Issue Date: 2007-05-23 Page 1 of 3 Report Reference # E135803-A37-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): Power Supplies for Information Technology Equipment Including Electrical Business Equipment QQGQ2, QQGQ8 Component Recognition Power Supply GEM600-VV-WXY-ZZ G and GEM750-VV-WXY-ZZ G (where W is an alpha character A or T, X is an alpha character A, B or T, Y is an Alpha Character D, -ZZ is any numeric character 00-99 and the G designation is optional). GEM600-VV-WXY-ZZ G Input: 100-240 Vac, 50/60 Hz, 9 A/4.5 A Output: V1: V2: V3: V4: 24 Vdc, 25.0 A, 27.0 A-PK 28 Vdc, 21.5 A, 23.5 A-PK 36 Vdc, 16.7 A, 18.0 A-PK 48 Vdc, 12.5 A, 13.5 A-PK GEM750-VV-WXY-ZZ G Input: 100-240 Vac, 50/60 Hz, 11 A/5.5 A Output: V1: V2: V3: V4: 24 Vdc, 31.2 A, 34.0 A-PK 28 Vdc, 26.8 A, 29.5 A-PK 36 Vdc, 20.8 A, 22.8 A-PK 48 Vdc, 15.6 A, 17.0 A-PK Airflow: 42 CFM with integral fan Ambient: 50°C Standards: Applicant Name and Address: *Peak current is for a maximum duration of 60 seconds with a 10% duty cycle. UL 60950-1, 1st Edition, 2006-07-07 (Information Technology Equipment Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07 (Information Technology Equipment - Safety - Part 1: General Requirements) SL POWER ELECTRONICS CORP 6050 KING ST VENTURA CA 93003 Copyright © 2007 Issue Date: 2007-05-23 Page 2 of 3 Report Reference # This Report includes the following parts, in addition to this cover page: 1. Specific Inspection Criteria 2. Specific Technical Criteria 3. Clause Verdicts 4. Critical Components 5. Test Results 6. National Differences 7. Enclosures Copyright © 2007 E135803-A37-UL-1 Issue Date: 2007-05-23 Page 3 of 3 Report Reference # E135803-A37-UL-1 This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL. Test Report By: Reviewed By: Linus Park Lead Engineering Associate Underwriters Laboratories Inc. Kevin Tang Staff Engineer Underwriters Laboratories Inc. Copyright © 2007 Issue Date: 2007-05-23 Page 3 of 46 Report Reference # E135803-A37-UL-1 SPECIFIC TECHNICAL CRITERIA UL 60950-1, First Edition Information technology equipment - SafetyPart 1: General Requirements Report Reference No ........................: E135803-A37-UL-1 Compiled by .....................................: Linus Park Reviewed by ....................................: Kevin Tang Date of issue ....................................: 2007-05-23 Standards .........................................: UL 60950-1, 1st Edition, 2006-07-07 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07 (Information Technology Equipment - Safety - Part 1: General Requirements) Test procedure .................................: Component Recognition Non-standard test method ...............: N/A Test item description .......................: Power Supply Trademark ........................................: None Model and/or type reference ............: GEM600-VV-WXY-ZZ G and GEM750-VV-WXY-ZZ G (where W is an alpha character A or T, X is an alpha character A, B or T, Y is an Alpha Character D, -ZZ is any numeric character 00-99 and the G designation is optional). Rating(s) ...........................................: GEM600-VV-WXY-ZZ G Input: 100-240 Vac, 50/60 Hz, 9 A/4.5 A Output: V1: V2: V3: V4: 24 Vdc, 25.0 A, 27.0 A-PK 28 Vdc, 21.5 A, 23.5 A-PK 36 Vdc, 16.7 A, 18.0 A-PK 48 Vdc, 12.5 A, 13.5 A-PK GEM750-VV-WXY-ZZ G Input: 100-240 Vac, 50/60 Hz, 11 A/5.5 A Output: V1: V2: V3: V4: 24 Vdc, 31.2 A, 34.0 A-PK 28 Vdc, 26.8 A, 29.5 A-PK 36 Vdc, 20.8 A, 22.8 A-PK 48 Vdc, 15.6 A, 17.0 A-PK Airflow: 42 CFM with integral fan Ambient: 50°C *Peak current is for a maximum duration of 60 seconds with a 10% duty cycle. Underwriters Laboratories Inc. Issue Date: 2007-05-23 Page 4 of 46 Report Reference # E135803-A37-UL-1 Particulars: test item vs. test requirements Equipment mobility .................................................... : for building-in Operating condition ................................................... : continuous Mains supply tolerance (%) ....................................... : +6%, -10% Tested for IT power systems ..................................... : No IT testing, phase-phase voltage (V) .......................... : N/A Class of equipment ................................................... : Class I (earthed) Mass of equipment (kg) ............................................ : 1.72 Protection against ingress of water ........................... : IP X0 Possible test case verdicts: - test case does not apply to the test object ............. : N / A - test object does meet the requirement ................... : Pass - test object does not meet the requirement ............. : Fail (acceptable only if a corresponding, less stringent national requirement is "Pass") General remarks: - "(see Enclosure #)" refers to additional information appended to the Test Report - "(see appended table)" refers to a table appended to the Test Report - Throughout the Test Report a point is used as the decimal separator Underwriters Laboratories Inc. Issue Date: 2007-05-23 Page 5 of 46 Report Reference # E135803-A37-UL-1 GENERAL PRODUCT INFORMATION: CA1.0 Report Summary CA1.1 N/A CB1.0 Product Description CB1.1 These products are component switch-mode power supplies intended to be built into an end product. Input/output connectors are provided for factory wiring in the end use equipment. CC1.0 Model Differences CC1.1 All models within the Model Series GEM600 are similar with exception to the Main Power Transformers and minor component changes. All models within the Model Series GEM750 are similar with exception to the Main Power Transformers and minor component changes. Model Series GEM600 and GEM750 are nearly identical to each other with exception to the difference to the Power FETS, which are more robust in the GEM750 Series. Models GEM600-VV-WXY-ZZ G and GEM750-VV-WXY-ZZ G have following nomenclature differences: Where VV is the output Voltage 24-48VDC W is an alpha character A or T, which represents the Input Connector X is an alpha character A, B or T which represents the Output Connector Y is an alpha Character D, which represents the Optional OR-ing Diode -ZZ is any numeric character 00-99 which represents Value Added Configurations not related to safety "G" indicates the manufacturer's claim of compliance with the RoHS directive CD1.0 Additional Information CD1.1 N/A CE1.0 Technical Considerations CE1.2 The product was submitted and tested for use at the maximum ambient temperature (Tma) permitted by the manufacturer’s specification of: 40°C CE1.4 The product is intended for use on the following power systems: TN CF1.0 Engineering Conditions of Acceptability CF1.1 For use only in or with complete equipment where the acceptability of the combination is determined by Underwriters Laboratories Inc. When installed in an end-product, consideration must be given to the following: Underwriters Laboratories Inc. Issue Date: 2007-05-23 Page 6 of 46 Report Reference # E135803-A37-UL-1 CF1.2 The following Production-Line tests are conducted for this product: Electric Strength, Earthing Continuity CF1.3 The end-product Electric Strength Test is to be based upon a maximum working voltage of: Primary-SELV: 385 Vrms, 671 Vpk, Primary-Earthed Dead Metal: 312 Vrms. CF1.5 The following secondary output circuits are SELV: All outputs CF1.6 The following secondary output circuits are at hazardous energy levels: All Outputs CF1.11 The power supply terminals and/or connectors are: Suitable for factory wiring only, Not investigated for field wiring CF1.12 The maximum investigated branch circuit rating is: 20 A CF1.13 The investigated Pollution Degree is: 2 CF1.15 Proper bonding to the end-product main protective earthing termination is: Required. Power Supply Chassis is functional earthed. Additional bonding will be required in the end-product. CF1.16 An investigation of the protective bonding terminals has: Been conducted CF1.18 The following magnetic devices (e.g. transformers or inductor) are provided with an OBJY2 insulation system with the indicated rating greater than Class A (105°C): T6 (Class F) and T7 (Class F) CF1.19 The following end-product enclosures are required: Mechanical, Fire, Electrical CF1.21 The maximum continuous power supply output (Watts) relied on forced air cooling from: Model GEM600 Series: 600 W fan at 42 cfm applied to the top of the power supply. Model GEM750 Series: 750 W fan at 42 cfm applied to the top of the power supply. CF1.23 The equipment is suitable for direct connection to: AC mains supply Underwriters Laboratories Inc.