authorization to apply the ul mark

Issue Date:
2005-12-05
Amendment 1
2006-04-03
Page 1 of 2
Report Reference #
E135803-A19-UL-1
COVER PAGE FOR TEST REPORT
Product Category:
Product Category CCN:
Test Procedure:
Product:
Model/Type Reference:
Rating(s):
Power Supplies for Information Technology Equipment Including Electrical
Business Equipment
QQGQ2, QQGQ8
Component Recognition
Power Supply
GSM11-XYZ-XXXG, where X represents the output voltage which may be any
number from 3.3 thru 28; Y indicates the type of input connector used which
may be the letters A, B, P or T; Z indicates the type of output connector used
which may be the letters A thru Z; Models may or may not be followed by -XXX,
where XXX may be any number from 001 thru 999. The -XXX suffix are used
for value added configurations that have no impact on safety; and G indicates
compliance to RoHS (RoHS compliance has not been evaluated by UL.)
Input: 100-240 V ac, 0.3 A, 50/60 Hz
Output: 2.2 A or 11 W maximum or see table for standard output voltage
models.
MODEL
GSM11-3
GSM11-5
GSM11-9
GSM11-12
GSM11-15
GSM11-24
GSM11-28
Standards:
OUTPUT
3.3 V dc 2.2 A
5.1 V dc 2.2 A
9 V dc 1.22 A
12 V dc 0.92A
15 V dc 0.74A
24 V dc 0.46 A
28 V dc 0.0.4A
UL 60950-1:2003, First Edition
CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003
Applicant Name and
Address:
CONDOR D C POWER SUPPLIES INC
2311 STATHAM PKY
OXNARD CA 93033
This Report includes the following parts, in addition to this cover page:
1. Specific Technical Criteria
2. Enclosures
Copyright © 2006 Underwriters Laboratories Inc.
Issue Date:
2005-12-05
Amendment 1
2006-04-03
Page 2 of 2
Report Reference #
E135803-A19-UL-1
This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the
above referenced Standards. The products have been found to comply with the requirements covering the category and the products are
judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on
such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in
accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being
covered by UL's Follow-Up Service under the indicated Test Procedure.
The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety.
UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific
Technical Criteria through to the end of the Conditions of Acceptability.
Test Report By:
Reviewed By:
Ahmad Daoudi
Engineering Project Handler
Underwriters Laboratories Inc.
Beatrice Undorte
Senior Staff Engineer
Underwriters Laboratories Inc.
Copyright © 2006 Underwriters Laboratories Inc.
Issue Date:
2005-12-05
Amendment 1
2006-04-03
Page 1 of 4
Report Reference #
E135803-A19-UL-1
SPECIFIC TECHNICAL CRITERIA
UL 60950-1, First Edition
Information technology equipment - SafetyPart 1: General Requirements
Report Reference No ........................: E135803-A19-UL-1
Compiled by .....................................: Ahmad Daoudi
Reviewed by ....................................: Beatrice Undorte
Date of issue ....................................: 2005-12-05
Standards .........................................: UL 60950-1:2003, First Edition
CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003
Test procedure .................................: Component Recognition
Non-standard test method ...............: N/A
Test item description .......................: Power Supply
Trademark ........................................: CONDOR
Model and/or type reference ............: GSM11-XYZ-XXXG, where X represents the output voltage which may
be any number from 3.3 thru 28; Y indicates the type of input
connector used which may be the letters A, B, P or T; Z indicates the
type of output connector used which may be the letters A thru Z;
Models may or may not be followed by -XXX, where XXX may be any
number from 001 thru 999. The -XXX suffix are used for value added
configurations that have no impact on safety; and G indicates
compliance to RoHS (RoHS compliance has not been evaluated by
UL.)
Rating(s) ...........................................: Input: 100-240 V ac, 0.3 A, 50/60 Hz
Output: 2.2 A or 11 W maximum or see table for standard output
voltage models.
MODEL
GSM11-3
GSM11-5
GSM11-9
GSM11-12
GSM11-15
GSM11-24
GSM11-28
OUTPUT
3.3 V dc 2.2 A
5.1 V dc 2.2 A
9 V dc 1.22 A
12 V dc 0.92A
15 V dc 0.74A
24 V dc 0.46 A
28 V dc 0.0.4A
Underwriters Laboratories Inc.
