GPM40 Instructions - SL Power Electronics

6050 King St. Unit A
Ventura, CA 93003 + 805-486-4565
Internet: www.slpower.com
MODEL NUMBERS: GPM40A, GPM40B, GPM40D, and GPM40-X, where X represents the output
voltage, which may be any number from 3.3 through 28. Models may or may not be followed by suffix
–XXX and/or G, where XXX may be any number from 001 thru 999. The –XXX suffix are used for
value added configurations that have no impact on safety and suffix G indicates compliance to RoHS.
RATINGS:
Input: 100-240 V ac, 1.3 A, 50/60Hz
Outputs: 40 W max or see table for standard output voltage models.
Model
GPM40A
GPM40B
GPM40D
GPM40-3.3
GPM40-5
GPM40-9
GPM40-12
GPM40-15
GPM40-24
GPM40-28
Watts1
40
40
40
26.4
40
40
40
40
40
40
Output #1
+5.1 V dc 4 A
+5.1 V dc 4 A
+5.1 V dc 4 A
3.3 V dc 8 A
5.0 V dc 8 A
9.0 V dc 4.4 A
12.0 V dc 3.4 A
15.0 V dc 2.7 A
24.0 V dc 1.7 A
28.0 V dc 1.5 A
Output #2
+12 V dc 2 A
+15 V dc 2 A
+24 V dc 1 A
Output #3
-12 V dc 0.4 A
-15 V dc 0.4 A
-12 V dc 0.4 A
Notes:
1. Maximum continuous output power at 50 °C - Total
of all Outputs.
2. Maximum Relative Humidity 96 %, no condensation.
3. Storage: -40 to +85 °C. Units should be allowed to
warm-up under non-condensing conditions
before application of power.
SAFETY DECLARATION: Condor DC Power Supplies, Inc. declares under our sole
responsibility that all models listed above are in conformity with the applicable requirements
of EN 60950-1 following the provisions of the Low Voltage Directive 73/23/EEC. All
models are Certified to be in compliance with the applicable requirements of UL 544, UL 2601-1, UL
60950-1, CSA 22.2 No. 601.1 (L3M1), and EN 60601-1.
CLASSIFICATION:
(In accordance with
sub- clause 5
of EN 60601-1)
(5.1) Protection against electric shock = Class I
(5.2) Degree of protection against electric shock = Not acceptable for applied
part without additional isolation (contact factory for details)
(5.3) Protection against harmful ingress of water = Ordinary (no protection)
(5.5) Have not been evaluated for use in the presence of a flammable anaesthetic
mixture with air, oxygen, or nitrous oxide. This evaluation is to be made on the
end equipment by the OEM.
(5.6) Mode of operation = Continuous
GROUNDING: The Protective Earth (ground) terminal must be bonded to Protective Earth in the host
equipment. Using the Protective Earth terminal on the supply for grounding the host equipment is not
recommended. A separate dedicated grounding point should be used.
OUTPUTS: All output commons should be connected to Protective Earth in the end application. The
output(s) are intended for Protectively Earthed Signal Output and Intermediate Circuits only. The
output(s) are not acceptable for patient connection without additional isolation. All DC outputs are
SELV under normal and single fault conditions.
41-32580-0001 Rev. J 6/5/06
Page 1 of 2
OVERVOLTAGE PROTECTION: Only output #1 is monitored for an overvoltage condition. The
trip-point for a 5 volt output is 5.6 to 6.8 volts. In some applications where an overvoltage condition
could result in a hazard as defined in applicable safety standards, redundant or additional overvoltage
protection may be required. Consult factory for details.
ISOLATION: The components providing isolation from primary to secondary are 100 % tested at 4000
V ac. The creepage distance between primary and ground is 4 mm minimum; between primary and
secondary circuits is 8 mm minimum. Secondary to ground creepage is not defined or controlled. The
output common is bypassed to ground using a 0.01 µF 1 kV capacitor. The required creepage and
clearance distances from primary circuits to ground and secondary circuits must be maintained after
installation to preserve the intended safety.
TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in
the applicable safety standards, must not be exceeded after installation to preserve the intended safety.
The output power, ambient air temperature and the availability, amount, direction and/or restriction of
airflow influence the temperatures of these components.
OVERCURRENT PROTECTION: The internal fuse is located in the phase lead only. EN 60601-1
requires that both supply leads (phase and neutral) be protected against overcurrent. Complete
overcurrent protection must be provided in the host equipment. Fuse ratings must not exceed that
specified for the internal fuse, must meet the requirements of EN 60601-1 and be acceptable for the
country in which the host equipment is to be installed.
EXPLANATION OF SYMBOLS
WARNING! RISK OF FIRE! A blown internal fuse is an
indication of catastrophic failure of circuit component(s). Repair
must be performed by Condor authorized personnel. Refer to fuse
marking on the supply for rating.
Alternating Current
WARNING! SHOCK HAZARD! Dangerous voltages are present
on some components, printed wiring traces and heatsinks.
Attention, Dangerous Voltages
Direct Current
Attention, Consult
Accompanying Documents
Earth (Ground)
CONNECTIONS
J1 AC Input
1) Line
3) Neutral
CAUTION:
Do not exceed 5 A per contact on J2.
Mating Connectors: Amp P/N 640250-3
Contacts: Amp P/N 770476-1
Multi-Output Models
J2 DC Outputs
1) Output 2 (+)
2) Output 1 (+)
3) Output 1 (+)
4) Common
5) Common
6) Output 3 (-)
Amp P/N 640250-6
Amp P/N 770476-1
Single Output Models
J2 DC Output
J3
1) Output 1 (+)
1) + Sense
2) Output 1 (+)
2) Com Sense
3) Output 1 (+)
4) Common
5) Common
6) Common
Amp P/N 640250-6
Amp P/N 770476-1
Amp MTA100 Series
SL Power Electronics, Corp. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications
or repairs are carried out by other than authorized agents of SL Power Electronics, Corp., or b) the installation of the supply is not in
accordance with these installation instructions and the applicable UL, CSA, and/or IEC safety standards.
41-32580-0001 Rev. J 6/5/06