gpc40 series installation instructions

GPC40 SERIES
INSTALLATION INSTRUCTIONS
CONDOR DC POWER SUPPLIES INC.
2311 STATHAM PKWY
OXNARD, CA 93033 + 805-486-4565
Internet: www.condorpower.com
MODEL NUMBERS: GPC40A, GPC40B, GPC40D, and GPC40-X, where X represents the output voltage, which may be
any number from 3.3 through 28. Models may or may not be followed by suffix –XXX and/or G, where XXX may be any
number from 001 thru 999. The –XXX suffix are used for value added configurations that have no impact on safety and
suffix G indicates compliance to RoHS.
RATINGS:
Input: 100-240 V ac, 1.3 A, 50/60 Hz
Outputs: 40 W max or see table for standard output voltage models.
Model
GPC40A
GPC40B
GPC40D
GPC40-3.3
GPC40-5
GPC40-9
GPC40-12
GPC40-15
GPC40-24
GPC40-28
Watts1
40
40
40
26.4
40
40
40
40
40
40
Output #1
+5.1 V dc 4 A
+5.1 V dc 4 A
+5.1 V dc 4 A
3.3 V dc 8 A
5.0 V dc 8 A
9.0 V dc 4.4 A
12.0 V dc 3.4 A
15.0 V dc 2.7 A
24.0 V dc 1.7 A
28.0 V dc 1.5 A
Output #2
+12 V dc 2 A
+15 V dc 2 A
+24 V dc 1 A
Output #3
-12 V dc 0.4 A
-15 V dc 0.4 A
-12 V dc 0.4 A
Notes:
1. Maximum continuous output power at 50 °C - Total
of all Outputs.
2. Maximum Relative Humidity 96 %, no condensation.
3. Storage: -40 to +85 °C. Units should be allowed to warm-up
under non-condensing conditions before application of power.
SAFETY DECLARATION: Condor DC Power Supplies, Inc. declares under our sole responsibility that all
models listed above are in conformity with the applicable requirements of EN 60950-1 following the provisions of
the Low Voltage Directive 73/23/EEC. All models are Certified to be in compliance with the applicable
requirements of UL 60950-1, CSA 22.2 No. 60950-1-03 (L3M1), and EN 60950-1 for Pollution Degree 2 environment and
Class I TN-S power systems. The output(s) of these supplies meet the requirements for SELV and are not an energy hazard.
GROUNDING: The Earth (Ground) terminal must be bonded to Protective Earth in the end application. Using this terminal
for the end product protective earthing terminal is not recommended. A separate dedicated protective earthing point should
be used.
SPACINGS: Creepage and clearance distances from primary circuits to ground and secondary circuits, as defined in the
applicable safety standards, must be maintained after installation to preserve the intended safety.
TEMPERATURES:
The maximum operating temperatures of certain safety
EXPLANATION OF SYMBOLS
components, as defined in the applicable safety standards, must not be exceeded after
Alternating Current
installation to preserve the intended safety. The output power, ambient air temperature
and the availability, amount, direction and/or restriction of airflow influence the
Direct Current
temperatures of these components.
Attention, Consult
Accompanying Documents
WARNING! RISK OF FIRE! A blown fuse is an indication of catastrophic failure of
circuit component(s). Repair must be performed by Condor authorized personnel. Fuse
Attention, Dangerous Voltages
F1 must be replaced with F 2 A 250 V (fast blow), UL Listed and CSA Certified type.
Earth (Ground)
WARNING! SHOCK HAZARD! Dangerous voltages are present on some
components and printed wiring traces.
CONNECTIONS
J1 AC Input
1) Line
3) Neutral
CAUTION:
Do not exceed 5 A per contact on J2.
Mating Connectors:
Contacts:
Amp P/N 640250-3
Amp P/N 770476-1
Multi-Output Models
J2 DC Outputs
1) Output 2 (+)
2) Output 1 (+)
3) Output 1 (+)
4) Common
5) Common
6) Output 3 (-)
Amp P/N 640250-6
Amp P/N 770476-1
Single Output Models
J2 DC Output
J3
1) Output 1 (+)
1) + Sense
2) Output 1 (+)
2) Com Sense
3) Output 1 (+)
4) Common
5) Common
6) Common
Amp P/N 640250-6
Amp MTA100 Series
Amp P/N 770476-1
Condor DC Power Supplies Inc. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other than
authorized agents of Condor DC Power Supplies Inc., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA, EN/IEC safety
standards.