Issue Date:
2005-12-05
Amendment 1
2006-04-03
Page 2 of 4
Report Reference #
E135803-A19-UL-1
Particulars: test item vs. test requirements
Equipment mobility .................................................... : for building-in
Operating condition ................................................... : continuous
Mains supply tolerance (%) ....................................... : +6%, -10%
Tested for IT power systems ..................................... : No
IT testing, phase-phase voltage (V) .......................... : Single
Class of equipment ................................................... : Class II (double insulated)
Mass of equipment (kg) ............................................ : 0.045
Protection against ingress of water ........................... : IP X0
Possible test case verdicts:
- test case does not apply to the test object ............. : N / A
- test object does meet the requirement ................... : Pass
- test object does not meet the requirement ............. : Fail (acceptable only if a corresponding, less stringent
national requirement is "Pass")
General remarks:
- "(see Enclosure #)" refers to additional information appended to the Test Report
- "(see appended table)" refers to a table appended to the Test Report
- Throughout the Test Report a point is used as the decimal separator
Underwriters Laboratories Inc.
Issue Date:
2005-12-05
Amendment 1
2006-04-03
Page 3 of 4
Report Reference #
E135803-A19-UL-1
GENERAL PRODUCT INFORMATION:
CA1.0
Report Summary
CA1.1
N/A
CB1.0
Product Description
CB1.1
GSM11-XYZG Series power supplies are switching type power supplies where enclosures are
not provided. Maximum wattage output of these power supplies are depended on ambient
temperature and type of cooling. See Installation Instructions in the Manual Enclosure.
CC1.0
Model Differences
CC1.1
The GSM11-XYZG Series are Class II power supplies and differ only in secondary circuits for the
different outputs.
CD1.0
Additional Information
CD1.1
The schematics for these models are kept in file at the CB Testing Laboratory mentioned in the
first page of this test report, and can be provided by the applicant upon request by CBTLs.
CE1.0
Technical Considerations
CE1.2
The product was submitted and tested for use at the maximum ambient temperature (Tma)
permitted by the manufacturer’s specification of: 50°C
CE1.4
The product is intended for use on the following power systems: TN
CE1.7
The product was investigated to the following additional standards: EN 60950-1:2001 (which
includes all European national differences, including those specified in this test report).
CE1.14
The following are available from the Applicant upon request: Specific data sheets for LEDs that
are used for indicating purposes and assumed to be inherently Class 1 operating in the 400 - 700
nm wavelength range.
CF1.0
Engineering Conditions of Acceptability
CF1.1
For use only in or with complete equipment where the acceptability of the combination is
determined by Underwriters Laboratories Inc.
When installed in an end-product, consideration must be given to the following:
CF1.5
The following secondary output circuits are SELV: All
CF1.7
The following secondary output circuits are at non-hazardous energy levels: All
CF1.12
The maximum investigated branch circuit rating is: 20 A
CF1.13
The investigated Pollution Degree is: 2
CF1.23
The equipment is suitable for direct connection to: AC mains supply
CF2.0
This component has been judged on the basis of the required spacings in the First Edition of the
Underwriters Laboratories Inc.
Issue Date:
2005-12-05
Amendment 1
2006-04-03
Page 4 of 4
Report Reference #
E135803-A19-UL-1
Standards for Information Technology Equipment - Safety-, Part 1: General Requirements, UL
60950-1 and CSA C22.2 No. 60950-1, which covers the end use product for which the
component is designed.,
CF2.1
The component shall be installed in compliance with the enclosure, mounting, spacing, casualty
markings and segregation requirements of the end- use application.,
CF2.2
Consideration should be given to measuring the temperature on power electronic components
and transformer windings when the power supply is installed in the end-use equipment.,
CF2.3
The input/output connectors are not acceptable for field connections, they are only intended for
connection to mating connectors of internal wiring inside the end-use machine.
CF2.4
The component is Class II and should not be bonded to ground in the end-use equipment.,
CF2.5
The temperature test was performed in a raised ambient of 50°C.,
CF2.6
The Main Power Transformer (T2), comply with Class F (155°C) limits.,
CF2.7
The power supply was evaluated as reinforced insulation between primary and secondary.,
CF2.8
This power supply has been evaluated as Class II, continuous operation, ordinary equipment.
CF2.9
This power supply was tested with only one internal fuse, rated T1A, 250V.
Underwriters Laboratories Inc.